Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.134
Filtrar
1.
BMC Musculoskelet Disord ; 25(1): 650, 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39160506

RESUMO

PURPOSE: Implanted devices used in metastatic spine tumor surgery (MSTS) include pedicle screws, fixation plates, fixation rods, and interbody devices. A material to be used to fabricate any of these devices should possess an array of properties, which include biocompatibility, no toxicity, bioactivity, low wear rate, low to moderate incidence of artifacts during imaging, tensile strength and modulus that are comparable to those of cortical bone, high fatigue strength/long fatigue life, minimal or no negative impact on radiotherapy (RT) planning and delivery, and high capability for fusion to the contiguous bone. The shortcomings of Ti6Al4V alloy for these applications with respect to these desirable properties are well recognized, opening the field for an investigation about novel biomaterials that could replace the current gold standard. Previously published reviews on this topic have exhibited significant shortcomings in the studies they included, such as a small, heterogenous sample size and the lack of a cost-benefit analysis, extremely useful to understand the practical possibility of applying a novel material on a large scale. Therefore, this review aims to collect information about the clinical performance of these biomaterials from the most recent literature, with the objective of deliberating which could potentially be better than titanium in the future, with particular attention to safety, artifact production and radiotherapy planning interference. The significant promise showed by analyzing the clinical performance of these devices warrants further research through prospective studies with a larger sample size also taking into account each aspect of the production and use of such materials. METHODS: The Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines were used to improve the reporting of the review. The search was performed from March 2022 to September 2023. RESULTS: At the end of the screening process, 20 articles were considered eligible for this study. Polyetheretherketone (PEEK), Carbon-fibre reinforced polyetheretherketone (CFR-PEEK), long carbon fiber reinforced polymer (LCFRP), Polymethylmethacrylate (PMMA), and carbon screw and rods were used in the included studies. CONCLUSION: CFR-PEEK displays a noninferior safety and efficacy profile to titanium implanted devices. However, it also has other advantages. By decreasing artifact production, it is able to increase detection of local tumor recurrence and decrease radiotherapy dose perturbation, ultimately bettering prognosis for patients necessitating adjuvant treatment. Nonetheless, its drawbacks have not been explored fully and still require further investigation in future studies. This does not exclude the fact that CFR-PEEK could be a valid alternative to titanium in the near future.


Assuntos
Neoplasias da Coluna Vertebral , Titânio , Humanos , Neoplasias da Coluna Vertebral/cirurgia , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/secundário , Ligas , Materiais Biocompatíveis , Polímeros , Resultado do Tratamento , Cetonas , Benzofenonas , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Parafusos Pediculares
2.
Sci Rep ; 14(1): 18946, 2024 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-39147799

RESUMO

This study used the dip-coating method to develop a new biocompatible coating composed of polylactide (PLA) and casein for ZnMg1.2 wt% alloy implants. It evaluated its impact on the alloy's degradation in a simulated body fluid. After 168 h of immersion in Ringer's solution, surface morphology analysis showed that the PLA-casein coatings demonstrated uniform degradation, with the corrosion current density measured at 48 µA/cm2. Contact angle measurements indicated that the average contact angles for the PLA-casein-coated samples were below 80°, signifying a hydrophilic nature that promotes cell adhesion. Fourier-transform infrared spectroscopy (FTIR) revealed no presence of lactic acid on PLA-casein coatings after immersion, in contrast to pure PLA coatings. Pull-off adhesion tests showed tensile strength values of 7.6 MPa for pure PLA coatings and 5 MPa for PLA-casein coatings. Electrochemical tests further supported the favorable corrosion resistance of the PLA-casein coatings, highlighting their potential to reduce tissue inflammation and improve the biocompatibility of ZnMg1.2 wt% alloy implants.


Assuntos
Ligas , Caseínas , Materiais Revestidos Biocompatíveis , Poliésteres , Ligas/química , Caseínas/química , Materiais Revestidos Biocompatíveis/química , Poliésteres/química , Corrosão , Teste de Materiais , Propriedades de Superfície , Espectroscopia de Infravermelho com Transformada de Fourier , Resistência à Tração
3.
PLoS One ; 19(8): e0300270, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39106270

RESUMO

Total hip arthroplasty (THA) is one of the most successful orthopaedic interventions globally, with over 450,000 procedures annually in the U.S. alone. However, issues like aseptic loosening, dislocation, infection and stress shielding persist, necessitating complex, costly revision surgeries. This highlights the need for continued biomaterials innovation to enhance primary implant integrity and longevity. Implant materials play a pivotal role in determining long-term outcomes, with titanium alloys being the prominent choice. However, emerging evidence indicates scope for optimized materials. The nickel-free ß titanium alloy Ti-27Nb shows promise with excellent biocompatibility and mechanical properties. Using finite element analysis (FEA), this study investigated the biomechanical performance and safety factors of a hip bone implant made of nickel-free titanium alloy (Ti-27Nb) under actual loading during routine day life activities for different body weights. The FEA modelled physiological loads during walking, jogging, stair ascent/descent, knee bend, standing up, sitting down and cycling for 75 kg and 100 kg body weights. Comparative analyses were conducted between untreated versus 816-hour simulated body fluid (SBF) treated implant conditions to determine in vivo degradation effects. The FEA predicted elevated von Mises stresses in the implant neck for all activities, especially stair climbing, due to its smaller cross-section. Stresses increased substantially with a higher 100 kg body weight compared to 75 kg, implying risks for heavier patients. Safety factors were reduced by up to 58% between body weights, although remaining above the desired minimum value of 1. Negligible variations were observed between untreated and SBF-treated responses, attributed to Ti-27Nb's excellent biocorrosion resistance. This comprehensive FEA provided clinically relevant insights into the biomechanical behaviour and integrity of the Ti-27Nb hip implant under complex loading scenarios. The results can guide shape and material optimization to improve robustness against repetitive stresses over long-term use. Identifying damage accumulation and failure risks is crucial for hip implants encountering real-world variable conditions. The negligible SBF effects validate Ti-27Nb's resistance to physiological degradation. Overall, the study significantly advances understanding of Ti-27Nb's suitability for reliable, durable hip arthroplasties with low revision rates.


Assuntos
Ligas , Análise de Elementos Finitos , Prótese de Quadril , Estresse Mecânico , Titânio , Prótese de Quadril/efeitos adversos , Humanos , Ligas/química , Artroplastia de Quadril/efeitos adversos , Suporte de Carga , Nióbio/química , Fenômenos Biomecânicos , Teste de Materiais , Desenho de Prótese
4.
BMC Oral Health ; 24(1): 902, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39107737

RESUMO

BACKGROUND: Long-term success of implant restoration depends on many factors one of them is the sufficient implant stability which is lowered in compromised bone density sites such as the maxilla as it is categorized as type III & IV bone, so searching for a new innovation and updates in implant material and features is very mandatory. So, the aim of this study was to compare between two implant materials (roxolid and traditional titanium) on the primary and secondary stability of implant retained maxillary overdenture. METHODS: Eighteen completely edentulous patients were selected. All patients received maxillary implant-retained overdentures and lower complete dentures; patients were divided equally into two groups according to the type of implant materials. Group A received a total number of 36 implants made of roxolid material and Group B received a total number of 36 implants made of traditional titanium alloys. Implant stability was assessed using ostell device, the primary implant stability was measured at the day of implant installation however, secondary implant stability was measured after six weeks of implant placement. Paired t-test was used to compare between primary and secondary stability in the same group and an independent t-test was used to compare between the two groups with a significant level < 0.05. RESULTS: Independent t-test revealed a significant difference between the two groups with p -value = 0.0141 regarding primary stability and p-value < 0.001 regarding secondary stability, as roxolid implant group was statistically higher stability than titanium group in both. Paired t- test showed a statistically significant difference in roxolid implant group with p-value = 0.0122 however, there was non-statistically significant difference in titanium group with p-value = 0.636. Mann Whitney test showed a significant difference between the two groups regarding amount of change in stability with p value = 0.191. roxolid implant group showed a higher amount of change in stability than the titanium implant group. CONCLUSION: Within the limitation of this study, it could be concluded that: Roxolid implants showed promising results regarding primary and secondary stability compared to conventional Titanium implants and can be a better alternative in implant retained maxillary overdentures. TRIAL REGISTRATION: Retrospectively NCT06334770 at 26-3-2024.


Assuntos
Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Maxila , Titânio , Humanos , Masculino , Feminino , Maxila/cirurgia , Pessoa de Meia-Idade , Implantes Dentários , Ligas Dentárias/química , Idoso , Zircônio , Retenção de Dentadura , Materiais Dentários/química , Ligas
5.
Langmuir ; 40(32): 16791-16803, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39086155

RESUMO

Orthopedic and dental implants made from Ti6Al4V are widely used due to their excellent mechanical properties and biocompatibility. However, the long-term performance of these implants can be compromised by bacterial infections. This study explores the development of hierarchically textured surfaces with enhanced bactericidal properties to address such challenges. Hierarchical surface structures were developed by combining microscale features produced by a microsecond laser and superimposed submicron features produced using a femtosecond laser. Microscale patterns were produced by the pulsed laser surface melting process, whereas submicrometer laser-induced periodic surface structures were created on top of them by femtosecond laser processing. Escherichia coli bacterial cells were cultured on the textured surface. After 24 h, a staining analysis was performed using SYTO9 and PI dyes to investigate the samples with a confocal microscope for live dead assays. Results showed bacterial colony formation onto the microscale surface textures with live bacterial cells, whereas the hierarchical surface textures display segregated and physically damaged bacterial cell attachments on surfaces. The hierarchical surface textures showed ∼98% dead bacterial cells due to the combined effect of its multiscale surface features and oxide formation during the laser processing steps. The efficacy of hierarchical surface textures in enhancing the antibacterial behavior of Ti6Al4V implants is evident from the conducted research. Such laser-based surface treatments can find potential applications in different industrial sectors.


Assuntos
Ligas , Antibacterianos , Escherichia coli , Lasers , Propriedades de Superfície , Titânio , Titânio/química , Titânio/farmacologia , Ligas/química , Ligas/farmacologia , Escherichia coli/efeitos dos fármacos , Antibacterianos/farmacologia , Antibacterianos/química
6.
ACS Biomater Sci Eng ; 10(8): 5300-5312, 2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39087496

RESUMO

The development of well-adherent, amorphous, and bioactive glass coatings for metallic implants remains a critical challenge in biomedical engineering. Traditional bioactive glasses are susceptible to crystallization and exhibit a thermal expansion mismatch with implant materials. This study introduces a novel approach to overcome these limitations by employing systematic Na2O substitution with CaO in borosilicate glasses. In-depth structural analysis (MD simulations, Raman spectroscopy, and NMR) reveals a denser network with smaller silicate rings, enhancing thermal stability, reducing thermal expansion, and influencing dissolution kinetics. This tailored composition exhibited optimal bioactivity (in vitro formation of bone-like apatite within 3 days) and a coefficient of thermal expansion closely matching Ti-6Al-4V, a widely used implant material. Furthermore, a consolidation process, meticulously designed with insights from crystallization kinetics and the viscosity-temperature relationship, yielded a crack-free, amorphous coating on Ti-6Al-4V substrates. This novel coating demonstrates excellent cytocompatibility and strong antibacterial action, suggesting superior clinical potential compared with existing technologies.


Assuntos
Materiais Revestidos Biocompatíveis , Vidro , Titânio , Vidro/química , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Titânio/química , Próteses e Implantes , Antibacterianos/química , Antibacterianos/farmacologia , Teste de Materiais , Propriedades de Superfície , Ligas/química , Humanos
7.
Langmuir ; 40(33): 17301-17310, 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39106975

RESUMO

This paper deals with the combined effects of immune response and osseointegration because of the lack of comprehensive studies on this topic. An antibacterial Ti surface was considered because of the high risk of infection for titanium bone implants. A chemically treated Ti6Al4 V alloy [Ti64(Sr-Ag)] with a microporous and Sr-Ag doped surface was compared to a polished version (Ti64) regarding protein adsorption (albumin and fibronectin) and osteoimmunomodulation. Characterization via fluorescence microscopy and zeta potential showed a continuous fibronectin layer on Ti64(Sr-Ag), even with preadsorbed albumin, while it remained filamentous on Ti64. Macrophages (differentiated from THP-1 monocytes) were cultured on both surfaces, with viability and cytokine release analyzed. Differently from Ti64, Ti64(Sr-Ag) promoted early anti-inflammatory responses and significant downregulation of VEGF. Ti64(Sr-Ag) also enhanced human bone marrow mesenchymal cell differentiation toward osteoblasts, when a macrophage-conditioned medium was used, influencing ALP production. Surface properties in relation to protein adsorption and osteoimmunomodulation were discussed.


Assuntos
Ligas , Macrófagos , Propriedades de Superfície , Titânio , Titânio/química , Ligas/química , Ligas/farmacologia , Adsorção , Humanos , Macrófagos/efeitos dos fármacos , Macrófagos/imunologia , Diferenciação Celular/efeitos dos fármacos , Osteoblastos/efeitos dos fármacos , Osteoblastos/citologia
8.
J Orthop Surg Res ; 19(1): 499, 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39175032

RESUMO

BACKGROUND: Unicompartmental knee arthroplasty (UKA) has been proved to be a successful treatment for osteoarthritis patients. However, the stress shielding caused by mismatch in mechanical properties between human bones and artificial implants remains as a challenging issue. This study aimed to properly design a bionic porous tibial implant and evaluate its biomechanical effect in reconstructing stress transfer pathway after UKA surgery. METHODS: Voronoi structures with different strut sizes and porosities were designed and manufactured with Ti6Al4V through additive manufacturing and subjected to quasi-static compression tests. The Gibson-Ashby model was used to relate mechanical properties with design parameters. Subsequently, finite element models were developed for porous UKA, conventional UKA, and native knee to evaluate the biomechanical effect of tibial implant with designed structures during the stance phase. RESULTS: The internal stress distribution on the tibia plateau in the medial compartment of the porous UKA knee was found to closely resemble that of the native knee. Furthermore, the mean stress values in the medial regions of the tibial plateau of the porous UKA knee were at least 44.7% higher than that of the conventional UKA knee for all subjects during the most loading conditions. The strain shielding reduction effect of the porous UKA knee model was significant under the implant and near the load contact sites. For subject 1 to 3, the average percentages of nodes in bone preserving and building region (strain values range from 400 to 3000 µm/m) of the porous UKA knee model, ranging from 68.7 to 80.5%, were higher than that of the conventional UKA knee model, ranging from 61.6 to 68.6%. CONCLUSIONS: The comparison results indicated that the tibial implant with designed Voronoi structure offered better biomechanical functionality on the tibial plateau after UKA. Additionally, the model and associated analysis provide a well-defined design process and dependable selection criteria for design parameters of UKA implants with Voronoi structures.


Assuntos
Artroplastia do Joelho , Análise de Elementos Finitos , Prótese do Joelho , Desenho de Prótese , Estresse Mecânico , Artroplastia do Joelho/métodos , Humanos , Porosidade , Tíbia/cirurgia , Fenômenos Biomecânicos , Titânio , Ligas
9.
J Orthop Surg Res ; 19(1): 501, 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39175072

RESUMO

New technologies in additive manufacturing and patient-specific CT-based custom implant designs make it possible for previously unimaginable salvage and limb-sparing operations a practical reality. This study presents the design and fabrication of a lattice-structured implant for talus replacement surgery. Our primary case involved a young adult patient who had sustained severe damage to the talus, resulting in avascular necrosis and subsequent bone collapse. This condition caused persistent and debilitating pain, leading the medical team to consider amputation of the left foot at the ankle level as a last resort. Instead, we proposed a Ti6Al4V-based patient-specific implant with lattice structure specifically designed for pan-talar fusion. Finite element simulation is conducted to estimate its performance. To ensure its mechanical integrity, uniaxial compression experiments were conducted. The implant was produced using selective laser melting technology, which allowed for precise and accurate construction of the unique lattice structure. The patient underwent regular monitoring for a period of 24 months. At 2-years follow-up the patient successfully returned to activities without complication. The patient's functional status was improved, limb shortening was minimized.


Assuntos
Osteonecrose , Desenho de Prótese , Tálus , Humanos , Tálus/cirurgia , Tálus/lesões , Tálus/diagnóstico por imagem , Osteonecrose/cirurgia , Osteonecrose/etiologia , Osteonecrose/diagnóstico por imagem , Masculino , Adulto , Ligas , Titânio , Próteses e Implantes , Adulto Jovem , Análise de Elementos Finitos , Tomografia Computadorizada por Raios X
10.
Stomatologiia (Mosk) ; 103(4): 10-19, 2024.
Artigo em Russo | MEDLINE | ID: mdl-39171338

RESUMO

THE AIM OF THE STUDY: To develop and implement a comprehensive algorithm for the rehabilitation of patients after partial resection of the mandible using a titanium «growing¼ endoprosthesis. MATERIAL AND METHODS: The study included 16 patients aged 2 to 7 years, with benign (6 cases) and malignant (10 cases) tumors of the mandible. The patients were divided into 2 groups depending on the time of fixation of the endoprosthesis. Group 1 included patients with simultaneous installation of a prosthesis (7 people). Group 2 included patients with delayed installation of an endoprosthesis (9 people). For the reconstruction of the mandible, «growing¼ titanium endoprostheses made of Ti6Al4V alloy of various designs were used. Removable orthodontic devices of mechanical and functional type of action, standard elastic mouthguards were used in the process of dental treatment. RESULTS: A comprehensive algorithm has been developed for the rehabilitation of children after partial resection of the mandible, depending on the time of fixation of the prosthesis and the volume of surgical intervention. CONCLUSION: The developed algorithm of complex rehabilitation using a «growing¼ endoprosthesis and dental support at the pre and postoperative stages allows to reduce the volume of secondary deformation of facial structures and dentition.


Assuntos
Mandíbula , Neoplasias Mandibulares , Titânio , Humanos , Criança , Pré-Escolar , Neoplasias Mandibulares/cirurgia , Masculino , Feminino , Mandíbula/cirurgia , Ligas , Algoritmos , Reconstrução Mandibular/métodos , Reconstrução Mandibular/instrumentação
11.
J Orthop Surg Res ; 19(1): 510, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39192290

RESUMO

BACKGROUND: Cerclage wiring is commonly used for treating fractures; however, it has several limitations, including mechanical weakness, decreased blood circulation, and technical complexity. In this study, we developed an implant using a shape memory alloy (SMA) and tested its efficacy in treating Vancouver type B1 (VB1) periprosthetic femoral fractures (PFFs) in a canine model. METHODS: The mid-diaphyseal fracture models underwent reduction via the SMA plate (SMA group) or the cerclage cable plate (cable group) method in randomly selected pelvic limbs. An intraoperative evaluation was conducted to assess the surgical time and difficulty related to implant fitting. Clinical assessments, radiography, microcomputed tomography (micro-CT), histological analysis, positron emission tomography (PET)/CT, and galvanic corrosion analysis were conducted for 52 weeks to evaluate bone healing and blood perfusion. RESULTS: The results for bone healing and blood perfusion were not significantly different between the groups (p > 0.05). In addition, no evidence of galvanic corrosion was present in any of the implants. However, the median surgical time was 75 min (range, 53-82 min) for the SMA group and 126 min (range, 120-171 min) for the cable group, which was a statistically significant difference (p = 0.0286). CONCLUSIONS: This study assessed the ability of a newly developed shape memory alloy (SMA) to treat VB1 periprosthetic femoral fractures (PFFs) in canines for over a 52-week period and revealed outcomes comparable to those of traditional methods in terms of bone healing and mechanical stability. Despite the lower surgical complexity and potential time-saving benefits of this treatment, further research is needed to confirm its efficacy.


Assuntos
Ligas , Estudos de Viabilidade , Fraturas do Fêmur , Fraturas Periprotéticas , Animais , Cães , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/diagnóstico por imagem , Projetos Piloto , Fraturas Periprotéticas/cirurgia , Modelos Animais de Doenças , Fixação Interna de Fraturas/métodos , Consolidação da Fratura/fisiologia
12.
J Int Med Res ; 52(8): 3000605241274591, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39188138

RESUMO

Renal calyceal neck atresia is a rare disorder. There is no clear guidance for standard treatment of this condition. The Memokath™ 045 temperature-controlled memory alloy stent is commonly used in the treatment of urethral strictures, but it has not been used for treating calyceal neck atresia. We present a case of a 44-year-old female patient with left lumbar pain who underwent two stages of treatment to resolve calyceal neck atresia located at the upper calyx of her left kidney. The first procedure was transurethral ureteroscopy combined with percutaneous recanalization of the left upper calyx calyceal neck atresia. One 6 F internal stent and one 8 F internal stent were placed, and she was discharged with a left nephrostomy tube. After her urinary tract infection was fully resolved, the patient returned for the second procedure of percutaneous upper renal calyx calyceal neck metal stent implantation. The temporary stents and nephrostomy tube were successfully removed. Our findings suggest that the Memokath™ 045 temperature-controlled memory alloy stent is an effective choice for treating calyceal neck atresia.


Assuntos
Ligas , Cálices Renais , Stents , Humanos , Feminino , Adulto , Cálices Renais/cirurgia , Cálices Renais/anormalidades , Temperatura , Resultado do Tratamento
13.
PLoS One ; 19(8): e0306604, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39190664

RESUMO

This study aims to solve the problem of springback control of aluminum alloy components in the rolling process, and the method of combining experiment and simulation is adopted. Firstly, a series of aluminum alloy samples are designed, and the four-axis flexible bending machine is used for precision roll bending. Secondly, the three-dimensional (3D) shape change data of the workpiece before and after roll bending is monitored and recorded in real-time by a high-precision 3D scanner. Meanwhile, aiming at different rolling process parameters of each group (including roll bend speed, feed rate, pre-deformation amount, mold curvature radius, and other factors), advanced finite element software is used to carry out detailed simulation and calculations. In addition, the coincidence is compared and analyzed between the actual experiment results and the simulation prediction. The stress-strain distribution and springback evolution of aluminum alloy during roll bending are described accurately. The experimental and simulation results show that the springback rate of aluminum alloy fluctuates in the range of 5% to 15% after four-axis flexible roll bending, and the specific springback value is influenced by various process parameters. For example, under the premise of keeping other conditions unchanged, when the roll bending speed is increased from 30mm/s to 60mm/s, the springback rate shows an upward trend of about 3%. By increasing the feed rate by 20%, an average decrease of about 7% in springback quantity is observed. It can be seen that the increase in roll bending speed can aggravate the springback phenomenon, and the appropriate increase in feed rate can play a certain role in restraining the springback. Further analysis shows that the choice of the mold curvature radius and pre-deformation amount also has a decisive influence on the springback characteristics. There is a nonlinear relationship between the two parameters and the amount of springback. Changing these two parameters in a specific range can effectively regulate the springback effect.


Assuntos
Ligas , Alumínio , Alumínio/química , Ligas/química , Teste de Materiais , Estresse Mecânico , Análise de Elementos Finitos , Simulação por Computador
14.
J Mech Behav Biomed Mater ; 158: 106681, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39151255

RESUMO

Multifunctional materials have been described to meet the diverse requirements of implant materials for femoral components of uncemented total knee replacements. These materials aim to combine the high wear and corrosion resistance of oxide ceramics at the joint surfaces with the osteogenic potential of titanium alloys at the bone-implant interface. Our objective was to evaluate the biomechanical performance of hybrid material-based femoral components regarding mechanical stress within the implant during cementless implantation and stress shielding (evaluated by strain energy density) of the periprosthetic bone during two-legged squat motion using finite element modeling. The hybrid materials consisted of alumina-toughened zirconia (ATZ) ceramic joined with additively manufactured Ti-6Al-4V or Ti-35Nb-6Ta alloys. The titanium component was modeled with or without an open porous surface structure. Monolithic femoral components of ATZ ceramic or Co-28Cr-6Mo alloy were used as reference. The elasticity of the open porous surface structure was determined within experimental compression tests and was significantly higher for Ti-35Nb-6Ta compared to Ti-6Al-4V (5.2 ± 0.2 GPa vs. 8.8 ± 0.8 GPa, p < 0.001). During implantation, the maximum stress within the ATZ femoral component decreased from 1568.9 MPa (monolithic ATZ) to 367.6 MPa (Ti-6Al-4V/ATZ), 560.9 MPa (Ti-6Al-4V/ATZ with an open porous surface), 474.9 MPa (Ti-35Nb-6Ta/ATZ), and 648.4 MPa (Ti-35Nb-6Ta/ATZ with an open porous surface). The strain energy density increased at higher flexion angles for all models during the squat movement. At ∼90° knee flexion, the strain energy density in the anterior region of the distal femur increased by 25.7 % (Ti-6Al-4V/ATZ), 70.3 % (Ti-6Al-4V/ATZ with an open porous surface), 43.7 % (Ti-35Nb-6Ta/ATZ), and 82.5% (Ti-35Nb-6Ta/ATZ with an open porous surface) compared to monolithic ATZ. Thus, the hybrid material-based femoral component decreases the intraoperative fracture risk of the ATZ part and considerably reduces the risk of stress shielding of the periprosthetic bone.


Assuntos
Artroplastia do Joelho , Fêmur , Análise de Elementos Finitos , Teste de Materiais , Fêmur/cirurgia , Fenômenos Biomecânicos , Estresse Mecânico , Fenômenos Mecânicos , Porosidade , Titânio/química , Ligas/química , Zircônio/química
15.
Int J Biol Macromol ; 277(Pt 2): 134349, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39094857

RESUMO

This study evaluated the effect of solvent acids on the structure and corrosion resistance performance of chitosan (CS) film on MAO-treated AZ31B magnesium (Mg) alloy. Initially, CS solutions were prepared in four solvent acids: acetic acid (HAc), lactic acid (LA), hydrochloric acid (HCl), and citric acid (CA). The CS films were subsequently deposited on MAO-treated AZ31B Mg alloy via a dip-coating technique. Scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction analysis (XRD), Fourier-transform infrared spectroscopy (FT-IR), contact angle measurement, and atomic force microscopy (AFM) were employed to characterize the surface and cross-sectional morphology as well as chemical composition. Furthermore, the samples were subjected to potentiodynamic polarization (PDP) and electrochemical impedance spectroscopy (EIS) tests to assess their resistance against corrosion in simulated body fluid (SBF). These results indicated that the CS film prepared with LA exhibited the lowest surface roughness (Ra = 31.2 nm), the largest contact angle (CA = 98.50°), and the thickest coating (36 µm). Additionally, it demonstrated superior corrosion protection performance, with the lowest corrosion current density (Icorr = 3.343 × 10-7 A/cm2), highest corrosion potential (Ecorr = -1.49 V), and highest polarization resistance (Rp = 5.914 × 104 Ω·cm2) in SBF. These results indicated that solvent acid types significantly influenced their interactions with CS. Thus, the structure and corrosion protection performance of CS films can be optimized by selecting an appropriate solvent acid.


Assuntos
Ligas , Quitosana , Solventes , Quitosana/química , Corrosão , Ligas/química , Solventes/química , Magnésio/química , Espectroscopia de Infravermelho com Transformada de Fourier , Ácidos/química , Propriedades de Superfície , Difração de Raios X
16.
J Gastrointest Cancer ; 55(3): 1425-1432, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39136894

RESUMO

INTRODUCTION: Palliation of malign biliary obstruction is important which is commonly carried out by percutaneous biliary stenting. Our primary aim with this study was assessment of performance of wall stents, and nitinol stents for the palliation of malign biliary obstruction. METHODS: The medical records of 157 patients who underwent biliary stenting in our department between January 1, 1995, and December 31, 2005, were retrospectively analyzed. Technical success, treatment success, mortality in the first 30 days, minor, and major complications were evaluated and compared among the wall stent, and the nitinol stent groups in all patients which constituted the primary study endpoints. Additionally, stent patency, and mean patient survival times after stent implantation were evaluated in patients for whom follow-up information could be obtained. RESULTS: A total of 213 metallic stents were placed in 157 patients. Wall stent was placed in 83 of the patients with mean age, and SD of 60.4 and 13.5. Nitinol stent was placed in 74 of the patients with mean age of 57.8, and SD of 15.5. Gender ratio was equal in both groups. Biliary stent dysfunction was observed in 13 patients in each of nitinol, and wall stent groups throughout the study period. There was no statistical difference among re-occlusion rates (p = 0.91). For the nitinol stent group median primary patency time was 119 days (90-185 days CI 95%), and for the wall stent group median primary patency time was 81 days (60-150 days CI 95%). CONCLUSION: Nitinol stents, and wall stents are safe options that can be safely used in the percutaneous treatment of malignant biliary obstruction with similar treatment and therapeutic success, low complication rates, and patency times that can extend beyond expected survival times.


Assuntos
Ligas , Colestase , Stents , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Colestase/etiologia , Colestase/terapia , Colestase/cirurgia , Estudos Retrospectivos , Stents/efeitos adversos , Idoso , Cuidados Paliativos/métodos , Resultado do Tratamento , Neoplasias dos Ductos Biliares/complicações
17.
J Mater Sci Mater Med ; 35(1): 52, 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39177838

RESUMO

Because nickel-titanium (NiTi) alloys have unique functions, such as superelasticity, shape memory, and hysteresis similar to bone in the loading-unloading cycles of their recoverable deformations. They likely offer good bone integration, a low loosening rate, individual customization, and ease of insertion. Due to the poor processability of NITI, traditional methods cannot manufacture NiTi products with complex shapes. Orthopedic NiTi implants need to show an adequate fracture elongation of at least 8%. Additive manufacturing can be used to prepare NiTi implants with complex structures and tunable porosity. However, as previously reported, additively manufactured NiTi alloys could only exhibit a maximum tensile fracture strain of 7%. In new reports, a selective laser melting (SLM)-NiTi alloy has shown greater tensile strain (15.6%). Nevertheless, due to the unique microstructure of additive manufacturing NiTi that differs from traditional NITI, the biocompatibility of SLM-NITI manufactured by this new process requires further evaluation In this study, the effects of the improved NiTi alloy on bone marrow mesenchymal stem cell (BMSC) proliferation, adhesion, and cell viability were investigated via in vitro studies. A commercial Ti-6Al-4V alloy was studied side-by-side for comparison. Like the Ti-6Al-4V alloy, the SLM-NiTi alloy exhibited low cytotoxicity toward BMSCs and similar effect on cell adhesion or cell viability. This study demonstrates that the new SLM-NiTi alloy, which has exhibited improved mechanical properties, also displays excellent biocompatibility. Therefore, this alloy may be a superior implant material in biomedical implantation.


Assuntos
Ligas , Materiais Biocompatíveis , Adesão Celular , Proliferação de Células , Sobrevivência Celular , Teste de Materiais , Células-Tronco Mesenquimais , Níquel , Resistência à Tração , Titânio , Titânio/química , Materiais Biocompatíveis/química , Ligas/química , Células-Tronco Mesenquimais/efeitos dos fármacos , Células-Tronco Mesenquimais/citologia , Níquel/química , Sobrevivência Celular/efeitos dos fármacos , Adesão Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Animais , Lasers , Próteses e Implantes , Estresse Mecânico , Propriedades de Superfície
18.
J Nanobiotechnology ; 22(1): 422, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39014416

RESUMO

Vascularization plays a significant role in promoting the expedited process of bone regeneration while also enhancing the stability and viability of artificial bone implants. Although titanium alloy scaffolds were designed to mimic the porous structure of human bone tissues to facilitate vascularization in bone repair, their biological inertness restricted their broader utilization. The unique attribute of Metal-organic framework (MOF) MIL-53(Fe), known as "breathing", can facilitate the efficient adsorption of extracellular matrix proteins and thus provide the possibility for efficient interaction between scaffolds and cell adhesion molecules, which helps improve the bioactivity of the titanium alloy scaffolds. In this study, MIL-53(Fe) was synthesized in situ on the scaffold after hydrothermal treatment. The MIL-53(Fe) endowed the scaffold with superior protein absorption ability and preferable biocompatibility. The scaffolds have been shown to possess favorable osteogenesis and angiogenesis inducibility. It was indicated that MIL-53(Fe) modulated the mechanotransduction process of endothelial cells and induced increased cell stiffness by promoting the adsorption of adhesion-mediating extracellular matrix proteins to the scaffold, such as laminin, fibronectin, and perlecan et al., which contributed to the activation of the endothelial tip cell phenotype at sprouting angiogenesis. Therefore, this study effectively leveraged the intrinsic "breathing" properties of MIL-53 (Fe) to enhance the interaction between titanium alloy scaffolds and vascular endothelial cells, thereby facilitating the vascularization inducibility of the scaffold, particularly during the sprouting angiogenesis phase. This study indicates that MIL-53(Fe) coating represents a promising strategy to facilitate accelerated and sufficient vascularization and uncovers the scaffold-vessel interaction from a biomechanical perspective.


Assuntos
Neovascularização Fisiológica , Alicerces Teciduais , Titânio , Titânio/química , Humanos , Alicerces Teciduais/química , Neovascularização Fisiológica/efeitos dos fármacos , Células Endoteliais/efeitos dos fármacos , Estruturas Metalorgânicas/química , Estruturas Metalorgânicas/farmacologia , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Osteogênese/efeitos dos fármacos , Ligas/química , Células Endoteliais da Veia Umbilical Humana , Próteses e Implantes , Mecanotransdução Celular , Adesão Celular/efeitos dos fármacos , Engenharia Tecidual/métodos
19.
Langmuir ; 40(28): 14674-14684, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-38958429

RESUMO

Magnesium-based biodegradable metal bone implants exhibit superior mechanical properties compared to biodegradable polymers for orthopedic and cardiovascular stents. In this study, MgZZC-x (x = 1, 1.2) alloys were screened by in vitro biocompatibility tests in three simulated body fluids under nontoxic conditions. The MgZZC-1 alloys with better biocompatibility were selected to predict the days required for complete degradation. The evolution of degradation products was analyzed, and the mechanism of formation of the product film was inferred. A degradation kinetic model was established to investigate the effect of MEM components on the degradation of the alloys. The results demonstrate that the proteins in MEM can greatly retard the degradation progress by attaching to the surface of MgZZC-1 alloys, which are predicted to degrade completely within 341 days. The carbonate and phosphate buffers were adjusted to pH in MEM solution, delaying the degradation of magnesium alloys. This process in MEM more accurately reflects the actual degradation in the body and is superior to that in Hanks and SBF solutions. This study will promote the application of biodegradable materials in clinical medicine.


Assuntos
Ligas , Materiais Biocompatíveis , Líquidos Corporais , Magnésio , Ligas/química , Líquidos Corporais/química , Magnésio/química , Materiais Biocompatíveis/química , Concentração de Íons de Hidrogênio , Cinética , Humanos
20.
Anal Chim Acta ; 1317: 342919, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39030015

RESUMO

The coronavirus disease 2019 (COVID-19) caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has resulted in widespread disease transmission, challenging the stability of global healthcare systems. Surface-enhanced Raman scattering (SERS) as an easy operation, fast, and low-cost technology illustrates a good potential in detecting SARS-CoV-2. In the study, one-step fabrication of gold-silver alloy nanoparticles (AuAgNPs) with adjustable metal proportions and diameters is employed as SERS substrates. The angiotensin-converting enzyme 2 (ACE2) functionalized AuAgNPs are applied as sensor surfaces to detect SARS-CoV-2 S protein. By optimizing the SERS substrates, ACE2/Au35Ag65NPs illustrate higher performance in detecting the SARS-CoV-2 S protein with a limit of detection (LOD) of 10 fg/mL in both phosphate-buffered saline (PBS) and pharyngeal swabs solution (PSS). It also provides excellent reproducibility with a relative standard deviation (RSD) of 7.7 % and 7.9 %, respectively. This easily preparable and highly reproducible SERS substrate has good potential in the practical application of detecting SARS-CoV-2.


Assuntos
Enzima de Conversão de Angiotensina 2 , COVID-19 , Ouro , Limite de Detecção , Nanopartículas Metálicas , SARS-CoV-2 , Prata , Análise Espectral Raman , Glicoproteína da Espícula de Coronavírus , Análise Espectral Raman/métodos , Prata/química , Glicoproteína da Espícula de Coronavírus/análise , Nanopartículas Metálicas/química , SARS-CoV-2/isolamento & purificação , Humanos , Ouro/química , COVID-19/diagnóstico , COVID-19/virologia , Enzima de Conversão de Angiotensina 2/metabolismo , Enzima de Conversão de Angiotensina 2/química , Ligas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...