Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.017
Filtrar
1.
Scand Cardiovasc J ; 58(1): 2418085, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39445438

RESUMO

BACKGROUND: Children with repaired tetralogy of Fallot (rToF) often have pulmonary regurgitation with right ventricular (RV) dilatation and dysfunction, whereas less is known about the effect on the left ventricle (LV). The aim was to investigate LV haemodynamic variables derived from non-invasive pressure-volume loops in children with rToF and how they compare to controls and previous research on adults. MATERIALS AND METHODS: Ten children with rToF and pulmonary regurgitation (12 years [10-13], 6 males) and 10 age- and sex-matched healthy controls (12 years [10-14], 6 males) underwent brachial blood pressure in conjunction with cardiac magnetic resonance imaging. Pressure-volume loops were derived by brachial blood pressure together with LV volumes throughout the cardiac cycle in short-axis cine images yielding several haemodynamic variables, including arterial elastance. The RV endocardial border was delineated in end-diastole and end-systole. RESULTS: Children with rToF and pulmonary regurgitation had larger RV end-diastolic volume (136 [114-156]) than controls (100 [94-112] ml/m2; p = 0.0015) and smaller LV end-diastolic volume (83 [58-91] ml/m2) than controls (101 [92-110] ml/m2; p = 0.002). Arterial elastance was higher in children with rToF (1.5 [1.3-2.7] mmHg/ml) than in controls (1.1 [1.0-1.5] mmHg/ml; p = 0.02). Heart rate was higher in children with rToF (77 [74-81] bpm) than in controls (69 [65-75] bpm; p = 0.027). CONCLUSION: Children with rToF had higher arterial elastance and heart rate than controls, likely due to increased sympathetic tone to compensate for impaired LV filling following pulmonary regurgitation. If this contributes to increased risk of adverse cardiovascular and cerebrovascular events remains to be studied.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Imagem Cinética por Ressonância Magnética , Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Função Ventricular Esquerda , Função Ventricular Direita , Humanos , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/complicações , Masculino , Feminino , Criança , Adolescente , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Estudos de Casos e Controles , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Rigidez Vascular , Valor Preditivo dos Testes , Pressão Arterial , Resultado do Tratamento , Artéria Braquial/fisiopatologia , Artéria Braquial/diagnóstico por imagem , Fatores Etários , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/diagnóstico por imagem , Elasticidade , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/diagnóstico por imagem
2.
PLoS One ; 19(10): e0310700, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39365810

RESUMO

Large-scale analyses of surgical outcomes after surgical pulmonary valve replacement (sPVR) as part of re-do surgery in adults with congenital heart disease (ACHD) are rare. Therefore, we present our outcomes of sPVR in ACHD patients over the last decade and demonstrate our standardized surgical approach. All ACHD patients who underwent sPVR between January 2013 and August 2022 were included. Primary diagnoses, peri-operative data, post-operative echocardiography, pre- and post-operative RV MRI and in-hospital mortality were examined. Pre- and postoperative MRI parameters were compared using paired testing. Standardized surgery was documented. Normality of continuous variables was tested using Shapiro-Wilk test. 79 patients (male 59.5% (n = 47), 71 re-operations (89.9%)) at a median age of 41.7 (52.2-28.8) years were included. Main underlying disease was Tetralogy of Fallot (TOF; n = 47, 59.5%). After removal of degenerated valve/conduit parts, right ventricular outflow tract (RVOT) patch augmentation and implantation of a larger stented bioprosthesis (25mm in 78.5%) were conducted. In 57% of cases, concomitant surgery was performed (mainly tricuspid valve surgery: n = 28, 35.4%). 25 patients (31.6%) were operated with beating heart technique. Echocardiographic outcomes showed no moderate or severe insufficiency (median Vmax of 2 m/s (2.3-1.77 m/s)) upon discharge. Available MRI data showed significantly lower indexed RV-EDV (p = 0.0006) and RV-ESV (P = 0.0017) after surgery. In-hospital mortality was 5.1% (n = 4). SPVR is a safe therapeutic option with low surgical risk and satisfying post-operative results. It can serve as a solid therapeutic option for patients who need future valve-in-valve interventions.


Assuntos
Cardiopatias Congênitas , Implante de Prótese de Valva Cardíaca , Valva Pulmonar , Humanos , Masculino , Feminino , Adulto , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/métodos , Pessoa de Meia-Idade , Cardiopatias Congênitas/cirurgia , Resultado do Tratamento , Ecocardiografia , Mortalidade Hospitalar , Estudos Retrospectivos , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/mortalidade , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Imageamento por Ressonância Magnética
3.
Zhonghua Xin Xue Guan Bing Za Zhi ; 52(10): 1200-1206, 2024 Oct 24.
Artigo em Chinês | MEDLINE | ID: mdl-39428370

RESUMO

Objective: To describe the characteristics, etiology and patterns of outpatients and inpatients patients with moderate or severe valvular heart disease (VHD). Methods: This is a cross-sectional study. Outpatients and inpatients with moderate or severe VHD who underwent transthoracic echocardiography for first examination from 1st January 2001 to 1st January 2020 in Southwest Hospital, Army Medical University were enrolled. Data were collected from medical records and big data platform of Southwest Hospital. Characteristics of age and gender, etiology and types of VHD were descriptively analysed. Results: A total of 68 354 patients with moderate or severe VHD were enrolled. The age was 63 (50, 72) years. And 35 706 (52.24%) patients were female. (1) Age characteristics: There was similar age trend between male and female patients with moderate or severe VHD. The number of patients increased firstly and then decreased and reached its peak in the age group of 65-69 years old. The peak age of mitral stenosis patients was 45-49 years, which was earlier than that of whole patients with moderate or severe VHD. The median age of patients with bicuspid aortic valve was 42 years. (2) Gender characteristics: The proportion of tricuspid regurgitation, pulmonary regurgitation, mitral regurgitation, mitral stenosis and valve surgery in female patients with moderate or severe VHD were higher than those in male patients. The proportion of aortic regurgitation, aortic stenosis and bicuspid aortic valve in male patients with moderate or severe VHD were significantly higher than those in female patients (all P<0.05). (3) Etiology: The proportion of rheumatic VHD was 13.07% (8 934/68 354), which was higher than that of degenerative VHD (0.67% (458/68 354)). (4) Types of VHD: Tricuspid regurgitation made contribution to the largest proportion with 60.72% (41 503/68 354), followed by mitral regurgitation, aortic regurgitation, mitral stenosis, pulmonary regurgitation and aortic stenosis. Conclusions: There are certain regional characteristics in the prevalence of moderate or severe VHD in southwest China, suggesting different attention should be paid on the whole process of refined management of moderate or severe VHD.


Assuntos
Doenças das Valvas Cardíacas , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Transversais , Idoso , Doenças das Valvas Cardíacas/epidemiologia , Ecocardiografia , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Tricúspide/epidemiologia , Insuficiência da Valva Tricúspide/etiologia , Estenose da Valva Mitral/epidemiologia , Adulto , Insuficiência da Valva Pulmonar/epidemiologia
4.
Echocardiography ; 41(10): e15942, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39367769

RESUMO

BACKGROUND: Tetralogy of Fallot with an absent pulmonary valve is a very rare variant of tetralogy. It is characterized by absent valve tissue, severe pulmonary regurgitation, and secondary aneurysmal dilatation of the pulmonary arteries. AIM: In this study, we aim to investigate the clinical presentations, management strategies, and outcomes of patients with tetralogy of Fallot and absent pulmonary valve. METHODOLOGY: We retrospectively reviewed the charts of all patients who presented to the American University of Beirut Medical Center between January 2010 and December 2020 and who were diagnosed with this anomaly. RESULTS: A total of 300 cases of tetralogy of Fallot were identified, of which 18 patients had absent pulmonary valves. They were followed up for an average of 8.2 years. Prenatal diagnoses were made in four patients, while 13 patients were identified in the neonatal period, with an average age of 4.5 days. Genetic testing confirmed DiGeorge syndrome in one patient. Five patients underwent surgical intervention in the neonatal period, while the remaining patients were operated on during their early childhood. While overall there were no surgical mortalities nor any need for reinterventions, a variety of morbidities were encountered. CONCLUSION: This study provides an overview of this rare anomaly and its management in a developing country.


Assuntos
Países em Desenvolvimento , Valva Pulmonar , Centros de Atenção Terciária , Tetralogia de Fallot , Humanos , Tetralogia de Fallot/cirurgia , Feminino , Estudos Retrospectivos , Masculino , Valva Pulmonar/anormalidades , Valva Pulmonar/diagnóstico por imagem , Recém-Nascido , Ecocardiografia/métodos , Lactente , Insuficiência da Valva Pulmonar/diagnóstico
5.
G Ital Cardiol (Rome) ; 25(11): 833-840, 2024 Nov.
Artigo em Italiano | MEDLINE | ID: mdl-39450463

RESUMO

BACKGROUND: The long-term complications arising from chronic pulmonary insufficiency after surgical correction of tetralogy of Fallot (TOF) are well documented. In our center, innovative techniques for pulmonary valve (PV) preservation have been adopted and developed for over 10 years. METHODS: All patients with TOF and PV stenosis who underwent surgery at our center between January 2008 and December 2022 were included in this study. Patients were evaluated using echocardiography during follow-up, comparing those who underwent classic surgery with transannular patch (TAP) placement and those who underwent PV preservation techniques. RESULTS: Of the 134 patients, 99 (73.9%) were successfully treated using PV preservation techniques. At the time of surgery, the median age was 4.3 months (interquartile range [IQR] 3.4-5.9 months). The median preoperative PV z-score was -2.87 (IQR -3.61;-2.48). The median follow-up time from surgery was 6.6 years (IQR 3.5-8.4 years). During the median follow-up, the right ventricular area change fraction was 47% (IQR 43-50%) in patients treated with PV preservation and 43% (IQR 41-47%) in the TAP group (p=0.005). These data were associated with better PV function in patients treated with preservation. Specifically, insufficiency was mild in 12%, moderate in 35%, and severe in 53% of patients in the TAP group. Conversely, insufficiency was mild in 53%, moderate in 35%, and severe in 11% of patients treated with preservation (p<0.001). CONCLUSIONS: Annular integrity and PV function can be preserved during early TOF correction. PV preservation can prevent the long-term development of pulmonary insufficiency and right ventricular dysfunction.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia , Insuficiência da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Humanos , Tetralogia de Fallot/cirurgia , Valva Pulmonar/cirurgia , Lactente , Feminino , Masculino , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Seguimentos , Resultado do Tratamento , Estenose da Valva Pulmonar/cirurgia , Estudos Retrospectivos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia
6.
JACC Cardiovasc Interv ; 17(19): 2287-2297, 2024 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-39415386

RESUMO

BACKGROUND: A dilated native right ventricular outflow tract (RVOT) presents unique challenges for transcatheter management using balloon-expandable valves. The Alterra Adaptive Prestent was designed to expand transcatheter therapy to treat patients with dilated RVOTs. OBJECTIVES: The aim of this study was to report 2-year outcomes of the main cohort of the ALTERRA (Multicenter Study of Congenital Pulmonic Valve Dysfunction Studying the SAPIEN 3 THV With the Alterra Adaptive Prestent) pivotal trial using the prestent with transcatheter pulmonary valve replacement. METHODS: The prestent device used with the 29 mm SAPIEN 3 transcatheter heart valve (THV) was evaluated for the management of patients with moderate or greater pulmonary valve regurgitation (PR). The primary endpoint was THV dysfunction at 6 months, defined as a nonhierarchical composite of RVOT/pulmonary valve reintervention, moderate or greater total PR on transthoracic echocardiography, and mean RVOT/pulmonary valve gradient 35 mm Hg or greater on transthoracic echocardiography. The primary endpoint and outcomes through 2 years are presented in this analysis. RESULTS: Of 97 patients screened, 60 underwent prestent and THV implantation. There was 1 staged procedure. No patients had THV dysfunction at 6 months. At 2 years, the majority of patients (92.5%) had mild or less PR, with no reports of coronary compression, stent fractures warranting reintervention, or endocarditis. Of the 21 patients (34.4%) who experienced early (days 0-1) arrhythmias, 12 had episodes of nonsustained ventricular tachycardia that resolved with medication. One patient underwent reintervention secondary to an iatrogenic RVOT obstruction; there were no deaths or explantations through 2 years. CONCLUSIONS: The Alterra prestent in combination with the SAPIEN 3 THV has excellent outcomes at 2 years, with no significant valve dysfunction in the main pivotal cohort.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Desenho de Prótese , Insuficiência da Valva Pulmonar , Valva Pulmonar , Recuperação de Função Fisiológica , Humanos , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Resultado do Tratamento , Masculino , Feminino , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Fatores de Tempo , Valva Pulmonar/fisiopatologia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Adulto , Estados Unidos , Adulto Jovem , Hemodinâmica , Adolescente , Estudos Prospectivos , Pessoa de Meia-Idade , Valvuloplastia com Balão/efeitos adversos , Fatores de Risco , Europa (Continente)
9.
Am J Cardiol ; 229: 36-46, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-39147304

RESUMO

Transcatheter pulmonary valve replacement (TPVR) is now frequently performed in patients with adult congenital heart disease. As the life expectancy of the population with adult congenital heart disease continues to improve, more patients will require pulmonary valve intervention. This study details the short-term and midterm clinical outcomes of patients aged ≥40 years who underwent TPVR. We performed an institutional retrospective cohort study that included patients aged ≥40 years who underwent TPVR (and clinical follow-up) from January 1, 2012 to January 1, 2024. Descriptive analyses, Kaplan-Meier survival analysis, and Cox proportional hazard modeling were used to determine outcomes and risk factors affecting survival. The study included 67 patients, and median age at TPVR was 48 years (43 to 57). Median hospital length of stay after TPVR was 1 day (1 to 3); periprocedural complications occurred in 5 patients, and acute kidney injury occurred in 1 patient. Median duration of follow-up was 3.5 years (0.1 to 9.7). There were 9 total deaths, and 1-, 3-, and 5-year Kaplan-Meier survival after TPVR was 95%, 91%, and 82%, respectively. Moderate or worse right ventricular dysfunction was present in 22 patients before TPVR and in 20 patients after TPVR. Inpatient status before TPVR negatively affected survival (hazard ratio 24.7, 3.3 to 186.1, p = 0.002). In conclusion, TPVR was performed in patients aged ≥40 years with favorable periprocedural and midterm follow-up outcomes including survival, but right ventricular dysfunction did not improve, and further exploration of the ideal timing of TPVR in this age group is warranted.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Valva Pulmonar , Humanos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Implante de Prótese de Valva Cardíaca/métodos , Adulto , Valva Pulmonar/cirurgia , Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/cirurgia , Insuficiência da Valva Pulmonar/cirurgia , Taxa de Sobrevida/tendências , Seguimentos , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco , Resultado do Tratamento , Tempo de Internação/estatística & dados numéricos , Estimativa de Kaplan-Meier , Modelos de Riscos Proporcionais
10.
J Cardiothorac Surg ; 19(1): 427, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38982433

RESUMO

INTRODUCTION: Pulmonary regurgitation (PR) remains a common sequela in patients following surgically corrected TOF, and may lead to progressive right ventricle dilatation and dysfunction. The conventional approach of redo-sternotomy for pulmonary valve replacement (PVR) is associated with increased operative time as well as risks of bleeding and injury to the heart and great vessels. Thus, left anterior mini-thoracotomy has become an alternative approach in eliminating the risks of redo-sternotomy in these patients. This series aimed to determine the outcomes of minimally invasive pulmonary valve replacement after surgical TOF correction. METHODS: A retrospective analysis was conducted on 24 patients with severe PR post-surgical TOF correction who underwent left anterior mini-thoracotomy PVR in Penang General Hospital from January 2021 to January 2023. RESULTS: The median age was 23.5 years (I.Q.range 17.6-36.3), with a male:female ratio of 1:4. Majority of patients had mild to moderate symptoms prior to surgery and 19 patients (79.1%) were on regular diuretics medication. All patients had severe free-flow PR with evidence of right ventricular dilatation and dysfunction. Magnetic Resonance Imaging and computed tomography of pulmonary artery were performed prior to surgery. Minimally invasive PVR was performed on all patients via left upper anterior mini-thoracotomy and femoral-femoral bypass without cardioplegic arrest. The operative time and cardiopulmonary bypass time were 208 (I.Q.range 172-324) and 98.6 minutes(I.Q.range 87.4-152.4) respectively. The time to wean off inotropes postoperatively was 6.2 hours (I.Q.range1.4-14.8), and no postoperative arrhythmia and chest re-exploration were reported. Most patients stayed in Intensive Care Unit (ICU) for 10.8 hours (I.Q.range 8.4-36.5), and the total hospital stay was 4.2 days (I.Q.range 3.4-7.6). 2 patients (11.1%) required blood transfusion postoperative. There was no paravalvular leak and no mortality during the follow-up period of up to 28 months. CONCLUSION: Minimally invasive PVR after surgical correction of TOF is a safe alternative to the conventional redo-sternotomy approach in patients with favorable anatomy. This approach is able to reduce the risks associated with redo-sternotomy, particularly bleeding and injury to mediastinal structures, with the additional benefit of expedited recovery and hospital discharge. Our series has shown a safe and efficient approach in these patients with favorable outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Toracotomia , Humanos , Masculino , Feminino , Tetralogia de Fallot/cirurgia , Estudos Retrospectivos , Adulto , Toracotomia/métodos , Adolescente , Implante de Prótese de Valva Cardíaca/métodos , Adulto Jovem , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Valva Pulmonar/cirurgia , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 104(2): 256-263, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38967206

RESUMO

BACKGROUND: The Alterra adaptive prestent is a novel self-expanding device designed to provide a landing zone for the 29 mm SAPIEN 3 valve to treat pulmonary regurgitation in patients with a right ventricular outflow tract that is too large for a balloon expandable valve alone. The mechanism of fixation for the Alterra prestent is radial force from the self-expanding stent frame, combined with a unique set of flared "tines" that protrude from both ends of the stent. AIMS, METHODS, AND RESULTS: In this report, we describe 6 patients who underwent uncomplicated transcatheter pulmonary valve replacement with an Alterra adaptive prestent and SAPIEN 3 valve and had surveillance chest computed tomography (CT) scans performed 1 day to 21 months after implant. In each patient, the CT scan demonstrated extravascular extension of a portion of the Alterra prestent, without clinical sequelae, but with extension into the ascending aorta in 1 patient and contact with the ascending aorta, left pulmonary vein, or left atrial appendage in 3 others. CONCLUSIONS: Surveillance CT imaging shows that the Alterra prestent can perforate the pulmonary artery and/or right ventricle. Although no sequelae were seen in these patients, prestent perforation has the potential to be clinically important. Implanters should be aware of this finding and its potential implications. As experience with the Alterra prestent grows, it will be important to further define the risk factors, incidence, and implications of this phenomenon.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valor Preditivo dos Testes , Desenho de Prótese , Humanos , Masculino , Feminino , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Fatores de Tempo , Adulto , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Adulto Jovem , Angiografia por Tomografia Computadorizada , Adolescente , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Tomografia Computadorizada por Raios X
12.
Arq Bras Cardiol ; 121(7): e20230585, 2024 Jun.
Artigo em Português, Inglês | MEDLINE | ID: mdl-39082573

RESUMO

BACKGROUND: Pulmonary valve regurgitation is a significant long-term complication in patients with tetralogy of Fallot (TOF). OBJECTIVE: This study aims to investigate the effects of pulmonary valve implantation (PVI) on the anatomy and function of the right ventricle (RV) and the long-term evolution of the implanted prosthesis in the pulmonary position. METHODS: A single-center retrospective cohort analysis was performed in 56 consecutive patients with TOF who underwent PVI. The study included patients of both sexes, aged ≥ 12 years, and involved assessing clinical and surgical data, pre- and post-operative cardiovascular magnetic resonance imaging, and echocardiogram data more than 1 year after PVI. RESULTS: After PVI, there was a significant decrease in RV end-systolic volume indexed by body surface area (BSA), from 89 mL/BSA to 69 mL/BSA (p < 0.001) and indexed RV end-diastolic volume, from 157 mL/BSA to 116 mL/BSA (p < 0.001). Moreover, there was an increase in corrected RV ejection fraction [ RVEFC = net pulmonary flow (pulmonary forward flow - regurgitant flow) / R V end-diastolic volume ] from 23% to 35% (p < 0.001) and left ventricular ejection fraction from 58% to 60% (p = 0.008). However, a progressive increase in the peak pulmonary valve gradient was observed over time, with 25% of patients experiencing a gradient exceeding 60 mmHg. Smaller prostheses (sizes 19 to 23) were associated with a 4.3-fold higher risk of a gradient > 60 mmHg compared to larger prostheses (sizes 25 to 27; p = 0.029; confidence interval: 1.18 to 17.8). CONCLUSION: As expected, PVI demonstrated improvements in RV volumes and function. Long-term follow-up and surveillance are crucial for assessing the durability of the prosthesis and detecting potential complications. Proper sizing of prostheses is essential for improved prosthesis longevity.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Humanos , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/diagnóstico por imagem , Masculino , Feminino , Estudos Retrospectivos , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Resultado do Tratamento , Adulto , Adolescente , Adulto Jovem , Fatores de Tempo , Criança , Ecocardiografia , Função Ventricular Direita/fisiologia , Volume Sistólico/fisiologia , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Período Pós-Operatório
14.
J Am Heart Assoc ; 13(14): e034833, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-38958134

RESUMO

BACKGROUND: There are limited data about the impact of timing of pulmonary valve replacement (PVR) on right heart reverse remodeling in patients with pulmonary regurgitation following intervention for isolated pulmonary valve stenosis (PS). This study compared differences in postprocedural right heart reverse remodeling after early versus late PVR (defined as PVR before versus after attainment of the conservative consensus criteria proposed by Bokma et al, 2018) in patients with prior intervention for PS, using patients with tetralogy of Fallot as the reference group. METHOD AND RESULTS: Right atrial reservoir strain and right ventricular free wall strain was measured at baseline, 1 and 3 years after PVR. There were 114 patients with PS (early PVR, 87 [76%]; late PVR, 27 [24%]) and 291 patients with tetralogy of Fallot (early PVR, 197 [67%]; late PVR, 96 [33%]). The PS group had greater improvement in right atrial reservoir strain at 1 year (12%±4% versus 8%±4%; P<0.001) and 3 years (15%±6% versus 9%±6%; P<0.001), and a greater improvement in right ventricular free wall strain at 1 year (12%±4% versus 7%±3%, P=0.008) and 3-years (16%±6% versus 12%±5%; P=0.01) after PVR compared with the tetralogy of Fallot group. There was no difference in right heart reverse remodeling between patients who underwent early versus later PVR within the PS group. In contrast, late PVR was associated with less right heart reverse remodeling within the tetralogy of Fallot group. CONCLUSIONS: These data suggest that patients with palliated PS presenting pulmonary regurgitation have a more benign clinical course, and hence delaying PVR in this population may be appropriate.


Assuntos
Implante de Prótese de Valva Cardíaca , Estenose da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Função Ventricular Direita , Remodelação Ventricular , Humanos , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/complicações , Estenose da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/complicações , Masculino , Feminino , Função Ventricular Direita/fisiologia , Valva Pulmonar/cirurgia , Valva Pulmonar/fisiopatologia , Adulto , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Resultado do Tratamento , Adulto Jovem , Fatores de Tempo , Estudos Retrospectivos , Adolescente
16.
BMC Cardiovasc Disord ; 24(1): 301, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872098

RESUMO

BACKGROUND: Studies of transcatheter pulmonary valve replacement (TPVR) with the Melody valve have demonstrated good clinical and hemodynamic outcomes. Our study analyzes the midterm clinical and hemodynamic outcomes for patients who underwent Melody valve implantation in Southeast Asia. METHODS: Patients with circumferential conduits or bioprosthetic valves and experiencing post-operative right ventricular outflow tract (RVOT) dysfunction were recruited for Melody TPVR. RESULTS: Our cohort (n = 14) was evenly divided between pediatric and adult patients. The median age was 19 years (8-38 years), a male-to-female ratio of 6:1 with a median follow-up period of 48 months (16-79 months), and the smallest patient was an 8-year-old boy weighing 18 kg. All TPVR procedures were uneventful and successful with no immediate mortality or conduit rupture. The primary implant indication was combined stenosis and regurgitation. The average conduit diameter was 21 ± 2.3 mm. Concomitant pre-stenting was done in 71.4% of the patients without Melody valve stent fractures (MSFs). Implanted valve size included 22-mm (64.3%), 20-mm (14.3%), and 18-mm (21.4%). After TPVR, the mean gradient across the RVOT was significantly reduced from 41 mmHg (10-48 mmHg) to 16 mmHg (6-35 mmHg) at discharge, p < 0.01. Late follow-up infective endocarditis (IE) was diagnosed in 2 patients (14.3%). Overall freedom from IE was 86% at 79 months follow-up. Three patients (21.4%) developed progressive RVOT gradients. CONCLUSION: For patients in Southeast Asia with RVOT dysfunction, Melody TPVR outcomes are similar to those reported for patients in the US in terms of hemodynamic and clinical improvements. A pre-stenting strategy was adopted and no MSFs were observed. Post-implantation residual stenosis and progressive stenosis of the RVOT require long term monitoring and reintervention. Lastly, IE remained a concern despite vigorous prevention and peri-procedural bacterial endocarditis prophylaxis.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Valva Pulmonar , Recuperação de Função Fisiológica , Humanos , Masculino , Criança , Feminino , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Adolescente , Valva Pulmonar/cirurgia , Valva Pulmonar/fisiopatologia , Valva Pulmonar/diagnóstico por imagem , Resultado do Tratamento , Adulto Jovem , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Fatores de Tempo , Adulto , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Bioprótese , Estenose da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Sudeste Asiático
17.
Interv Cardiol Clin ; 13(3): 369-384, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38839170

RESUMO

Over the last 2 decades, experience with transcatheter pulmonary valve replacement (TPVR) has grown significantly and has become an effective and reliable way of treating pulmonary valve regurgitation, right ventricular outflow (RVOT) obstruction, and dysfunctional bioprosthetic valves and conduits. With the introduction of self-expanding valves and prestents, dilated native RVOT can be addressed with the transcatheter approach. In this article, the authors review the current practices, technical challenges, and outcomes of TPVR.


Assuntos
Cateterismo Cardíaco , Cardiopatias Congênitas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Pulmonar/cirurgia , Cardiopatias Congênitas/cirurgia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico , Obstrução do Fluxo Ventricular Externo/cirurgia , Desenho de Prótese , Bioprótese
19.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38597297

RESUMO

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Assuntos
Cateterismo Cardíaco , Análise de Elementos Finitos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Desenho de Prótese , Valva Pulmonar , Humanos , Valva Pulmonar/fisiopatologia , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Medição de Risco , Adolescente , Resultado do Tratamento , Fatores de Risco , Masculino , Criança , Estudos Retrospectivos , Feminino , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Adulto Jovem , Valor Preditivo dos Testes , Hemodinâmica , Stents , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Tomada de Decisão Clínica , Adulto
20.
J Am Coll Cardiol ; 83(14): 1310-1321, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38569760

RESUMO

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021. OBJECTIVES: In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience. METHODS: This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S. CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention. RESULTS: A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2). CONCLUSIONS: In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Adulto , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Sistema de Registros , Desenho de Prótese , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...