Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.167
Filtrar
1.
Sci Rep ; 14(1): 16126, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38997313

RESUMO

Microbubble contrast agents in ultrasound/echocardiography are used to increase the echogenicity of the target tissues, thereby raising the contrast resolution of the resultant image. Recently, the trend has shifted toward the development of phase-convertible nanodroplets as ultrasound contrast agents due to their promising theragnostic potential by switching capability at the active site. Herein, we fabricated pre-PGS- perfluoropentane phase convertible nanodroplets and checked their in vitro and in vivo enhancement and safety profile. For this, we performed experiments on 20 male Wistar rats and 2 dogs. Biochemical assays of both rats and dogs included complete blood profiles, liver function tests, and renal function tests. For rat vitals, monitoring and histopathological analysis were also performed. Converted nanodroplets showed excellent contrast enhancement, better than Sonovue upon in vitro testing, with an enhancement time of up to 14 min. In vivo, experiments showed comparable opacification of the ventricles of both rats and dogs. All biochemical assays remained within the normal range during the study period. The histopathological analysis did not show any signs of drug-induced toxicity, showing the safety of these nanodroplets. Pre-PGS-PFP nanodroplets hold great potential for use in echocardiography and abdominal imaging in both human and veterinary applications after clinical trials.


Assuntos
Meios de Contraste , Ratos Wistar , Ultrassonografia , Animais , Cães , Meios de Contraste/química , Masculino , Ratos , Ultrassonografia/métodos , Nanopartículas/química , Microbolhas , Ecocardiografia/métodos , Fluorocarbonos/química
2.
Nanotheranostics ; 8(4): 427-441, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38961889

RESUMO

Background: The blood-brain barrier (BBB) is a major bottleneck in delivering therapeutics to the brain. Treatment strategies to transiently open this barrier include focused ultrasound combined with intravenously injected microbubbles (FUS+MB) and targeting of molecules that regulate BBB permeability. Methods: Here, we investigated BBB opening mediated by the claudin-5 binder cCPEm (a microorganismal toxin in a truncated form) and FUS+MB at a centre frequency of 1 MHz, assessing dextran uptake, broadband emission, and endogenous immunoglobulin G (IgG) extravasation. Results: FUS+MB-induced BBB opening was detectable at a pressure ≥0.35 MPa when assessed for leakage of 10 and 70 kDa dextran, and at ≥0.2 MPa for uptake of endogenous IgG. Treating mice with 20 mg/kg cCPEm failed to open the BBB, and pre-treatment with cCPEm followed by FUS+MB at 0.2 and 0.3 MPa did not overtly increase BBB opening compared to FUS+MB alone. Using passive cavitation detection (PCD), we found that broadband emission correlated with the peak negative pressure (PNP) and dextran leakage, indicating the possibility of using broadband emission for developing a feedback controller to monitor BBB opening. Conclusions: Together, our study highlights the challenges in developing combinatorial approaches to open the BBB and presents an additional IgG-based histological detection method for BBB opening.


Assuntos
Barreira Hematoencefálica , Claudina-5 , Microbolhas , Animais , Barreira Hematoencefálica/metabolismo , Camundongos , Claudina-5/metabolismo , Imunoglobulina G/metabolismo , Ondas Ultrassônicas , Camundongos Endogâmicos C57BL , Dextranos/química , Dextranos/farmacocinética
3.
Bioresour Technol ; 406: 131082, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38972432

RESUMO

Biobased L-lactic acid (L-LA) appeals to industries; however, existing technologies are plagued by limited productivity and high energy consumption. This study established an integrated process for producing macroalgae-based L-LA from Eucheuma denticulatum phycocolloid (EDP). Dilute acid-assisted microbubbles-mediated ozonolysis (DAMMO) was selected for the ozonolysis of EDP to optimize D-galactose recovery. Through single-factor optimization of DAMMO treatment, a maximum D-galactose recovery efficiency (59.10 %) was achieved using 0.15 M H2SO4 at 80 °C for 75 min. Fermentation with 3 % (w/v) mixed microbial cells (Bacillus coagulans ATCC 7050 and Lactobacillus acidophilus-14) and fermented residues achieved a 97.67 % L-LA yield. Additionally, this culture approach was further evaluated in repeated-batch fermentation and showed an average L-LA yield of 93.30 %, providing a feasible concept for macroalgae-based L-LA production.


Assuntos
Fermentação , Ácido Láctico , Ozônio , Ozônio/farmacologia , Microbolhas , Alga Marinha/metabolismo , Galactose/metabolismo , Bacillus coagulans , Lactobacillus acidophilus/metabolismo , Ácidos Sulfúricos/farmacologia , Biotecnologia/métodos , Algas Comestíveis , Rodófitas
4.
Int J Mol Sci ; 25(13)2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-39000202

RESUMO

The nicotinamide adenine dinucleotide phosphate (NADPH) oxidase 4 (NOX4) protein plays an essential role in the cisplatin (CDDP)-induced generation of reactive oxygen species (ROS). In this study, we evaluated the suitability of ultrasound-mediated lysozyme microbubble (USMB) cavitation to enhance NOX4 siRNA transfection in vitro and ex vivo. Lysozyme-shelled microbubbles (LyzMBs) were constructed and designed for siNOX4 loading as siNOX4/LyzMBs. We investigated different siNOX4-based cell transfection approaches, including naked siNOX4, LyzMB-mixed siNOX4, and siNOX4-loaded LyzMBs, and compared their silencing effects in CDDP-treated HEI-OC1 cells and mouse organ of Corti explants. Transfection efficiencies were evaluated by quantifying the cellular uptake of cyanine 3 (Cy3) fluorescein-labeled siRNA. In vitro experiments showed that the high transfection efficacy (48.18%) of siNOX4 to HEI-OC1 cells mediated by US and siNOX4-loaded LyzMBs significantly inhibited CDDP-induced ROS generation to almost the basal level. The ex vivo CDDP-treated organ of Corti explants of mice showed an even more robust silencing effect of the NOX4 gene in the siNOX4/LyzMB groups treated with US sonication than without US sonication, with a marked abolition of CDDP-induced ROS generation and cytotoxicity. Loading of siNOX4 on LyzMBs can stabilize siNOX4 and prevent its degradation, thereby enhancing the transfection and silencing effects when combined with US sonication. This USMB-derived therapy modality for alleviating CDDP-induced ototoxicity may be suitable for future clinical applications.


Assuntos
Cisplatino , Células Ciliadas Auditivas , Microbolhas , Muramidase , NADPH Oxidase 4 , Ototoxicidade , Espécies Reativas de Oxigênio , Cisplatino/farmacologia , Animais , NADPH Oxidase 4/genética , NADPH Oxidase 4/metabolismo , Camundongos , Células Ciliadas Auditivas/efeitos dos fármacos , Células Ciliadas Auditivas/metabolismo , Espécies Reativas de Oxigênio/metabolismo , Ototoxicidade/genética , Muramidase/genética , RNA Interferente Pequeno/genética , Ondas Ultrassônicas , Técnicas de Silenciamento de Genes , Linhagem Celular
5.
Theranostics ; 14(10): 4076-4089, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38994029

RESUMO

Metastatic tumours in the brain now represent one of the leading causes of death from cancer. Current treatments are largely ineffective owing to the combination of late diagnosis and poor delivery of therapies across the blood-brain barrier (BBB). Conjugating magnetic resonance imaging (MRI) contrast agents with a monoclonal antibody for VCAM-1 (anti-VCAM1) has been shown to enable detection of micrometastases, two to three orders of magnitude smaller in volume than those currently detectable clinically. The aim of this study was to exploit this targeting approach to enable localised and temporary BBB opening at the site of early-stage metastases using functionalised microbubbles and ultrasound. Methods: Microbubbles functionalised with anti-VCAM1 were synthesised and shown to bind to VCAM-1-expressing cells in vitro. Experiments were then conducted in vivo in a unilateral breast cancer brain metastasis mouse model using Gadolinium-DTPA (Gd-DTPA) enhanced MRI to detect BBB opening. Following injection of Gd-DTPA and targeted microbubbles, the whole brain volume was simultaneously exposed to ultrasound (0.5 MHz, 10% duty cycle, 0.7 MPa peak negative pressure, 2 min treatment time). T1-weighted MRI was then performed to identify BBB opening, followed by histological confirmation via immunoglobulin G (IgG) immunohistochemistry. Results: In mice treated with targeted microbubbles and ultrasound, statistically significantly greater extravasation of Gd-DTPA and IgG was observed in the left tumour-bearing hemisphere compared to the right hemisphere 5 min after treatment. No acute adverse effects were observed. There was no investigation of longer term bioeffects owing to the nature of the study. Conclusion: The results demonstrate the feasibility of using targeted microbubbles in combination with low intensity ultrasound to localise opening of the BBB to metastatic sites in the brain. This approach has potential application in the treatment of metastatic tumours whose location cannot be established a priori with conventional imaging methods.


Assuntos
Barreira Hematoencefálica , Neoplasias Encefálicas , Imageamento por Ressonância Magnética , Microbolhas , Molécula 1 de Adesão de Célula Vascular , Animais , Barreira Hematoencefálica/metabolismo , Barreira Hematoencefálica/diagnóstico por imagem , Camundongos , Neoplasias Encefálicas/diagnóstico por imagem , Molécula 1 de Adesão de Célula Vascular/metabolismo , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Feminino , Modelos Animais de Doenças , Ultrassonografia/métodos , Linhagem Celular Tumoral , Gadolínio DTPA/administração & dosagem , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/metabolismo
6.
Phys Med Biol ; 69(14)2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38914104

RESUMO

Objective.Pulsed focused ultrasound (FUS) can deliver therapeutics to the brain by using intravenous microbubbles (MBs) to open the blood-brain barrier (BBB). MB emissions indicate treatment outcomes, like BBB opening (harmonics) and damage (broadband). Typically, a pulse repetition frequency (PRF) of 1 Hz is used, but the effect of PRF on MBs is not fully understood. We investigated the effect of PRF on MB activity and tracer delivery.Approach.The effect of PRF (0.125, 0.25, 0.5, 1, and 2 Hz) on MB activity was monitored through harmonic and wideband emissions during FUS sonications of the rat brain at 274.3 kHz. BBB opening was quantified through fluorescence imaging to estimate the concentration of Trypan Blue (TB) dye following a 75-pulse FUS exposure for PRFs of 1 and 0.25 Hz.Main results.At a fixed acoustic pressure, the percentage change in maximum harmonic amplitude compared to the control (PRF = 1 Hz) decreased with increasing PRF, with a median change of 73.8% at 0.125 Hz and -38.3% at 2 Hz. There was no difference in the pressure threshold for broadband emissions between PRFs of 0.25 and 1 Hz. PRF = 0.25 Hz, led to a 68.2% increase in the mean concentration of TB measured after FUS, with a 53.9% increase in the mean harmonic sum, compared with PRF = 1 Hz. Harmonic emissions-based control at PRF = 0.25 Hz yielded similar TB delivery, with less damage at histology, compared with 1 Hz.Significance.For a fixed number of FUS pulses, reducing the PRF was shown to increase the magnitude of harmonic emissions and TB delivery, but not the threshold for broadband emissions. While further research is necessary to understand the mechanisms involved, these results may be useful to improve clinical safety margins and sensitivity to detecting small harmonic signals from cavitating MBs.


Assuntos
Barreira Hematoencefálica , Sistemas de Liberação de Medicamentos , Microbolhas , Barreira Hematoencefálica/metabolismo , Barreira Hematoencefálica/efeitos da radiação , Animais , Ratos , Ondas Ultrassônicas , Ratos Sprague-Dawley , Masculino , Sonicação/métodos
7.
Microb Cell Fact ; 23(1): 165, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38840167

RESUMO

The increased use of biofuels in place of fossil fuels is one strategy to support the transition to net-zero carbon emissions, particularly in transport applications. However, expansion of the use of 1st generation crops as feedstocks is unsustainable due to the conflict with food use. The use of the lignocellulosic fractions from plants and/or co-products from food production including food wastes could satisfy the demand for biofuels without affecting the use of land and the availability of food, but organisms which can readily ferment all the carbohydrates present in these feedstocks often suffer from more severe bioethanol inhibition effects than yeast. This paper demonstrates the potential of hot gas microbubbles to strip ethanol from a thermophilic fermentation process using Parageobacillus thermoglucosidasius TM333, thereby reducing product inhibition and allowing production to continue beyond the nominal toxic ethanol concentrations of ≤ 2% v/v. Using an experimental rig in which cells were grown in fed-batch cultures on sugars derived from waste bread, and the broth continuously cycled through a purpose-built microbubble stripping unit, it was shown that non/low-inhibitory dissolved ethanol concentrations could be maintained throughout, despite reaching productivities equivalent to 4.7% v/v dissolved ethanol. Ethanol recovered in the condensate was at a concentration appropriate for dewatering to be cost effective and not prohibitively energy intensive. This suggests that hot microbubble stripping could be a valuable technology for the continuous production of bioethanol from fermentation processes which suffer from product inhibition before reaching economically viable titres, which is typical of most thermophilic ethanologenic bacteria.


Assuntos
Biocombustíveis , Etanol , Fermentação , Etanol/metabolismo , Temperatura Alta , Microbolhas , Gases/metabolismo , Bacillaceae/metabolismo
8.
Sci Rep ; 14(1): 8532, 2024 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-38830912

RESUMO

Pancreatic ductal adenocarcinoma (PDAC) poses challenges due to late-stage diagnosis and limited treatment response, often attributed to the hypoxic tumor microenvironment (TME). Sonoporation, combining ultrasound and microbubbles, holds promise for enhancing therapy. However, additional preclinical research utilizing commercially available ultrasound equipment for PDAC treatment while delving into the TME's intricacies is necessary. This study investigated the potential of using a clinically available ultrasound system and phase 2-proven microbubbles to relieve tumor hypoxia and enhance the efficacy of chemotherapy and immunotherapy in a murine PDAC model. This approach enables early PDAC detection and blood-flow-sensitive Power-Doppler sonoporation in combination with chemotherapy. It significantly extended treated mice's median survival compared to chemotherapy alone. Mechanistically, this combination therapy enhanced tumor perfusion and substantially reduced tumor hypoxia (77% and 67%, 1- and 3-days post-treatment). Additionally, cluster of differentiation 8 (CD8) T-cell infiltration increased four-fold afterward. The combined treatment demonstrated a strengthening of the anti-programmed death-ligand 1(αPDL1) therapy against PDAC. Our study illustrates the feasibility of using a clinically available ultrasound system with NH-002 microbubbles for early tumor detection, alleviating hypoxic TME, and improving chemotherapy and immunotherapy. It suggests the development of an adjuvant theragnostic protocol incorporating Power-Doppler sonoporation for pancreatic tumor treatment.


Assuntos
Carcinoma Ductal Pancreático , Imunoterapia , Microbolhas , Neoplasias Pancreáticas , Microambiente Tumoral , Animais , Neoplasias Pancreáticas/terapia , Neoplasias Pancreáticas/tratamento farmacológico , Neoplasias Pancreáticas/patologia , Camundongos , Imunoterapia/métodos , Carcinoma Ductal Pancreático/terapia , Carcinoma Ductal Pancreático/tratamento farmacológico , Carcinoma Ductal Pancreático/patologia , Microambiente Tumoral/efeitos dos fármacos , Linhagem Celular Tumoral , Hipóxia Tumoral/efeitos dos fármacos , Terapia Combinada , Humanos , Feminino
9.
ACS Appl Mater Interfaces ; 16(24): 30755-30765, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38847111

RESUMO

In recent years, enveloped micro-nanobubbles have garnered significant attention in research due to their commendable stability, biocompatibility, and other notable properties. Currently, the preparation methods of enveloped micro-nanobubbles have limitations such as complicated preparation process, large bubble size, wide distribution range, low yield, etc. There exists an urgent demand to devise a simple and efficient method for the preparation of enveloped micro-nanobubbles, ensuring both high concentration and a uniform particle size distribution. Magnetic lipid bubbles (MLBs) are a multifunctional type of enveloped micro-nanobubble combining magnetic nanoparticles with lipid-coated bubbles. In this study, MLBs are prepared simply and efficiently by a magneto internal heat bubble generation process based on the interfacial self-assembly of iron oxide nanoparticles induced by the thermogenic effect in an alternating magnetic field. The mean hydrodynamic diameter of the MLBs obtained was 384.9 ± 8.5 nm, with a polydispersity index (PDI) of 0.248 ± 0.021, a zeta potential of -30.5 ± 1.0 mV, and a concentration of (7.92 ± 0.46) × 109 bubbles/mL. Electron microscopy results show that the MLBs have a regular spherical stable core-shell structure. The superparamagnetic iron oxide nanoparticles (SPIONs) and phospholipid layers adsorbed around the spherical gas nuclei of the MLBs, leading the particles to demonstrate commendable superparamagnetic and magnetic properties. In addition, the effects of process parameters on the morphology of MLBs, including phospholipid concentration, phospholipid proportiona, current intensity, magnetothermal time, and SPION concentration, were investigated and discussed to achieve controlled preparation of MLBs. In vitro imaging results reveal that the higher the concentration of MLBs loaded with iron oxide nanoparticles, the better the in vitro ultrasound (US) imaging and magnetic resonance imaging (MRI) results. This study proves that the magneto internal heat bubble generation process is a simple and efficient technique for preparing MLBs with high concentration, regular structure, and commendable properties. These findings lay a robust foundation for the mass production and application of enveloped micro-nanobubbles, particularly in biomedical fields and other related domains.


Assuntos
Fosfolipídeos , Fosfolipídeos/química , Tamanho da Partícula , Nanopartículas Magnéticas de Óxido de Ferro/química , Nanopartículas de Magnetita/química , Gases/química , Microbolhas , Campos Magnéticos
10.
Ultrasound Med Biol ; 50(8): 1099-1107, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38851940

RESUMO

OBJECTIVE: Ultrasound-triggered bubble-mediated local drug delivery has shown potential to increase therapeutic efficacy and reduce systemic side effects, by loading drugs into the microbubble shell and triggering delivery of the payload on demand using ultrasound. Understanding the behavior of the microbubbles in response to ultrasound is crucial for efficient and controlled release. METHODS: In this work, the response of microbubbles with a coating consisting of poly(2-ethyl-butyl cyanoacrylate) (PEBCA) nanoparticles and denatured casein was characterized. High-speed recordings were taken of single microbubbles, in both bright field and fluorescence. RESULTS: The nanoparticle-loaded microbubbles show resonance behavior, but with a large variation in response, revealing a substantial interbubble variation in mechanical shell properties. The probability of shell rupture and the probability of nanoparticle release were found to strongly depend on microbubble size, and the most effective size was inversely proportional to the driving frequency. The probabilities of both rupture and release increased with increasing driving pressure amplitude. Rupture of the microbubble shell occurred after fewer cycles of ultrasound as the driving pressure amplitude or driving frequency was increased. CONCLUSION: The results highlight the importance of careful selection of the driving frequency, driving pressure amplitude and duration of ultrasound to achieve the most efficient ultrasound-triggered shell rupture and nanoparticle release of protein-and-nanoparticle-stabilized microbubbles.


Assuntos
Sistemas de Liberação de Medicamentos , Microbolhas , Nanopartículas , Nanopartículas/química , Sistemas de Liberação de Medicamentos/métodos , Liberação Controlada de Fármacos , Embucrilato/química , Caseínas/química , Proteínas/química
11.
Phys Med Biol ; 69(13)2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38843808

RESUMO

Objective.Super-resolution ultrasonography offers the advantage of visualization of intricate microvasculature, which is crucial for disease diagnosis. Mapping of microvessels is possible by localizing microbubbles (MBs) that act as contrast agents and tracking their location. However, there are limitations such as the low detectability of MBs and the utilization of a diluted concentration of MBs, leading to the extension of the acquisition time. We aim to enhance the detectability of MBs to reduce the acquisition time of acoustic data necessary for mapping the microvessels.Approach.We propose utilizing phase patterned waves (PPWs) characterized by spatially patterned phase distributions in the incident beam to achieve this. In contrast to conventional ultrasound irradiation methods, this irradiation method alters bubble interactions, enhancing the oscillation response of MBs and generating more significant scattered waves from specific MBs. This enhances the detectability of MBs, thereby enabling the detection of MBs that were undetectable by the conventional method. The objective is to maximize the overall detection of bubbles by utilizing ultrasound imaging with additional PPWs, including the conventional method. In this paper, we apply PPWs to ultrasound imaging simulations considering bubble-bubble interactions to elucidate the characteristics of PPWs and demonstrate their efficacy by employing PPWs on MBs fixed in a phantom by the experiment.Main results.By utilizing two types of PPWs in addition to the conventional ultrasound irradiation method, we confirmed the detection of up to 93.3% more MBs compared to those detected using the conventional method alone.Significance.Ultrasound imaging using additional PPWs made it possible to increase the number of detected MBs, which is expected to improve the efficiency of bubble detection.


Assuntos
Microbolhas , Imagens de Fantasmas , Ultrassonografia , Ultrassonografia/métodos , Meios de Contraste/química
12.
Echocardiography ; 41(6): e15860, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38889076

RESUMO

PURPOSE: Persistent microvascular obstruction (MVO) after successful percutaneous coronary intervention (PCI) in acute ST segment elevation myocardial infarction (STEMI) has been well-described. MVO predicts lack of recovery of left ventricular function and increased mortality. Sonothrombolysis utilizing diagnostic ultrasound induced cavitation of commercially available microbubble contrast has been effective at reducing infarct size and improving left ventricular ejection fraction (LVEF) when performed both pre- and post-PCI. However, the effectiveness of post-PCI sonothrombolysis alone after successful PCI has not been demonstrated. METHODS: A prospective randomized controlled trial was performed in 50 consecutive consenting patients with anterior STEMI who underwent a continuous microbubble infusion immediately following successful PCI. Intermittent high mechanical index (MI) impulses were applied only in the sonthrombolysis group. Delayed enhancement magnetic resonance imaging (MRI) was performed at 48 h and again at 6-8 weeks to assess for differences in infarct size, LVEF, and MVO. RESULTS: There were no differences between groups in age, gender, and cardiovascular risk factors. Significant (> 2 segments) MVO following successful PCI was observed in 66% of patients. Although sonothrombolysis reduced the extent of MVO acutely, there were no differences in infarct size, LVEF, or extent of MVO by MRI at 48 h. Twenty-eight patients returned for a follow up MRI at 6-8 weeks. LVEF improved only in the sonothrombolysis group (∆LVEF 7.81 ± 4.57% with sonothrombolysis vs. 1.77 ± 7.02% for low MI only, p = .011). CONCLUSION: Post-PCI sonothrombolysis had minimal effect on reducing myocardial infarct size but improved left ventricular systolic function in patients with acute anterior wall STEMI.


Assuntos
Intervenção Coronária Percutânea , Humanos , Feminino , Masculino , Intervenção Coronária Percutânea/métodos , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Recuperação de Função Fisiológica , Infarto do Miocárdio/fisiopatologia , Microbolhas , Ecocardiografia/métodos , Microcirculação/fisiologia , Meios de Contraste , Idoso
13.
Ultrason Sonochem ; 108: 106972, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38941703

RESUMO

Sonoporation is a non-invasive method that uses ultrasound for drug and gene delivery for therapeutic purposes. Here, both Finite Element Method (FEM) and Lattice Boltzmann Method (LBM) are applied to study the interaction physics of microbubble oscillation and collapse near flexible tissue. After validating the Finite Element Method with the nonlinear excited lipid-coated microbubble as well as the Lattice Boltzmann Method with experimental results, we have studied the behavior of a three-dimensional compressible microbubble in the vicinity of tissue. In the FEM phase, the oscillation microbubble with a lipid shell interacts with the boundary. The range of pressure and ultrasound frequency have been considered in the field of therapeutic applications of sonoporation. The viscoelastic and interfacial tension as the coating properties of the microbubble shell have been investigated. The presence of an elastic boundary increases the resonance frequency of the microbubble compared to that of a free microbubble. The increase in pressure leads to an expansion in the range of the microbubble's motion, the velocity induced in the fluid, and the shear stress on the boundary walls of tissue. An enhancement in the surface tension of the microbubble can influence fluid flow and reduce the shear stress on the boundary. The multi-pseudo-potential interaction LBM is used to reduce thermodynamic inconsistency and high-density ratio in a two-phase system for modeling the cavitation process. The three-dimensional shape of the microbubble during the collapse stages and the counter of pressure are displayed. There is a time difference between the occurrence of maximum velocity and pressure. All results in detail are presented in the article bodies.


Assuntos
Análise de Elementos Finitos , Microbolhas , Ondas Ultrassônicas , Pressão
14.
Artigo em Inglês | MEDLINE | ID: mdl-38833387

RESUMO

In the development of ultrasound localization microscopy (ULM) methods, appropriate test beds are needed to facilitate algorithmic performance calibration. Here, we present the design of a new ULM-compatible microvascular phantom with a forked, V-shaped wall-less flow channel pair ( 250 µ m channel width) that is bifurcated at a separation rate of 50 µ m/mm. The lumen core was fabricated using additive manufacturing, and it was molded within a polyvinyl alcohol (PVA) tissue-mimicking slab using the lost-core casting method. Measured using optical microscopy, the lumen core's flow channel width was found to be 252 ± 15 µ m with a regression-derived flow channel separation gradient of 50.89 µ m/mm. The new phantom's applicability in ULM performance analysis was demonstrated by feeding microbubble (MB) contrast flow (1.67 to 167 µ L/s flow rates) through the phantom's inlet and generating ULM images with a previously reported method. Results showed that, with longer acquisition times (10 s or longer), ULM image quality was expectedly improved, and the variance of ULM-derived flow channel measurements was reduced. Also, at axial depths near the lumen's bifurcation point, the current ULM algorithm showed difficulty in properly discerning between the two flow channels because of the narrow channel-to-channel separation distance. Overall, the new phantom serves well as a calibration tool to test the performance of ULM methods in resolving small vasculature.


Assuntos
Microvasos , Imagens de Fantasmas , Microvasos/diagnóstico por imagem , Desenho de Equipamento , Algoritmos , Microscopia Acústica/métodos , Microscopia Acústica/instrumentação , Microbolhas , Microscopia/métodos , Microscopia/instrumentação , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Processamento de Imagem Assistida por Computador/métodos
15.
Lab Chip ; 24(14): 3480-3489, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38899528

RESUMO

Optofluidic regulation of blood microflow in vivo represents a significant method for investigating illnesses linked to abnormal changes in blood circulation. Currently, non-invasive strategies are limited to regulation within capillaries of approximately 10 µm in diameter because the adaption to blood pressure levels in the order of several hundred pascals poses a significant challenge in larger microvessels. In this study, using laser-induced microbubble formation within microvessels of the mouse auricle, we regulate blood microflow in small vessels with diameters in the tens of micrometers. By controlling the laser power, we can control the growth and stability of microbubbles in vivo. This controlled approach enables the achievement of prolonged ischemia and subsequent reperfusion of blood flow, and it can also regulate the microbubbles to function as micro-pumps for reverse blood pumping. Furthermore, by controlling the microbubble, narrow microflow channels can be formed between the microbubbles and microvessels for assessing the apparent viscosity of leukocytes, which is 76.9 ± 11.8 Pa·s in the in vivo blood environment. The proposed design of in vivo microbubble valves opens new avenues for constructing real-time blood regulation and exploring cellular mechanics within living organisms.


Assuntos
Lasers , Microbolhas , Microvasos , Animais , Camundongos , Microvasos/fisiologia
16.
Biochem Biophys Res Commun ; 726: 150229, 2024 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-38908346

RESUMO

OBJECTIVE: Mesenchymal stem cells (MSCs) can treat osteoarthritis (OA), but their therapeutic efficacy is poor to date due to low migration efficiency. This study aimed to determine whether ultrasound-targeted microbubble destruction (UTMD) could ameliorate cartilage repair efficiency through facilitating the migration of MSCs via hypoxia-inducible factor-1α (HIF-1α)-mediated glycolysis regulatory pathway in OA model rats. METHODS: OA rats were treated with MSCs alone or in combination with UTMD, respectively, for 4 weeks. Cartilage histopathology, MSCs migration efficiency, von Frey fiber thresholds, and the expression levels of collagen II and MMP-13 were measured. Further, MSCs were extracted from the bone marrow of rats, cocultured with osteoarthritic chondrocytes, transfected to siRNA-HIF-1α, and subjected to UTMD for 4 days. Glucose consumption, lactate production, and cell migration efficiency were assessed. The protein expression levels of HIF-1α, HK2, PKM2, and GLUT1 were measured, respectively. RESULTS: In OA rat model, NC-MSCs + UTMD improved migration efficiency, increased collagen II expression, decreased MMP-13 expression, and delayed osteoarthritis progression. Silencing HIF-1α attenuated the effects induced by UTMD. In vitro, UTMD led to increases in MSC activity and migration, glucose consumption, lactate production, and the protein expression of HIF-1α, HK2, PKM2, and GLUT1 expression, all of which were reversed upon HIF-1α silencing. CONCLUSION: UTMD enhances MSCs migration and improves cartilage repair efficiency through the HIF-1α-mediated glycolytic regulatory pathway, providing a novel therapy strategy for knee osteoarthritis.


Assuntos
Movimento Celular , Glicólise , Subunidade alfa do Fator 1 Induzível por Hipóxia , Células-Tronco Mesenquimais , Microbolhas , Osteoartrite , Ratos Sprague-Dawley , Animais , Células-Tronco Mesenquimais/metabolismo , Células-Tronco Mesenquimais/citologia , Subunidade alfa do Fator 1 Induzível por Hipóxia/metabolismo , Subunidade alfa do Fator 1 Induzível por Hipóxia/genética , Ratos , Osteoartrite/metabolismo , Osteoartrite/terapia , Osteoartrite/patologia , Transplante de Células-Tronco Mesenquimais/métodos , Masculino , Ondas Ultrassônicas , Cartilagem Articular/metabolismo , Cartilagem Articular/patologia , Condrócitos/metabolismo , Células Cultivadas
17.
Nat Commun ; 15(1): 4698, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844770

RESUMO

Given the marginal penetration of most drugs across the blood-brain barrier, the efficacy of various agents remains limited for glioblastoma (GBM). Here we employ low-intensity pulsed ultrasound (LIPU) and intravenously administered microbubbles (MB) to open the blood-brain barrier and increase the concentration of liposomal doxorubicin and PD-1 blocking antibodies (aPD-1). We report results on a cohort of 4 GBM patients and preclinical models treated with this approach. LIPU/MB increases the concentration of doxorubicin by 2-fold and 3.9-fold in the human and murine brains two days after sonication, respectively. Similarly, LIPU/MB-mediated blood-brain barrier disruption leads to a 6-fold and a 2-fold increase in aPD-1 concentrations in murine brains and peritumoral brain regions from GBM patients treated with pembrolizumab, respectively. Doxorubicin and aPD-1 delivered with LIPU/MB upregulate major histocompatibility complex (MHC) class I and II in tumor cells. Increased brain concentrations of doxorubicin achieved by LIPU/MB elicit IFN-γ and MHC class I expression in microglia and macrophages. Doxorubicin and aPD-1 delivered with LIPU/MB results in the long-term survival of most glioma-bearing mice, which rely on myeloid cells and lymphocytes for their efficacy. Overall, this translational study supports the utility of LIPU/MB to potentiate the antitumoral activities of doxorubicin and aPD-1 for GBM.


Assuntos
Barreira Hematoencefálica , Neoplasias Encefálicas , Doxorrubicina , Microbolhas , Receptor de Morte Celular Programada 1 , Doxorrubicina/farmacologia , Doxorrubicina/administração & dosagem , Doxorrubicina/uso terapêutico , Doxorrubicina/análogos & derivados , Animais , Humanos , Receptor de Morte Celular Programada 1/antagonistas & inibidores , Receptor de Morte Celular Programada 1/metabolismo , Camundongos , Barreira Hematoencefálica/metabolismo , Barreira Hematoencefálica/efeitos dos fármacos , Neoplasias Encefálicas/tratamento farmacológico , Neoplasias Encefálicas/imunologia , Neoplasias Encefálicas/patologia , Linhagem Celular Tumoral , Glioma/tratamento farmacológico , Glioma/imunologia , Glioma/patologia , Encéfalo/metabolismo , Encéfalo/efeitos dos fármacos , Feminino , Sistemas de Liberação de Medicamentos , Ondas Ultrassônicas , Glioblastoma/tratamento farmacológico , Glioblastoma/imunologia , Glioblastoma/patologia , Masculino , Microglia/efeitos dos fármacos , Microglia/metabolismo , Camundongos Endogâmicos C57BL , Anticorpos Monoclonais Humanizados/uso terapêutico , Anticorpos Monoclonais Humanizados/administração & dosagem , Anticorpos Monoclonais Humanizados/farmacologia , Inibidores de Checkpoint Imunológico/farmacologia , Inibidores de Checkpoint Imunológico/administração & dosagem , Polietilenoglicóis
19.
Int J Nanomedicine ; 19: 4651-4665, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38799698

RESUMO

Introduction: Recently, nanobubbles (NBs) have gained significant traction in the field of tumor diagnosis and treatment owing to their distinctive advantages. However, the application of NBs is limited due to their restricted size and singular reflection section, resulting in low ultrasonic reflection. Methods: We synthesized a nano-scale ultrasound contrast agent (IR783-SiO2NPs@NB) by encapsulating SiO2 nanoparticles in an IR783-labeled lipid shell using an improved film hydration method. We characterized its physicochemical properties, examined its microscopic morphology, evaluated its stability and cytotoxicity, and assessed its contrast-enhanced ultrasound imaging capability both in vitro and in vivo. Results: The results show that IR783-SiO2NPs@NB had a "donut-type" composite microstructure, exhibited uniform particle size distribution (637.2 ± 86.4 nm), demonstrated excellent stability (30 min), high biocompatibility, remarkable tumor specific binding efficiency (99.78%), and an exceptional contrast-enhanced ultrasound imaging capability. Conclusion: Our newly developed multiple scattering NBs with tumor targeting capacity have excellent contrast-enhanced imaging capability, and they show relatively long contrast enhancement duration in solid tumors, thus providing a new approach to the structural design of NBs.


Assuntos
Meios de Contraste , Nanopartículas , Tamanho da Partícula , Dióxido de Silício , Ultrassonografia , Meios de Contraste/química , Ultrassonografia/métodos , Animais , Nanopartículas/química , Dióxido de Silício/química , Humanos , Linhagem Celular Tumoral , Camundongos , Neoplasias/diagnóstico por imagem , Microbolhas , Camundongos Nus , Camundongos Endogâmicos BALB C , Indóis
20.
ACS Sens ; 9(5): 2356-2363, 2024 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-38752383

RESUMO

Activatable microbubble contrast agents for contrast-enhanced ultrasound have a potential role for measuring physiologic and pathologic states in deep tissues, including tumor acidosis. In this study, we describe a novel observation of increased harmonic oscillation of phosphatidylcholine microbubbles (PC-MBs) in response to lower ambient pH using a clinical ultrasound scanner. MB echogenicity and nonlinear echoes were monitored at neutral and acidic pH using B-mode and Cadence contrast pulse sequencing (CPS), a harmonic imaging technique at 7.0 and 1.5 MHz. A 3-fold increase in harmonic signal intensity was observed when the pH of PC-MB suspensions was decreased from 7.4 to 5.5 to mimic normal and pathophysiological levels that can be encountered in vivo. This pH-mediated activation is tunable based on the chemical structure and length of phospholipids composing the MB shell. It is also reliant on the presence of phosphate groups, as the use of lipids without phosphate instead of phospholipids completely abrogated this phenomenon. The increased harmonic signal likely is the result of increased MB oscillation caused by a decrease of the interfacial tension induced at a lower pH, altering the lipid conformation. While relative signal changes are interpreted clinically as mostly related to blood flow, pH effects could be significant contributors, particularly when imaging tumors. While our observation can be used clinically, it requires further research to isolate the effect of pH from other variables. These findings could pave the way toward for the development of new smart ultrasound contrast agents that expand the clinical utility of contrast-enhanced ultrasound.


Assuntos
Meios de Contraste , Microbolhas , Fosfolipídeos , Ultrassonografia , Concentração de Íons de Hidrogênio , Ultrassonografia/métodos , Fosfolipídeos/química , Meios de Contraste/química , Acústica , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...