Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.291
Filtrar
1.
J Mater Sci Mater Med ; 35(1): 35, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38900360

RESUMO

Bioabsorbable sutures can improve the medical functions of existing non-absorbable sutures, and may produce new medical effects, and are expected to become a new generation of medical degradable materials. In this study, the cytocompatibility of triclosan coated polyglactin910 sutures (CTS-PLGA910) was analyzed and different concentrations of sutures were prepared. The effects of sutures on the cytotoxicity and cell proliferation of HUVEC were studied by CCK-8 assay. The hemolysis, total antioxidant capacity (T-AOC) activity and nitric oxide (NO) content were investigated to improve the blood compatibility of sutures. The results showed that the hemolysis rate of CTS-PLGA910 was less than 5%. After treatment on HUVEC cells for 48 and 72 h, there was no significant change in NO content in CTS-PLGA910 groups compared with the control group, while T-AOC activity and antioxidant capacity were significantly increased in medium and high dose groups. In summary, the blood compatibility and cell compatibility were significantly improved, which provided a basis for the clinical application of sutures in the future.


Assuntos
Proliferação de Células , Materiais Revestidos Biocompatíveis , Células Endoteliais da Veia Umbilical Humana , Teste de Materiais , Poliglactina 910 , Suturas , Triclosan , Humanos , Triclosan/farmacologia , Triclosan/química , Poliglactina 910/química , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Proliferação de Células/efeitos dos fármacos , Hemólise/efeitos dos fármacos , Antioxidantes/farmacologia , Antioxidantes/química , Materiais Biocompatíveis/química , Óxido Nítrico/metabolismo , Sobrevivência Celular/efeitos dos fármacos
2.
J Obstet Gynaecol ; 44(1): 2370973, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38934494

RESUMO

This study aimed to compare the tissue damage caused by barbed sutures and conventional sutures using scanning electron microscopy (SEM). Porcine myocardium was incised and sutured using different thread types: barbed suture, (STRATAFIX® Spiral PDS PLUS) and conventional sutures, (VICRYL® and PDS Plus®). Needle hole shapes were examined at magnifications of 30×-100×. VICRYL® suture damaged the tissue and created large gaps around the needle holes. The tissue around the needle holes was smoother and less damaged in the single suture ligations with PDS®; however, a large gap had formed. In the continuous suture with STRATAFIX®, the tissue around the needle holes was significantly smoother and minimally damaged, with no noticeable gaps around the needle holes. Barbed sutures reduced the load on needle holes and minimised tissue damage owing to the dispersion of traction forces by the barbs compared with conventional sutures.


Assuntos
Microscopia Eletrônica de Varredura , Técnicas de Sutura , Suturas , Animais , Suturas/efeitos adversos , Suínos , Técnicas de Sutura/efeitos adversos , Modelos Animais , Poliglactina 910/efeitos adversos , Miocárdio/patologia , Miocárdio/ultraestrutura
3.
Otolaryngol Pol ; 78(2): 23-28, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38623859

RESUMO

<b><br>Introduction:</b> Septorhinoplasty aims to enhance nasal function and appearance. This common but complex procedure has demonstrated advancements with both open and endonasal approaches. The selection of sutures can impact patient comfort and scar outcomes, presenting both advantages and disadvantages.</br> <b><br>Aim:</b> This study was conducted to compare the cosmetic outcomes of the use of absorbable polyglactin 910 (PG) (Vicryl Rapide 5/0; Ethicon Inc.) and nonabsorbable polypropylene (PP) (Prolene 5/0; Ethicon Inc.) in open septorhinoplasty in terms of surgical scarring.</br> <b><br>Methods:</b> The sample of this prospective, randomized, single-blind study consisted of 42 patients who underwent open septorhinoplasty. The patients were randomized into the vicryl rapide (n = 16) and prolene (n = 26) suture groups. The groups were comparatively evaluated by two surgeons in terms of surgical scarring, pigmentation, level difference, indentation, and general appearance based on patient photographs taken in the 2nd week, 6th weeks and 12th week post-op.</br> <b><br>Results:</b> The mean age of the vicryl rapide and prolene groups was 26.9 5.7 years and 24.6 3.9 years, respectively. There was no significant difference between the groups in any of the parameters investigated within the scope of the study in postoperative week 2, 6, and 12 (P > 0.05). On the other hand, intragroup analyses revealed that suture scar significantly decreased in the vicryl rapide group in the 6th and 12th weeks compared to the 2nd week (P < 0.05), while no significant difference was observed in the prolene group in the suture scars in week 6 and 12 compared to week 2 (P > 0.05).</br> <b><br>Conclusions:</b> Inverted V trans-columellar incisions sutured with rapidly absorbable suture material resulted in significantly less suture discomfort and did not significantly increase the risk of postoperative infection compared to nonabsorbable suture material. However, there was no significant difference between the two suture materials in terms of scar appearance.</br>.


Assuntos
Cicatriz , Poliglactina 910 , Humanos , Adulto , Polipropilenos , Estudos Prospectivos , Método Simples-Cego , Suturas
4.
J Evid Based Dent Pract ; 24(1): 101952, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38448126

RESUMO

BACKGROUND: In order to achieve uneventful and rapid healing of the tissues, a suture material should be biocompatible, easy to handle, sterile, and have good and uniform tensile strength. Hence, in the present study, characterization of the suture materials was done through a novel green chemistry approach using Punica granatum seed extract. MATERIALS AND METHODS: Ethanolic extract of P. granatum seed was prepared by dissolving 25 g of P. granatum seed powder with 100 mL of ethanol. The obtained extract was coated in silk and Vicryl suture material and was tested for its surface morphology (SEM), tensile strength, anti-microbial activity, biocompatibility, and wound healing potential. RESULTS: Silk and Vicryl sutures coated with P. granatum seed extract showed the uniform coating and deposition of extract with sustaining integrity. Vicryl suture coated with the extract had good tensile strength and antimicrobial activity. The in vitro scratch assay and biocompatibility test showed that the P. granatum seed extract had excellent wound healing potential and can be used without any effect on the viability of the normal cells. CONCLUSION: Within the limitations of the study it can be concluded that P. granatum seed extract coated Vicryl sutures had good tensile strength and anti-microbial activity. P. granatum seed extract also showed excellent biocompatibility and wound healing potential.


Assuntos
Punica granatum , Humanos , Projetos Piloto , Poliglactina 910 , Suturas , Seda , Etanol , Extratos Vegetais/farmacologia
5.
Molecules ; 29(4)2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38398518

RESUMO

To develop an orthopedic scaffold that could overcome the limitations of implants used in clinics, we designed poly(ester-urethane) foams and compared their properties with those of a commercial gold standard. A degradable poly(ester-urethane) was synthetized by polyaddition between a diisocyanate poly(ε-caprolactone) prepolymer (PCL di-NCO, Mn = 2400 g·mol-1) and poly(lactic-co-glycolic acid) diol (PLGA, Mn = 2200 g·mol-1) acting as a chain extender. The resulting high-molecular-weight poly(ester-urethane) (PEU, Mn = 87,000 g·mol-1) was obtained and thoroughly characterized by NMR, FTIR and SEC-MALS. The porous scaffolds were then processed using the solvent casting (SC)/particle leaching (PL) method with different NaCl crystal concentrations. The morphology, pore size and porosity of the foams were evaluated using SEM, showing interconnected pores with a uniform size of around 150 µm. The mechanical properties of the scaffolds are close to those of the human meniscus (Ey = 0.5~1 MPa). Their degradation under accelerated conditions confirms that incorporating PLGA into the scaffolds greatly accelerates their degradation rate compared to the gold-standard implant. Finally, a cytotoxicity study confirmed the absence of the cytotoxicity of the PEU, with a 90% viability of the L929 cells. These results suggest that degradable porous PLGA/PCL poly(ester-urethane) has potential in the development of meniscal implants.


Assuntos
Materiais Biocompatíveis , Caproatos , Lactonas , Poliuretanos , Humanos , Poliuretanos/química , Materiais Biocompatíveis/química , Poliglactina 910 , Porosidade , Poliésteres/química , Ésteres , Alicerces Teciduais/química , Engenharia Tecidual/métodos
6.
Afr J Paediatr Surg ; 21(1): 56-57, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38259021

RESUMO

BACKGROUND: Reduction and stabilisation of fractures at the earliest is valuable in the paediatric age groups. This novel technique focuses on stabilisation of the fracture fragments using vicryl, which has an added advantage to conventional plating and wiring. This study aimed on a novel cost-effective technique of stabilising the paediatric mandibular fracture using 2-0 resorbable polyglactin 910 suture with minimal trauma to tooth buds and bone and adequate stability. TECHNIQUE: After raising a full-thickness mucoperiosteal flap, the fracture segments are identified and reduced. 1.6mm drill bit is used to make holes through the buccal cortex on either side of the fractured segment in an anteroposterior direction. The patency of holes is checked by passing a long 26-gauge wire. The proximal end of the wire is bent into a loop, a 2-0 resorbable polyglactin suture (vicryl) is passed through this loop and the loop is pressed in place to lock the suture. The wire with the attached suture is pulled through the distal end. Once the suture is secure in place, the 26G wire is cut, and the two ends of sutures are knotted and stabilised. The mucoperiosteal flap is then closed. CONCLUSION: A novel method of stabilisation of paediatric fracture without hampering the tooth and jaw growth, especially in the financially unstable population. 2-0 polyglactin 910 suture is cost-effective, $2 US, compared to resorbable plates costing about $150 US, and easily available. Polyglactin 910 takes 40-60 days for resorption, and half-life tensile strength is 2 weeks; thus, it gives adequate stability and time for callus formation and does not damage the tooth buds or bone by cutting through them.


Assuntos
Fraturas Mandibulares , Humanos , Criança , Poliglactina 910 , Procedimentos Neurocirúrgicos , Fixação Interna de Fraturas
7.
Medicina (Kaunas) ; 60(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38256351

RESUMO

Objective: To compare the vaginal cuff dehiscence (VCD) rates using Vicryl (Poliglactyn 910) and Polydioxanone (PDS) in patients who underwent laparoscopic hysterectomy. Materials and methods: A retrospective, monocentric study was conducted, including all patients undergoing laparoscopic hysterectomy at the Department of Obstetrics and Gynaecology, Azienda di Rilievo Nazionale e di Alta Specializzazione (ARNAS) Garibaldi Nesima, Catania, between January 2014 and December 2021. Patients underwent hysterectomy for benign gynecologic pathologies (endometriosis, leiomyomas, or benign pelvic pathologies) or malignant gynecologic pathologies (endometrium cancer, complex endometrial hyperplasia, ovarian cancer, cervix cancer, or uterine carcinosarcoma). The Z-score calculation was performed to find eventual statistically significant differences between the two populations regarding VCD rates. Results: Laparoscopic vaginal cuff closure was performed, with Vicryl sutures in 202 patients and PDS sutures in 184 women. Demographic and baseline characteristics were not significantly different in the two groups. VCD occurred in three patients in the Vicryl group and did not occur in the PDS group. The three cases of VCD were precipitated by intercourses that occurred within 90 days of surgery. However, there was not a significant statistical difference between the two groups regarding VCD (p = 0.09). Conclusions: Vicryl and PDS sutures seem to be similar for vaginal cuff closure in laparoscopic hysterectomy. The VCD rate was low, and the observed differences between the Vicryl and PDS groups did not reach statistical significance. Further research through prospective studies is essential.


Assuntos
Laparoscopia , Polidioxanona , Gravidez , Feminino , Humanos , Polidioxanona/uso terapêutico , Poliglactina 910/uso terapêutico , Estudos Prospectivos , Estudos Retrospectivos , Laparoscopia/efeitos adversos , Histerectomia/efeitos adversos
8.
Int J Gynaecol Obstet ; 166(1): 389-396, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38243632

RESUMO

OBJECTIVES: To compare the tensile strength of fast absorbable Polyglactin 910 suture material when impregnated with various agents for local anesthesia and to investigate whether the presence of ethanol in Xylocaine spray could explain a potential reduction in tensile strength after use of Xylocaine spray. METHODS: In all, 120 suture samples of Polyglactin 910 were divided into four groups of 30. These four groups were randomly impregnated with isotonic sodium chloride, isotonic sodium chloride plus Xylocaine spray, isotonic sodium chloride plus Xylocaine gel, or isotonic sodium chloride plus ethanol. After impregnation, the sutures were stored in sealed glass tubes in a heating cabinet at 37°C for 72 h. Thereafter, the tensile strength of these 120 samples was assessed by a universal tensile testing machine. The maximal force needed to break the suture material was recorded in newtons (N). RESULTS: Fast absorbable Polyglactin 910 suture material impregnated with Xylocaine spray or ethanol showed weakened tensile strength (mean values 11.40 and 11.86 N, respectively), whereas the specimens impregnated with Xylocaine gel or sodium chloride retained their tensile strength better (mean values 13.81 and 13.28 N, respectively; mean difference between Xylocaine gel and Xylocaine spray -2.41 N, P < 0.001). CONCLUSION: In this in vitro experiment, ethanol and Xylocaine spray weakened the tensile strength of fast absorbable Polyglactin 910 sutures. Use of Xylocaine spray, which contains ethanol, for local anesthesia might lead to early breakdown of the suture material and wound rupture. The authors suggest caution when using Xylocaine spray in combination with fast absorbable Polyglactin 910 suture.


Assuntos
Anestésicos Locais , Etanol , Lidocaína , Poliglactina 910 , Suturas , Resistência à Tração , Anestésicos Locais/farmacologia , Anestésicos Locais/administração & dosagem , Lidocaína/farmacologia , Etanol/farmacologia , Teste de Materiais , Humanos , Cloreto de Sódio
9.
Int Wound J ; 21(1): e14387, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37705324

RESUMO

Surgical site infection (SSI) is a common cause of post-operative morbidity. According to the latest report announced by CDC, the SSI accounts for 20% of healthcare-associated infection with a high risk of mortality up to twofold to 11-fold increase with high economic burden for the prolonged hospital stay. Port site infection (PSI) is a subgroup of SSI occurring at the ports of laparoscopy. We tried to determine the efficacy of polyglactin 910 suture coated with triclosan in lowering the rate of PSI in some of the clean-contaminated wound surgeries. This study included 480 individuals eligible for laparoscopic cholecystectomy, appendicectomy or sleeve operations. Polyglactin 910 sutures coated with triclosan were used in one port site incision while polyglactin 910 sutures were used in the other port sites incisions. In patients who underwent laparoscopic cholecystectomy and appendicectomy, the incidence of PSI was significantly lower in the triclosan-coated sutures. In sleeve gastrectomy patients, although a lower number of triclosan-coated sutures developed PSI, there was no statistically significant difference between triclosan and non-triclosan-coated sutures. This study showed that using sutures coated with antiseptics like triclosan has clinical benefits to prevent SSIs in most of the laparoscopic surgeries.


Assuntos
Anti-Infecciosos Locais , Colecistectomia Laparoscópica , Laparoscopia , Triclosan , Humanos , Triclosan/uso terapêutico , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/prevenção & controle , Infecção da Ferida Cirúrgica/etiologia , Colecistectomia Laparoscópica/efeitos adversos , Incidência , Poliglactina 910 , Anti-Infecciosos Locais/uso terapêutico , Laparoscopia/efeitos adversos , Suturas/efeitos adversos , Gastrectomia/efeitos adversos
10.
J Craniofac Surg ; 35(1): e32-e34, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37702519

RESUMO

Polyglactin 910 (Vicryl) and polypropylene (Prolene) are common suture materials used in ophthalmic surgical procedures. However, there are limited studies assessing tissue reactions to different sutures in eyelid areas. In this study, these suture materials were used subcutaneously in 10 lateral canthi of 5 pigs. Clinical reactive score (CRS) was assessed 14 days and 60 days after surgery. On histology, subcutaneous tissue reactions were assessed by the presence of different inflammatory cells, and the aggregate tissue irritation score was calculated. CRS and the histology score did not differ between these sutures. None of the suture materials used were superior for use in the lateral canthi of pig eyes. Therefore, we recommend both of these sutures for use in the subcutaneous tissue of the eyelid area in animal experiments or clinical practice.


Assuntos
Aparelho Lacrimal , Projetos de Pesquisa , Suínos , Animais , Suturas , Poliglactina 910 , Pálpebras/cirurgia , Técnicas de Sutura
11.
J Biomed Mater Res B Appl Biomater ; 112(1): e35327, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37732480

RESUMO

Micelles have been extensively used in biomedicine as potential carriers of hydrophobic fluorescent dyes. Their small diameters can potentially enable them to evade recognition by the reticuloendothelial system, resulting in prolonged circulation. Nevertheless, their lack of stability in physiological environments limits the imaging utility of micelles. In particular, when a dye sensitive to water, such as IR-1061, is encapsulated in the micelle core, the destabilized structure leads to interactions between water and dye, degrading the fluorescence. In this study, we investigated a method to improve micelle stability utilizing the electrical effect of gadolinium (Gd3+ ) and tetraazacyclododecane tetraacetic acid (DOTA), introduced into the micelles. Three micellar structures, one containing a poly(lactic-co-glycolic acid)-block-poly(ethylene glycol) (PLGA-b-PEG) block copolymer, and two other structures, including PLGA-b-PEG with DOTA or Gd-DOTA introduced at the boundary of PLGA and PEG, were prepared with IR-1061 in the core. Structures that contained DOTA at the border of the PLGA core and PEG shell exhibited much higher fluorescence intensity than probes without DOTA. With Gd3+ ions at the DOTA center, fluorescence stability was enhanced remarkably in physiological environments. Most interesting is the finding that fluorescence is enhanced with increased Gd-DOTA concentrations. In conclusion, we found that overall fluorescence and stability are improved by introducing Gd-DOTA at the boundary of the PLGA core and PEG shell. Improving micelle stability is crucial for further biomedical applications of micellar probes such as bimodal fluorescence and magnetic resonance imaging.


Assuntos
Boratos , Compostos Heterocíclicos , Lactatos , Micelas , Compostos Organometálicos , Polietilenoglicóis , Piranos , Fluorescência , Polietilenoglicóis/química , Poliglactina 910/química , Água/química
12.
Drug Deliv Transl Res ; 14(3): 696-704, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38038895

RESUMO

Remote loading microencapsulation of peptides into polymer microspheres without organic solvent represents a promising alternative to develop long-acting release depots relative to conventional encapsulation methods. Here, we formulated drug-free microspheres from two kinds of uncapped poly(lactide-co-glycolides) (PLGAs), i.e., ring-opening polymerized Expansorb® DLG 50-2A (50/50, 11.2 kDa) and Expansorb® DLG 75-2A (75/25, 9.0 kDa), and evaluated their potential capacity to remote-load and control the release of two model peptides, leuprolide and octreotide. Degradation and erosion kinetics, release mechanism, and storage stability was also assessed. As control formulations, peptide was loaded in the same PLGA 75/25 polymer by the conventional double emulsion-solvent evaporation method (W/O/W) and remote loaded in polycondensation poly(lactic-co-glycolic acid) 75/25 (Wako 7515, 14.3 kDa). Loading content of 6.7%-8.9% w/w (~ 67%-89% encapsulation efficiency (EE)) was attained for octreotide, and that of 9.5% w/w loading (~ 95% EE) was observed for leuprolide, by the remote loading paradigm. Octreotide and leuprolide were both slowly and continuously released in vitro from the remote-loaded Expansorb® DLG 75-2A MPs for over 56 days, which was highly similar to that observed from traditionally-loaded formulations by W/O/W (8.8% loading, 52.8% EE). The faster release kinetics was observed for the faster degrading PLGA 50/50 remote-loaded Expansorb® DLG 50-2A MPs relative to microspheres from the PLGA 75/25 Expansorb® DLG 75-2A. Despite slight differences in degradation kinetics, the release mechanism of octreotide from the Expansorb® microspheres, whether remote loaded or by W/O/W, was identical as determined by release vs. mass loss curves. Octreotide acylation was also minimal (< ~ 10%) for this polymer. Finally, drug-free Expansorb® DLG 75-2A MPs displayed excellent storage stability over 3 months. Overall, this work offers support for the use of ring-opening Expansorb® PLGA-based microspheres to remote load peptides to create simple and effective long-acting release depots.


Assuntos
Octreotida , Ácido Poliglicólico , Ácido Poliglicólico/química , Octreotida/química , Poliglactina 910 , Ácido Láctico/química , Preparações de Ação Retardada , Leuprolida , Microesferas , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Solventes , Tamanho da Partícula
13.
J Obstet Gynaecol Can ; 46(1): 102191, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37595945

RESUMO

OBJECTIVES: Surgical site infections (SSI) are common causes of postoperative morbidity at cesarean delivery (CD). The objective of this study was to compare the risk of SSI and other wound complications associated with different suture materials for subcuticular skin closure at CD. DATA SOURCES: We searched Cochrane Library, MEDLINE, Embase, and Clinicaltrials.gov from inception to June 3, 2021, and limited our search to English, peer-reviewed, randomized controlled trials and cohort studies. STUDY SELECTION: Of 1541 titles identified, 4 studies met the selection criteria and were included. Studies were included if the population was pregnant individuals undergoing transverse incision primary or repeat, elective or emergent CD with subcuticular skin closure, and if outcomes related to SSI, wound seroma, hematoma, or dehiscence were reported. We completed the assessment using Covidence review management software. DATA EXTRACTION AND SYNTHESIS: Two authors independently reviewed studies and assessed the risk of bias using the Cochrane 'Risk of bias' tool for randomized trials (RoB 2.0) and the Cochrane Risk of Bias in Non-Randomized Studies-of Interventions (ROBINS-I) tools for cohort studies. We compared SSI risk and secondary outcomes of hematoma, seroma, and dehiscence between skin closure with monofilament (poliglecaprone 25 or polypropylene) versus multifilament (polyglactin 910) sutures using a fixed-effects meta-analysis. Statistical heterogeneity was estimated using the I2 statistic. Monofilament sutures were associated with a reduced risk of SSI (RR = 0.71, 95% CI 0.52-0.98, I2 = 0%) compared to multifilament sutures. There was no difference in the risk of secondary outcomes. CONCLUSION: Monofilament suture for subcuticular skin closure at CD was associated with decreased risk of SSI compared to multifilament suture.


Assuntos
Seroma , Deiscência da Ferida Operatória , Feminino , Gravidez , Humanos , Deiscência da Ferida Operatória/epidemiologia , Deiscência da Ferida Operatória/etiologia , Seroma/epidemiologia , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/prevenção & controle , Poliglactina 910 , Suturas/efeitos adversos , Hematoma/epidemiologia , Técnicas de Sutura/efeitos adversos
14.
Reprod Sci ; 31(1): 162-172, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37674005

RESUMO

The purpose of this animal study was to verify the effect of suturing on graft function in ovarian tissue transplantation. Ovaries from 2-week-old rats were transplanted orthotopically into the ovaries of 8-week-old female Wistar rats. The various transplantation methods used were insertion into the ovarian bursa without suturing (group A: control), suturing with a single 6-0 Vicryl stitch (group B: 6-0*1), suturing with a single 10-0 Vicryl stitch (group C: 10-0*1), and suturing with three 10-0 Vicryl stitches (group D: 10-0*3). Two weeks after transplantation, the transplanted ovaries were evaluated histologically and for gene expression. Engraftment rates of the donor ovaries 14 days after transplantation were 62.5%, 100%, 91.7%, and 100% in groups A, B, C, and D, respectively, significantly lower in group A than in the other groups. In terms of gene expression, TNFα levels were significantly higher in group D, and GDF9 and follicle-stimulating hormone receptor (FSHR) levels were significantly lower in group D than in groups A and B. The number of primordial follicles evaluated by HE staining was significantly lower in groups B, C, and D than in group A. Compared to orthotopic transplantation without sutures, direct suturing to the host improved the engraftment rate, although increasing the number of sutures increased inflammatory marker levels and decreased the number of primordial follicles. We believe that it is important to perform ovarian tissue transplantation using optimal suture diameter for good adhesion, but with a minimum number of sutures to preserve ovarian function.


Assuntos
Ovário , Poliglactina 910 , Ratos , Feminino , Animais , Poliglactina 910/metabolismo , Poliglactina 910/farmacologia , Ratos Wistar , Folículo Ovariano/metabolismo , Suturas
15.
Eye (Lond) ; 38(4): 752-756, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37857715

RESUMO

BACKGROUND/OBJECTIVES: To determine whether the success and complication rates of the Lateral Tarsal Strip (LTS) Procedure, when treating involutional ectropion/entropion, is influenced by the use of suture when attaching the tarsal strip to the periosteum. SUBJECTS/METHODS: Multi-centre retrospective comparative study of re-operation and complication rates (Recurrence, Dehiscence, Suture Infection, Granuloma, Haemorrhage, Residual-Lid Laxity, Suture Extrusion and Repeat Procedure) in LTS, between 01/01/2017 and 01/01/2022 who met the inclusion/exclusion criteria, for involutional ectropion/entropion using an absorbable polyglactin (vicryl) and non-absorbable polypropylene suture (prolene). RESULTS: 1079 operations in 891 patients (36% female, average age 81.4 years) were performed with an average follow-up of 1.785 years. 588 operations in 475 patients were performed using prolene whilst 491 procedures in 416 patients were performed using vicryl sutures. Of these, 61% were performed by a consultant surgeon in the prolene group compared to 49.7% in the vicryl group. Overall complication rates between prolene and vicryl were 24.7% and 29.7% (p = 0.061) respectively. Higher complication rates for post-operative residual lid laxity, granuloma and suture infection were greater in the vicryl group versus prolene (2.65% and 0.51% p = 0.004, 2.24% and 0.68% p = 0.03, 1.83% and 0.17% p = 0.007 respectively). Non-significant results for dehiscence or repeat procedures (2.24% and 2.21% p = 0.974, 6.72% and 9.01% p = 0.166 respectively). CONCLUSIONS: Both sutures are effective for the correction of involutional ectropion/entropion with LTS. Dehiscence and redo rates were not statistically significant. Nevertheless, the use of vicryl suture was found to be associated with a higher complication rate for: post-operative residual lid laxity, granuloma and suture infection.


Assuntos
Ectrópio , Entrópio , Humanos , Feminino , Idoso de 80 Anos ou mais , Masculino , Pálpebras/cirurgia , Ectrópio/cirurgia , Entrópio/cirurgia , Polipropilenos , Estudos Retrospectivos , Poliglactina 910 , Técnicas de Sutura , Suturas , Granuloma/cirurgia
16.
J Mater Chem B ; 12(2): 508-524, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38108579

RESUMO

Poly(lactide-co-glycolide) (PLGA) and calcium sulfate composites are promising biodegradable biomaterials but are still challenging to use in people with high levels of blood glucose or diabetes. To date, the influence of glucose on their degradation has not yet been elucidated and thus calls for more research attention. Herein, a novel calcium sulfate whisker with L-arginine was used to effectively tune its crystal morphology and was employed as a reinforced phase to construct the PLGA-based composite scaffolds (ArgCSH/PLGA) with a sleeve porous structure. ArgCSH/PLGA showed excellent elastic modulus and strength in the compression and bending models. Moreover, an in vitro immersion test showed that ArgCSH/PLGA possessed degradation and redeposition behaviors sensitive to glucose concentration, and the adsorbed Arg played a crucial role in the degradation process. The subsequent cell functional evaluation showed that ArgCSH could effectively protect cells from damage caused by AGEs and promote osteogenic differentiation. The corresponding degradation products of ArgCSH/PLGA displayed the ability to regulate osteoblast bone differentiation and accelerate matrix mineralization. These findings provide new insights into the interaction between biomaterials and the physiological environment, which may be useful in expanding the targeted choice of efficient bone graft biodegradable materials for diabetic osteoporosis.


Assuntos
Osteogênese , Poliglactina 910 , Humanos , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Poliglactina 910/química , Sulfato de Cálcio , Ácido Poliglicólico/química , Ácido Láctico/química , Arginina/farmacologia , Materiais Biocompatíveis/farmacologia , Materiais Biocompatíveis/química
17.
Biomacromolecules ; 25(1): 67-76, 2024 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-38135465

RESUMO

Fat grafting, a key regenerative medicine technique, often requires repeat procedures due to high-fat reabsorption and volume loss. Addressing this, a novel drug delivery system uniquely combines a thermosensitive, FDA-approved hydrogel (itaconic acid-modified PLGA-PEG-PLGA copolymer) with FGF2-STAB, a stable fibroblast growth factor 2 with a 21-day stability, far exceeding a few hours of wild-type FGF2's stability. Additionally, the growth factor was encapsulated in "green" liposomes prepared via the Mozafari method, ensuring pH protection. The system, characterized by first-order FGF2-STAB release, employs green chemistry for biocompatibility, bioactivity, and eco-friendliness. The liposomes, with diameters of 85.73 ± 3.85 nm and 68.6 ± 2.2% encapsulation efficiency, allowed controlled FGF2-STAB release from the hydrogel compared to the unencapsulated FGF2-STAB. Yet, the protein compromised the carrier's hydrolytic stability. Prior tests were conducted on model proteins human albumin (efficiency 80.8 ± 3.2%) and lysozyme (efficiency 81.0 ± 2.7%). This injectable thermosensitive system could advance reconstructive medicine and cosmetic procedures.


Assuntos
Fator 2 de Crescimento de Fibroblastos , Lipossomos , Humanos , Polietilenoglicóis/química , Sistemas de Liberação de Medicamentos , Hidrogéis/química , Poliglactina 910/química , Portadores de Fármacos/química
18.
Indian J Ophthalmol ; 72(2): 223-227, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38099382

RESUMO

PURPOSE: To evaluate the clinical outcomes with fibrin glue in comparison with vicryl sutures for limbal conjunctival wound closure in strabismus surgery. METHODS: In this prospective interventional study, patients undergoing horizontal muscle strabismus surgery were randomized into two groups: the vicryl suture group and the fibrin glue group. The limbal conjunctival incisions were closed with 8-0 vicryl in the suture group and with fibrin glue in the other group. The outcomes measured were post-operative conjunctival inflammation and wound apposition, patient comfort with the help of a questionnaire, and conjunctival thickness using anterior segment optical coherence tomography (AS-OCT) for both groups at 6 weeks. RESULTS: The study included 64 eyes of 64 patients (32 eyes in each group). The fibrin glue group performed better than the vicryl suture group for most of the symptoms like redness, irritation, watering, and foreign body sensation till 2 weeks post-operatively ( P < 0.001), after which both the groups performed similarly. As for clinical signs, no significant difference was noted between the two groups, except for conjunctival hyperemia, which was significantly lesser in the fibrin glue group at 2 weeks post-operatively ( P < 0.001). The conjunctival thickness measured at 6 weeks using AS-OCT revealed that the thickness increased significantly in the suture group compared to that in the glue group ( P < 0.001 medial site, P = 0.004 lateral site). CONCLUSION: Because of greater patient comfort and reduced inflammation associated with fibrin glue, it may be considered as a procedure of choice for conjunctival wound closure in strabismus surgery in the absence of the cost constraints.


Assuntos
Conjuntivite , Pterígio , Estrabismo , Adesivos Teciduais , Humanos , Adesivo Tecidual de Fibrina/farmacologia , Adesivo Tecidual de Fibrina/uso terapêutico , Adesivos Teciduais/uso terapêutico , Poliglactina 910 , Estudos Prospectivos , Túnica Conjuntiva/cirurgia , Técnicas de Sutura , Estrabismo/cirurgia , Inflamação , Suturas , Pterígio/cirurgia
19.
Tissue Eng Part A ; 30(5-6): 214-224, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38126344

RESUMO

Many surgical tendon repairs fail despite advances in surgical materials and techniques. Tendon repair failure can be partially attributed to the tendon's poor intrinsic healing capacity and the repurposing of sutures from other clinical applications. Electrospun materials show promise as a biological scaffold to support endogenous tendon repair, but their relatively low tensile strength has limited their clinical translation. It is hypothesized that combining electrospun fibers with a material with increased tensile strength may improve the suture's mechanical properties while retaining biophysical cues necessary to encourage cell-mediated repair. This article describes the production of a hybrid electrospun-extruded suture with a sheath of submicron electrospun fibers and a core of melt-extruded fibers. The porosity and tensile strength of this hybrid suture is compared with an electrospun-only braided suture and clinically used sutures Vicryl and polydioxanone (PDS). Bioactivity is assessed by measuring the adsorbed serum proteins on electrospun and melt-extruded filaments using mass spectrometry. Human hamstring tendon fibroblast attachment and proliferation were quantified and compared between the hybrid and control sutures. Combining an electrospun sheath with melt-extruded cores created a hybrid braid with increased tensile strength (70.1 ± 0.3N) compared with an electrospun only suture (12.9 ± 1 N, p < 0.0001). The hybrid suture had a similar force at break to clinical sutures, but lower stiffness and stress. The Young's modulus was 772.6 ± 32 MPa for the hybrid suture, 1693.0 ± 69 MPa for PDS, and 3838.0 ± 132 MPa for Vicryl, p < 0.0001. Hybrid sutures had lower overall porosity than electrospun-only sutures (40 ± 4% and 60 ± 7%, respectively, p = 0.0018) but had a significantly larger overall porosity and average pore diameter compared with surgical sutures. There were similar clusters of adsorbed proteins on electrospun and melt-extruded filaments, which were distinct from PDS. Tendon fibroblast attachment and cell proliferation on hybrid and electrospun sutures were significantly higher than on clinical sutures. This study demonstrated that a bioactive suture with increased tensile strength and lower stiffness could be produced by adding a core of 10 µm melt-extruded fibers to a sheath of electrospun fibers. In contrast to currently used sutures, the hybrid sutures promoted a bioactive response: serum proteins adsorbed, and fibroblasts attached, survived, grew along the sutures, and adopted appropriate morphologies.


Assuntos
Polidioxanona , Poliglactina 910 , Humanos , Técnicas de Sutura , Tendões/cirurgia , Suturas , Resistência à Tração , Proteínas Sanguíneas
20.
Am J Obstet Gynecol MFM ; 6(2): 101256, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38109995

RESUMO

BACKGROUND: Cesarean delivery is a commonly performed surgical procedure worldwide. There is limited good-quality evidence regarding subcuticular skin closure with absorbable sutures in transverse incisions after cesarean delivery. OBJECTIVE: This study aimed to compare poliglecaprone-25 (3-0) and polyglactin-910 (4-0) sutures for subcuticular skin closure in Pfannenstiel incisions among women undergoing cesarean delivery. STUDY DESIGN: In this double-blind, single-center, randomized controlled trial among women undergoing cesarean delivery (elective and emergency), 200 women were randomized (Group 1-subcuticular skin closure with poliglecaprone-25 [3-0] vs Group 2-subcuticular skin closure with polyglactin-910 [4-0]). All women received similar preoperative and postoperative care. A sample size of 200 women was selected with the aim of reducing the composite wound complication rate from 15.8% to 3.6% with a power of 0.80 and a 2-tailed α of 0.05. Thus, 90 women were required in each group, but 100 were selected to account for attrition. RESULTS: Composite wound complications (including surgical site infection, hematoma, seroma, need for resuturing or readmission for wound complications) were similar in the 2 groups (Group 1 vs 2: 16 vs 10; P=.293; relative risk, 1.28; 95% confidence interval, 0.91-1.79). Surgical site infection (8 vs 7; P=1.000; relative risk, 1.08; 95% confidence interval, 0.64-1.83), hematoma (1 vs 2; P=.561; relative risk, 0.66; 95% confidence interval, 0.13-3.31), seroma (8 vs 2; P=.052; relative risk, 1.65; 95% confidence interval, 1.17-2.33), need for resuturing (4 vs 3; P=.700; relative risk, 1.15; 95% confidence interval, 0.60-2.22), and need for readmission (4 vs 4; P=1.000) were similar in the 2 groups. Pain score on the visual analog scale at 3 days (3.2±1.0 vs 3.6±1.2) and 6 weeks after operation (1.6±0.8 vs 1.7±0.9;) was significantly lower in Group 1 (P=.023 and P=.033, respectively). There was no difference between observer and patient scar assessment scores measured at 6 weeks after operation (P=.069 and P=.431, respectively). CONCLUSION: Poliglecaprone-25 (3-0) and polyglactin-910 (4-0) subcuticular sutures were comparable regarding composite wound complications (surgical site infection, hematoma, seroma, wound separation or re-suturing, need for readmission) and cosmetic appearance (patient scar assessment score & observer scar assessment score) related to skin closure among women undergoing cesarean delivery through a Pfannenstiel incision in nonobese women (average body mass index, 25).


Assuntos
Cicatriz , Poliglactina 910 , Gravidez , Feminino , Humanos , Poliglactina 910/efeitos adversos , Cicatriz/epidemiologia , Cicatriz/etiologia , Cicatriz/prevenção & controle , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/prevenção & controle , Técnicas de Sutura/efeitos adversos , Seroma/complicações , Hematoma/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...