Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 320
Filtrar
1.
BMC Ophthalmol ; 24(1): 286, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39009984

RESUMO

BACKGROUND: To compare the surgical outcomes of the inverted internal limiting membrane (ILM) flap technique and ILM insertion for macular hole (MH) without retinal detachment in eyes with extremely high myopia. METHODS: In this retrospective study, we analyzed 22 eyes with an axial length ≥ 30.0 mm that had underwent MH surgery between April 2015 and August 2021. The surgical procedures involved either an inverted ILM flap or ILM insertion. The outcomes were compared between the two techniques. Closure of the MH was confirmed by optical coherence tomography (OCT). The best-corrected visual acuity (BCVA) was measured before and after surgery. Associated complications were documented. RESULTS: The median of axial length was 30.64 mm (range, 30.0-34.42). The MH closed in 100% (22/22) eyes and did not recur with a median follow-up of 12.5 months. For the inverted ILM flap technique, the median BCVA improved significantly from 0.80 logarithm of the minimum angle of resolution (logMAR) (range, 0.40-2.00) before surgery to 0.70 logMAR (range, 0.09-1.52) after surgery (p = 0.002). In addition, the median of final BCVA was better for the inverted ILM flap than ILM insertion (0.7 logMAR V.S. 1.00 logMAR; p = 0.016). CONCLUSIONS: In eyes with extremely high myopia, despite comparable effects on MH closure for both ILM insertion and the inverted ILM flap, the later technique achieved significantly better visual outcomes.


Assuntos
Membrana Basal , Miopia Degenerativa , Perfurações Retinianas , Retalhos Cirúrgicos , Tomografia de Coerência Óptica , Acuidade Visual , Vitrectomia , Humanos , Perfurações Retinianas/cirurgia , Estudos Retrospectivos , Masculino , Feminino , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Tomografia de Coerência Óptica/métodos , Vitrectomia/métodos , Membrana Basal/cirurgia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/complicações , Miopia Degenerativa/fisiopatologia , Idoso , Adulto , Seguimentos
2.
BMC Ophthalmol ; 24(1): 293, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39026209

RESUMO

OBJECTIVE: This study aimed to evaluate and explore the efficacy of pars plana vitrectomy (PPV) combined with internal limiting membrane (ILM) peeling and gas tamponade in treating myopic foveoschisis (MF) through a meta-analysis. METHODS: Systematic searches were conducted on the PubMed, Web of Science and National Library of Medicine (NLM) English-language databases and the China National Knowledge Infrastructure (CNKI) and Wanfang Chinese-language databases. The primary outcome measures were postoperative best-corrected visual acuity (BCVA) and central foveal thickness (CFT), with the secondary outcome being the postoperative complication rate. Data analysis was performed using RevMan5.3 software. RESULTS: A total of 10 studies involving 234 eyes were included. The meta-analysis results showed the following: (1) The average postoperative BCVA improved compared with preoperative levels, with an average improvement in the logarithm of the minimum angle of resolution of 0.40, a statistically significant difference (95% CI: -0.44, - 0.20, p < 0.001); (2) the rate of postoperative BCVA improvement was 77% (95% CI: 65%, 90%, p < 0.001); (3) the postoperative CFT significantly decreased by an average of 385.92 µm, a statistically significant difference (95% CI: -437.85, - 333.98, p < 0.001); (4) the postoperative macular retinal complete reattachment rate was 90% (95% CI: 83%, 97%, p < 0.001); (5) the most common postoperative complication was a cataract, with an incidence of 55.9%. CONCLUSION: Using PPV combined with ILM peeling and gas tamponade to treat MF is reliable.


Assuntos
Membrana Basal , Tamponamento Interno , Retinosquise , Acuidade Visual , Vitrectomia , Humanos , Vitrectomia/métodos , Retinosquise/cirurgia , Tamponamento Interno/métodos , Acuidade Visual/fisiologia , Membrana Basal/cirurgia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/complicações , Miopia Degenerativa/fisiopatologia , Miopia/cirurgia , Miopia/fisiopatologia
3.
J Refract Surg ; 40(7): e490-e498, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007811

RESUMO

PURPOSE: To compare the objective visual quality of moderate-to-high myopia corrected by small incision lenticule extraction (SMILE) and transepithelial photorefractive keratectomy (TransPRK) at a 1,050-Hz ablation frequency, assisted by Smart-Pulse technology (SCHWIND eye-tech-solutions). METHODS: This study involved 123 patients (123 eyes) with moderate-to-high myopia between July 2020 and January 2021. They were categorized into the SMILE group (67 patients, 67 eyes) and the TransPRK group (56 patients, 56 eyes). Follow-ups were conducted at 6 months postoperatively to record the logarithm of the minimum angle of resolution visual acuity, and the Strehl ratio and higher order aberrations were measured using the Sirius anterior segment analysis device (SCHWIND eye-tech-solutions) under a 6-mm pupil diameter at various postoperative intervals. RESULTS: At 1 week and 1 month postoperatively, the uncorrected distance visual acuity (UDVA) in the SMILE group was superior to that in the TransPRK group (P < .05 for both). At 1 week and 1 month postoperatively, the Strehl ratio value in the SMILE group was higher than that in the TransPRK group (P < .05 for both). At 1, 3, and 6 months postoperatively, coma was greater in the SMILE group than in the TransPRK group (P < .05 for all). Spherical aberrations were lower in the SMILE group than in the TransPRK group at 3 and 6 months postoperatively (P < .05). At 6 months postoperatively, UDVA was -0.09 ± 0.08 and -0.11 ± 0.05 logMAR in the SMILE and TransPRK groups, respectively, which exceeded their preoperative corrected distance visual acuity of -0.05 ± 0.04 and -0.09 ± 0.08 logMAR (all P < .001). Compared with preoperative values, the Strehl ratio, total higher order, coma, and spherical aberration differences were significantly increased postoperatively in both groups (all P < .001). CONCLUSIONS: Both surgical methods improved UDVA and each had its advantages. The visual quality of SMILE was superior at 1 week and 1 month postoperatively (Strehl ratio values were higher than those of the TransPRK group), and its spherical aberration was lower than that of the TransPRK group at 3 and 6 months; TransPRK with SmartPulse technology with a 1,050-Hz ablation frequency showed that coma was significantly lower than that of the SMILE group at 1, 3, and 6 months postoperatively. [J Refract Surg. 2024;40(7):e490-e498.].


Assuntos
Substância Própria , Lasers de Excimer , Ceratectomia Fotorrefrativa , Refração Ocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Lasers de Excimer/uso terapêutico , Feminino , Masculino , Ceratectomia Fotorrefrativa/métodos , Adulto , Refração Ocular/fisiologia , Adulto Jovem , Substância Própria/cirurgia , Cirurgia da Córnea a Laser/métodos , Miopia Degenerativa/cirurgia , Miopia Degenerativa/fisiopatologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Topografia da Córnea , Seguimentos , Estudos Prospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Estudos Retrospectivos
4.
J Refract Surg ; 40(6): e381-e391, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38848059

RESUMO

PURPOSE: To investigate the long-term visual quality and rotational stability after the implantation of Implantable Collamer Lens (ICL) and toric ICL (TICL) (STAAR Surgical) in patients with myopia older than 40 years. METHODS: This study included 82 eyes of 41 patients older than 40 years with myopia who underwent ICL/TICL V4c implantation. The refraction sphere, refraction cylinder, spherical equivalent (SE), uncorrected and corrected distance visual acuity, and anterior segmental parameters were measured preoperatively and at the 1-month, 3-month, and last follow-up visits at 33 to 58 months postoperatively (mean follow-up: 42.56 ± 7.17 months). Wavefront aberrations and TICL rotation were measured using OPD-Scan III (Nidek Co Ltd) at the last follow-up visit. RESULTS: At the last follow-up visit, the overall safety and efficacy index were 1.22 ± 0.26 and 0.88 ± 0.34, respectively, without significant differences between the ICL and TICL groups. Postoperative refraction cylinder was -0.95 ± 0.64 and -0.71 ± 0.54 diopters in the ICL and TICL groups, respectively. The average vault was 467.44 ± 231.98 µm. The average TICL rotation was 5.45 ± 6.61 degrees, positively correlated with the preoperative anterior chamber volume (R2 = 0.1118, P = .026) and clockwise TICL alignment degree (R2 = 0.3110, P = .007) and negatively correlated with the 1-month vault (R2 = 0.1218, P = .008). There were no significant differences in the total, corneal, or internal aberrations and modulation transfer function AreaRatio between the ICL and TICL groups. CONCLUSIONS: Both ICL and TICL presented satisfactory long-term safety, efficacy, and visual quality in patients older than 40 years. Postoperative TICL spontaneous rotation was within the manageable range in the long term. [J Refract Surg. 2024;40(6):e381-e391.].


Assuntos
Implante de Lente Intraocular , Miopia Degenerativa , Lentes Intraoculares Fácicas , Refração Ocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Seguimentos , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/cirurgia , Estudos Retrospectivos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Rotação
5.
BMC Ophthalmol ; 24(1): 212, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750496

RESUMO

BACKGROUND: To evaluate differences in log MAR best-corrected visual acuity (BCVA) improvement and postoperative central foveal thickness (CFT) and choroidal thickness (CT) changes between conventional phacoemulsification surgery (CPS) and femtosecond laser-assisted cataract surgery (FLACS) for high-myopia cataracts. METHODS: This was a retrospective and observational study. One hundred and two eyes of 102 patients with high-myopia cataracts were examined. CPS was performed in 54 eyes, and FLACS was performed in 48 eyes. All eyes underwent logMAR BCVA, CFT and CT of three different sectors preoperatively and one week and six months postoperatively. RESULTS: The logMAR BCVA improved significantly after surgery in both groups (both P < 0.001), but no difference was observed in BCVA improvement between the groups (P = 0.554). Moreover, no significant differences were reflected in the changes in CFT, nasal 1 mm CT or temporal 1 mm CT between the two groups, and only subfoveal choroidal thickness (SFCT) in the CPS group decreased significantly compared with that in the FLACS group at any postoperative time (P = 0.003 and 0.026). AL, preoperative logMAR BCVA, and CT of the three regions exhibited a notable correlation with postoperative BCVA (all P < 0.05) according to univariate logistic regression analysis. However, only the AL, preoperative logMAR BCVA and SFCT remained significant in the multivariate model. Postoperative logMAR BCVA revealed a positive correlation with AL and preoperative logMAR BCVA but a negative correlation with SFCT. CONCLUSIONS: FLACS was not superior to CPS in improving BCVA but had less impact on SFCT in the treatment of high-myopia cataracts. Eyes with a longer AL, worse preoperative logMAR BCVA and thinner SFCT had a high risk of worse postoperative BCVA.


Assuntos
Catarata , Terapia a Laser , Facoemulsificação , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Estudos Retrospectivos , Feminino , Masculino , Facoemulsificação/métodos , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Idoso , Terapia a Laser/métodos , Catarata/complicações , Catarata/fisiopatologia , Tomografia de Coerência Óptica/métodos , Macula Lutea/diagnóstico por imagem , Macula Lutea/patologia , Extração de Catarata/métodos , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/complicações , Corioide/diagnóstico por imagem , Resultado do Tratamento
6.
Curr Opin Ophthalmol ; 35(4): 284-291, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38700946

RESUMO

PURPOSE OF REVIEW: Higher degrees of myopia are currently being treated with refractive surgery. However, there is limited characterization and outcomes data for this cohort. This article aims to review the literature on highly myopic patients who had refractive surgery and present a retrospective analysis of 149 patients (270 eyes) with high to extreme myopia (≤-5.0D SE) who underwent refractive surgery [laser-assisted subepithelial keratomileusis (LASIK), photorefractive keratectomy (PRK), or implantable collamer lense (ICL)] at a single practice. RECENT FINDINGS: There is substantial literature on the efficacy of LASIK, PRK, and phakic intraocular lenses for refractive error correction, but a dearth of studies on patients with high to extreme myopia undergoing different types of refractive surgery. Our study reveals that this cohort of patients has excellent outcomes with minimal complications. SUMMARY: Our study reveals that the average preoperative myopia was highest in ICL patients (-10.03D), followed by PRK (-7.21D), and LASIK (-7.04D) patients. Not surprisingly, eyes with high myopia and thin corneas were offered and elected ICLs for their procedure. Highly myopic patients achieved outcomes consistent with data reported in the literature- average postoperative uncorrected visual acuity was 20/20 for LASIK and ICL eyes and 20/25 for PRK eyes.


Assuntos
Ceratectomia Fotorrefrativa , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Resultado do Tratamento , Ceratectomia Fotorrefrativa/métodos , Implante de Lente Intraocular/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Refração Ocular/fisiologia , Estudos Retrospectivos , Miopia Degenerativa/cirurgia , Miopia Degenerativa/fisiopatologia , Miopia/cirurgia , Miopia/fisiopatologia , Lentes Intraoculares Fácicas , Adulto , Masculino , Feminino
7.
Strabismus ; 32(2): 115-120, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38801053

RESUMO

Results: The study cohort comprised five patients, each presenting with unilateral high axial myopia and classic clinical features of HES, including large angle esotropia, hypotropia, and restricted abduction and supraduction. All patients displayed evident superotemporal globe prolapse on MRI imaging, corresponding to the downward displacement of the LR muscle and medial shift of the SR muscle.Following the surgical procedure, all patients demonstrated significant improvements in both vertical and horizontal deviations, effectively addressing the primary clinical manifestations of HES.Conclusions: In the management of HES, several surgical approaches have been explored, yielding mixed results. Our study, employing the technique of partial muscle splitting and scleral fixation, offers a promising avenue for effectively addressing this challenging condition. By adapting the full loop myopexy technique originally proposed by Yokoyama et al. we achieved satisfactory ocular alignment in all five patients. Notably, this approach mitigates the risk of anterior segment ischemia by preserving the unsecured portions of the SR and LR muscles along with MR retroequatorial myopexy.These findings support the consideration of this surgical technique as a safe and effective option for managing HES, providing both cosmetic and functional improvements to afflicted individuals.


Assuntos
Imageamento por Ressonância Magnética , Músculos Oculomotores , Procedimentos Cirúrgicos Oftalmológicos , Humanos , Músculos Oculomotores/cirurgia , Músculos Oculomotores/fisiopatologia , Feminino , Masculino , Procedimentos Cirúrgicos Oftalmológicos/métodos , Adulto , Pessoa de Meia-Idade , Resultado do Tratamento , Esotropia/cirurgia , Esotropia/fisiopatologia , Movimentos Oculares/fisiologia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/complicações
8.
Eye (Lond) ; 38(10): 1933-1940, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38519715

RESUMO

BACKGROUND: This study aims to assess the long term effectiveness, safety, predictability and stability of V4c implantable collamer lenses (ICL) for correction of moderate to extreme high myopia. METHODS: We reviewed 125 eyes from 64 patients who implanted V4c ICL at the Refractive Surgery Center of West China Hospital in Chengdu, China, between May 2015 and January 2017. The median spherical equivalent was -11.50 D (interquartile range [IQR]: -13.00 to -9.00 D). We followed up with the patients over five years and evaluated several parameters, including uncorrected visual acuity (UDVA), corrected visual acuity (CDVA), axial length, refractive error, endothelial cell density (ECD), intraocular pressure (IOP), white-to-white distance (WTW), and vault. We performed a correlation analysis to explore the potential impacts on vault following implantation. RESULTS: The median safety index (postoperative CDVA/preoperative CDVA) during the last follow-up was 1.00 (interquartile range [IQR]: 1.00-1.20), and the efficacy indices (postoperative UDVA/preoperative CDVA) were 1.20 (IQR: 1.00-1.25), 1.20 (IQR: 1.00-1.33), and 0.8 (IQR: 0.65-1.00) at postoperative 1 week, 1 month, and 5 years, respectively. At the five-year mark, 16% of the eyes were within ±0.50 D of expected correction, and 73% were within ±2.00 D. No significant difference in ECD was observed between pre-operative and post-operative measurements. Compared to baseline, we observed a significant increase in IOP at the one-week follow-up, which decreased significantly at the one-month visit. Furthermore, we identified ICL size and spherical equivalent (SE) as independent variables in a multiple linear regression model that accurately predicted the five-year vault after surgery. CONCLUSION: In conclusion, V4c ICL implantation is an effective and safe treatment for moderate to extreme high myopia with good predictability and stability over the long-term.


Assuntos
Pressão Intraocular , Implante de Lente Intraocular , Miopia Degenerativa , Lentes Intraoculares Fácicas , Refração Ocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Masculino , Feminino , Adulto , Implante de Lente Intraocular/métodos , Seguimentos , Pressão Intraocular/fisiologia , Estudos Retrospectivos , Refração Ocular/fisiologia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/fisiopatologia , Adulto Jovem , Resultado do Tratamento , Comprimento Axial do Olho/patologia , Pessoa de Meia-Idade , Miopia/cirurgia , Miopia/fisiopatologia
9.
J Cataract Refract Surg ; 50(7): 733-738, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38446490

RESUMO

PURPOSE: To explore visual outcomes in patients with extreme myopia receiving an implantable collamer lens (ICL) at -18.00 diopters (D), with central port, followed by bioptics by laser vision correction (laser in situ keratomileusis [LASIK] or photorefractive keratectomy [PRK]) to address residual myopia or myopic astigmatism. SETTING: Clínica Baviera (Aier Eye Hospital Group), Bilbao, Spain. DESIGN: Retrospective analysis of cases. METHODS: The study assessed uncorrected distance visual acuity, corrected distance visual acuity (CDVA), predictability, safety, efficacy, and patient satisfaction after implantation of the ICL and bioptics. The model implanted was V4c and EVO, with a correction of -18.00 D. Bioptics were performed at least 3 months after implantation, and patients were followed up for at least 3 months after LASIK or PRK. RESULTS: The analysis included 125 eyes from 90 patients. Of these, 51.2% underwent LASIK and 48.8% PRK. Mean time from implantation to bioptics was 5.9 ± 9.4 months. Patients were followed up for a mean of 40.2 ± 37.9 months after bioptics. Median manifest refractive spherical equivalent was -2.89 D before bioptics and -0.49 D after. Median CDVA was 0.18 logMAR before bioptics and 0.17 after. The mean safety and efficacy indices were 2.22 ± 1.88 and 2.06 ± 1.85, respectively. CONCLUSIONS: Visual outcomes and safety indices after ICL implantation and subsequent LASIK or PRK in patients with extreme myopia are excellent.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Implante de Lente Intraocular , Lentes Intraoculares Fácicas , Ceratectomia Fotorrefrativa , Refração Ocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Estudos Retrospectivos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Ceratectomia Fotorrefrativa/métodos , Masculino , Feminino , Adulto , Refração Ocular/fisiologia , Lasers de Excimer/uso terapêutico , Adulto Jovem , Satisfação do Paciente , Miopia/cirurgia , Miopia/fisiopatologia , Pessoa de Meia-Idade , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/complicações , Astigmatismo/fisiopatologia , Astigmatismo/cirurgia , Resultado do Tratamento
10.
BMC Ophthalmol ; 24(1): 105, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38443856

RESUMO

BACKGROUND: Myopic traction maculopathy (MTM) is a complication of pathological myopia and encompasses various pathological conditions caused by tractional changes in the eye. These changes include retinoschisis, foveal retinal detachment, and lamellar or full-thickness macular holes (FTMHs). This meta-analysis evaluated the safety and efficacy of novel surgical for treating MTM. METHODS: To compare the outcomes of different surgical approaches for MTM, multiple databases, including Web of Science, PubMed, Scopus, ClinicalTrials.gov, the Cochrane Central Register of Controlled Trials, Ovid MEDLINE, Embase, and the Meta-Register of Controlled Trials, were comprehensively searched. The meta-analysis was performed using RevMan 5.1. RESULTS: Nine comparative studies involving 350 eyes were included in this meta-analysis. There were significant differences between fovea-sparing internal limiting membrane peeling (FSIP) and standard internal limiting membrane peeling (ILMP). Preoperative best-corrected visual acuity BCVA (standard mean difference (SMD): -0.10, 95% CI: -0.32 to 0.12) and central foveal thickness CFT (SMD: 0.05, 95% CI: -0.22 to 0.33) were not significantly different (p = 0.39 and p = 0.71, respectively). However, the postoperative BCVA improved significantly (SMD = - 0.47, 95% CI: - 0.80, - 0.14, p = 0.006) in the FSIP group compared to the standard ILMP group. Postoperative CFT did not differ significantly between the two groups (p = 0.62). The FSIP group had a greater anatomical success rate than the other groups, although the difference was not statistically significant (p = 0.26). The incidence of postoperative macular hole formation was significantly lower (OR = 0.19, 95% CI = 0.07-0.54; p = 0.05) in the FSIP group than in the standard ILMP group. The unique characteristics of highly myopic eyes, such as increased axial length and structural changes, may have contributed to the greater incidence of FTMH in the ILMP group. CONCLUSION: Based on the findings of this meta-analysis, FSIP is the initial surgical approach for early-stage MTM and has shown promising outcomes. However, to establish the safest and most efficient surgical technique for treating different MTM stages, further comparative studies, specifically those focusing on ILMP and FSIP, are necessary. TRIAL REGISTRATION: Retrospectively registered.


Assuntos
Degeneração Macular , Miopia Degenerativa , Descolamento Retiniano , Perfurações Retinianas , Humanos , Fóvea Central , Miopia Degenerativa/complicações , Miopia Degenerativa/cirurgia , Perfurações Retinianas/cirurgia
11.
Zhonghua Yan Ke Za Zhi ; 60(3): 234-241, 2024 Mar 11.
Artigo em Chinês | MEDLINE | ID: mdl-38462371

RESUMO

Objective: To investigate the efficacy of pars plana vitrectomy (PPV) without intraocular tamponade in the treatment of high myopic eyes with myopic foveoschisis (MF) accompanied by foveal detachment (FD). Methods: A retrospective case series study was conducted. The medical records of patients diagnosed with unilateral MF accompanied by FD at the Eye & ENT Hospital of Fudan University between May 2018 and December 2021 were collected. All patients underwent 23-gauge PPV with posterior vitreous cortex clearance, and no intraocular tamponade was applied. The cases were divided into groups based on whether the internal limiting membrane was peeled during surgery or retained. Follow-up was conducted for at least 12 months. The main outcome measures included postoperative best-corrected visual acuity (BCVA, converted to logarithm of the minimum angle of resolution), central foveal thickness (CFT), MF resolution, and complications. Statistical analyses were performed using t-tests, chi-square tests, Fisher's exact tests, and univariate and multivariate linear regression. Results: A total of 40 patients (40 eyes) with MF and FD were included in the study, with 30.0% being male and 70.0% female. The mean age was (56.9±11.7) years, and the axial length of the eyes was (29.1±1.9) mm. At 12 months postoperatively, BCVA improved from baseline 1.15±0.58 to 0.73±0.39 (t=6.11, P<0.001), and CFT decreased from baseline (610.1±207.2) µm to (155.9±104.1) µm (t=13.47, P<0.001). Complete resolution of MF with foveal reattachment was observed in 80.0% of eyes, with a median time of 6 (5, 8) months. There was no significant difference in BCVA and CFT between the internal limiting membrane peeled group and retained group [0.68±0.39 vs. 0.79±0.40, t=0.85, P=0.403; (148.3±63.8)vs.(164.3±137.2)um,t=0.48, P=0.634]. One eye experienced macular hole and another eye developed retinal detachment postoperatively. Correlation analysis showed a positive correlation between BCVA at 12 months postoperatively and baseline BCVA (ß=0.433, P<0.001). Conclusions: Pars plana vitrectomy without intraocular tamponade is effective in treating MF accompanied by FD. The choice between internal limiting membrane peeling and retention does not significantly affect visual prognosis.


Assuntos
Miopia Degenerativa , Descolamento Retiniano , Perfurações Retinianas , Retinosquise , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Vitrectomia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/complicações , Estudos Retrospectivos , Retinosquise/cirurgia , Retinosquise/diagnóstico , Retinosquise/etiologia , Tomografia de Coerência Óptica , Membrana Basal/cirurgia , Acuidade Visual , Descolamento Retiniano/cirurgia , Perfurações Retinianas/cirurgia
12.
Zhonghua Yan Ke Za Zhi ; 60(3): 211-214, 2024 Mar 11.
Artigo em Chinês | MEDLINE | ID: mdl-38462367

RESUMO

Myopic maculopathy is the primary cause of irreversible visual impairment in patients with pathologic myopia, and myopic traction maculopathy often requires vitrectomy for treatment. Myopic traction maculopathy encompasses epiretinal membrane, foveoschisis, macular hole, and macular hole-related retinal detachment. It is recommended to perform vitrectomy combined with inner limiting membrane peeling for Type II epiretinal membrane, foveal-sparing inner limiting membrane peeling for foveoschisis, inverted inner limiting membrane flap technique for macular hole, and vitrectomy combined with macular buckle for refractory macular hole-related retinal detachment. Myopic traction maculopathy is a chronically progressive condition, and surgeons need to accurately determine the timing of surgery and choose appropriate procedures to maximize the benefits for patients.


Assuntos
Membrana Epirretiniana , Degeneração Macular , Miopia Degenerativa , Descolamento Retiniano , Perfurações Retinianas , Retinosquise , Humanos , Descolamento Retiniano/etiologia , Perfurações Retinianas/cirurgia , Membrana Epirretiniana/cirurgia , Vitrectomia/métodos , Tração/efeitos adversos , Miopia Degenerativa/complicações , Miopia Degenerativa/cirurgia , Acuidade Visual , Retinosquise/complicações , Retinosquise/cirurgia , Tomografia de Coerência Óptica/métodos , Estudos Retrospectivos
13.
J Cataract Refract Surg ; 50(6): 624-630, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38350159

RESUMO

PURPOSE: To compare the short-term changes in cornea, retina, and choroid of femtosecond laser-assisted cataract surgery (FLACS) with conventional phacoemulsification (CPS) in high myopia patients with cataract. SETTING: Affiliated Hospital of Nantong University, Jiangsu Province, China. DESIGN: Prospective single-center study. METHODS: Demographics, ocular clinical features, ultrasound power, absolute phacoemulsification time, and effective phacoemulsification time were recorded for each patient. Endothelial cell density (ECD), central corneal thickness (CCT), corrected distance visual acuity (CDVA), intraocular pressure (IOP), center foveal thickness (CFT), subfoveal choroidal thickness (SFCT), and choroidal vascularity index (CVI) were evaluated preoperatively and at 1 week, 1 month, and 3 months postoperatively. Intraoperative parameters and intraoperative/postoperative complications were recorded. RESULTS: 97 eyes (46 eyes and 51 eyes in the FLACS and CPS groups, respectively) were included and analyzed. Effective phacoemulsification time was lower in the FLACS group compared with the CPS group ( P < .05). The increase in CCT was significantly lower in the FLACS group compared with the CPS group at 1 week and 1 month ( P < .05). CDVA and IOP were similar in both groups at the final visit ( P > .05). The ECD decreased was lower among CPS patients compared with FLACS patients. CFT, SFCT, and CVI increase in both groups but were increased more in the CPS group with high myopia patients. No serious complications occurred in either group. CONCLUSIONS: FLACS is a more safety and effective in cataract patients with high myopia. It has advantages in effectively reducing EPT and promoting faster recovery of the cornea, macular, and choroidal thickness.


Assuntos
Catarata , Pressão Intraocular , Terapia a Laser , Implante de Lente Intraocular , Miopia Degenerativa , Facoemulsificação , Acuidade Visual , Humanos , Facoemulsificação/métodos , Estudos Prospectivos , Acuidade Visual/fisiologia , Miopia Degenerativa/complicações , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/cirurgia , Masculino , Feminino , Catarata/complicações , Pessoa de Meia-Idade , Terapia a Laser/métodos , Pressão Intraocular/fisiologia , Idoso , Córnea/patologia , Córnea/cirurgia , Corioide/patologia , Contagem de Células , Retina/patologia , Endotélio Corneano/patologia , Complicações Intraoperatórias/prevenção & controle , Complicações Pós-Operatórias/prevenção & controle
15.
Retina ; 44(5): 923-927, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38109723

RESUMO

PURPOSE: To demonstrate through a diagnostic test used as a new preoperative assessment that trocar insertion for pars plana vitrectomy could be safely placed at a distance >4.0 mm in highly myopic eyes to facilitate the surgical maneuvers. METHODS: Thirty eyes of 30 patients were tested with a biometer for the axial length measurement and with ultrasound biomicroscopy to measure the pars plana length. Pars plana lengths of highly myopic eyes were then compared with those of emmetropic eyes. The surgeon also measured the pars plana of highly myopic eyes intraoperatively and compared it with ultrasound measurements to assess ultrasound biomicroscopy reliability. RESULTS: The mean axial length was 23.81 mm (SD ± 0.30) in the control group and 31.11 mm (SD ± 0.56) in the myopic group. The mean pars plana length was 4.96 mm (SD ± 0.19) in control eyes and 6.65 (SD ± 0.36) in myopic eyes. An extremely significant statistical difference ( P < 0.001) was obtained by comparing the length of pars plana between control eyes and myopic eyes. The results of pars plana measurements were 6.65 mm (SD ± 0.36, ultrasound biomicroscopy) and 6.66 mm (SD ± 0.34, intraoperative measurements) in myopic eyes. The statistical comparison of the measurements in these two groups did not give a statistically significant result ( P = 0.950). CONCLUSION: Ultrasound biomicroscopy is a reliable technique to calculate the length of pars plana in highly myopic eyes, where this parameter is significantly greater than that of emmetropic eyes. Trocars insertion for pars plana vitrectomy may be performed, in eyes with axial length >30 mm, in relative safety at a distance to limbus higher than 4 mm.


Assuntos
Comprimento Axial do Olho , Microscopia Acústica , Miopia Degenerativa , Vitrectomia , Humanos , Vitrectomia/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Comprimento Axial do Olho/diagnóstico por imagem , Comprimento Axial do Olho/patologia , Miopia Degenerativa/cirurgia , Idoso , Adulto , Instrumentos Cirúrgicos , Reprodutibilidade dos Testes , Biometria/métodos
16.
Retin Cases Brief Rep ; 18(1): 24-28, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36007186

RESUMO

PURPOSE: To evaluate the efficacy and safety of neodymium-doped yttrium aluminum garnet laser ablation of the internal limiting membrane (ILM) to treat myopic macular retinoschisis. METHODS: Four patients with myopic myopic macular retinoschisis that extended out of the macular area were studied. All patients underwent yttrium aluminum garnet laser ablation of the detached ILM in the paramacular area, and the eyes were examined by ultra-widefield optical coherence tomography at the baseline and 6 months after the treatment. The measured outcomes were the foveal retinal thickness and the best-corrected visual acuity. RESULTS: Neodymium-doped yttrium aluminum garnet laser was applied to the paramacular ILM in all four eyes. In each eye, the procedure failed to disrupt the ILM, and no significant changes were observed in foveal retinal thickness or best-corrected visual acuity subsequently. No serious adverse event occurred in all eyes. A transient intraretinal hemorrhage developed at the site of the application in two eyes but resolved within a week after the treatment. CONCLUSION: Neodymium-doped yttrium aluminum garnet laser was applied to ILM in the peripheral macula in eyes with myopic macular retinoschisis. However, the lack of a reduction of the foveal thickness and improvement of the best-corrected visual acuity indicate that accurate focusing system is needed to treat eyes with myopic macular retinoschisis.


Assuntos
Lasers de Estado Sólido , Degeneração Macular , Miopia Degenerativa , Retinosquise , Humanos , Retinosquise/etiologia , Retinosquise/cirurgia , Lasers de Estado Sólido/uso terapêutico , Miopia Degenerativa/complicações , Miopia Degenerativa/cirurgia , Vitrectomia/métodos , Seguimentos , Acuidade Visual , Tomografia de Coerência Óptica/métodos , Membrana Basal/cirurgia , Estudos Retrospectivos
17.
Ophthalmic Surg Lasers Imaging Retina ; 54(8): 481-484, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37535608

RESUMO

We describe a case of myopic traction maculopathy (MTM) in a patient with low myopia that resolved with surgical intervention. Our patient demonstrated no other features of myopic degeneration and none of the typical tractional elements that cause MTM, such as vitreomacular traction due to partial posterior vitreous detachment (PVD) with vitreomacular adhesion, epiretinal membrane, or a remnant cortical vitreous layer following PVD. Possible pathogenic mechanisms in our patient include reduced compliance of the aging internal limiting membrane and/or traction from elasticity within the thin cortical vitreous layer that forms the posterior wall of the premacular liquefied pocket. [Ophthalmic Surg Lasers Imaging Retina 2023;54:481-484.].


Assuntos
Degeneração Macular , Miopia Degenerativa , Miopia , Doenças Retinianas , Descolamento do Vítreo , Humanos , Tração , Doenças Retinianas/diagnóstico , Doenças Retinianas/etiologia , Retina , Miopia Degenerativa/complicações , Miopia Degenerativa/diagnóstico , Miopia Degenerativa/cirurgia , Tomografia de Coerência Óptica , Estudos Retrospectivos
18.
BMC Ophthalmol ; 23(1): 261, 2023 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-37303059

RESUMO

BACKGROUND: We retrospectively evaluate the long-term efficacy and safety of trabeculotomy glaucoma surgery in treating open-angle glaucoma (OAG) in eyes with high myopia (HM). METHODS: This study included 20 eyes with HM (axial length ≥ 26.5 mm) and OAG; age, preoperative IOP (intraocular pressure), and sex-matched 20 non-HM eyes (axial length < 26.5 mm) served as controls. Each eye underwent standalone ab interno trabeculotomy using a Kahook dual blade. A follow-up examination was performed 36 months after surgery. The main outcome measure was the operative success rate (i.e., a ≥ 20% pre- to post-operative reduction in IOP with or without IOP-lowering medication). Kaplan-Meier analysis was employed as a measure of surgical success. The secondary outcome measures were postoperative IOP, the number of glaucoma medications, and postoperative complications. RESULTS: IOP and the number of glaucoma medications were statistically significantly reduced at all postoperative follow-up examinations. The Kaplan-Meier analysis demonstrated that the probability of postoperative success at 36 months was 45% and 65% for HM and non-HM eyes, respectively. In the HM group, the presence of pathological myopia was statistically significant risk factor for surgical failure. No critical postoperative complications were detected. CONCLUSIONS: In our study, the long-term efficacy of ab interno trabeculotomy in HM eyes with OAG was inferior to that in non-HM eyes with OAG. Our findings suggest that surgical indications for trabeculotomy in HM should be determined based on the presence of pathological myopia.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Miopia Degenerativa , Trabeculectomia , Humanos , Glaucoma de Ângulo Aberto/cirurgia , Miopia Degenerativa/complicações , Miopia Degenerativa/cirurgia , Estudos Retrospectivos , Complicações Pós-Operatórias
19.
BMC Ophthalmol ; 23(1): 150, 2023 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-37041502

RESUMO

BACKGROUND: To investigate the effect of surgical steps optimization in pars plana vitrectomy (PPV) with internal limiting membrane (ILM) flap for macular hole retinal detachment (MHRD) in pathological myopia. METHODS: A retrospective, consecutive, nonrandomized comparative study. High myopic eyes diagnosed with MHRD receiving PPV with ILM flap from March 2019 to June 2020 in Department of Ophthalmology, Xiangya Hospital, Central South University were included in the study. Patients were included into two groups based on different design of surgical steps. In the routine group, extension of posterior vitreous detachment (PVD) towards periphery was performed right after induction of PVD. In the experiment group, the retina was reattached with drainage of subretinal fluid through macular hole before peripheral vitreous was dealt with. Complete ophthalmic examinations were performed before and after surgery. The follow-up time was at least 6 months. The rate of iatrogenic retinal break and length of operation were compared between the two groups. RESULTS: Thirty-one eyes from 31 patients were included in the study with 15 in the experiment group and 16 in the routine group. Demographics showed no statistically significant difference between the two groups. Post-op BCVA, rate of macular hole closure and rate of retinal reattachment were similar in the two groups. The rate of iatrogenic retinal break in the experiment group was significantly lower than that in the routine group (6.7% vs. 37.5%, P < 0.05). The average length of operation was 78.6 ± 18.8 min in the routine group and 64.0 ± 12.1 min in the experiment group (P < 0.05). CONCLUSIONS: Optimized design of surgical steps in PPV for MHRD could effectively decrease the rate of iatrogenic retinal tear and shorten the length of operation.


Assuntos
Miopia Degenerativa , Descolamento Retiniano , Perfurações Retinianas , Humanos , Perfurações Retinianas/cirurgia , Miopia Degenerativa/cirurgia , Descolamento Retiniano/cirurgia , Estudos Retrospectivos , Vitrectomia , Acuidade Visual , Tomografia de Coerência Óptica
20.
BMC Ophthalmol ; 23(1): 172, 2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37085809

RESUMO

BACKGROUND: To compare the clinical outcomes of posterior chamber phakic intraocular lens (pIOL) implantation for non-pathological myopia and pathological myopia. METHODS: This retrospective case series study which were conducted in Beijing Tongren Eye Center between July 2017 and Oct 2021 comprised 192 eyes of 100 consecutive patients undergoing pIOL implantation. Eyes were divided into two groups based on having pathological myopia or not. Predictability, efficacy, safety, and adverse events were compared at 6 months after pIOL implantation. RESULTS: Our study included 86 non-pathological myopes (171 eyes, group1) and 14 pathological myopes (21eyes, group2) to analysis. The average ages were 25.5 and 33.0, respectively, and the spherical equivalent (SE) were -9.31D and -17.50D pre-operation. Six months after pIOL implantation, the SE were 0.00 and -0.50, respectively, and the refraction changes were statistically significant (P ≤ 0.05). Six months after surgery, 76.92% and 80.41% were within ± 0.50 D of the target and 92.31% and 95.88% were within ± 1.00 D. All eyes had unchanged BCVA or gained 1 or more lines in both groups and mean BCVA both improved a line 6m after operation. The efficacy index in the two groups were 0.95 and 0.88 and the safety index were 1.20, 1.33, respectively which was significantly different (P ≤ 0.05). Over the 6-month follow-up, no cataract, pigment dispersion glaucoma, pupillary block, or other vision-threatening complications happened, either. CONCLUSIONS: The pIOL performed well for the correction of both non-pathological and pathological myopia throughout the 6-month observation period. The clinical outcomes of pIOL implantation for non-pathological myopia are essentially equivalent to those for pathological myopia.


Assuntos
Miopia Degenerativa , Lentes Intraoculares Fácicas , Humanos , Acuidade Visual , Estudos Retrospectivos , Seguimentos , Refração Ocular , Miopia Degenerativa/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...