3.
BMC Cardiovasc Disord ; 24(1): 301, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872098

RESUMO

BACKGROUND: Studies of transcatheter pulmonary valve replacement (TPVR) with the Melody valve have demonstrated good clinical and hemodynamic outcomes. Our study analyzes the midterm clinical and hemodynamic outcomes for patients who underwent Melody valve implantation in Southeast Asia. METHODS: Patients with circumferential conduits or bioprosthetic valves and experiencing post-operative right ventricular outflow tract (RVOT) dysfunction were recruited for Melody TPVR. RESULTS: Our cohort (n = 14) was evenly divided between pediatric and adult patients. The median age was 19 years (8-38 years), a male-to-female ratio of 6:1 with a median follow-up period of 48 months (16-79 months), and the smallest patient was an 8-year-old boy weighing 18 kg. All TPVR procedures were uneventful and successful with no immediate mortality or conduit rupture. The primary implant indication was combined stenosis and regurgitation. The average conduit diameter was 21 ± 2.3 mm. Concomitant pre-stenting was done in 71.4% of the patients without Melody valve stent fractures (MSFs). Implanted valve size included 22-mm (64.3%), 20-mm (14.3%), and 18-mm (21.4%). After TPVR, the mean gradient across the RVOT was significantly reduced from 41 mmHg (10-48 mmHg) to 16 mmHg (6-35 mmHg) at discharge, p < 0.01. Late follow-up infective endocarditis (IE) was diagnosed in 2 patients (14.3%). Overall freedom from IE was 86% at 79 months follow-up. Three patients (21.4%) developed progressive RVOT gradients. CONCLUSION: For patients in Southeast Asia with RVOT dysfunction, Melody TPVR outcomes are similar to those reported for patients in the US in terms of hemodynamic and clinical improvements. A pre-stenting strategy was adopted and no MSFs were observed. Post-implantation residual stenosis and progressive stenosis of the RVOT require long term monitoring and reintervention. Lastly, IE remained a concern despite vigorous prevention and peri-procedural bacterial endocarditis prophylaxis.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Valva Pulmonar , Recuperação de Função Fisiológica , Humanos , Masculino , Criança , Feminino , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Adolescente , Valva Pulmonar/cirurgia , Valva Pulmonar/fisiopatologia , Valva Pulmonar/diagnóstico por imagem , Resultado do Tratamento , Adulto Jovem , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Fatores de Tempo , Adulto , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Bioprótese , Estenose da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Sudeste Asiático
5.
JACC Cardiovasc Interv ; 17(12): 1470-1481, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38925751

RESUMO

BACKGROUND: A novel echocardiography-based definition of atrial functional tricuspid regurgitation (A-FTR) has shown superior outcomes in patients undergoing conservative treatment or tricuspid valve transcatheter edge-to-edge repair. Its prognostic significance for transcatheter tricuspid valve annuloplasty (TTVA) outcomes is unknown. OBJECTIVES: This study sought to investigate prognostic, clinical, and technical implications of A-FTR phenotype in patients undergoing TTVA. METHODS: This multicenter study investigated clinical and echocardiographic outcomes up to 1 year in 165 consecutive patients who underwent TTVA for A-FTR (characterized by the absence of tricuspid valve tenting, midventricular right ventricular [RV] dilatation, and impaired left ventricular ejection fraction) and nonatrial functional tricuspid regurgitation (NA-FTR). RESULTS: A total of 62 A-FTR and 103 NA-FTR patients were identified, with the latter exhibiting more pronounced RV remodeling. Compared to baseline, the tricuspid regurgitation (TR) grade at discharge was significantly reduced (P < 0.001 for both subtypes), and TR ≤II was achieved more frequently in A-FTR (85.2% vs 60.8%; P = 0.001). Baseline TR grade and A-FTR phenotype were independently associated with TR ≤II at discharge and 30 days. In multivariate analyses, A-FTR phenotype was a strong predictor (OR: 5.8; 95% CI: 2.1-16.1; P < 0.001) of TR ≤II at 30 days. At 1 year, functional class had significantly improved compared to baseline (both P < 0.001). One-year mortality was lower in A-FTR (6.5% vs 23.8%; P = 0.011) without significant differences in heart failure hospitalizations (13.3% vs 22.7%; P = 0.188). CONCLUSIONS: Direct TTVA effectively reduces TR in both A-FTR, which is a strong and independent predictor of achieving TR ≤II, and NA-FTR. Even though NA-FTR showed more RV remodeling at baseline, both phenotypes experienced similar symptomatic improvement, emphasizing the benefit of TTVA even in advanced disease stages. Additionally, phenotyping was of prognostic relevance in patients undergoing TTVA.


Assuntos
Cateterismo Cardíaco , Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/mortalidade , Feminino , Masculino , Idoso , Valva Tricúspide/fisiopatologia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Anuloplastia da Valva Cardíaca/efeitos adversos , Anuloplastia da Valva Cardíaca/mortalidade , Anuloplastia da Valva Cardíaca/instrumentação , Fatores de Risco , Idoso de 80 Anos ou mais , Recuperação de Função Fisiológica , Remodelação Ventricular , Função Ventricular Esquerda , Fenótipo , Função Ventricular Direita , Estudos Retrospectivos , Pessoa de Meia-Idade , Volume Sistólico , Valor Preditivo dos Testes
9.
Eur J Cardiothorac Surg ; 65(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38913864

RESUMO

OBJECTIVES: Evidence on long-term clinical outcomes considering suture-securing techniques used for surgical aortic valve replacement is still uncertain. METHODS: A total of 1405 patients who underwent surgical aortic valve replacement between January 2016 and December 2022 were included and grouped according to the suture-securing technique used (automated titanium fastener versus hand-tied knots). The occurrence of infective endocarditis during follow-up was set as the primary study end-point. As secondary study end-points, stroke, all-cause mortality and a composite outcome of either infective endocarditis, stroke, or all-cause mortality were assessed. RESULTS: The automated titanium fastener was used in 829 (59%) patients, whereas the hand-knot tying technique was used in 576 (41%) patients. The multivariable proportional competing risk regression analysis showed a significantly lower risk of infective endocarditis during follow-up in the automated titanium fastener group (adjusted sub-hazard ratio 0.44, 95% confidence interval 0.20-0.94, P = 0.035). The automated titanium fastener group was not associated with an increased risk of mortality or attaining the composite outcome, respectively (adjusted hazard ratio 0.81, 95% confidence interval 0.60-1.09, P = 0.169; adjusted hazard ratio 0.82, 95% confidence interval 0.63-1.07, P = 0.152). This group was not associated with an increased risk of stroke (adjusted sub-hazard ratio 0.82, 95% confidence interval 0.47-1.45, P = 0.504). Also, a significantly lower rate of early-onset infective endocarditis was observed in the automated titanium fastener group, (0.4% vs 1.4%, P = 0.032). CONCLUSIONS: Suture-securing with an automated titanium fastener device appears to be superior compared to the hand-knot tying technique in terms of lower risk of infective endocarditis.


Assuntos
Valva Aórtica , Endocardite , Implante de Prótese de Valva Cardíaca , Técnicas de Sutura , Titânio , Humanos , Masculino , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Idoso , Valva Aórtica/cirurgia , Endocardite/prevenção & controle , Técnicas de Sutura/instrumentação , Estudos Retrospectivos , Pessoa de Meia-Idade , Próteses Valvulares Cardíacas/efeitos adversos
10.
Eur J Cardiothorac Surg ; 66(1)2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38936344

RESUMO

OBJECTIVES: Prothesis choice in isolated mitral valve replacement for patients aged 75 years or younger remains debated as most studies comparing prothesis type have included large proportions of combined operations and benefits are influenced by concomitant procedures. This study compared long-term outcomes of isolated mechanical versus bioprosthetic mitral valves in different age groups of propensity-matched populations. METHODS: This is a retrospective, multicentre, propensity-matched observational study. Baseline characteristics, operative details and long-term outcomes (mortality and freedom from surgical/transcatheter reintervention) were collected. RESULTS: Totally, 1536 isolated mitral valve replacements (806 mechanical, 730 bioprosthetic) were performed between 2000 and 2017. Over 90% of eligible patients successfully underwent propensity matching, yielding 226 each of mechanical and bioprosthetic valves in patients aged <65 years and 171 each of bioprosthetic and mechanical valves in patients aged 65-75 years with median follow-up of 13 years (maximum 20 years). In matched patients <65 years, 10-year survival was superior with mechanical valves versus bioprosthetic valves (78.2% vs 69.8%, P = 0.029), as was 10-year freedom from reintervention (96.2% vs 81.3%, P < 0.001). For matched patients between 65 and 75 years, there were no differences between mechanical and bioprosthetic valves in 10-year survival (64.6% vs 60.8%, P = 0.86) or 10-year freedom from reintervention (94.0% vs 97.2%, P = 0.23). Rates of post-operative stroke, gastrointestinal bleeding, renal failure and permanent pacemaker insertion were similar. CONCLUSIONS: In patients requiring isolated mitral valve replacement, mechanical valves confer significantly better long-term survival and freedom from reintervention for patients <65 years, while no benefit is observed at age 65-75 years compared to bioprosthetic valves.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Mitral , Pontuação de Propensão , Humanos , Idoso , Masculino , Feminino , Estudos Retrospectivos , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/instrumentação , Pessoa de Meia-Idade , Fatores Etários , Resultado do Tratamento , Desenho de Prótese , Doenças das Valvas Cardíacas/cirurgia , Complicações Pós-Operatórias/epidemiologia
13.
Curr Cardiol Rep ; 26(6): 459-474, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38884853

RESUMO

PURPOSE OF REVIEW: Patients with severe tricuspid regurgitation (TR) are at risk for significant morbidity and mortality. Transcatheter tricuspid valve interventions (TTVI) may offer patients less invasive treatment alternatives to surgery. This review evaluates the most common class of device currently used worldwide to treat TR, tricuspid transcatheter edge-to-edge repair (T-TEER) and orthotopic transcatheter tricuspid valve replacement (TTVR), both of which are now approved in the USA and Europe. RECENT FINDINGS: The first pivotal randomized clinical trial, TRILUMINATE, demonstrated that T-TEER can safely reduce TR and is associated with improved health status outcomes. However, results of this trial have raised questions about whether this device can provide sufficient TR reduction to impact clinical outcomes. Orthotopic TTVR has recently gained attention with initial data suggesting near-complete TR elimination. The current review examines the technical features and anatomic limitations of the most commonly used devices for T-TEER and orthotopic TTVR, discusses the current clinical data for these devices, and offers a theoretical construct for device selection.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/instrumentação , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto
14.
JACC Cardiovasc Interv ; 17(12): 1517-1518, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38842997
16.
J Am Heart Assoc ; 13(10): e033605, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38742523

RESUMO

BACKGROUND: Minimally invasive mitral valve repair has a favorable risk-benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge-to-edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). METHODS AND RESULTS: We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long-term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P=0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P=0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no (P=0.558) patients. Clinical follow-up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P>0.05). Propensity score-adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09-0.81]; P=0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P>0.05). CONCLUSIONS: In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Sistema de Registros , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Masculino , Feminino , Idoso , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Itália/epidemiologia , Idoso de 80 Anos ou mais , Readmissão do Paciente/estatística & dados numéricos , Falha de Tratamento , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/instrumentação , Anuloplastia da Valva Mitral/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Fatores de Risco , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia
17.
Curr Probl Cardiol ; 49(8): 102687, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38821232

RESUMO

Tricuspid valve regurgitation, or TR, is a difficult-to-manage condition. In addition to EVOQUE, percutaneous annuloplasty, and surgical repair, the TriClip G4 system has been added to the interventional therapeutic choices for TR. Recently, the Food and Drug Administration (FDA) approved the use of the TriClip G4 device to treat patients with symptomatic, severe TR who have received optimal medication therapy but are at intermediate or higher risk of surgery. This review attempts to offer a thorough examination of the procedural features, learning curves, results of the device and compares the TriClip G4 system to other interventional therapies for TR. TriClip G4 has shown to have promising results in pivotal clinical trials, be cost-effective, and improve the quality of life of patients. Furthermore, it has its unique advantages against other conventional techniques and devices.


Assuntos
Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Cateterismo Cardíaco/métodos , Próteses Valvulares Cardíacas , Anuloplastia da Valva Cardíaca/métodos , Resultado do Tratamento , Desenho de Prótese
18.
JACC Cardiovasc Interv ; 17(12): 1485-1495, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38752971

RESUMO

BACKGROUND: The safety profile of transcatheter tricuspid valve (TTV) repair techniques is well established, but residual tricuspid regurgitation (TR) remains a concern. OBJECTIVES: The authors sought to assess the impact of residual TR severity post-TTV repair on survival. METHODS: We evaluated the survival rate at 2 years of 613 patients with severe isolated functional TR who underwent TTV repair in TRIGISTRY according to the severity of residual TR at discharge using a 3-grade (mild, moderate, and severe) or 4-grade scheme (mild, mild to moderate, moderate to severe, and severe). RESULTS: Residual TR was none/mild in 33%, moderate in 52%, and severe in 15%. The 2-year adjusted survival rates significantly differed between the 3 groups (85%, 70%, and 44%, respectively; restricted mean survival time [RMST]: P = 0.0001). When the 319 patients with moderate residual TR were subdivided into mild to moderate (n = 201, 33%) and moderate to severe (n = 118, 19%), the adjusted survival rate was also significantly different between groups (85%, 80%, 55%, and 44%, respectively; RMST: P = 0.001). Survival was significantly lower in patients with moderate to severe residual TR compared to patients with mild to moderate residual TR (P = 0.006). No difference in survival rates was observed between patients with no/mild and mild to moderate residual TR (P = 0.67) or between patients with moderate to severe and severe residual TR (P = 0.96). CONCLUSIONS: The moderate residual TR group was heterogeneous and encompassed patients with markedly different clinical outcomes. Refining TR grade classification with a more granular 4-grade scheme improved outcome prediction. Our results highlight the importance of achieving a mild to moderate or lower residual TR grade during TTV repair, which could define a successful intervention.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/mortalidade , Masculino , Feminino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Valva Tricúspide/fisiopatologia , Idoso , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Cateterismo Cardíaco/instrumentação , Fatores de Tempo , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Fatores de Risco , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Medição de Risco , Sistema de Registros
20.
Int J Cardiovasc Imaging ; 40(6): 1163-1181, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38780710

RESUMO

Cardiac Computed Tomography (CCT) has become a reliable imaging modality in cardiology providing robust information on the morphology and structure of the heart with high temporal and isotropic spatial resolution. For the past decade, there has been a paradigm shift in the management of valvular heart disease since previously unfavorable candidates for surgery are now provided with less-invasive interventions. Transcatheter heart valve interventions provide a real alternative to medical and surgical management and are often the only treatment option for valvular heart disease patients. Successful transcatheter valve interventions rely on comprehensive multimodality imaging assessment. CCT is the mainstay imaging technique for preprocedural planning of these interventions. CCT is critical in guiding patient selection, choice of procedural access, device selection, procedural guidance, as well as allowing postprocedural follow-up of complications. This article aims to review the current evidence of the role of CCT in the preprocedural planning of patients undergoing transcatheter valvular interventions.


Assuntos
Cateterismo Cardíaco , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Seleção de Pacientes , Valor Preditivo dos Testes , Humanos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/fisiopatologia , Cateterismo Cardíaco/instrumentação , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas , Tomada de Decisão Clínica , Tomografia Computadorizada por Raios X , Valvas Cardíacas/diagnóstico por imagem , Valvas Cardíacas/cirurgia , Valvas Cardíacas/fisiopatologia , Substituição da Valva Aórtica Transcateter/instrumentação , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...