Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.801
Filtrar
1.
Transl Vis Sci Technol ; 13(6): 20, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38916880

RESUMO

Purpose: Surgical innovation in ophthalmology is impeded by the physiological limits of human motion, and robotic assistance may facilitate an expansion of the surgical repertoire. We conducted a systematic review to identify ophthalmic procedures in which robotic systems have been trialled, evaluate their performance, and explore future directions for research and development of robotic techniques. Methods: The Cochrane Library, Embase, MEDLINE, Scopus, and Web of Science were searched. Screening adhered to five criteria: (1) English language; (2) primary research article; (3) human patients; (4) ophthalmological surgery; and (5) robot-assisted surgery. Quality assessment was conducted with Joanna Briggs Institute Tools for Critical Appraisal. The study protocol was registered prospectively (PROSPERO ID CRD42023449793). Results: Twelve studies were included. In comparative studies, there was no difference in the occurrence of ocular harms in robot-assisted procedures and conventional surgery. However, robotic assistance did not demonstrate consistent benefits over manual surgery in terms of effectiveness or practicality, likely reflecting the learning curve associated with these systems. Single studies indicated the potential of robotic assistance to improve the consistency of subretinal drug infusion and efficiency of instrument manipulation in vitreoretinal surgery. Conclusions: Proof-of-concept studies have demonstrated the potential of robotic assistance to facilitate procedures otherwise infeasible or impractical, and may broaden access to surgery. However, robot-assisted surgery has not yet demonstrated any significant benefits over standard surgical practice. Improving the speed and reducing perioperative requirements of robot-assisted surgery are particular priorities for research and innovation to improve the practicality of these novel techniques. Translational Relevance: This systematic review summarizes the potential and limitations of robotic systems for assisting eye surgery and outlines what is required for these systems to benefit patients and surgeons.


Assuntos
Procedimentos Cirúrgicos Oftalmológicos , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Oftalmopatias/cirurgia
2.
Cesk Slov Oftalmol ; 80(Ahead of print): 1-8, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38925901

RESUMO

AIM: To summarize the history and current trends in the use of scleral grafts in ophthalmology. MATERIALS AND METHODS: We conducted a review of the literature through the MEDLINE and Cochrane Library databases. The search terms were "sclera", "graft", and "surgery". The search resulted in 1596 articles, of which we evaluated 192 as relevant. The relevant articles were sorted chronologically and according to the method of using scleral grafts, which enabled the development of a review article. RESULTS: The sclera has been routinely used in ophthalmology since the 1950s in many different indications. Some of these indications have become practically obsolete over time (for example, use in the surgical management of retinal detachment), but a large number still find application today (especially use in glaucoma or oculoplastic surgery, or as a patch for a defect in the sclera or cornea). CONCLUSION: Even though allogeneic sclera is currently used less frequently in ophthalmology compared to other tissue banking products and the range of its indications has partially narrowed, it remains a useful material due to its availability and properties.


Assuntos
Esclera , Esclera/cirurgia , Esclera/transplante , Humanos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Oftalmopatias/cirurgia
3.
BMC Ophthalmol ; 24(1): 140, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38549111

RESUMO

BACKGROUND: An ocular osseous choristoma is a growth of mature, compact bone in the ocular or periocular soft tissue, and it is the rarest form of ocular choristoma, accounting for only 1.7% of all epibulbar choristomas. CASE PRESENTATION: Herein we present the case of a 20-month-old girl who was referred to the oculoplasty clinic with a progressively growing mass in the left lateral canthus. It had been present since birth without ocular involvement. Upon examination the mass was firm with a smooth surface, measured 9 × 6 × 3 mm, and exhibited no episcleral attachment or ocular involvement. An excisional biopsy was performed, and the histopathological findings were consistent with osseous choristoma of the left lateral canthus. CONCLUSIONS: This report highlights the importance of considering osseous choristoma in the differential diagnosis of eyelid lesions, particularly those that have been present since birth. It also emphasizes the need for further studies investigating associations between osseous choristomas and ocular canthi.


Assuntos
Coristoma , Oftalmopatias , Aparelho Lacrimal , Feminino , Humanos , Lactente , Coristoma/diagnóstico , Coristoma/cirurgia , Coristoma/patologia , Aparelho Lacrimal/patologia , Oftalmopatias/cirurgia , Pálpebras/patologia , Osso e Ossos/patologia
4.
Acta Ophthalmol ; 102(5): e789-e796, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38308458

RESUMO

BACKGROUND: The 30-day readmission rate provides a standardised quantitative evaluation of some postoperative complications. It is widely used worldwide in many medical and surgical specialities, and the World Health Organization recommends its use for monitoring healthcare system performance. In ophthalmology, its measurement is biased by the frequent and close planned surgery on one eye and then the other, particularly in the case of cataract surgery. This study measures the 30-day unplanned readmission rate in ophthalmology, globally and by surgery subtype, and describes the causes of readmission. METHODS: All patients readmitted within 30 days of ophthalmic surgery at Nantes University Hospital between January 2017 and December 2020 were identified in the Medical Information System. An ophthalmologist examined each medical record and collected the following data: the reason for readmission, comorbidities, the pathology treated, surgery type, surgery duration, the surgeon's experience, anaesthesia type, severity and readmission morbidity. RESULTS: For the 8522 ophthalmic surgeries performed in the four-year study period, 282 30-day unplanned readmissions were identified. The overall 30-day unplanned readmission rate was 2.07% for elective surgery, with a high variability depending on the surgery type: 0.95% for phacoemulsification, 4.95% for vitreoretinal surgery (3.42% for non-elective vitreoretinal surgery, 5.44% for retinal detachment surgery), 5.66% for deep lamellar keratoplasty and 11.90% for trabeculectomy. The unplanned 30-day readmission rate for ocular trauma surgery (emergency care) was 11.0%. Seven percent of all unplanned 30-day readmissions were not associated with an ophthalmological problem. CONCLUSIONS: This study is the first to report 30-day unplanned readmission in ophthalmology, globally and by surgical subtype, for elective and urgent procedures. This indicator can be used longitudinally to detect an increase in risk or transversely to compare the quality of care between different public or private hospitals.


Assuntos
Procedimentos Cirúrgicos Oftalmológicos , Readmissão do Paciente , Complicações Pós-Operatórias , Indicadores de Qualidade em Assistência à Saúde , Humanos , Readmissão do Paciente/estatística & dados numéricos , Feminino , Masculino , Complicações Pós-Operatórias/epidemiologia , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Adulto , Fatores de Tempo , Seguimentos , Idoso de 80 Anos ou mais , Oftalmopatias/cirurgia , Adolescente
5.
J AAPOS ; 28(1): 103827, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38253286

RESUMO

PURPOSE: To determine the postoperative fundus torsion following surgical inferior oblique (IO) weakening in patients with inferior oblique overaction (IOOA). METHODS: In this interventional case series, 37 patients with IOOA ≥ +1 and reliable preoperative fundus photographs were included. IO weakening was accomplished through myectomy or anterior transposition. Fundus photography was repeated at 3 months' follow-up. The primary outcome was change of disk foveal angle (DFA), measured as the angle between the line connecting the center of the fovea and optic disk and horizontal. Success or normal fundus torsion was defined as a postoperative angle of 0° to 8° of extorsion. Residual extorsion was defined as postoperative extorsion of > 8°. Postoperative intorsion was defined as any amount of induced intorsion. RESULTS: Mean age of patients (56% females) was 6.46 ± 6.79 years. At follow-up at least 3 months after surgery, the mean change of DFA was 7.79 ± 6.24° of reduction of extorsion after IO myectomy (P < 0.001) and 6.05 ± 6.07° after IO anterior transposition (P = 0.005). Normal fundus torsion was achieved in 50% of patients after myectomy and 36.4% of patients after anterior transposition. Residual extorsion was observed in 49% of patients; induced intorsion in 5%. CONCLUSIONS: Using objective measurement of fundus photographs, fundus extorsion was decreased in 94.7% of patients after myectomy or anterior transposition.


Assuntos
Oftalmopatias , Transtornos da Motilidade Ocular , Doenças Orbitárias , Estrabismo , Feminino , Humanos , Criança , Adolescente , Masculino , Músculos Oculomotores/cirurgia , Anormalidade Torcional/diagnóstico , Anormalidade Torcional/cirurgia , Transtornos da Motilidade Ocular/cirurgia , Oftalmopatias/cirurgia , Fundo de Olho , Doenças Orbitárias/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Resultado do Tratamento , Estrabismo/cirurgia , Estudos Retrospectivos
6.
Eye (Lond) ; 38(4): 668-679, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37875701

RESUMO

The amniotic membrane is a single epithelial layer of the placenta. It has anti-inflammatory, anti-scarring, anti-angiogenic and possibly bactericidal properties. The basement membrane of the amniotic membrane acts as a substrate to encourage healing and re-epithelialisation. It has been used in many ocular surface diseases including persistent epithelial defects (corneal or conjunctival), chemical or thermal burns, limbal stem cell deficiency, cicatrising conjunctivitis, ocular graft versus host disease, microbial keratitis, corneal perforation, bullous keratopathy, dry eye disease, corneal haze following refractive surgery and cross-linking, band keratopathy, ocular surface neoplasia, pterygium surgery, and ligneous conjunctivitis. This review provides an up-to-date overview of amniotic membrane transplantation including the structural and biological properties, preparation and application, clinical indications, and commercially available products.


Assuntos
Conjuntivite , Doenças da Córnea , Distrofias Hereditárias da Córnea , Oftalmopatias , Feminino , Gravidez , Humanos , Âmnio/transplante , Oftalmopatias/cirurgia , Córnea , Doenças da Córnea/cirurgia
7.
J Vet Intern Med ; 38(1): 388-397, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37982362

RESUMO

BACKGROUND: Pain recognition in hospitalized horses is challenging, and the utility of pain scoring systems in horses with ocular disease has not been well-described. HYPOTHESIS/OBJECTIVES: Evaluate the horse grimace scale (HGS) and behavior pain score (BPS) in hospitalized horses with ocular disease. We hypothesized that HGS and BPS would be associated with different clinical progressions. ANIMALS: Privately owned horses hospitalized for ocular disease between September 2018 and September 2020. METHODS: Retrospective observational study. The HGS and BPS were recorded daily throughout hospitalization. Clinical progressions were categorized as: (a) discharge from hospital after medical treatment, (b) ophthalmic surgery (eg, keratectomy, conjunctival flap, amniotic membrane transplantation, corneal transplant), or (c) enucleation. Temporal trends in HGS and BPS were assessed using linear regression. Correlations among slope, intercept, and progression were determined using the Kruskal-Wallis test. RESULTS: Of 65 horses that met inclusion criteria, 29 (45%) were discharged after exclusively medical management, 28 (43%) underwent ophthalmic surgery, and 8 (12%) underwent enucleation. Two horses (3%) had 2 ophthalmic surgeries performed. The BPS scores at admission were higher in horses that were managed medically than in those that underwent enucleation (P = .01). Horses requiring enucleation had higher increases in HGS (P = .02) and BPS (P = .01) during hospitalization than horses that were medically managed and a higher increase in BPS (P = .04) than horses that required ophthalmic surgery. CONCLUSIONS AND CLINICAL IMPORTANCE: Pain scoring may represent a useful tool for monitoring progression and response to treatment in hospitalized horses with ocular disease.


Assuntos
Oftalmopatias , Doenças dos Cavalos , Cavalos , Animais , Dor/veterinária , Hospitalização , Oftalmopatias/cirurgia , Oftalmopatias/veterinária , Estudos Retrospectivos , Doenças dos Cavalos/cirurgia
8.
BMC Ophthalmol ; 23(1): 504, 2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38087284

RESUMO

PURPOSE: To compare the effectiveness and safety of a 27-gauge (27G) beveled-tip microincision vitrectomy surgery (MIVS) with a 25-gauge (25G) flat-tip MIVS for the treatment of proliferative diabetic retinopathy (PDR). METHODS: A prospective, single-masked, randomized, controlled clinical trial included 52 eyes (52 patients) with PDR requiring proliferative membrane removal. They were randomly assigned in a 1:1 ratio to undergo the 27G beveled-tip and or 25G flat-tip MIVS (the 27G group and the 25G group, respectively). During surgery, the productivity of cutting the membrane, the number of vitrectomy probe (VP) exchanges to microforceps, total operation time, vitrectomy time and intraoperative complications were measured. Best-corrected visual acuity (BCVA), intraocular pressure (IOP) and postoperative complications were also assessed to month 6. RESULTS: Forty-seven eyes (47 patients) completed the follow-up, including 25 in the 27G group and 22 in the 25G group. During surgery in the 27G group, cutting the membrane was more efficient (P = 0.001), and the number of VP exchanges to microforceps was lower (P = 0.026). The occurrences of intraoperative hemorrhages and electrocoagulation also decreased significantly (P = 0.004 and P = 0.022). There were no statistical differences in the total operation time or vitrectomy time between the two groups (P = 0.275 and P = 0.372), but the former was slightly lower in the 27G group. Additionally, the 27G group required fewer wound sutures (P = 0.044). All the follow-up results revealed no significant difference between the two groups. CONCLUSIONS: Compared with the 25G flat-tip MIVS, the 27G beveled-tip MIVS could be more efficient in removing the proliferative membrane while reducing the occurrence of intraoperative hemorrhages and electrocoagulation using appropriate surgical techniques and instrument parameters. Its vitreous removal performance was not inferior to that of the 25G MIVS and might offer potential advantages in total operation time. In terms of patient outcomes, advanced MIVS demonstrates equal effectiveness and safety to 25G flat-tip MIVS. TRIAL REGISTRATION: The clinical trial has been registered at Clinicaltrials.gov (NCT0544694) on 07/07/2022. And all patients in the article were enrolled after registration.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Oftalmopatias , Humanos , Vitrectomia/métodos , Retinopatia Diabética/cirurgia , Estudos Prospectivos , Oftalmopatias/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Hemorragia/cirurgia , Estudos Retrospectivos
9.
Artigo em Inglês | MEDLINE | ID: mdl-38082703

RESUMO

Ophthalmic surgery, which addresses critical eye diseases such as retinal disorders, remains a formidable and arduous surgical pursuit. Nevertheless, with the advent of cutting-edge robotics and automation technology, significant advancement has been made in recent years to enhance the safety and efficacy of these procedures through meticulous research and development efforts. Ensuring the safe and effective execution of micro-surgical procedures requires stringent quality control measures, notably concerning evaluating and testing the devices utilized. During the development phase, these instruments must undergo extensive and continual evaluation by clinical practitioners to guarantee their safety and efficacy. Ideally, the test conditions should be identical to those of an actual operation. When testing robotic systems for ophthalmology, essential variables of the human eye, such as tissue properties and movement mechanisms, should be addressed. To minimize the discrepancy of tests and actual eye surgery conditions, in this paper, we propose a developed mechanical eye model to enable the realistic evaluation of ophthalmic surgical systems. After developing a virtual and physical model, the model was tested by an eye surgeon. The eye surgeon rated the model with four out of five possible points.Clinical relevance- This method ensures minimal discrepancy in verification of ophthalmic surgical devices by allowing the mechanical eye model to behave similar to the human eye, thus providing a realistic surgical procedure.


Assuntos
Oftalmopatias , Oftalmologia , Robótica , Humanos , Procedimentos Cirúrgicos Oftalmológicos , Oftalmopatias/diagnóstico , Oftalmopatias/cirurgia
10.
Am J Case Rep ; 24: e942279, 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38051696

RESUMO

BACKGROUND We report a case of late-onset chronic fistula in a decompensated cornea after multiple ocular surgeries and a recent phototherapeutic keratectomy (PTK). CASE REPORT A 73-year-old woman presented to our service with a past ocular history of bilateral chronic angle closure glaucoma and pseudophakic bullous keratopathy in the left eye. Given a history of long-term uncontrolled glaucoma with advanced disc cupping and poor visual potential, the patient underwent multiple palliative procedures, including, most recently, a PTK. Few years later she presented with a spontaneous late onset of slowly appearing corneal leak on fluorescein staining upon routine clinical examination. Corrected distance visual acuity was hand motion and intraocular pressure (IOP) was 40 mmHg in the affected eye. Serial anterior segment optical coherence tomography (AS-OCT) sections were obtained, which aided in understanding the current presentation and revealed distinctive multilayer corneal changes during the healing process. The patient was successfully managed with cyanoacrylate corneal gluing and ocular hypotensive medications, which halted the corneal leak. CONCLUSIONS We report a case of a rare finding of corneal fistula in an eye with multiple previous ocular surgeries, and provide an explanation of the possible etiopathogenesis. We also highlight the pivotal role of AS-OCT for evaluating such cases and stress the importance of early detection of similar subtle leaks in the setting of a formed anterior chamber, which can often be missed, carrying a risk of infection.


Assuntos
Córnea , Doenças da Córnea , Fístula , Lasers de Excimer , Ceratectomia Fotorrefrativa , Idoso , Feminino , Humanos , Córnea/patologia , Córnea/cirurgia , Lasers de Excimer/efeitos adversos , Lasers de Excimer/uso terapêutico , Ceratectomia Fotorrefrativa/efeitos adversos , Ceratectomia Fotorrefrativa/métodos , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Fístula/diagnóstico , Fístula/etiologia , Fístula/terapia , Doença Crônica , Doenças da Córnea/diagnóstico , Doenças da Córnea/etiologia , Doenças da Córnea/terapia , Oftalmopatias/cirurgia
11.
BMC Ophthalmol ; 23(1): 518, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38129776

RESUMO

BACKGROUND: To assess the safety and effectiveness of the exclusive use of 27-gauge instruments for all vitreoretinal diseases requiring vitrectomy. METHODS: In this retrospective study, 1020 consecutive surgeries were performed on 958 eyes of 848 patients using 27-gauge instruments from March 2017 to June 2021. Patients with a minimum follow-up of 3 months were included. Surgical case-mix, best-corrected visual acuity (BCVA), intraocular pressure (IOP), intra- and post-operative complications, and surgery times were recorded. RESULTS: The study patients were followed up for averagely 11 months. Of the 1020 vitrectomies, 958 were primary procedures. Of the 148 retinal detachment (RD) cases, 138 (93%) required a single vitrectomy. Primary macular hole closure was achieved in 143 of 145 (99%) cases. The average surgical times were 55 and 38 min for RD surgeries and for all other indications, respectively. BCVA improved significantly at the final visit (20/49) compared with the pre-operative visit (20/78) (p < 0.01). IOP was similar at the pre-operative (14.8mmHg) and final (14.3mmHg) visits. Complications recorded include transient hypotony in 39 eyes, iatrogenic retinal breaks in 2 eyes, and a vitreous bleed in 1 other eye. CONCLUSION: This study revealed that 27-gauge vitrectomy instruments can be used for a wide range of indications, with exclusive use in certain settings. The outcomes were similar to other gauges, including for rhegmatogenous retinal detachment, with minimal complications.


Assuntos
Oftalmopatias , Descolamento Retiniano , Perfurações Retinianas , Humanos , Descolamento Retiniano/cirurgia , Vitrectomia/métodos , Estudos Retrospectivos , Acuidade Visual , Perfurações Retinianas/cirurgia , Oftalmopatias/cirurgia , Resultado do Tratamento , Seguimentos
12.
Int Ophthalmol ; 43(12): 4585-4593, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37665493

RESUMO

PURPOSE: To evaluate the safety of yttrium-aluminum-garnet (YAG) laser vitreolysis for intraocular tissues. METHODS: Thirty-six New Zealand rabbits were divided as follows: Group 1000 (n = 12) treated with YAG laser of 1000 mJ (5 mJ × 200 shots), Group 2000 (n = 12) treated with YAG laser of 2000 mJ (5 mJ × 400 shots), Group 3000 (n = 12) treated with YAG laser of 3000 mJ (5 mJ × 600 shots). Either a single eye was chosen as the study eye in study groups while the other was untreated as the control group. Intraocular pressure (IOP), slit-lamp, optical coherence tomography (OCT), transmission electron microscopy (TEM), and inflammatory cytokines of aqueous humor (interleukin-1α (IL-1α), interleukin-1ß (IL-1ß), interleukin-8 (IL-8), and tumor necrosis factor-α (TNF-α)) were performed to examine the rabbits. RESULTS: There were no abnormalities in the study groups of IOP, slit-lamp, and OCT examinations. Group 3000 of TEM showed: neutrophils and mitochondrial swelling on day 1, and fibroblasts and neocollagen on day 14. No abnormalities were observed in Group 1000 and 2000 of TEM. Levels of IL-1α and TNF-α increased at 12 h and decreased to baseline on day 3. Levels of IL-1ß increased at 12 h and decreased to baseline on day 7. Levels of IL-8 increased on day 1 and decreased to baseline on day 3. CONCLUSION: YAG laser vitreolysis is safe when the distance is more than 2 mm from ablation point to the lens and the retina, and the total energy is less than 2000 mJ for one treatment procedure.


Assuntos
Oftalmopatias , Terapia a Laser , Lasers de Estado Sólido , Coelhos , Animais , Interleucina-8 , Fator de Necrose Tumoral alfa , Lasers de Estado Sólido/efeitos adversos , Oftalmopatias/cirurgia , Vitrectomia , Terapia a Laser/efeitos adversos , Terapia a Laser/métodos , Complicações Pós-Operatórias/cirurgia , Retina
13.
Medicina (Kaunas) ; 59(8)2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37629677

RESUMO

Ocular diseases can significantly impact vision and quality of life through pathophysiological alterations to the structure of the eye. The management of these conditions often involves a combination of pharmaceutical interventions, surgical procedures, and laser therapy. Laser technology has revolutionized many medical fields, including ophthalmology, offering precise and targeted treatment options that solve some of the unmet needs of other therapeutic strategies. Conventional laser techniques, while effective, can generate excessive thermal energy, leading to collateral tissue damage and potential side effects. Compared to conventional laser techniques, micropulse laser therapy delivers laser energy in a pulsed manner, minimizing collateral damage while effectively treating target tissues. The present paper highlights the advantages of micropulse laser therapy over conventional laser treatments, presents the implications of applying these strategies to some of the most prevalent ocular diseases, and highlights several types and mechanisms of micropulse lasers. Although micropulse laser therapy shows great potential in the management of ocular diseases, further research is needed to optimize treatment protocols, evaluate long-term efficacy, and explore its role in combination therapies.


Assuntos
Oftalmopatias , Terapia a Laser , Terapia com Luz de Baixa Intensidade , Humanos , Qualidade de Vida , Oftalmopatias/cirurgia , Gerenciamento Clínico
14.
Indian J Ophthalmol ; 71(8): 3119, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37530302

RESUMO

Background: The use of human amniotic membrane transplantation is rapidly increasing for the management of various ocular surface disorders. Despite its numerous advantages, amniotic membrane is not widely available due to the lack of awareness among ophthalmologists regarding its preparation and preservation techniques. Purpose: To provide an instructional video demonstrating the technique of harvesting, preparation, preservation of human amniotic membrane, and its uses in the management of ocular surface diseases. Synopsis: The amniotic membrane is the innermost layer of the human placenta. Properties of the amniotic membrane, like the presence of various growth factors, anti-inflammatory and anti-angiogenic factors, and its low immunogenicity, contribute to its ability to promote epithelial growth and differentiation with the reduction in fibrosis during healing. To harvest amniotic membrane, informed consent is obtained from a patient undergoing an elective caesarian section, and the donor is screened to exclude the risk of infections. Under sterile precautions, the amniotic membrane is separated from the chorion and washed free of blood clots. With the epithelial surface up, the amniotic membrane is spread uniformly without folds or tears on individually sterilized 0.22 µm nitrocellulose filter papers of the required sizes. The prepared filter paper with the adherent amniotic membrane is placed in freshly prepared Dulbecco's Modified Eagle's Medium and stored at -80°C. The amniotic membrane can be used for surgical procedures like symblepharon release, pterygium or dermoid excision, perforated ulcers, nonhealing epithelial defects, etc. Highlights: Instructional videos demonstrating the preparation and preservation of amniotic membrane are very sparse. This video clearly explains how any ophthalmologist can learn to prepare and preserve the human amniotic membrane and gives a glimpse of its properties, advantages, and scope of use. Video Link: https://youtu.be/8HfSjXUKoiY.


Assuntos
Oftalmopatias , Procedimentos de Cirurgia Plástica , Pterígio , Gravidez , Feminino , Humanos , Âmnio/transplante , Oftalmopatias/cirurgia , Túnica Conjuntiva/cirurgia , Pterígio/cirurgia
15.
Int Ophthalmol ; 43(10): 3587-3594, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37402010

RESUMO

PURPOSE: To demonstrate the methodology and efficacy of using scanning laser ophthalmoscopy (SLO) and dynamic optical coherence tomography (OCT) to identify and treat symptomatic vitreous floaters using yttrium-aluminum garnet laser vitreolysis (YLV). METHODS: This is a case series highlighted from a cross sectional retrospective study conducted at the Vitreous Retina Macula Specialists of Toronto. Forty eyes from thirty-five patients were treated with YLV between November 2018 and December 2020 for symptomatic floaters and imaged with SLO and dynamic OCT. Patients were re-treated with YLV if they reported ongoing significant vision symptoms during follow-up which correlated to visible opacities on exam and or imaging. Three cases will be highlighted to present the practical applications of SLO and dynamic OCT imaging for YLV treatment. RESULTS: Forty treated eyes were enrolled in this study, with twenty-six eyes (65%) requiring at least one repeat YLV treatment following the first treatment due to ongoing symptomatic floaters. Following the first YLV, there was a significant improvement in overall mean best corrected visual acuity compared to before treatment (0.11 ± 0.20 LogMAR units vs. 0.14 ± 0.20 LogMAR units, p = 0.02 (paired t test)). Case 1 demonstrates a dense, solitary vitreous opacity that has been localized with dynamic OCT imaging to track its movements and retinal shadowing with the patient's eye movements. Case 2 shows the utility of adjusting the fixation target to monitor the movement of vitreous opacities in real-time. Case 3 exhibits an association between decreased symptom burden and vitreous opacity density after YLV. CONCLUSION: Image-guided YLV facilitates the localization and confirmation of vitreous opacities. SLO and dynamic OCT of the vitreous can provide a real-time evaluation of floater size, movement, and morphology, to help clinicians target treatment and monitoring of symptomatic floaters.


Assuntos
Oftalmopatias , Vitrectomia , Humanos , Estudos Retrospectivos , Estudos Transversais , Vitrectomia/métodos , Oftalmopatias/diagnóstico , Oftalmopatias/cirurgia , Corpo Vítreo/diagnóstico por imagem , Corpo Vítreo/cirurgia , Transtornos da Visão , Tomografia de Coerência Óptica
16.
J Cataract Refract Surg ; 49(9): 976-981, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37343278

RESUMO

PURPOSE: To compare peak surge and surge duration time after occlusion break, incision leakage compensation, and passive vacuum for 2 phacoemulsification systems. SETTING: Carl Zeiss Meditec AG, Oberkochen, Germany. DESIGN: Laboratory study. METHODS: A spring-eye model was used to test Alcon Centurion Vision and Zeiss Quatera 700 systems. Peak surge and duration was measured after an occlusion break. Quatera tested in flow and vacuum priority modes. Vacuum limits ranged from 300 to 700 mm Hg with intraocular pressure (IOP) set at 30 mm Hg, 55 mm Hg, and 80 mm Hg. IOP vs incision leakage rates of 0 to 15 cc/min and passive vacuum were measured. RESULTS: At 30 mm Hg IOP set point and vacuum limits ranging 300 to 700 mm Hg, the surge duration time after occlusion break ranged 419 to 1740 milliseconds (ms) for Centurion, 284 to 408 ms for Quatera in the flow mode, and 282 to 354 ms for Quatera in the vacuum mode. At 55 mm Hg, values ranged 268 to 1590 ms for Centurion, 258 to 471 ms for Quatera in the flow mode, and 239 to 284 ms for Quatera in the vacuum mode. At 80 mm Hg, values were 243 to 1520 ms for Centurion, 238 to 314 ms for Quatera in the flow mode, and 221 to 279 ms in the vacuum mode. Centurion exhibited slightly less peak surge than the Quatera. At 55 mm Hg: incision leakage rates 0 to 15 cc/min, Quatera held the IOP within ±2 mm Hg of target; Centurion was unable to hold IOP target allowing a 11.7 mm Hg decrease with 32% higher passive vacuum. CONCLUSIONS: Quatera demonstrated slightly higher surge peak values and notably shorter surge duration times after occlusion break than Centurion. Quatera demonstrated better incision leakage compensation and lower passive vacuum than Centurion.


Assuntos
Oftalmopatias , Facoemulsificação , Humanos , Pressão Intraocular , Câmara Anterior/cirurgia , Vácuo , Tonometria Ocular , Oftalmopatias/cirurgia
17.
J Plast Reconstr Aesthet Surg ; 82: 170-175, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37182248

RESUMO

OBJECTIVE: End-stage ocular diseases usually end up with atrophic bulbi or phthisis bulbi leading to orbital volume loss which needs to be addressed. We studied the use of autologous fat for volume augmentation of the orbit because it is minimally invasive and allows early rehabilitation with the use of an artificial eye. DESIGN: It was a prospective, interventional study. METHODS: A total of 14 eyes of 14 patients with atrophic bulbi with shrinkage or phthisis bulbi with no perception of light (PL) and aged older than 18 years were included for the study purpose. Painful or inflamed eyes or suspected intraocular tumors were excluded. An autologous fat graft was obtained from the lower abdomen or buttocks and injected into the retrobulbar space using a 20-gauge cannula after adequate peribulbar anesthesia. Outcomes measures were patient satisfaction, change in Hertel's exophthalmometry, vertical and horizontal palpebral aperture, and socket volume. RESULTS: Hertel exophthalmometry showed a significant improvement both with and without an artificial eye from 14.92 ± 2.3 mm to 16.71 ± 1.94 mm (p-value 0.003 without an artificial eye). The vertical palpebral aperture also showed a significant improvement from 5 ± 1.70 mm to 6.71 ± 1.58 mm (p-value < 0.001). There was a significant reduction in the socket volume from 1.22 ml to 0.39 ml (p-value < 0.001). No local or donor site complications were seen. CONCLUSIONS: Autologous fat transfer is a minimally invasive, safe, and effective procedure for orbital volume augmentation in small, nonseeing eyes. The short-term outcome of our study was good in most patients and can be considered for such patients.


Assuntos
Tecido Adiposo , Órbita , Procedimentos de Cirurgia Plástica , Humanos , Olho Artificial , Órbita/cirurgia , Estudos Prospectivos , Estudos Retrospectivos , Oftalmopatias/cirurgia , Adulto , Tecido Adiposo/transplante
19.
Acta Med Port ; 36(10): 683-686, 2023 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-37080196

RESUMO

A 17-year-old male was taken to the emergency department for decreased left visual acuity and floaters beginning that same day. There was a history of exposure to pulmonary tuberculosis five years before (mother as index case) followed by a four-month period of isoniazid prophylaxis. The ophthalmic examination showed posterior and intermediate uveitis in the left eye. Laboratory tests were normal; IgG for herpes simplex 1 was positive and both the varicella-zoster virus and remaining serologic tests were negative. Chest radiography was normal. Two weeks later, an epiretinal membrane with risk of tractional retinal detachment was observed. The Mantoux tuberculin skin test showed an induration of 15 mm and the IGRA test was positive. Sputum and vitreous humor samples were collected. Quadruple therapy and prednisolone were started. Ten days later, a posterior vitreous detachment with underlying vitreous hematoma was observed. Posterior vitrectomy and peripheral endolaser were performed without complications. One month later, the microbiological results became available, with the identification of Mycobacterium tuberculosis. Corticosteroids were weaned progressively. Antituberculous drugs were maintained for six months. The patient made a full recovery.


Assuntos
Oftalmopatias , Mycobacterium tuberculosis , Tuberculose Ocular , Masculino , Humanos , Criança , Adolescente , Tuberculose Ocular/diagnóstico , Tuberculose Ocular/tratamento farmacológico , Tuberculose Ocular/cirurgia , Corpo Vítreo/microbiologia , Corpo Vítreo/cirurgia , Vitrectomia , Oftalmopatias/cirurgia
20.
BMC Ophthalmol ; 23(1): 130, 2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-36997919

RESUMO

BACKGROUND: Ocular trauma is complex and varied, and some occult intraocular foreign bodies (IOFBs) can lead to uncommon symptoms and signs. We report a case of rhegmatogenous retinal detachment (no obvious wound, no pain, no intraocular infection or other symptoms) caused by an occult intraocular aluminium foreign body, which could have been easily missed. CASE PRESENTATION: A 42-year-old male presented to the outpatient department of our hospital complaining of fluttering black dots and decreased vision in his left eye that began 3 months earlier. He was diagnosed with "floaters" at a community hospital. He denied a history of ocular trauma or previous surgery. The cornea and lens of the left eye were clear. A small patch of pigmentation was noted in the temporal sclera. Fundoscopy revealed macula-off retinal detachment. After mydriasis, elliptical holes were seen in the peripheral retina at 2:30, and a suspicious hyperreflective strip was found under the anterior lip of the retina by Goldmann three-mirror contact lens examination; the strip was confirmed to be an IOFB by orbital CT. The IOFB was removed through pars plana vitrectomy without any complications. CONCLUSION: Unlike iron and copper IOFBs, aluminium IOFBs are more inert and more likely to be missed. For people with special occupations (construction workers, mechanics, etc.), when abnormal pigmentation of the sclera is found, the possibility of foreign bodies in the eye should be considered. In the process of disease diagnosis and treatment, it is necessary to ask for a detailed history, including occupation history and practice, and perform careful physical and targeted examinations. Such comprehensive analysis regarding the above information will minimize the chance of missed diagnosis.Awareness of occult IOFB in high risk occupations and prompt referral to a retinal surgeon is of outmost importance.


Assuntos
Oftalmopatias , Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Descolamento Retiniano , Masculino , Humanos , Adulto , Descolamento Retiniano/diagnóstico , Descolamento Retiniano/etiologia , Descolamento Retiniano/cirurgia , Alumínio , Ferimentos Oculares Penetrantes/complicações , Ferimentos Oculares Penetrantes/diagnóstico , Oftalmopatias/cirurgia , Corpos Estranhos no Olho/complicações , Corpos Estranhos no Olho/diagnóstico , Vitrectomia/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...