Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 508
Filtrar
1.
Arq Bras Cardiol ; 121(7): e20230585, 2024 Jun.
Artigo em Português, Inglês | MEDLINE | ID: mdl-39082573

RESUMO

BACKGROUND: Pulmonary valve regurgitation is a significant long-term complication in patients with tetralogy of Fallot (TOF). OBJECTIVE: This study aims to investigate the effects of pulmonary valve implantation (PVI) on the anatomy and function of the right ventricle (RV) and the long-term evolution of the implanted prosthesis in the pulmonary position. METHODS: A single-center retrospective cohort analysis was performed in 56 consecutive patients with TOF who underwent PVI. The study included patients of both sexes, aged ≥ 12 years, and involved assessing clinical and surgical data, pre- and post-operative cardiovascular magnetic resonance imaging, and echocardiogram data more than 1 year after PVI. RESULTS: After PVI, there was a significant decrease in RV end-systolic volume indexed by body surface area (BSA), from 89 mL/BSA to 69 mL/BSA (p < 0.001) and indexed RV end-diastolic volume, from 157 mL/BSA to 116 mL/BSA (p < 0.001). Moreover, there was an increase in corrected RV ejection fraction [ RVEFC = net pulmonary flow (pulmonary forward flow - regurgitant flow) / R V end-diastolic volume ] from 23% to 35% (p < 0.001) and left ventricular ejection fraction from 58% to 60% (p = 0.008). However, a progressive increase in the peak pulmonary valve gradient was observed over time, with 25% of patients experiencing a gradient exceeding 60 mmHg. Smaller prostheses (sizes 19 to 23) were associated with a 4.3-fold higher risk of a gradient > 60 mmHg compared to larger prostheses (sizes 25 to 27; p = 0.029; confidence interval: 1.18 to 17.8). CONCLUSION: As expected, PVI demonstrated improvements in RV volumes and function. Long-term follow-up and surveillance are crucial for assessing the durability of the prosthesis and detecting potential complications. Proper sizing of prostheses is essential for improved prosthesis longevity.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Humanos , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/diagnóstico por imagem , Masculino , Feminino , Estudos Retrospectivos , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Resultado do Tratamento , Adulto , Adolescente , Adulto Jovem , Fatores de Tempo , Criança , Ecocardiografia , Função Ventricular Direita/fisiologia , Volume Sistólico/fisiologia , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Período Pós-Operatório
2.
Catheter Cardiovasc Interv ; 104(2): 256-263, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38967206

RESUMO

BACKGROUND: The Alterra adaptive prestent is a novel self-expanding device designed to provide a landing zone for the 29 mm SAPIEN 3 valve to treat pulmonary regurgitation in patients with a right ventricular outflow tract that is too large for a balloon expandable valve alone. The mechanism of fixation for the Alterra prestent is radial force from the self-expanding stent frame, combined with a unique set of flared "tines" that protrude from both ends of the stent. AIMS, METHODS, AND RESULTS: In this report, we describe 6 patients who underwent uncomplicated transcatheter pulmonary valve replacement with an Alterra adaptive prestent and SAPIEN 3 valve and had surveillance chest computed tomography (CT) scans performed 1 day to 21 months after implant. In each patient, the CT scan demonstrated extravascular extension of a portion of the Alterra prestent, without clinical sequelae, but with extension into the ascending aorta in 1 patient and contact with the ascending aorta, left pulmonary vein, or left atrial appendage in 3 others. CONCLUSIONS: Surveillance CT imaging shows that the Alterra prestent can perforate the pulmonary artery and/or right ventricle. Although no sequelae were seen in these patients, prestent perforation has the potential to be clinically important. Implanters should be aware of this finding and its potential implications. As experience with the Alterra prestent grows, it will be important to further define the risk factors, incidence, and implications of this phenomenon.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valor Preditivo dos Testes , Desenho de Prótese , Humanos , Masculino , Feminino , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Fatores de Tempo , Adulto , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Adulto Jovem , Angiografia por Tomografia Computadorizada , Adolescente , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Tomografia Computadorizada por Raios X
5.
BMC Cardiovasc Disord ; 24(1): 301, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872098

RESUMO

BACKGROUND: Studies of transcatheter pulmonary valve replacement (TPVR) with the Melody valve have demonstrated good clinical and hemodynamic outcomes. Our study analyzes the midterm clinical and hemodynamic outcomes for patients who underwent Melody valve implantation in Southeast Asia. METHODS: Patients with circumferential conduits or bioprosthetic valves and experiencing post-operative right ventricular outflow tract (RVOT) dysfunction were recruited for Melody TPVR. RESULTS: Our cohort (n = 14) was evenly divided between pediatric and adult patients. The median age was 19 years (8-38 years), a male-to-female ratio of 6:1 with a median follow-up period of 48 months (16-79 months), and the smallest patient was an 8-year-old boy weighing 18 kg. All TPVR procedures were uneventful and successful with no immediate mortality or conduit rupture. The primary implant indication was combined stenosis and regurgitation. The average conduit diameter was 21 ± 2.3 mm. Concomitant pre-stenting was done in 71.4% of the patients without Melody valve stent fractures (MSFs). Implanted valve size included 22-mm (64.3%), 20-mm (14.3%), and 18-mm (21.4%). After TPVR, the mean gradient across the RVOT was significantly reduced from 41 mmHg (10-48 mmHg) to 16 mmHg (6-35 mmHg) at discharge, p < 0.01. Late follow-up infective endocarditis (IE) was diagnosed in 2 patients (14.3%). Overall freedom from IE was 86% at 79 months follow-up. Three patients (21.4%) developed progressive RVOT gradients. CONCLUSION: For patients in Southeast Asia with RVOT dysfunction, Melody TPVR outcomes are similar to those reported for patients in the US in terms of hemodynamic and clinical improvements. A pre-stenting strategy was adopted and no MSFs were observed. Post-implantation residual stenosis and progressive stenosis of the RVOT require long term monitoring and reintervention. Lastly, IE remained a concern despite vigorous prevention and peri-procedural bacterial endocarditis prophylaxis.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Valva Pulmonar , Recuperação de Função Fisiológica , Humanos , Masculino , Criança , Feminino , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Adolescente , Valva Pulmonar/cirurgia , Valva Pulmonar/fisiopatologia , Valva Pulmonar/diagnóstico por imagem , Resultado do Tratamento , Adulto Jovem , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Fatores de Tempo , Adulto , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Bioprótese , Estenose da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Sudeste Asiático
7.
J Vet Cardiol ; 53: 52-59, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38688090

RESUMO

Transcatheter pulmonary valve implantation (TPVI) is indicated for use in the management of failing pulmonary valves in humans. We report here the long-term follow-up of the first documented transcatheter pulmonary valve implanted in a client-owned dog. A one-year-old Beagle dog with severe congenital type A valvular pulmonic stenosis first underwent percutaneous balloon pulmonary valvuloplasty, leading two years later to severe pulmonary regurgitation. A TPVI using a Melody™ bioprosthetic valve was then successfully performed, with normalization of the right heart cavities. Repeated two- and three-dimensional transthoracic echocardiographic examinations combined with Doppler modes confirmed the appropriate position and function of the valve for four years. Mitral myxomatous valvular degeneration led to refractory left-sided congestive heart failure, and the dog was humanely euthanized. After postmortem examination, X-ray imaging and histopathological evaluation of the stent and the valve were performed. Ex-vivo imaging of the implanted valve using a Faxitron® Path radiography system and microscopic evaluation of the implanted stent and bioprosthetic leaflets did not show any relevant leaflet or stent alterations. This case provides a proof of concept in interventional veterinary cardiology, showing that TPVI can be performed in dogs with subsequent long-term maintaining normal pulmonary valve function.


Assuntos
Doenças do Cão , Implante de Prótese de Valva Cardíaca , Estenose da Valva Pulmonar , Valva Pulmonar , Animais , Cães , Doenças do Cão/cirurgia , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/patologia , Estenose da Valva Pulmonar/veterinária , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/patologia , Implante de Prótese de Valva Cardíaca/veterinária , Implante de Prótese de Valva Cardíaca/instrumentação , Ecocardiografia Tridimensional/veterinária , Insuficiência da Valva Pulmonar/veterinária , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Ecocardiografia/veterinária , Bioprótese/veterinária , Masculino , Próteses Valvulares Cardíacas/veterinária , Feminino
8.
Int J Cardiovasc Imaging ; 40(5): 1135-1147, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38668927

RESUMO

Repaired Tetralogy of Fallot (rTOF) patients suffer from pulmonary regurgitation and may require pulmonary valve replacement (PVR). Cardiac magnetic resonance imaging (cMRI) guides therapy, but conventional measurements do not quantify the intracardiac flow effects from pulmonary regurgitation or PVR. This study investigates intracardiac flow parameters of the right ventricle (RV) of rTOF by computational fluid dynamics (CFD). cMRI of rTOF patients and controls were retrospectively included. Feature-tracking captured RV endocardial contours from long-axis/short-axis cine. Ventricular motion was reconstructed via diffeomorphic mapping, serving as domain boundary for CFD simulations. Vorticity (1/s), viscous energy loss (ELoss, mJ/L) and turbulent kinetic energy (TKE, mJ/L) were quantified in RV outflow tract (RVOT) and RV inflow. These parameters were normalized against total RV kinetic energy (KE) and RV inflow vorticity to derive dimensionless metrics. Vorticity contours by Q-criterion were qualitatively compared. rTOF patients (n = 15) had mean regurgitant fraction 38 ± 12% and RV size 162 ± 35 mL/m2. Compared to controls (n = 12), rTOF had increased RVOT vorticity (142.6 ± 75.6/s vs. 40.4 ± 11.8/s, p < 0.0001), Eloss (55.6 ± 42.5 vs. 5.2 ± 4.4 mJ/L, p = 0.0004), and TKE (5.7 ± 5.9 vs. 0.84 ± 0.46 mJ/L, p = 0.0003). After PVR, there was decrease in normalized RVOT Eloss/TKE (p = 0.0009, p = 0.029) and increase in normalized tricuspid inflow vorticity/KE (p = 0.0136, p = 0.043), corresponding to reorganization of the "donut"-shaped tricuspid ring-vortex. The intracardiac flow in rTOF patients can be simulated to determine the impact of PVR and improve the clinical indications guided by cardiac imaging.


Assuntos
Hemodinâmica , Hidrodinâmica , Imagem Cinética por Ressonância Magnética , Modelos Cardiovasculares , Valor Preditivo dos Testes , Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Função Ventricular Direita , Humanos , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/diagnóstico por imagem , Feminino , Masculino , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Estudos Retrospectivos , Cinética , Adulto , Adulto Jovem , Velocidade do Fluxo Sanguíneo , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Modelagem Computacional Específica para o Paciente , Adolescente
9.
Circ Cardiovasc Interv ; 17(5): e013889, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38606564

RESUMO

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Desenho de Prótese , Valva Pulmonar , Humanos , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Masculino , Feminino , Adolescente , Adulto Jovem , Criança , Adulto , Estudos Retrospectivos , Valor Preditivo dos Testes , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Seleção de Pacientes , Tomada de Decisão Clínica , Recuperação de Função Fisiológica , Hemodinâmica
10.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38597297

RESUMO

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Assuntos
Cateterismo Cardíaco , Análise de Elementos Finitos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Desenho de Prótese , Valva Pulmonar , Humanos , Valva Pulmonar/fisiopatologia , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Medição de Risco , Adolescente , Resultado do Tratamento , Fatores de Risco , Masculino , Criança , Estudos Retrospectivos , Feminino , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Adulto Jovem , Valor Preditivo dos Testes , Hemodinâmica , Stents , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Tomada de Decisão Clínica , Adulto
11.
Int J Cardiovasc Imaging ; 40(5): 1123-1134, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38536607

RESUMO

Right ventricular (RV) diastolic stiffness is an independent predictor of survival and is strongly associated with disease severity in patients with precapillary pulmonary hypertension (PH). Therefore, a fully validated echocardiographic method for assessing RV diastolic stiffness needs to be established. This study aimed to compare echocardiography-derived RV diastolic stiffness and invasively measured pressure-volume loop-derived RV diastolic stiffness in patients with precapillary PH. We studied 50 consecutive patients with suspected or confirmed precapillary PH who underwent cardiac catheterization, magnetic resonance imaging, and echocardiography within a 1-week interval. Single-beat RV pressure-volume analysis was performed to determine the gold standard for RV diastolic stiffness. Elevated RV end-diastolic pressure (RVEDP) was defined as RVEDP ≥ 8 mmHg. Using continuous-wave Doppler and M-mode echocardiography, an echocardiographic index of RV diastolic stiffness was calculated as the ratio of the atrial-systolic descent of the pulmonary artery-RV pressure gradient derived from pulmonary regurgitant velocity (PRPGDAC) to the tricuspid annular plane movement during atrial contraction (TAPMAC). PRPGDAC/TAPMAC showed significant correlation with ß (r = 0.54, p < 0.001) and RVEDP (r = 0.61, p < 0.001). A cut-off value of 0.74 mmHg/mm for PRPGDAC/TAPMAC showed 83% sensitivity and 93% specificity for identifying elevated RVEDP. Multivariate analyses indicated that PRPGDAC/TAPMAC was independently associated with disease severity in patients with precapillary PH, including substantial PH symptoms, stroke volume index, right atrial size, and pressure. PRPGDAC/TAPMAC, based on pulmonary regurgitation velocity waveform analysis, is useful for the noninvasive assessment of RV diastolic stiffness and is associated with prognostic risk factors in precapillary PH.


Assuntos
Cateterismo Cardíaco , Diástole , Ecocardiografia Doppler , Hipertensão Pulmonar , Valor Preditivo dos Testes , Insuficiência da Valva Pulmonar , Função Ventricular Direita , Pressão Ventricular , Humanos , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Idoso , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Adulto , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Artéria Pulmonar/fisiopatologia , Artéria Pulmonar/diagnóstico por imagem , Curva ROC , Área Sob a Curva , Pressão Arterial , Índice de Gravidade de Doença
12.
Heart Vessels ; 39(6): 556-562, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38368576

RESUMO

Cardiac magnetic resonance imaging (CMR) often shows discrepancies between right ventricular outflow tract (RVOT) flow and left ventricular outflow tract flow in patients with late-stage repaired tetralogy of Fallot (rTOF), leading to potential errors in pulmonary regurgitation fraction (PRF) assessment. This study aimed to identify the conditions under which RVOT flow can be acutely evaluated using four-dimensional (4D) flow CMR. Twenty-seven consecutive patients with rTOF underwent both two-dimensional phase-contrast (2D PC) and 4D flow CMR between 2016 and 2018, excluding those with peripheral pulmonary artery stenosis, RVOT conduit replacement, unknown surgical method, and an aortic valve regurgitation greater than 20%. Seven healthy controls also underwent only 4D Flow CMR. All healthy controls and fifteen patients with rTOF showed laminar RVOT flow, while seven patients exhibited helical, and four patients exhibited vortical RVOT flow in 4D flow CMR visualization. Flow-volume concordance between the pulmonary artery and aortic flow was significantly lower in patients with rTOF and PRF > 40% in 2D PC CMR. This concordance rate in the suprapulmonary valve was high in both the TOF and control groups, comparing at five RVOT locations in 4D flow CMR. Regarding RVOT flow regurgitation in 4D flow, the whole bulk evaluation exhibited greater variation depending on the flow type compared to the whole pixel-wise evaluation. The study confirmed the flow volume at the upper section of the pulmonary valve as the most accurate correlate of aortic flow volume. Furthermore, the 4D flow CMR using the pixel-wise method demonstrated superior accuracy compared to the traditional bulk flow method.


Assuntos
Imagem Cinética por Ressonância Magnética , Tetralogia de Fallot , Humanos , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/fisiopatologia , Masculino , Feminino , Adulto , Imagem Cinética por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Adolescente , Procedimentos Cirúrgicos Cardíacos/métodos , Adulto Jovem , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Direita/fisiologia , Estudos Retrospectivos , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/diagnóstico , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Criança , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem
13.
Catheter Cardiovasc Interv ; 103(4): 587-596, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38341624

RESUMO

BACKGROUND: Pulsta valve is increasingly used for percutaneous pulmonary valve implantation (PPVI) in patients with a large native right ventricular outflow tract (RVOT). This study aims to elucidate the outcomes of Pulsta valve implantation within the native RVOT and assess its adaptability to various native main pulmonary artery (PA) anatomies. METHODS: A multicenter retrospective study included 182 patients with moderate to severe pulmonary regurgitation in the native RVOT who underwent PPVI with Pulsta valves® between February 2016 and August 2023 at five Korean and Taiwanese tertiary referral centers. RESULTS: Pulsta valve implantation was successful in 179 out of 182 patients (98.4%) with an average age of 26.7 ± 11.0 years. The median follow-up duration was 29 months. Baseline assessments revealed enlarged right ventricle (RV) volume (mean indexed RV end-diastolic volume: 163.1 (interquartile range, IQR: 152.0-180.3 mL/m²), which significantly decreased to 123.6(IQR: 106.6-137.5 mL/m2  after 1 year. The main PA types were classified as pyramidal (3.8%), straight (38.5%), reverse pyramidal (13.2%), convex (26.4%), and concave (18.1%) shapes. Pulsta valve placement was adapted, with distal main PA for pyramidal shapes and proximal or mid-PA for reverse pyramidal shapes. Two patients experienced Pulsta valve embolization to RV, requiring surgical removal, and one patient encountered valve migration to the distal main PA, necessitating surgical fixation. CONCLUSIONS: Customized valve insertion sites are pivotal in self-expandable PPVI considering diverse native RVOT shape. The rather soft and compact structure of the Pulsta valve has characteristics to are adaptable to diverse native RVOT geometries.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Adolescente , Adulto Jovem , Adulto , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Ventrículos do Coração , Estudos Retrospectivos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Resultado do Tratamento , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Cateterismo Cardíaco
14.
Int J Cardiovasc Imaging ; 40(3): 655-664, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38363435

RESUMO

In patients with repaired tetralogy of Fallot (rTOF), the regurgitant fraction (RF) in left pulmonary artery (LPA) and right pulmonary artery (RPA) is usually unequal. The morphometrics may play a crucial role in this RF discrepancy. Cardiovascular MR of 79 rTOF patients and 20 healthy controls were retrospectively enrolled. Forty-four from the 79 patients were matched in age, sex and body surface area to the 20 controls and were investigated for: (1) phase-contrast flow of main pulmonary artery (MPA), LPA, and RPA; (2) vascular angles: the angles between the thoracic anterior-posterior line (TAPL) with MPA (θM-AP), MPA with RPA (θM-R), and MPA with LPA (θM-L); (3) cardiac angle, the angle between TAPL and the interventricular septum; (4) area ratio of bilateral lung and hemithorax regions. Compared with the 20 controls, the 44 rTOF patients exhibited wider θM-AP, sharper θM-L angle, and a smaller θM-L/θM-R ratio. In the 79 rTOF patients, LPA showed lower forward, backward, and net flow, and greater RF as compared with RPA. Multivariate analysis showed that the RF of LPA was negatively associated with the θM-L/θM-R ratio and the age at surgery (R2 = 0.255). Conversely, the RF of RPA was negatively associated with the left lung/left hemithorax area ratio and cross-sectional area (CSA) of LPA, and positively associated with CSA of RPA and MPA (R2 = 0.366). In rTOF patients, the RF of LPA is more severe than that of RPA, which may be related to the vascular morphometrics. Different morphometric parameters are independently associated with the RF of LPA or RPA, which may offer potential insights for surgical strategies.


Assuntos
Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Septo Interventricular , Humanos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Estudos Retrospectivos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Valor Preditivo dos Testes
15.
Catheter Cardiovasc Interv ; 103(4): 612-617, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38419395

RESUMO

While newer self-expanding pulmonic valves were primarily designed for larger right ventricular outflow tracks, there are instances where even larger anatomies cannot accommodate these devices. In this report, we describe the successful implantation of two Harmony™ valves in bilateral branch pulmonary arteries after exhausting other options.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar , Humanos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Artéria Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco
16.
Echocardiography ; 41(2): e15765, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38341768

RESUMO

BACKGROUND: Mixed pulmonary disease with pulmonary regurgitation (PR) and stenosis (PS) in repaired tetralogy of Fallot (rTOF) can negatively impact ventricular health. Myocardial strain has been shown to be more sensitive at detecting occult ventricular dysfunction compared to right ventricular ejection fraction (RV EF). We hypothesize that rTOF patients with predominant PS will have lower RV global longitudinal strain (RV GLS) prior to and post-transcatheter pulmonary valve replacement (TPVR). METHODS: A retrospective cohort of rTOF patients who underwent cardiac magnetic resonance (CMR) and cardiac catheterization for right ventricular pressure (RVSP) measurement were analyzed at three time points: before valve implantation, at discharge and within 18 months post-TPVR. Patients were dichotomized into three groups based on RVSP: 0%-49%, 50%-74%, and >75%. RV GLS and left ventricular (LV) GLS by speckle tracking echocardiography (STE) were obtained from the apical 4-chamber using TomTec software (TOMTEC IS, Germany). RESULTS: Forty-eight patients were included. Every 14.3% increase in preimplantation RVSP above 28% was associated with an absolute magnitude 1% lower RV GLS (p = .001). Preimplantation RVSP when 75% or higher had 3.36% worse RV GLS than the lowest bin (p = .014). Overall, average RV strain magnitude was higher when preimplantation RVSP was less than 50% and had greater improvement over the three time points. Higher post implantation RVSP correlated with lower strain magnitude. CONCLUSION: Patients with significant PS (>50%) may benefit from earlier PVR and not depend solely on RV size and EF. Myocardial strain may be a more sensitive marker of function; however, larger, prospective studies are needed.


Assuntos
Insuficiência da Valva Pulmonar , Estenose da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Disfunção Ventricular Direita , Humanos , Tetralogia de Fallot/complicações , Tetralogia de Fallot/cirurgia , Deformação Longitudinal Global , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Volume Sistólico , Estudos Retrospectivos , Função Ventricular Direita , Estenose da Valva Pulmonar/complicações , Estenose da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/complicações , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/cirurgia , Disfunção Ventricular Direita/complicações , Disfunção Ventricular Direita/diagnóstico por imagem
17.
J Cardiovasc Magn Reson ; 26(1): 100002, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38211659

RESUMO

BACKGROUND: Many patients with repaired tetralogy of Fallot require pulmonary valve replacement (PVR) due to significant pulmonary regurgitation (PR). Transcatheter PVR (TPVR) is an equally effective and less invasive alternative to surgical PVR but many native right ventricular outflow tracts (RVOTs) are too large for TPVR at time of referral. Understanding the rate of growth of the RVOT may help optimize timing of referral. This study aims to examine the longitudinal growth of the native RVOT over time in repaired tetralogy of Fallot (TOF). METHODS: A retrospective review of serial cardiac MRI cardiovascular magnetic resonance (CMR) data from 121 patients with repaired TOF and a native RVOT (median age at first CMR 14.7 years, average interval between the first and last CMR of 8.1 years) was performed to measure serial changes in RVOT diameter, cross-sectional area, perimeter-derived diameter, and length. RESULTS: All parameters of RVOT size continued to grow with increasing age but growth was more rapid in the decade after TOF repair (for minimum systolic diameter, mean increase of 5.7 mm per 10 years up to year 12, subsequently 2.3 mm per 10 years). The RVOT was larger with a transannular patch and in patients without pulmonary stenosis (p < 0.001 for both), but this was not associated with rate of growth. More rapid RVOT enlargement was noted in patients with larger right ventricular end-diastolic volume (RVEDV), higher PR fraction, and greater rates of increases in RVEDV and PR (p < 0.001 for all) CONCLUSIONS: in patients with repaired TOF, using serial CMR data, we found that RVOT size increased progressively at all ages, but the rate was more rapid in the first decade after repair. More rapid RVOT enlargement was noted in patients with a larger RV, more PR, and greater rates of increases in RV size and PR severity. These results may be important in considering timing of referral for transcatheter pulmonary valves, in planning transcatheter and surgical valve replacement, and in designing future valves for the native RVOT.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Valor Preditivo dos Testes , Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Função Ventricular Direita , Humanos , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/fisiopatologia , Estudos Retrospectivos , Adolescente , Fatores de Tempo , Criança , Adulto Jovem , Masculino , Feminino , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Resultado do Tratamento , Adulto , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Estudos Longitudinais , Pré-Escolar , Imagem Cinética por Ressonância Magnética , Fatores Etários , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Valva Pulmonar/fisiopatologia , Lactente , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade
18.
Catheter Cardiovasc Interv ; 103(3): 455-463, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38204358

RESUMO

This manuscript describes the feasibility and approach to the assessment and performance of transcatheter pulmonary valve replacement (tPVR) in patients with surgically-created "double-barrel" right ventricular outflow tracts (RVOT). Patients with tetralogy of Fallot may have coronary anomalies which prohibit the performance of traditional tetralogy of Fallot repair. In certain cases, this may necessitate the placement of a right ventricle to pulmonary artery conduit in addition to the native RVOT, which is left in situ, creating so-called "double-barrel" RVOTs. When these patients develop RVOT dysfunction later in life, they would typically be referred for reoperation due to concerns for risk of coronary compression associated with a transcatheter approach. However, whether a transcatheter approach with valve replacement in the native RVOT is feasible or safe is unknown. This was a retrospective review of patients with a surgically created "double-barrel" RVOTs who underwent cardiac catheterization for assessment of tPVR at Boston Children's Hospital. From July 2012 to July 2022, there were four patients with "double-barrel" RVOTs who underwent assessment for tPVR. The age at catheterization ranged between 22 and 39 years. In three out of four patients, coronary compression testing was negative. These three patients had successful tPVR in the native RVOT. At follow up, all three patients were free of greater than mild regurgitation by echocardiogram and had a maximum instantaneous gradient across the RVOT ranging between 20 and 33 mmHg. Performance of tPVR in patients with surgically created "double-barrel" RVOTs is feasible. The safety of this procedure depends crucially on coronary artery assessment at all stages.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Criança , Humanos , Adulto Jovem , Adulto , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Ventrículos do Coração/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Estudos Retrospectivos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia
19.
BMC Cardiovasc Disord ; 24(1): 15, 2024 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172687

RESUMO

BACKGROUND: Patients with repaired Tetralogy of Fallot (rTOF) often develop pulmonary regurgitation (PR) and right ventricle (RV) dysfunction, experiencing increased mortality and morbidity rates in adulthood. Pulmonary valve replacement (PVR) timing to address PR is controversial. Cardiac Magnetic Resonance (CMR) is the gold standard for morpho-functional evaluation of complex cardiopathies. This study aims to identify CMR parameters predictive of adverse outcomes to help defining the best therapeutic management of rTOF patients. METHODS: 130 rTOF patients who underwent CMR (2006-2019) were enrolled in this retrospective single-center study. CMR, clinical, ECG and exercise data were analyzed. Univariate and multivariate analyses identified clinical and CMR parameters predictive of adverse outcomes both individually (e.g., death, arrhythmias, heart failure (HF), pharmacological therapy, QRS ≥ 160ms) and as composite outcome. RESULTS: Univariate analysis confirmed RV volumes and RV ejection fraction corrected for PR as adverse outcome predictors and identified interesting correlations: pulmonary artery bifurcation geometry and abnormal interventricular septum (IVS) motion with arrhythmias (p < .001; p = .037), HF (p = .049; p = .005), composite outcome (p = .039; p = .009); right atrium (RA) dimensions with the composite outcome and the outcomes individually (p < .001). The best predictive models by multivariate analysis included sex (male), RV and RA dilation for QRS ≥ 160ms, time form repair to CMR, age at TOF repair and IVS fibrosis for pharmacological therapy. CONCLUSIONS: Besides RV volumes, new adverse prognostic factors could guide rTOF therapeutic management: pulmonary arteries morphology, abnormal IVS motion, RV dysfunction, RA dilation. Perspective multicentric evaluation is needed to specify their effective role.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Disfunção Ventricular Direita , Humanos , Masculino , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Estudos Retrospectivos , Imageamento por Ressonância Magnética , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Espectroscopia de Ressonância Magnética , Função Ventricular Direita , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia
20.
Catheter Cardiovasc Interv ; 103(2): 359-366, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38054354

RESUMO

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) with the self-expandable Venus P-valve system is a promising treatment for patients with pulmonary regurgitation (PR) and a native right ventricular outflow tract (RVOT). However, limited data is available regarding its midterm outcomes. This study assessed the midterm clinical and echocardiographic outcomes following Venus P-valve implantation. METHODS: From 2013 to 2018, 55 patients with moderate or severe PR after surgical RVOT repair with a transannular or RVOT patch were consecutively enrolled from six hospitals in China. Five-year clinical and echocardiographic outcomes were collected and evaluated. The primary endpoint was a freedom from all-cause mortality and reintervention. RESULTS: At 5 years, the primary endpoint was met for 96% of patients, corresponding to a freedom from all-cause mortality of 96% (95% confidence interval [CI]: 86%-99%) and freedom from reintervention of 98% (95% CI: 87%-100%). Endocarditis was reported in five patients (four patients within 1 year and one patient at 5 years) following PPVI. Transpulmonary gradient and stent orifice diameter remained stable compared to at discharge (p>0.05). No paravalvular leak was reported while only 1 patient gradually increased to moderate PR during follow-up. Significant improvement of RV diameter and LVEF (p<0.001) sustained over the 5-year follow-up, in consistent with remarked improved New York Heart Association(NYHA) functional class (p<0.001). CONCLUSION: The 5-year results of the China VenusP Study demonstrated the midterm benefits of Venus P-valve implantation in the management of patients with severe PR with an enlarged native RVOT by providing sustained symptomatic and hemodynamic improvement.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Obstrução do Fluxo Ventricular Externo , Humanos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Seguimentos , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Desenho de Prótese , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...