Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 482
Filtrar
1.
Invest Ophthalmol Vis Sci ; 65(8): 6, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38958970

RESUMO

Purpose: The purpose of this study was to evaluate pupillary light reflex (PLR) to chromatic flashes in patients with early-onset high-myopia (eoHM) without (myopic controls = M-CTRL) and with (female-limited myopia-26 = MYP-26) genetic mutations in the ARR3 gene encoding the cone arrestin. Methods: Participants were 26 female subjects divided into 3 groups: emmetropic controls (E-CTRL, N = 12, mean age = 28.6 ± 7.8 years) and 2 myopic (M-CTRL, N = 7, mean age = 25.7 ± 11.5 years and MYP-26, N = 7, mean age = 28.3 ± 15.4 years) groups. In addition, one hemizygous carrier and one control male subject were examined. Direct PLRs were recorded after 10-minute dark adaptation. Stimuli were 1-second red (peak wavelength = 621 nm) and blue (peak wavelength = 470 nm) flashes at photopic luminance of 250 cd/m². A 2-minute interval between the flashes was introduced. Baseline pupil diameter (BPD), peak pupil constriction (PPC), and postillumination pupillary response (PIPR) were extracted from the PLR. Group comparisons were performed with ANOVAs. Results: Dark-adapted BPD was comparable among the groups, whereas PPC to the red light was slightly reduced in patients with myopia (P = 0.02). PIPR at 6 seconds elicited by the blue flash was significantly weaker (P < 0.01) in female patients with MYP-26, whereas it was normal in the M-CTRL group and the asymptomatic male carrier. Conclusions: L/M-cone abnormalities due to ARR3 gene mutation is currently claimed to underlie the pathological eye growth in MYP-26. Our results suggest that malfunction of the melanopsin system of intrinsically photosensitive retinal ganglion cells (ipRGCs) is specific to patients with symptomatic MYP-26, and may therefore play an additional role in the pathological eye growth of MYP-26.


Assuntos
Adaptação à Escuridão , Miopia , Reflexo Pupilar , Opsinas de Bastonetes , Humanos , Feminino , Reflexo Pupilar/fisiologia , Opsinas de Bastonetes/metabolismo , Opsinas de Bastonetes/genética , Adulto , Adulto Jovem , Adaptação à Escuridão/fisiologia , Miopia/fisiopatologia , Miopia/genética , Miopia/metabolismo , Masculino , Estimulação Luminosa , Adolescente , Arrestina/genética , Arrestina/metabolismo , Mutação , Pupila/fisiologia , Luz , Pessoa de Meia-Idade , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/genética
2.
Invest Ophthalmol Vis Sci ; 65(6): 35, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38916884

RESUMO

Purpose: To investigate the characteristics of microperimetry and optical coherence tomography (OCT) in congenital stationary night blindness (CSNB), as well as their structure-function association. Methods: This cross-sectional study included 32 eyes from 32 participants with CSNB, comprising 18 with complete CSNB and 14 with incomplete CSNB, along with 36 eyes from 36 CSNB-unaffected controls matched for age, sex, and spherical equivalent. Using MP-3 microperimetry, central retinal sensitivity was assessed within a 20° field, distributed across six concentric rings (0°, 2°, 4°, 6°, 8°, and 10°). OCT was used to analyze retinal and choroidal thickness. The study aimed to assess the overall and ring-wise retinal sensitivity, as well as choroidal and retinal thickness in CSNB and CSNB-unaffected controls, with a secondary focus on the relationship between retinal sensitivity and microstructural features on OCT. Results: In comparison with CSNB-unaffected subjects, the overall and ring-wise retinal sensitivity as well as choroidal thickness were reduced in patients with CSNB (P < 0.001). Moreover, the central sensitivity in incomplete CSNB group was lower than in complete CSNB group (25.72 ± 3.93 dB vs. 21.92 ± 4.10 dB; P < 0.001). The retinal thickness in the CSNB group was thinner outside the fovea compared with the CSNB-unaffected group. Multiple mixed regression analyses revealed that point-to-point retinal sensitivity was significantly correlated with BCVA (P = 0.002) and the corresponding retinal thickness (P = 0.004). Conclusions: Examination of retinal sensitivity and OCT revealed different spatial distribution profiles in CSNB and its subtypes. In CSNB eyes, retinal sensitivity on microperimetry was associated with retinal thickness on OCT.


Assuntos
Doenças Genéticas Ligadas ao Cromossomo X , Miopia , Cegueira Noturna , Retina , Tomografia de Coerência Óptica , Testes de Campo Visual , Campos Visuais , Humanos , Tomografia de Coerência Óptica/métodos , Feminino , Masculino , Estudos Transversais , Cegueira Noturna/fisiopatologia , Cegueira Noturna/diagnóstico , Testes de Campo Visual/métodos , Campos Visuais/fisiologia , Doenças Genéticas Ligadas ao Cromossomo X/fisiopatologia , Retina/fisiopatologia , Retina/diagnóstico por imagem , Adulto , Miopia/fisiopatologia , Miopia/diagnóstico , Adulto Jovem , Oftalmopatias Hereditárias/fisiopatologia , Oftalmopatias Hereditárias/diagnóstico , Acuidade Visual/fisiologia , Adolescente , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/complicações , Miopia Degenerativa/diagnóstico , Criança , Corioide/patologia , Corioide/diagnóstico por imagem , Corioide/fisiopatologia
3.
Int Ophthalmol ; 44(1): 242, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38904666

RESUMO

PURPOSE: The accuracy of intraocular lens (IOL) calculations is one of the key indicators for determining the success of cataract surgery. However, in highly myopic patients, the calculation errors are relatively larger than those in general patients. With the continuous development of artificial intelligence (AI) technology, there has also been a constant emergence of AI-related calculation formulas. The purpose of this investigation was to evaluate the accuracy of AI calculation formulas in calculating the power of IOL for highly myopic patients. METHODS: We searched the relevant literature through August 2023 using three databases: PubMed, EMBASE, and the Cochrane Library. Six IOL calculation formulas were compared: Kane, Hill-RBF, EVO, Barrett II, Haigis, and SRK/T. The included metrics were the mean absolute error (MAE) and percentage of errors within ± 0.25 D, ± 0.50 D, and ± 1.00 D. RESULTS: The results showed that the MAE of Kane was significantly lower than that of Barrett II (mean difference = - 0.03 D, P = 0.02), SRK/T (MD = - 0.08 D, P = 0.02), and Haigis (MD = - 0.12 D, P < 0.00001). The percentage refractive prediction errors for Kane at ± 0.25 D, ± 0.50 D, and ± 1.00 D were significantly greater than those for SRK/T (P = 0.007, 0.003, and 0.01, respectively) and Haigis (P = 0.009, 0.0001, and 0.001, respectively). No statistically significant differences were noted between Hill-RBF and Barret, but Hill-RBF was significantly better than SRK/T and Haigis. CONCLUSION: The AI calculation formulas showed more accurate results compared with traditional formulas. Among them, Kane has the best performance in calculating IOL degrees for highly myopic patients.


Assuntos
Inteligência Artificial , Lentes Intraoculares , Refração Ocular , Acuidade Visual , Humanos , Refração Ocular/fisiologia , Óptica e Fotônica , Biometria/métodos , Reprodutibilidade dos Testes , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/diagnóstico , Miopia/fisiopatologia , Miopia/diagnóstico
4.
J Refract Surg ; 40(6): e381-e391, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38848059

RESUMO

PURPOSE: To investigate the long-term visual quality and rotational stability after the implantation of Implantable Collamer Lens (ICL) and toric ICL (TICL) (STAAR Surgical) in patients with myopia older than 40 years. METHODS: This study included 82 eyes of 41 patients older than 40 years with myopia who underwent ICL/TICL V4c implantation. The refraction sphere, refraction cylinder, spherical equivalent (SE), uncorrected and corrected distance visual acuity, and anterior segmental parameters were measured preoperatively and at the 1-month, 3-month, and last follow-up visits at 33 to 58 months postoperatively (mean follow-up: 42.56 ± 7.17 months). Wavefront aberrations and TICL rotation were measured using OPD-Scan III (Nidek Co Ltd) at the last follow-up visit. RESULTS: At the last follow-up visit, the overall safety and efficacy index were 1.22 ± 0.26 and 0.88 ± 0.34, respectively, without significant differences between the ICL and TICL groups. Postoperative refraction cylinder was -0.95 ± 0.64 and -0.71 ± 0.54 diopters in the ICL and TICL groups, respectively. The average vault was 467.44 ± 231.98 µm. The average TICL rotation was 5.45 ± 6.61 degrees, positively correlated with the preoperative anterior chamber volume (R2 = 0.1118, P = .026) and clockwise TICL alignment degree (R2 = 0.3110, P = .007) and negatively correlated with the 1-month vault (R2 = 0.1218, P = .008). There were no significant differences in the total, corneal, or internal aberrations and modulation transfer function AreaRatio between the ICL and TICL groups. CONCLUSIONS: Both ICL and TICL presented satisfactory long-term safety, efficacy, and visual quality in patients older than 40 years. Postoperative TICL spontaneous rotation was within the manageable range in the long term. [J Refract Surg. 2024;40(6):e381-e391.].


Assuntos
Implante de Lente Intraocular , Miopia Degenerativa , Lentes Intraoculares Fácicas , Refração Ocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Seguimentos , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/cirurgia , Estudos Retrospectivos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Rotação
5.
Indian J Ophthalmol ; 72(7): 1021-1025, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38905462

RESUMO

PURPOSE: The anterior segment in individuals with high myopia has different features compared to those without myopia. IOLMaster 700 and Oculus Pentacam AXL are two accurate optical biometers. Both devices measure the cornea differently and thus yield different results when measuring intraocular lens (IOL) power. The purpose of this study is to assess the agreement of the IOL power calculation between IOLMaster 700 and Oculus Pentacam AXL in patients with high myopia. METHODS: A prospective, analytical cross-sectional study was conducted to assess the agreement between the IOL power calculation with IOLMaster 700 and Oculus Pentacam AXL. In this study, 44 eyes were examined using Oculus Pentacam AXL and IOLMaster 700, and IOL power was calculated using the Barret Universal II formula and the AMO Sensar AR40E. The Bland-Altman plot was used to evaluate the agreement between the two devices. RESULTS: Based on the IOLMaster 700 examination, 44 eyes with high myopia had axial lengths ranging from 26.05 to 34.02 mm. The mean IOL power was 8.26 ± 4.755 and 8.58 ± 4.776 based on IOLMaster 700 and Oculus Pentacam AXL, respectively. The Bland-Altman plot revealed good agreement between the two devices, with a mean difference of -0.3182 in the IOL power calculation and a 95% LoA of 0.88099-0.24462 with a 95% confidence interval. CONCLUSION: Both devices showed good agreement in the IOL power calculation in patients with high myopia.


Assuntos
Biometria , Lentes Intraoculares , Refração Ocular , Humanos , Estudos Prospectivos , Masculino , Estudos Transversais , Feminino , Biometria/instrumentação , Biometria/métodos , Refração Ocular/fisiologia , Adulto , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Óptica e Fotônica , Miopia/fisiopatologia , Miopia/diagnóstico , Comprimento Axial do Olho , Miopia Degenerativa/diagnóstico , Miopia Degenerativa/fisiopatologia
6.
Int Ophthalmol ; 44(1): 253, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38907787

RESUMO

PURPOSE: To identify risk factors influencing visual outcomes in patients with pathological myopia-associated choroidal neovascularization (PM-CNV) following intravitreal injections of conbercept. METHODS: A total of 86 eyes from 86 patients received intravitreal conbercept in a 1 + PRN regimen. After the initial injection, patients were followed for 12 months. They were categorized into two groups based on their 12-month visual acuity change: those who achieved greater than a one-line improvement in BCVA (improved group; n = 65) and those who experienced a one-line or lesser improvement or a decrease in BCVA (non-improved group; n = 21). RESULTS: Over the 12-month period, the mean BCVA in the improved group significantly improved from 0.82 to 0.41 LogMAR. In the non-improved group, BCVA changed from 1.24 to 1.09 LogMAR. Similarly, the mean CRT decreased from 426.21 µm at baseline to 251.56 µm at 12 months in the improved group, and from 452.47 to 382.45 µm in the non-improved group. Multivariable logistic regression analyses revealed that older age (OR 1.287; 95% CI 1.019-1.625; P = 0.034), poorer baseline BCVA (OR 6.422; 95% CI 1.625-25.384; P = 0.008), the presence of subfoveal CNV (OR 4.817; 95% CI 1.242-18.681; P = 0.023), and organized interlacing patterns of CNV morphology (OR 5.593; 95% CI 1.397-22.392; P = 0.015) emerged as independent risk factors correlated with worsened visual prognosis following intravitreal conbercept injections. CONCLUSIONS: Conbercept demonstrates significant efficacy and safety in treating PM-CNV. Key factors influencing visual recovery post-treatment include older age, poorer baseline BCVA, the presence of subfoveal CNV, and organized interlacing patterns of CNV morphology.


Assuntos
Neovascularização de Coroide , Injeções Intravítreas , Miopia Degenerativa , Proteínas Recombinantes de Fusão , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Neovascularização de Coroide/tratamento farmacológico , Neovascularização de Coroide/etiologia , Neovascularização de Coroide/diagnóstico , Neovascularização de Coroide/fisiopatologia , Masculino , Miopia Degenerativa/complicações , Miopia Degenerativa/diagnóstico , Miopia Degenerativa/fisiopatologia , Feminino , Proteínas Recombinantes de Fusão/administração & dosagem , Pessoa de Meia-Idade , Prognóstico , Tomografia de Coerência Óptica/métodos , Angiofluoresceinografia/métodos , Estudos Retrospectivos , Seguimentos , Adulto , Idoso , Resultado do Tratamento , Inibidores da Angiogênese/administração & dosagem , Fundo de Olho
7.
Strabismus ; 32(2): 115-120, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38801053

RESUMO

Results: The study cohort comprised five patients, each presenting with unilateral high axial myopia and classic clinical features of HES, including large angle esotropia, hypotropia, and restricted abduction and supraduction. All patients displayed evident superotemporal globe prolapse on MRI imaging, corresponding to the downward displacement of the LR muscle and medial shift of the SR muscle.Following the surgical procedure, all patients demonstrated significant improvements in both vertical and horizontal deviations, effectively addressing the primary clinical manifestations of HES.Conclusions: In the management of HES, several surgical approaches have been explored, yielding mixed results. Our study, employing the technique of partial muscle splitting and scleral fixation, offers a promising avenue for effectively addressing this challenging condition. By adapting the full loop myopexy technique originally proposed by Yokoyama et al. we achieved satisfactory ocular alignment in all five patients. Notably, this approach mitigates the risk of anterior segment ischemia by preserving the unsecured portions of the SR and LR muscles along with MR retroequatorial myopexy.These findings support the consideration of this surgical technique as a safe and effective option for managing HES, providing both cosmetic and functional improvements to afflicted individuals.


Assuntos
Imageamento por Ressonância Magnética , Músculos Oculomotores , Procedimentos Cirúrgicos Oftalmológicos , Humanos , Músculos Oculomotores/cirurgia , Músculos Oculomotores/fisiopatologia , Feminino , Masculino , Procedimentos Cirúrgicos Oftalmológicos/métodos , Adulto , Pessoa de Meia-Idade , Resultado do Tratamento , Esotropia/cirurgia , Esotropia/fisiopatologia , Movimentos Oculares/fisiologia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/complicações
8.
BMC Ophthalmol ; 24(1): 212, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750496

RESUMO

BACKGROUND: To evaluate differences in log MAR best-corrected visual acuity (BCVA) improvement and postoperative central foveal thickness (CFT) and choroidal thickness (CT) changes between conventional phacoemulsification surgery (CPS) and femtosecond laser-assisted cataract surgery (FLACS) for high-myopia cataracts. METHODS: This was a retrospective and observational study. One hundred and two eyes of 102 patients with high-myopia cataracts were examined. CPS was performed in 54 eyes, and FLACS was performed in 48 eyes. All eyes underwent logMAR BCVA, CFT and CT of three different sectors preoperatively and one week and six months postoperatively. RESULTS: The logMAR BCVA improved significantly after surgery in both groups (both P < 0.001), but no difference was observed in BCVA improvement between the groups (P = 0.554). Moreover, no significant differences were reflected in the changes in CFT, nasal 1 mm CT or temporal 1 mm CT between the two groups, and only subfoveal choroidal thickness (SFCT) in the CPS group decreased significantly compared with that in the FLACS group at any postoperative time (P = 0.003 and 0.026). AL, preoperative logMAR BCVA, and CT of the three regions exhibited a notable correlation with postoperative BCVA (all P < 0.05) according to univariate logistic regression analysis. However, only the AL, preoperative logMAR BCVA and SFCT remained significant in the multivariate model. Postoperative logMAR BCVA revealed a positive correlation with AL and preoperative logMAR BCVA but a negative correlation with SFCT. CONCLUSIONS: FLACS was not superior to CPS in improving BCVA but had less impact on SFCT in the treatment of high-myopia cataracts. Eyes with a longer AL, worse preoperative logMAR BCVA and thinner SFCT had a high risk of worse postoperative BCVA.


Assuntos
Catarata , Terapia a Laser , Facoemulsificação , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Estudos Retrospectivos , Feminino , Masculino , Facoemulsificação/métodos , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Idoso , Terapia a Laser/métodos , Catarata/complicações , Catarata/fisiopatologia , Tomografia de Coerência Óptica/métodos , Macula Lutea/diagnóstico por imagem , Macula Lutea/patologia , Extração de Catarata/métodos , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/complicações , Corioide/diagnóstico por imagem , Resultado do Tratamento
9.
Curr Opin Ophthalmol ; 35(4): 284-291, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38700946

RESUMO

PURPOSE OF REVIEW: Higher degrees of myopia are currently being treated with refractive surgery. However, there is limited characterization and outcomes data for this cohort. This article aims to review the literature on highly myopic patients who had refractive surgery and present a retrospective analysis of 149 patients (270 eyes) with high to extreme myopia (≤-5.0D SE) who underwent refractive surgery [laser-assisted subepithelial keratomileusis (LASIK), photorefractive keratectomy (PRK), or implantable collamer lense (ICL)] at a single practice. RECENT FINDINGS: There is substantial literature on the efficacy of LASIK, PRK, and phakic intraocular lenses for refractive error correction, but a dearth of studies on patients with high to extreme myopia undergoing different types of refractive surgery. Our study reveals that this cohort of patients has excellent outcomes with minimal complications. SUMMARY: Our study reveals that the average preoperative myopia was highest in ICL patients (-10.03D), followed by PRK (-7.21D), and LASIK (-7.04D) patients. Not surprisingly, eyes with high myopia and thin corneas were offered and elected ICLs for their procedure. Highly myopic patients achieved outcomes consistent with data reported in the literature- average postoperative uncorrected visual acuity was 20/20 for LASIK and ICL eyes and 20/25 for PRK eyes.


Assuntos
Ceratectomia Fotorrefrativa , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Resultado do Tratamento , Ceratectomia Fotorrefrativa/métodos , Implante de Lente Intraocular/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Refração Ocular/fisiologia , Estudos Retrospectivos , Miopia Degenerativa/cirurgia , Miopia Degenerativa/fisiopatologia , Miopia/cirurgia , Miopia/fisiopatologia , Lentes Intraoculares Fácicas , Adulto , Masculino , Feminino
10.
Ophthalmic Physiol Opt ; 44(5): 987-999, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38685756

RESUMO

PURPOSE: The aim of this study was to investigate the microcirculatory characteristics of the dome-shaped macula (DSM), its complications in highly myopic eyes and to explore the factors associated with a DSM. METHODS: This cross-sectional case-control study included a total of 98 subjects (98 eyes): 49 eyes with DSM and 49 eyes without DSM. The axial length (AL) of the myopic eyes was matched 1:1 to eliminate the effect of AL differences on the results. Choroidal (CT) and scleral thickness (ST) and other structural parameters were assessed by swept-source optical coherence tomography (SS-OCT). OCT angiography was used to measure microcirculatory parameters in highly myopic eyes. RESULTS: Subjects with DSM had thinner subfoveal choroidal thickness (46.01 ± 13.25 vs. 81.62 ± 48.26 µm; p < 0.001), thicker subfoveal scleral thickness (SFST; 331.93 ± 79.87 vs. 238.74 ± 70.96 µm; p < 0.001) and thinner foveal CT (66.86 ± 24.65 vs. 107.85 ± 52.65 µm; p < 0.001) compared to subjects without DSM. The foveal choroidal perfusion area (0.72 ± 0.04 vs. 0.76 ± 0.04 mm2; p < 0.001) and foveal choroidal vascularity index (0.15 ± 0.04 vs. 0.33 ± 0.14; p < 0.001) were significantly lower in eyes with DSM. Retinoschisis (81.6% vs. 38.8%; p < 0.001) was more common in eyes with DSM. Eyes with horizontal DSM had worse best-corrected logMAR visual acuity than eyes with round DSM (0.34 ± 0.22 vs. 0.23 ± 0.22; p = 0.03). DSM height (98.95 ± 65.17 vs. 104.63 ± 44.62 µm; p = 0.05) was lower in the horizontal DSM. SFST (OR = 1.06, p = 0.04) and foveal choroidal vascularity index (OR = 0.711, p = 0.02) were significantly associated with DSM. DSM width (p < 0.001), foveal choroidal perfusion area (p = 0.01), foveal choriocapillaris perfusion area (p = 0.02) and parafoveal choroidal vascularity index (p = 0.03) were the most significantly associated factors with DSM height. CONCLUSIONS: The microcirculatory characteristics of eyes with DSM differed from those without DSM. Microcirculatory abnormalities were significantly associated with a DSM. The height of the DSM was associated with decreased blood perfusion.


Assuntos
Angiofluoresceinografia , Macula Lutea , Microcirculação , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Masculino , Feminino , Estudos Transversais , Macula Lutea/irrigação sanguínea , Macula Lutea/diagnóstico por imagem , Macula Lutea/patologia , Microcirculação/fisiologia , Estudos de Casos e Controles , Pessoa de Meia-Idade , Adulto , Angiofluoresceinografia/métodos , Acuidade Visual/fisiologia , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/fisiopatologia , Vasos Retinianos/patologia , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/diagnóstico , Corioide/irrigação sanguínea , Corioide/diagnóstico por imagem , Fundo de Olho
11.
Ophthalmic Physiol Opt ; 44(5): 963-976, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38563652

RESUMO

PURPOSE: To synthesise evidence across studies on factors associated with pathologic myopia (PM) onset and progression based on the META-analysis for Pathologic Myopia (META-PM) classification framework. METHODS: Findings from six longitudinal studies (5-18 years) were narratively synthesised and meta-analysed, using odds ratio (OR) as the common measure of association. All studies adjusted for baseline myopia, age and sex at a minimum. The quality of evidence was rated using the Grades of Recommendation, Assessment, Development and Evaluation framework. RESULTS: Five out of six studies were conducted in Asia. There was inconclusive evidence of an independent effect (or lack thereof) of ethnicity and sex on PM onset/progression. The odds of PM onset increased with greater axial length (pooled OR: 2.03; 95% CI: 1.71-2.40; p < 0.001), older age (pooled OR: 1.07; 1.05-1.09; p < 0.001) and more negative spherical equivalent refraction, SER (OR: 0.77; 0.68-0.87; p < 0.001), all of which were supported by an acceptable level of evidence. Fundus tessellation was found to independently increase the odds of PM onset in a population-based study (OR: 3.02; 2.58-3.53; p < 0.001), although this was only supported by weak evidence. There was acceptable evidence that greater axial length (pooled OR: 1.23; 1.09-1.39; p < 0.001), more negative SER (pooled OR: 0.87; 0.83-0.92; p < 0.001) and higher education level (pooled OR: 3.17; 1.36-7.35; p < 0.01) increased the odds of PM progression. Other baseline factors found to be associated with PM progression but currently supported by weak evidence included age (pooled OR: 1.01), severity of myopic maculopathy (OR: 3.61), intraocular pressure (OR: 1.62) and hypertension (OR: 0.21). CONCLUSIONS: Most PM risk/prognostic factors are not supported by an adequate evidence base at present (an indication that PM remains understudied). Current factors for which an acceptable level of evidence exists (limited in number) are unmodifiable in adults and lack personalised information. More longitudinal studies focusing on uncovering modifiable factors and imaging biomarkers are warranted.


Assuntos
Progressão da Doença , Miopia Degenerativa , Humanos , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/epidemiologia , Miopia Degenerativa/diagnóstico , Fatores de Risco , Refração Ocular/fisiologia
12.
Ophthalmic Physiol Opt ; 44(5): 977-986, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38563586

RESUMO

INTRODUCTION: Research assuming linearity has concluded that corneal biomechanics are compromised in high myopia. We investigated whether this assumption was appropriate and re-examined these associations across different levels of myopia. METHODS: Myopic (spherical equivalent refraction, SER ≤ -0.50 D) eyes of 10,488 adults aged 40-69 years without any history of systemic and ocular conditions were identified in the UK Biobank. Ordinary least squares (OLS) regression was employed to test the linear association between corneal hysteresis (CH) or corneal resistance factor (CRF), separately, and SER while controlling for age, sex, corneal radius and intraocular pressure. Quantile regression (QR) was used to test the same set of associations across 49 equally spaced conditional quantiles of SER. RESULTS: In OLS regression, each standard deviation (SD) decrease in CH and CRF was associated with 0.08 D (95% CI: 0.04-0.12; p < 0.001) and 0.10 D (95% CI: 0.04-0.15; p < 0.001) higher myopia, respectively. However, residual analysis indicated that the linearity assumption was violated. QR revealed no evidence of a significant association between CH/CRF and SER in low myopia, but a significant (p < 0.05) positive association became evident from -2.78 D (0.06 and 0.08 D higher myopia per SD decrease in CH and CRF). The magnitude of association increased exponentially with increasing myopia: in the -5.03 D quantile, every SD decrease in CH and CRF was associated with 0.17 D (95% CI: 0.08-0.25; p < 0.001) and 0.21 D (95% CI: 0.10-0.31; p < 0.001) higher myopia. In the -8.63 D quantile, this further increased to 0.54 D (95% CI: 0.33-0.76; p < 0.001) and 0.67 D (95% CI: 0.41-0.93; p < 0.001) higher myopia per SD decrease in CH and CRF. CONCLUSIONS: Corneal biomechanics appeared compromised from around -3.00 D. These changes were observed to be exponential with increasing myopia.


Assuntos
Córnea , Pressão Intraocular , Refração Ocular , Humanos , Pessoa de Meia-Idade , Córnea/fisiopatologia , Feminino , Masculino , Adulto , Idoso , Fenômenos Biomecânicos , Refração Ocular/fisiologia , Pressão Intraocular/fisiologia , Miopia/fisiopatologia , Miopia/epidemiologia , Elasticidade , Miopia Degenerativa/fisiopatologia
13.
Eye (Lond) ; 38(10): 1933-1940, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38519715

RESUMO

BACKGROUND: This study aims to assess the long term effectiveness, safety, predictability and stability of V4c implantable collamer lenses (ICL) for correction of moderate to extreme high myopia. METHODS: We reviewed 125 eyes from 64 patients who implanted V4c ICL at the Refractive Surgery Center of West China Hospital in Chengdu, China, between May 2015 and January 2017. The median spherical equivalent was -11.50 D (interquartile range [IQR]: -13.00 to -9.00 D). We followed up with the patients over five years and evaluated several parameters, including uncorrected visual acuity (UDVA), corrected visual acuity (CDVA), axial length, refractive error, endothelial cell density (ECD), intraocular pressure (IOP), white-to-white distance (WTW), and vault. We performed a correlation analysis to explore the potential impacts on vault following implantation. RESULTS: The median safety index (postoperative CDVA/preoperative CDVA) during the last follow-up was 1.00 (interquartile range [IQR]: 1.00-1.20), and the efficacy indices (postoperative UDVA/preoperative CDVA) were 1.20 (IQR: 1.00-1.25), 1.20 (IQR: 1.00-1.33), and 0.8 (IQR: 0.65-1.00) at postoperative 1 week, 1 month, and 5 years, respectively. At the five-year mark, 16% of the eyes were within ±0.50 D of expected correction, and 73% were within ±2.00 D. No significant difference in ECD was observed between pre-operative and post-operative measurements. Compared to baseline, we observed a significant increase in IOP at the one-week follow-up, which decreased significantly at the one-month visit. Furthermore, we identified ICL size and spherical equivalent (SE) as independent variables in a multiple linear regression model that accurately predicted the five-year vault after surgery. CONCLUSION: In conclusion, V4c ICL implantation is an effective and safe treatment for moderate to extreme high myopia with good predictability and stability over the long-term.


Assuntos
Pressão Intraocular , Implante de Lente Intraocular , Miopia Degenerativa , Lentes Intraoculares Fácicas , Refração Ocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Masculino , Feminino , Adulto , Implante de Lente Intraocular/métodos , Seguimentos , Pressão Intraocular/fisiologia , Estudos Retrospectivos , Refração Ocular/fisiologia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/fisiopatologia , Adulto Jovem , Resultado do Tratamento , Comprimento Axial do Olho/patologia , Pessoa de Meia-Idade , Miopia/cirurgia , Miopia/fisiopatologia
14.
J Cataract Refract Surg ; 50(7): 733-738, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38446490

RESUMO

PURPOSE: To explore visual outcomes in patients with extreme myopia receiving an implantable collamer lens (ICL) at -18.00 diopters (D), with central port, followed by bioptics by laser vision correction (laser in situ keratomileusis [LASIK] or photorefractive keratectomy [PRK]) to address residual myopia or myopic astigmatism. SETTING: Clínica Baviera (Aier Eye Hospital Group), Bilbao, Spain. DESIGN: Retrospective analysis of cases. METHODS: The study assessed uncorrected distance visual acuity, corrected distance visual acuity (CDVA), predictability, safety, efficacy, and patient satisfaction after implantation of the ICL and bioptics. The model implanted was V4c and EVO, with a correction of -18.00 D. Bioptics were performed at least 3 months after implantation, and patients were followed up for at least 3 months after LASIK or PRK. RESULTS: The analysis included 125 eyes from 90 patients. Of these, 51.2% underwent LASIK and 48.8% PRK. Mean time from implantation to bioptics was 5.9 ± 9.4 months. Patients were followed up for a mean of 40.2 ± 37.9 months after bioptics. Median manifest refractive spherical equivalent was -2.89 D before bioptics and -0.49 D after. Median CDVA was 0.18 logMAR before bioptics and 0.17 after. The mean safety and efficacy indices were 2.22 ± 1.88 and 2.06 ± 1.85, respectively. CONCLUSIONS: Visual outcomes and safety indices after ICL implantation and subsequent LASIK or PRK in patients with extreme myopia are excellent.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Implante de Lente Intraocular , Lentes Intraoculares Fácicas , Ceratectomia Fotorrefrativa , Refração Ocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Estudos Retrospectivos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Ceratectomia Fotorrefrativa/métodos , Masculino , Feminino , Adulto , Refração Ocular/fisiologia , Lasers de Excimer/uso terapêutico , Adulto Jovem , Satisfação do Paciente , Miopia/cirurgia , Miopia/fisiopatologia , Pessoa de Meia-Idade , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/complicações , Astigmatismo/fisiopatologia , Astigmatismo/cirurgia , Resultado do Tratamento
15.
J Glaucoma ; 33(6): 409-416, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38506760

RESUMO

PRCIS: In the group of glaucoma patients with myopia, the more severe the degree of myopia, the faster the loss of visual acuity and central visual field defect. DESIGN: Longitudinal observational study. OBJECTIVE: To investigate the progression rate of myopic glaucoma and associated factors by long-term analysis of its clinical course. METHODS: Patients who had had at least 5 years of follow-up and a spherical equivalent of -0.5 diopters or less were included in this study. They were divided into 3 myopia groups according to myopic grade, namely mild myopia (-0.5 to -3.0 diopters), moderate myopia (-3.0 to -6.0 diopters), and high myopia (-6.0 diopters or more), and the clinical course, progression rate, and associated factors were compared among the groups and analyzed. RESULTS: A total of 121 eyes of 121 patients with glaucoma with myopia were included in the study. The average follow-up period was 10.4 ± 2.9 years. In the analysis of progression rate, the change rate of average retinal nerve fiber layer (RNFL) thickness (-0.75 µm/y in mild myopia, -0.82 µm/y in moderate myopia, -0.84 µm/y in high myopia) and the mean deviation change (-0.30 dB/y in mild myopia, -0.37 dB/y in moderate myopia, -0.39 dB/y in high myopia) both tended to be faster as the myopic grade increased. In a Kaplan-Meier survival analysis, the high myopia groups demonstrated a significantly faster VA loss (of more than 3 lines) and a higher incidence of newly developed central visual field defect (CVFD) than did the mild and moderate myopia groups. Longer axial length (odds ratio: 1.72, CI: 1.03-3.07, P = 0.047) and RNFL defect extending to the macula (odds ratio: 4.14, CI: 1.54-12.30, P = 0.007) were significantly associated with newly developed CVFD. CONCLUSIONS: In patients with myopic glaucoma, the higher the degree of myopia, the faster the rate of visual acuity loss and CVFD occurrence. Occurrence of CVFD was associated with longer axial length and widening of RNFLr defect to the macula.


Assuntos
Progressão da Doença , Pressão Intraocular , Fibras Nervosas , Células Ganglionares da Retina , Acuidade Visual , Campos Visuais , Humanos , Masculino , Feminino , Seguimentos , Campos Visuais/fisiologia , Acuidade Visual/fisiologia , Pressão Intraocular/fisiologia , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica , Adulto , Miopia/fisiopatologia , Miopia/complicações , Fatores de Risco , Idoso , Glaucoma de Ângulo Aberto/fisiopatologia , Glaucoma de Ângulo Aberto/diagnóstico , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/complicações , Testes de Campo Visual , Transtornos da Visão/fisiopatologia , Transtornos da Visão/diagnóstico
16.
J Cataract Refract Surg ; 50(6): 624-630, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38350159

RESUMO

PURPOSE: To compare the short-term changes in cornea, retina, and choroid of femtosecond laser-assisted cataract surgery (FLACS) with conventional phacoemulsification (CPS) in high myopia patients with cataract. SETTING: Affiliated Hospital of Nantong University, Jiangsu Province, China. DESIGN: Prospective single-center study. METHODS: Demographics, ocular clinical features, ultrasound power, absolute phacoemulsification time, and effective phacoemulsification time were recorded for each patient. Endothelial cell density (ECD), central corneal thickness (CCT), corrected distance visual acuity (CDVA), intraocular pressure (IOP), center foveal thickness (CFT), subfoveal choroidal thickness (SFCT), and choroidal vascularity index (CVI) were evaluated preoperatively and at 1 week, 1 month, and 3 months postoperatively. Intraoperative parameters and intraoperative/postoperative complications were recorded. RESULTS: 97 eyes (46 eyes and 51 eyes in the FLACS and CPS groups, respectively) were included and analyzed. Effective phacoemulsification time was lower in the FLACS group compared with the CPS group ( P < .05). The increase in CCT was significantly lower in the FLACS group compared with the CPS group at 1 week and 1 month ( P < .05). CDVA and IOP were similar in both groups at the final visit ( P > .05). The ECD decreased was lower among CPS patients compared with FLACS patients. CFT, SFCT, and CVI increase in both groups but were increased more in the CPS group with high myopia patients. No serious complications occurred in either group. CONCLUSIONS: FLACS is a more safety and effective in cataract patients with high myopia. It has advantages in effectively reducing EPT and promoting faster recovery of the cornea, macular, and choroidal thickness.


Assuntos
Catarata , Pressão Intraocular , Terapia a Laser , Implante de Lente Intraocular , Miopia Degenerativa , Facoemulsificação , Acuidade Visual , Humanos , Facoemulsificação/métodos , Estudos Prospectivos , Acuidade Visual/fisiologia , Miopia Degenerativa/complicações , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/cirurgia , Masculino , Feminino , Catarata/complicações , Pessoa de Meia-Idade , Terapia a Laser/métodos , Pressão Intraocular/fisiologia , Idoso , Córnea/patologia , Córnea/cirurgia , Corioide/patologia , Contagem de Células , Retina/patologia , Endotélio Corneano/patologia , Complicações Intraoperatórias/prevenção & controle , Complicações Pós-Operatórias/prevenção & controle
17.
Graefes Arch Clin Exp Ophthalmol ; 262(7): 2121-2133, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38367069

RESUMO

PURPOSE: To explore the characteristics of macular structure, microcirculation, and foveal avascular zone (FAZ) morphology in pathological myopia and to research the associations between these factors and pathological myopia. METHODS: This is a cross-sectional study. The study included 103 eyes with non-high myopia and 206 eyes with high myopia (139 with simple high myopia and 67 with pathological myopia). Macular structural and microcirculation parameters were determined using optical coherence tomography angiography (OCTA). The FAZ morphological parameters were measured manually using Image J software. Correlations between pathological myopia and various factors were analyzed. RESULTS: Patients with pathological myopia had a thinner retinal thickness (RT) and choroidal thickness (CT) and a lower retinal superficial vascular density (SVD), retinal deep vascular complex density (DVD), choriocapillaris perfusion area (CCPA), and choroidal vascularity index (CVI) (all P < 0.05). Patients with pathological myopia had a larger FAZ area, perimeter, major axis, minor axis, acircularity index (AI), and lower circularity index (CI) (all P < 0.01). The axial length (AL), the major axis of the superficial FAZ, CI, and AI were significantly correlated with myopia severity (all P < 0.05). CONCLUSIONS: Patients with pathological myopia exhibited worse macular microcirculation and thinner macular retina and choroid. The FAZ in pathological myopia was larger and more irregular. The AL, CI, and AI were significantly associated with myopia severity. Thus, CI and AI might serve as new indicators for monitoring the progression of myopia. Further investigations should be performed. TRIAL REGISTRATION: Clinical Trials.gov Identifier: ChiCTR2100046590.


Assuntos
Angiofluoresceinografia , Fóvea Central , Fundo de Olho , Microcirculação , Miopia Degenerativa , Vasos Retinianos , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Masculino , Estudos Transversais , Feminino , Microcirculação/fisiologia , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/diagnóstico , Angiofluoresceinografia/métodos , Vasos Retinianos/patologia , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/fisiopatologia , Fóvea Central/irrigação sanguínea , Fóvea Central/patologia , Adulto , Pessoa de Meia-Idade , Acuidade Visual , Estudos Retrospectivos , Macula Lutea/irrigação sanguínea , Macula Lutea/patologia , Corioide/irrigação sanguínea , Corioide/patologia
18.
Strabismus ; 32(1): 48-53, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38357815

RESUMO

INTRODUCTION: Progressive esotropia accompanied by restricted abduction and supraduction due to high myopia is known as esotropia fixus with high myopia or heavy eye syndrome (HES). Some conditions, such as sagging eye syndrome (SES), show esotropia for distance or cyclovertical strabismus with no abduction limitations despite highly myopic eyes. We evaluated the magnetic resonance imaging (MRI) findings and clinical features of HES, high myopia with SES-like symptoms (highly myopic SES), and SES. METHODS: We reviewed all patients diagnosed with HES, highly myopic SES, and SES who underwent MRI of the orbits and brain over 6 years. To quantitatively assess the orbital anatomy, we compared the conditions of the superior rectus muscle (SR), lateral rectus muscle (LR), and inferior rectus muscle (IR) using orbital MRI among the three groups. RESULTS: Among the 14 patients (27 eyes) with high myopia, 5 (9 eyes) had HES, and 9 (18 eyes) had highly myopic SES. Eleven patients (22 eyes) with SES were also compared with these 14 patients. The mean axial length was 29.6 ± 1.0 mm in participants with HES, 29.0 ± 1.5 mm in those with HES-SES, and 23.7 ± 0.9 mm in those with SES. The average distance esotropia was 48.0 ± 19.9Δprism, 4.6 ± 1.5Δprism, and 6.1 ± 4.6Δprism for participants with HES, highly myopic SES and SES, respectively. The average distance hypertropia was 5.3 ± 5.9Δprism in participants with highly myopic SES and 4.8 ± 2.7Δprism in those with SES. The mean vertical angle of the LR was 32.6 ± 10.8°, 18.1 ± 5.4°, and 14.6 ± 6.8°; the mean tilting angle of the LR was 31.6 ± 9.2°, 15.9 ± 6.0°, and 13.8 ± 5.9°; and the mean displacement angle between the LR and SR was 152.3 ± 16.7°, 125.0 ± 7.1°, and 112.5 ± 7.5° for participants with HES, highly myopic SES and SES, respectively. The LR-SR displacement angle in HES-SES was significantly larger than in SES (p < .001) but the vertical and tilting angles were not. Also, the IR shift showed no significant difference with HES-SES and HES (5.8 ± 1.4 mm and 5.3 ± 1.2 mm) but not with SES (4.0 ± 0.8 mm) (p < .0001). DISCUSSION: SES-like symptoms can develop in highly myopic eyes; however, MRI showed that the state of the LR muscle in highly myopic SES deviated almost similarly to that in SES; however, the eyeball was more dislocated than in SES. This may be useful in deciding the appropriate operative procedure.


Assuntos
Esotropia , Imageamento por Ressonância Magnética , Miopia Degenerativa , Músculos Oculomotores , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Feminino , Músculos Oculomotores/diagnóstico por imagem , Músculos Oculomotores/fisiopatologia , Esotropia/fisiopatologia , Esotropia/diagnóstico por imagem , Esotropia/etiologia , Adulto , Miopia Degenerativa/complicações , Miopia Degenerativa/fisiopatologia , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem , Síndrome , Idoso , Adolescente , Órbita/diagnóstico por imagem , Miopia/complicações , Miopia/fisiopatologia , Movimentos Oculares/fisiologia
19.
Curr Eye Res ; 49(6): 605-614, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38363071

RESUMO

PURPOSE: To investigate the influence of lens thickness (LT) on accuracy of Kane, Hill-RBF 3.0 Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO), and Pearl-DGS formulas in eyes with different axial lengths (AL). METHODS: The prospective cohort study was conducted at Eye and ENT Hospital of Fudan University. Patients who had uneventful cataract surgery between March 2021 and July 2023 were recruited. Manifest refraction was conducted two-month post-surgery. Eyes were divided into 4 groups based on AL: short (<22mm), medium (22-24.5 mm), medium long (24.5-26mm) and very long (≥26mm). In each AL group, eyes were then divided into 3 subgroups based on the LT measured with IOLmaster700: thin (<4.5 mm), medium (4.5-5.0 mm), and thick (≥ 5 mm). The influence of LT on accuracy of Kane, Hill-RBF 3.0, BUII, EVO, and Pearl-DGS formulas were investigated in each AL group. RESULTS: A total of 327 eyes from 327 patients were analyzed, with 64, 102, 73 and 88 eyes in each AL group, respectively. In eyes with AL < 24.5 mm, myopic PE was significantly associated with greater LT using all the 5 formulas (all p < 0.05). Backward stepwise multivariate regression analyses revealed that LT was an important influencing factor for PE in all 5 formulas, particularly in eyes with AL <24.5 mm. In eyes with AL <24.5 mm and LT > 5.0 mm, PE of all 5 formulas calculated with the optional parameter LT were more myopic than those calculated without LT. CONCLUSIONS: Thicker LT was associated with more myopic PE among eyes with AL <24.5 mm when using all 5 formulas. Further optimization of current formulas is necessary, especially for eyes with short AL and thick LT.


Assuntos
Comprimento Axial do Olho , Biometria , Emetropia , Cristalino , Miopia Degenerativa , Refração Ocular , Humanos , Estudos Prospectivos , Masculino , Feminino , Refração Ocular/fisiologia , Comprimento Axial do Olho/patologia , Emetropia/fisiologia , Biometria/métodos , Pessoa de Meia-Idade , Cristalino/patologia , Cristalino/diagnóstico por imagem , Idoso , Miopia Degenerativa/diagnóstico , Miopia Degenerativa/fisiopatologia , Acuidade Visual , Óptica e Fotônica , Lentes Intraoculares , Implante de Lente Intraocular , Reprodutibilidade dos Testes , Miopia/fisiopatologia , Miopia/diagnóstico
20.
Acta Ophthalmol ; 102(5): e762-e773, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38279584

RESUMO

PURPOSE: To evaluate the structural, microvascular, and functional progression of normal tension glaucoma (NTG) with or without high myopia by examining longitudinal changes in optical coherence tomography angiography (OCTA) and visual field (VF) parameters. METHODS: We evaluated 61 NTG eyes and classified 25 of the eyes with axial lengths (ALs) of ≥26 mm as highly myopic. We assessed the rate of change in OCTA parameters, namely radial peripapillary capillary (RPC) vessel density (VD), parafovea VD, deep parafovea VD, retinal nerve fibre layer (RNFL) thickness, and ganglion cell complex thickness. We evaluated the correlation of the rate of change in OCTA parameters with VF loss and AL. RESULTS: Among the 61 NTG eyes, rates of loss of RPC VD, parafovea VD, deep parafovea VD, and RNFL thickness were significantly different from zero despite the nonsignificant rate of change in VF mean deviation (MD). Changes in these OCTA parameters did not differ significantly in highly myopic NTG eyes. The rate of change in VF MD was significantly correlated with the rate of change in parafovea VD in highly myopic and non-highly myopic NTG eyes. In highly myopic NTG eyes, AL was negatively correlated with the rates of loss of RNFL thickness, VF MD, and VF PSD. CONCLUSION: NTG eyes with a relatively stable VF exhibited loss of VD and RNFL thickness. VF progression in NTG was correlated with decreasing parafovea VD, indicating a structure-function correlation. Greater AL may indicate faster VF loss and RNFL thinning in highly myopic NTG eyes.


Assuntos
Angiofluoresceinografia , Pressão Intraocular , Glaucoma de Baixa Tensão , Fibras Nervosas , Disco Óptico , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Campos Visuais , Humanos , Tomografia de Coerência Óptica/métodos , Glaucoma de Baixa Tensão/fisiopatologia , Glaucoma de Baixa Tensão/diagnóstico , Masculino , Feminino , Campos Visuais/fisiologia , Pessoa de Meia-Idade , Angiofluoresceinografia/métodos , Células Ganglionares da Retina/patologia , Fibras Nervosas/patologia , Pressão Intraocular/fisiologia , Disco Óptico/irrigação sanguínea , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia , Idoso , Seguimentos , Progressão da Doença , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/diagnóstico , Miopia Degenerativa/complicações , Estudos Retrospectivos , Fundo de Olho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...