Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.248
Filtrar
1.
Eur J Radiol ; 176: 111524, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38851014

RESUMO

PURPOSE: To assess the accuracy of 0.55 T MRI in diagnosing periprosthetic joint infection (PJI) in patients with symptomatic total hip arthroplasty (THA). MATERIAL AND METHODS: 0.55 T MRI of patients with THA PJI (Group A) and noninfected THA (Group B), including aseptic loosening (Group C, subgroup of B) performed between May 2021 and July 2023 were analysed retrospectively. Two musculoskeletal fellowship-trained radiologists independently identified MRI bone and soft tissue changes including: marrow oedema, periosteal reaction, osteolysis, joint effusion, capsule oedema and thickening, fluid collections, muscle oedema, bursitis, inguinal adenopathy, and muscle tears. The diagnostic performance of MRI discriminators of PJI was evaluated using Fisher's exact test (p < 0.05) and interrater reliability was determined. 61 MRI scans from 60 THA patients (34 female, median age 68, range 41-93 years) in Group A (n = 9; female 4; median age 69, range 56-82 years), B (n = 51; 30; 67.5, 41-93 years), and C (10; 6; 67; 41-82 years) were included. RESULTS: Capsule oedema (sensitivity 89 %, specificity 92 %,), intramuscular oedema (89 %, 82 %) and joint effusion (89 %, 73 %) were the best performing discriminators for PJI diagnosis (p ≤ 0.001), when viewed individually and had combined 70 % sensitivity and 100 % specificity for PJI diagnosis in parallel testing. For the differentiation between PJI and aseptic loosening, intramuscular oedema (89 %, 80 %) and capsule oedema (89 %, 80 %) were significant discriminators (p ≤ 0.001) with combined 64 % sensitivity and 96 % specificity for PJI. CONCLUSIONS: New generation 0.55 T MRI may aid in the detection of PJI in symptomatic patients. Oedema of the joint capsule, adjacent muscles as well as joint effusion were indicative of the presence of PJI.


Assuntos
Imageamento por Ressonância Magnética , Infecções Relacionadas à Prótese , Sensibilidade e Especificidade , Humanos , Feminino , Masculino , Idoso , Imageamento por Ressonância Magnética/métodos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Adulto , Reprodutibilidade dos Testes , Estudos Retrospectivos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Articulação do Quadril/diagnóstico por imagem
3.
Eur J Med Res ; 29(1): 314, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38849967

RESUMO

Conventional radiography is regularly used to evaluate complications after total hip arthroplasty. In various recent consensus meetings, however, plain radiographs of a potentially infected hip joint have been judged as being only relevant to exclude diagnoses other than infection. Solid data on radiographic presentations of periprosthetic joint infection (PJI) are scarce. As a result, the prognostic value of radiological features in low-grade PJI remains uncertain. The present review article aims to present an overview of the available literature and to develop ideas on future perspectives to define the diagnostic possibilities of radiography in PJIs of the hip. The primary outcome of interest of this systematic review was the radiologic presentation of periprosthetic joint infections of the hip. As secondary outcome of interest served the sensitivity and specificity of the radiologic presentation of periprosthetic joint infections. Of the included articles, 26 were reviews, essays, or case reports and only 18 were clinical studies. Typical radiologic abnormalities of PJI were a periosteal reaction, a wide band of radiolucency at the cement-bone or metal-bone interface, patchy osteolysis, implant loosening, bone resorption around the implant, and transcortical sinus tracts. The frequency of their occurrence is still inadequately defined. A deeper understanding of the underlying causes and the relation between microorganisms to radiologic abnormalities can probably help clinicians in the future to diagnose a PJI. This is why further research shall focus on the radiographic features of PJI.


Assuntos
Artroplastia de Quadril , Infecções Relacionadas à Prótese , Humanos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Prognóstico , Artroplastia de Quadril/efeitos adversos , Radiografia/métodos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Prótese de Quadril/efeitos adversos
5.
Card Electrophysiol Clin ; 16(2): 143-147, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749633

RESUMO

We present a complex case of cardiac implantable electronic device infection and extraction in the setting of bacteremia, large lead vegetation, and patent foramen ovale. Following a comprehensive preprocedural workup including transesophageal echocardiogram and computed tomography lead extraction protocol, in addition to the involvement of multiple subspecialties, an open chest approach to extraction was deemed a safer option for eradication of the patient's infection. Despite percutaneous techniques having evolved as the preferred extraction method during the last few decades, this case demonstrates the importance of a thorough evaluation at an experienced center to determine the need for open chest extraction.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Remoção de Dispositivo/métodos , Desfibriladores Implantáveis/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/diagnóstico por imagem , Marca-Passo Artificial/efeitos adversos , Masculino , Ecocardiografia Transesofagiana , Tomografia Computadorizada por Raios X , Idoso , Forame Oval Patente/cirurgia , Forame Oval Patente/diagnóstico por imagem , Feminino , Pessoa de Meia-Idade
6.
Circ Cardiovasc Imaging ; 17(4): e016435, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38626096

RESUMO

Heart valve replacement has steadily increased over the past decades due to improved surgical mortality, an aging population, and the increasing use of transcatheter valve technology. With these developments, prosthetic valve complications, including prosthetic valve endocarditis, are increasingly encountered. In this review, we aim to characterize the manifestations of prosthetic valve endocarditis using representative case studies from our institution to highlight the advances and contributions of modern multimodality imaging techniques.


Assuntos
Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Humanos , Idoso , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/terapia , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite/diagnóstico por imagem , Endocardite/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Imagem Multimodal , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/terapia
7.
J Nucl Cardiol ; 36: 101865, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38679286

RESUMO

BACKGROUND: To identify 18F-fluorodeoxyglucose (FDG) uptake patterns in positron emission tomography/computed tomography (PET/CT) caused by infection, inflammation, surgical material, and/or graft coating. METHODS AND RESULTS: Of 610 consecutive patients with thoracic aortic graft surgery, 60 patients with 187 PET/CT were retrospectively included. We quantified FDG uptake in all grafts using maximum standardized uptake value (SUVmax) alone and in relation to liver background (SUVratio) and determined the uptake pattern. Mixed linear regression models with random slope and intercept were applied for the analysis of SUVratio over time and generalized estimating equations to analyze the associations with anastomosis uptake. FDG uptake was frequently focal (90%), higher in infected than in noninfected grafts (mean SUVratio 2.19; 95% CI 2.05-2.32 vs. 1.63; 1.46-1.79, P < 0.001), and decreasing slowly over time (SUVratio per year since surgery -0.048; 95% CI -0.15- 0.051, P = 0.34), without a difference in slope between infected and noninfected grafts (P = 0.52). There was no evidence of an interaction between SUVratio and use of BioGlue® surgical adhesive (intercept P = 0.73, slope P = 0.71), or graft coating (gelatin and collagen, all P > 0.7). FDG uptake at the anastomosis was more frequent in noninfected grafts than in infected grafts (66% vs. 21%, odds ratio (OR) 11.34; 95% CI 3.61-35.66, P < 0.001). This effect was attenuated by the use of BioGlue® (OR 5.05; 95% CI 0.45-56.9, P = 0.19). CONCLUSIONS: FDG uptake in PET/CT after thoracic aortic graft surgery is higher in infected grafts than in noninfected grafts. In noninfected grafts, focal uptake is also frequent, mostly anastomosis-associated, not associated with graft coating, and possibly affected by the use of BioGlue®.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Humanos , Fluordesoxiglucose F18/farmacocinética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Compostos Radiofarmacêuticos/farmacocinética , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Inflamação/diagnóstico por imagem , Infecções Relacionadas à Prótese/diagnóstico por imagem , Prótese Vascular/efeitos adversos , Aorta Torácica/diagnóstico por imagem , Dissecção da Aorta Torácica
9.
Vasc Endovascular Surg ; 58(6): 655-658, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38491914

RESUMO

BACKGROUND: Vascular graft infection is a very complex disease. Although complete excision of the infected grafts with extra-anatomic bypass or in situ reconstruction is a general treatment strategy, some concerns including reinfection in the new graft remain. CASE REPORT: An 88 year-old man presented to the hospital with abdominal swelling and bleeding. The patient had undergone revascularization for aorto-iliac occlusive disease twice in the past. The first procedure had been performed 15 years previously, with right ilio-femoral bypass grafting for right iliac artery occlusion and stent implantation for left iliac artery stenosis. The second procedure had been performed 10 years previously, with aorta-to-left femoral and left-to-right femoro-femoral bypass grafting because the terminal aorta, the first ilio-femoral bypass graft, and the stent of the left iliac artery had been occluded. The patient was diagnosed with vascular graft infection, and endovascular therapy was selected as the revascularization method prior to graft excision. It was successfully performed using various devices and techniques, followed by graft excision without critical limb ischemia. CONCLUSION: This case demonstrates that endovascular therapy prior to graft excision can be an alternative revascularization method for vascular graft infection after bypass surgery for aorto-iliac occlusive disease.


Assuntos
Doenças da Aorta , Arteriopatias Oclusivas , Implante de Prótese Vascular , Prótese Vascular , Remoção de Dispositivo , Artéria Ilíaca , Infecções Relacionadas à Prótese , Humanos , Masculino , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/diagnóstico por imagem , Resultado do Tratamento , Idoso de 80 Anos ou mais , Artéria Ilíaca/cirurgia , Artéria Ilíaca/diagnóstico por imagem , Doenças da Aorta/cirurgia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/etiologia , Arteriopatias Oclusivas/cirurgia , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/etiologia , Stents , Reoperação , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Angiografia por Tomografia Computadorizada , Aortografia
10.
JACC Cardiovasc Imaging ; 17(6): 669-701, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38466252

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multisocietal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multifocal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Assuntos
Consenso , Técnica Delphi , Fluordesoxiglucose F18 , Leucócitos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Fluordesoxiglucose F18/administração & dosagem , Compostos Radiofarmacêuticos/administração & dosagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/normas , Prognóstico , Infecções Relacionadas à Prótese/diagnóstico por imagem , Reprodutibilidade dos Testes , Endocardite/diagnóstico por imagem , Infecções Cardiovasculares/diagnóstico por imagem , Algoritmos
12.
J Arthroplasty ; 39(4): 1069-1074, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37866461

RESUMO

BACKGROUND: Data regarding the diagnostic value of ultrasound (US)-determined fluid film and joint aspiration prior to revision total hip arthroplasty for suspected periprosthetic joint infections (PJIs) are limited. This study aimed to analyze the value of US-determined fluid film, characterized the preoperative and intraoperative microbiological spectrum and resistance patterns, and compared the concordance between preoperative synovial fluid and intraoperative culture results. METHODS: We analyzed 366 US examinations from 324 patients prior to revision total hip arthroplasty. Selected cases were grouped into clearly infected, noninfected, and inconclusive cohorts, according to the International Consensus Meeting 2018 Criteria. For US-determined fluid film <1 mm, no aspiration was performed based on our institutional protocol. Patients were grouped into no aspiration (144 of 366; [39.3%]), dry tap (21 of 366; [5.7%]), and a successful tap (201 of 366; [54.9%]). The microbiological spectrum and antibiograms were compared between preoperative and intraoperative results. RESULTS: The absence of US-determined fluid film showed no correlation with the presence of a hip PJI. Overall, 31.9% cases of the no-aspiration group had a PJI. In total, 13.5% discrepancies were found between successful taps and intraoperative cultures. The most prevalent microorganisms in preoperative synovial fluid were Staphylococcus epidermidis and Staphylococcus aureus (20.8%), while intraoperatively S. epidermidis (26.3%) and Cutibacterium acnes (14.5%) were leading. Additional microorganisms were identified in 32.5% of intraoperative cultures. There were no differences between resistance patterns of preoperative and intraoperative concordant microorganisms. CONCLUSIONS: Absence of US-determined fluid film cannot rule out the presence of a hip PJI. Combined microbiological results from hip US aspirations and subsequent surgical procedures are crucial to design an effective treatment for suspected hip PJI.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Infecções Relacionadas à Prótese , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Prótese de Quadril/microbiologia , Sensibilidade e Especificidade , Líquido Sinovial , Staphylococcus aureus , Reoperação , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/cirurgia , Estudos Retrospectivos
13.
J Heart Lung Transplant ; 43(4): 529-538, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37951322

RESUMO

BACKGROUND: Previous retrospective studies suggest a good diagnostic performance of 18F-fluorodeoxyglucose positron emission tomography (18F-FDG-PET)/computed tomography (CT) in left ventricular assist device (LVAD) infections. Our aim was to prospectively evaluate the role of PET/CT in the characterization and impact on clinical management of LVAD infections. METHODS: A total of 40 patients (aged 58 [53-62] years) with suspected LVAD infection and 5 controls (aged 69 [64-71] years) underwent 18F-FDG-PET/CT. Four LVAD components were evaluated: exit site and subcutaneous driveline (peripheral), pump pocket, and outflow graft. The location with maximal uptake was considered the presumed site of infection. Infection was confirmed by positive culture (exit site or blood) and/or surgical findings. RESULTS: Visual uptake was present in 40 patients (100%) in the infection group vs 4 (80%) control subjects. For each individual component, the presence of uptake was more frequent in the infection than in the control group. The location of maximal uptake was most frequently the pump pocket (48%) in the infection group and the peripheral components (75%) in the control group. Maximum standard uptake values (SUVmax) were higher in the infection than in the control group: SUVmax (average all components): 6.9 (5.1-8.5) vs 3.8 (3.7-4.3), p = 0.002; SUVmax (location of maximal uptake): 10.6 ± 4.0 vs 5.4 ± 1.9, p = 0.01. Pump pocket infections were more frequent in patients with bacteremia than without bacteremia (79% vs 31%, p = 0.011). Pseudomonas (32%) and methicillin-susceptible Staphylococcus aureus (29%) were the most frequent pathogens and were associated with pump pocket infections, while Staphylococcus epidermis (11%) was associated with peripheral infections. PET/CT affected the clinical management of 83% of patients with infection, resulting in surgical debridement (8%), pump exchange (13%), and upgrade in the transplant listing status (10%), leading to 8% of urgent transplants. CONCLUSIONS: 18F-FDG-PET/CT enables the diagnosis and characterization of the extent of LVAD infections, which can significantly affect the clinical management of these patients.


Assuntos
Bacteriemia , Coração Auxiliar , Infecções Relacionadas à Prótese , Humanos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Coração Auxiliar/efeitos adversos , Tomografia Computadorizada por Raios X , Estudos Retrospectivos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/etiologia , Bacteriemia/diagnóstico , Bacteriemia/etiologia
15.
Ann Vasc Surg ; 98: 325-333, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37536433

RESUMO

BACKGROUND: The aim of this study was to assess the eventual added benefit of antigranulocyte monoclonal antibodies scintigraphy for the diagnostic imaging of aortic graft infection (AGI) and its role in evaluation of treatment outcome. METHODS: A population-based, retrospective, register-based analysis was carried out of all patients with infected aortic grafts after treatment for aneurysmal or aortoiliac occlusive disease at Karolinska University Hospital, covering the greater Stockholm area during November 2012-December 2020. Cases were based on the definitions in the 2016 Management of Aortic Graft Infection Collaborations consensus. Using the in-hospital electronic patient registry (Take Care®) and the Swedish National Registry for Vascular Surgery (Swedvasc), 835 patients who had been treated for aortic aneurysms or aortoiliac occlusive disease were identified. The diagnostic arsenal of laboratory tests, computed tomography (CT), and clinical signs has been supplemented by antigranulocyte monoclonal antibodies (anti-G mAb) scintigraphy. Data were analyzed using SPSS Statistics. RESULTS: Eighteen cases of AGI out of 835 operations incorporating aortic grafts during the period were identified. Fourteen patients (78%) were categorized as diagnosed AGI (AGI-D), and the remaining 4 (22%) were classified as suspected AGI (AGI-S). In the AGI-D group (n = 14), 10 patients (71%) had positive CTs and 4 (29%) had low-probability CTs. In the group of 10 positive CTs, 9 patients also had positive scintigraphy scans with only one negative scintigraphy scan. There were no negative scintigraphy scans without ongoing antibiotic treatment at the time of investigation. In 15 of 18 cases, a culprit agent was identified, either preoperatively or perioperatively. Thirteen of the 18 patients were treated solely by antibiotics, whereas 5 underwent surgical treatment in addition to antibiotic treatment. The outcome has been divided into 3 groups: infection-free (n = 6; 33%), lifelong antibiotic treatment (n = 7; 39%), and deceased (n = 5; 28%). CONCLUSIONS: The imaging modalities in AGI diagnostics are a cornerstone of the investigative work-up, complemented by clinical signs and laboratory methods. The main advantage conveyed by anti-G mAb scintigraphy is in postoperative imaging and its ability to differentiate between infection and general postoperative changes in the areas of concern. We have identified 6 patients in our cohort in whom antibiotic therapy was discontinued after a negative anti-G mAb scintigraphy scan. Anti-G mAb scintigraphy may fulfill a unique need for diagnosis in suspected cases, evaluation of therapeutic efficacy in patients requiring long-term antibiotic treatment, and aiding in the decision to discontinue antibiotic therapy.


Assuntos
Implante de Prótese Vascular , Infecções Relacionadas à Prótese , Humanos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/cirurgia , Resultado do Tratamento , Cintilografia , Antibacterianos/uso terapêutico , Anticorpos Monoclonais/uso terapêutico
16.
BMC Musculoskelet Disord ; 24(1): 889, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37968710

RESUMO

AIM: The aim of this study is to evaluate the functional outcomes and complications after non-fusion knee arthrodesis with a modular segmental intramedullary implant used for infected total knee arthroplasty revisions. METHODS: A retrospective review of the patients who had been surgically treated with a modular intramedullary arthrodesis implant for recurrent infection after revision TKA between January 2016 and February 2020 were included. The indications for arthrodesis were failed infected TKA with massive bone loss, deficient extensor mechanism and poor soft tissue coverage that precluded joint reconstruction with revision TKA implants. Clinical outcomes were assesed with visual analogue scale for pain (pVAS), Oxford knee score (OKS) and 12-item short form survey (SF-12). Full-length radiographs were used to verify limb length discrepancies (LLD). RESULTS: Fourteen patients (4 male and 10 female) patients with a mean age of 69.3 (range, 59 to 81) years at time of surgery were available for final follow-up at a mean of 28.8 months (range, 24-35 months). All clinical outcome scores improved at the final follow-up (pVAS, 8.5 to 2.6, p = .01; OKS, 12.6 to 33.8, p = .02; SF-12 physical, 22.9 to 32.1, p = .01 and SF-12 mental, 27.7 to 40.2, p = .01). The mean LLD was 1.0 cm (range, + 15 - 2.3 cm). Re-infection was detected in three patients (21.4%). Two patients were managed with suppressive antibiotic treatment and a third patient required repeat 2-stage revision procedure. In one patient, a periprosthetic femur fracture was observed and treated with plate osteosynthesis. CONCLUSION: Uncontrolled infection after total knee arthroplasty can be effectively treated with arthrodesis using a modular intramedullary nail and satisfactory functional results can be obtained. LEVEL OF EVIDENCE: Level 4, Retrospective cohort study.


Assuntos
Artrite Infecciosa , Prótese do Joelho , Fraturas Periprotéticas , Infecções Relacionadas à Prótese , Humanos , Masculino , Feminino , Idoso , Estudos Retrospectivos , Reoperação/métodos , Prótese do Joelho/efeitos adversos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Artrodese/efeitos adversos , Artrodese/métodos , Fraturas Periprotéticas/cirurgia , Pinos Ortopédicos/efeitos adversos , Artrite Infecciosa/cirurgia , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Resultado do Tratamento
17.
Nucl Med Rev Cent East Eur ; 26(0): 123-129, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37786949

RESUMO

BACKGROUND: As a result of constantly improving surgical methods, an increasing number of patients have medical devices implanted in the cardiovascular system (including vascular grafts and endografts). Such patients are characterised by their high risk of infectious complications due to the possibility of biofilm formation on implanted material. This work aims to analyse the utility of 2-[18F]FDG PET/CT in diagnosing vascular graft and endograft infections. MATERIAL AND METHODS: The study was undertaken on a group of 58 patients, of whom 34 were in the study group, and 24 were in the control group. The 2-[18F]FDG PET/CT study was conducted in the Nuclear Medicine Department at the University Hospital of Lublin. The inclusion criteria for the study group were the presence of a vascular graft or endograft that encompasses the aorta, and strong clinical suspicion of its infection. The inclusion criteria for the control group were the presence of a vascular graft or endograft in the large arteries and the absence of signs of its infection on 2-[18F]FDG PET/CT, as well as the absence of clinically apparent signs and symptoms during six months of observation after 2-[18F]FDG PET/CT. All patients found in the database that met the criteria were included. RESULTS: Vascular endografts were more common in the control group than in the study group. However, in the case of infection of the vascular endograft, signs of infection in 2-[18F]FDG PET/CT were more severe. Images in the study group were divided into three groups that represent image patterns based on CT and PET characteristics. The first pattern (P1) was recognised in six patients. The second (P2) and third (P3) were visible in 11 and 17 patients, respectively. CONCLUSIONS: Comparative analysis of the study and control groups demonstrates the utility of 2-[18F]FDG PET/CT in the diagnosis of vascular graft/endograft infection.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Infecções Relacionadas à Prótese , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Compostos Radiofarmacêuticos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/efeitos adversos , Tomografia por Emissão de Pósitrons/métodos
18.
BMC Musculoskelet Disord ; 24(1): 801, 2023 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-37814241

RESUMO

PURPOSE: The purpose of this study was to provide a critical systematic review of the role of magnetic resonance imaging (MRI) as a noninvasive method to assess periprosthetic joint infections (PJIs). METHODS: The electronic databases PubMed and EMBASE were searched, since their inception up to March 27, 2022. The included studies evaluated the reproducibility and accuracy of MRI features to diagnose PJIs. The article quality assessment was conducted by the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) and Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). RESULTS: Among 1909 studies identified in the initial search, 8 studies were eligible for final systematic review. The included studies evaluated the reproducibility and accuracy of MRI features to diagnose PJIs. Seven of 8 studies showed good to excellent reliability, but only one article among them in which accuracy was evaluated had a low risk of bias. The intraclass correlation coefficient (ICC) and Cohen coefficient (κ) varied between 0.44 and 1.00. The accuracy varied between 63.9% and 94.4%. Potential MRI features, such as lamellated hyperintense synovitis, edema, fluid collection, or lymphadenopathy, might be valuable for diagnosing PJIs. CONCLUSION: The quality of the evidence regarding the role of MRI for PJIs diagnosis was low. There is preliminary evidence that MRI has a noteworthy value of distinguishing suspected periprosthetic joint infection in patients with total knee arthroplasty or total hip arthroplasty, but the definition of specific MRI features related to PJIs diagnosis lacks consensus and standardization. Large-scale studies with robust quality were required to help make better clinical decisions in the future.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Artroplastia do Joelho , Infecções Relacionadas à Prótese , Humanos , Reprodutibilidade dos Testes , Infecções Relacionadas à Prótese/diagnóstico por imagem , Artroplastia de Quadril/efeitos adversos , Imageamento por Ressonância Magnética
19.
J Orthop Surg Res ; 18(1): 640, 2023 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-37644493

RESUMO

BACKGROUND: American Academy of Orthopaedic Surgeons (AAOS) has provided the guidelines for diagnosing a patient with periprosthetic joint infection including the use of positron emission tomography/computed tomography (PET/CT). Systematic evidence focussing on periprosthetic joint infection (PJI) of hip is limited, which also contains limited number of studies. Hence, the current study aims to perform a pooled analysis of all studies that have assessed the diagnostic accuracy of PET/CT for PJI of hip. METHODS: Searches were done in PubMed Central, EMBASE, MEDLINE, SCOPUS and Cochrane library until December 2022. Meta-analysis was carried out using random-effects model. With 95% confidence intervals (CIs), pooled sensitivity and specificity were reported. RESULTS: Twenty-six studies met the inclusion criteria. The pooled sensitivity of PET/CT was 89% (95% CI 84-93%), while the pooled specificity was 86% (95% CI 79-91%). The AUROC was 0.94 (95% CI 0.72-0.99). There was statistically significant heterogeneity (p < 0.001) with I2 value of 96%. The diagnostic odds ratio was 52 (95% CI 26-106). Likelihood ratio positive was 6.5 (95% CI 4.1-10.3) and negative was 0.13 (95% CI 0.08-0.19). CONCLUSION: Our study found that PET/CT was found to have higher level of accuracy in terms of sensitivity and specificity. Further large-scale research can help to find answers for such questions and provide final conclusive evidence on the inclusion of the imaging modality into the routine clinical practice guidelines for suspected periprosthetic joint infection patients.


Assuntos
Artrite Infecciosa , Infecções Relacionadas à Prótese , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/etiologia , Tomografia por Emissão de Pósitrons , Academias e Institutos
20.
Sensors (Basel) ; 23(13)2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37447649

RESUMO

Prosthetic joint infection (PJI) is a prevalent and severe complication characterized by high diagnostic challenges. Currently, a unified diagnostic standard incorporating both computed tomography (CT) images and numerical text data for PJI remains unestablished, owing to the substantial noise in CT images and the disparity in data volume between CT images and text data. This study introduces a diagnostic method, HGT, based on deep learning and multimodal techniques. It effectively merges features from CT scan images and patients' numerical text data via a Unidirectional Selective Attention (USA) mechanism and a graph convolutional network (GCN)-based Feature Fusion network. We evaluated the proposed method on a custom-built multimodal PJI dataset, assessing its performance through ablation experiments and interpretability evaluations. Our method achieved an accuracy (ACC) of 91.4% and an area under the curve (AUC) of 95.9%, outperforming recent multimodal approaches by 2.9% in ACC and 2.2% in AUC, with a parameter count of only 68 M. Notably, the interpretability results highlighted our model's strong focus and localization capabilities at lesion sites. This proposed method could provide clinicians with additional diagnostic tools to enhance accuracy and efficiency in clinical practice.


Assuntos
Infecções Relacionadas à Prótese , Humanos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Área Sob a Curva , Cultura , Fontes de Energia Elétrica , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...