Radiat Oncol ; 19(1): 86, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956685

RESUMO

PURPOSE: To apply an independent GPU-accelerated Monte Carlo (MC) dose verification for CyberKnife M6 with Iris collimator and evaluate the dose calculation accuracy of RayTracing (TPS-RT) algorithm and Monte Carlo (TPS-MC) algorithm in the Precision treatment planning system (TPS). METHODS: GPU-accelerated MC algorithm (ArcherQA-CK) was integrated into a commercial dose verification system, ArcherQA, to implement the patient-specific quality assurance in the CyberKnife M6 system. 30 clinical cases (10 cases in head, and 10 cases in chest, and 10 cases in abdomen) were collected in this study. For each case, three different dose calculation methods (TPS-MC, TPS-RT and ArcherQA-CK) were implemented based on the same treatment plan and compared with each other. For evaluation, the 3D global gamma analysis and dose parameters of the target volume and organs at risk (OARs) were analyzed comparatively. RESULTS: For gamma pass rates at the criterion of 2%/2 mm, the results were over 98.0% for TPS-MC vs.TPS-RT, TPS-MC vs. ArcherQA-CK and TPS-RT vs. ArcherQA-CK in head cases, 84.9% for TPS-MC vs.TPS-RT, 98.0% for TPS-MC vs. ArcherQA-CK and 83.3% for TPS-RT vs. ArcherQA-CK in chest cases, 98.2% for TPS-MC vs.TPS-RT, 99.4% for TPS-MC vs. ArcherQA-CK and 94.5% for TPS-RT vs. ArcherQA-CK in abdomen cases. For dose parameters of planning target volume (PTV) in chest cases, the deviations of TPS-RT vs. TPS-MC and ArcherQA-CK vs. TPS-MC had significant difference (P < 0.01), and the deviations of TPS-RT vs. TPS-MC and TPS-RT vs. ArcherQA-CK were similar (P > 0.05). ArcherQA-CK had less calculation time compared with TPS-MC (1.66 min vs. 65.11 min). CONCLUSIONS: Our proposed MC dose engine (ArcherQA-CK) has a high degree of consistency with the Precision TPS-MC algorithm, which can quickly identify the calculation errors of TPS-RT algorithm for some chest cases. ArcherQA-CK can provide accurate patient-specific quality assurance in clinical practice.


Assuntos
Algoritmos , Método de Monte Carlo , Órgãos em Risco , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Humanos , Radiocirurgia/métodos , Radiocirurgia/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação , Neoplasias/cirurgia , Neoplasias/radioterapia , Radioterapia de Intensidade Modulada/métodos , Gráficos por Computador
2.
J Appl Clin Med Phys ; 25(6): e14388, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38762906

RESUMO

BACKGROUND: The ZAP-X system is a novel gyroscopic radiosurgical system based on a 3 MV linear accelerator and collimator cones with a diameter between 4 and 25 mm. Advances in imaging modalities to detect small and early-stage pathologies allow for an early and less invasive treatment, where a smaller collimator matching the anatomical target could provide better sparing of surrounding healthy tissue. PURPOSE: A novel 3 mm collimator cone for the ZAP-X was developed. This study aims to investigate the usability of a commercial diode detector (microSilicon) for the dosimetric characterization of this small collimator cone; and to investigate the underlying small field perturbation effects. METHODS: Profile measurements in five depths as well as PDD and output ratio measurements were performed with a microSilicon detector and radiochromic EBT3 films. In addition, comprehensive Monte Carlo simulations were performed to validate the measurement observations and to quantify the perturbation effects of the microSilicon detector in these extremely small field conditions. RESULTS: It is shown that the microSilicon detector enables an accurate dosimetric characterization of the 3 mm beam. The profile parameters, such as the FWHM and 20%-80% penumbra width, agree within 0.1 to 0.2 mm between film and detector measurements. The output ratios agree within the measurement uncertainty between microSilicon detector and films, whereas the comparisons of the PDD results show good agreement with the Monte Carlo simulations. The analysis of the perturbation factors of the microSilicon detector reveals a small field correction factor of approximately 3% for the 3 mm circular beam and a correction factor smaller than 1.5% for field diameters above 3 mm. CONCLUSIONS: It could be shown that the microSilicon detector is well-suitable for the characterization of the new 3 mm circular beam of the ZAP-X system.


Assuntos
Método de Monte Carlo , Aceleradores de Partículas , Imagens de Fantasmas , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radiocirurgia/métodos , Radiocirurgia/instrumentação , Humanos , Aceleradores de Partículas/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radiometria/métodos , Radiometria/instrumentação , Simulação por Computador , Radioterapia de Intensidade Modulada/métodos , Silício/química
3.
Med Phys ; 51(6): 4423-4433, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38695760

RESUMO

BACKGROUND: The newly available ZAP-X stereotactic radiosurgical system is designed for the treatment of intracranial lesions, with several unique features that include a self-shielding, gyroscopic gantry, wheel collimation, non-orthogonal kV imaging, short source-axis distance, and low-energy megavoltage beam. Systematic characterization of its radiation as well as other properties is imperative to ensure its safe and effective clinical application. PURPOSE: To accurately determine the radiation output of the ZAP-X with a special focus on the smaller diameter cones and an aim to provide useful recommendations on quantification of small field dosimetry. METHODS: Six different types of detectors were used to measure relative output factors at field sizes ranging from 4 to 25 mm, including the PTW microSilicon and microdiamond diodes, Exradin W2 plastic scintillator, Exradin A16 and A1SL ionization chambers, and the alanine dosimeter. The 25 mm cone served as the reference field size. Absolute dose was determined with both TG-51-based dosimetry using a calibrated PTW Semiflex ion chamber and measurements using alanine dosimeters. RESULTS: The average radiation output factors (maximum deviation from the average) measured with the microDiamond, microSilicon, and W2 detectors were: for the 4 mm cone, 0.741 (1.0%); for the 5 mm cone: 0.817 (1.0%); for the 7.5 mm cone: 0.908 (1.0%); for the 10 mm cone: 0.946 (0.4%); for the 12.5 mm cone: 0.964 (0.2%); for the 15 mm cone: 0.976 (0.1%); for the 20 mm cone: 0.990 (0.1%). For field sizes larger than 10 mm, the A1SL and A16 micro-chambers also yielded consistent output factors within 1.5% of those obtained using the microSilicon, microdiamond, and W2 detectors. The absolute dose measurement obtained with alanine was within 1.2%, consistent with combined uncertainties, compared to the PTW Semiflex chamber for the 25 mm reference cone. CONCLUSION: For field sizes less than 10 mm, the microSilicon diode, microDiamond detector, and W2 scintillator are suitable devices for accurate small field dosimetry of the ZAP-X system. For larger fields, the A1SL and A16 micro-chambers can also be used. Furthermore, alanine dosimetry can be an accurate verification of reference and absolute dose typically measured with ion chambers. Use of multiple suitable detectors and uncertainty analyses were recommended for reliable determination of small field radiation outputs.


Assuntos
Radiometria , Radiocirurgia , Radiocirurgia/instrumentação , Radiometria/instrumentação , Proteção Radiológica/instrumentação , Padrões de Referência
4.
J Appl Clin Med Phys ; 25(5): e14343, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38569013

RESUMO

PURPOSE: Single-isocenter multi-target intracranial stereotactic radiotherapy (SIMT) is an effective treatment for brain metastases with complex treatment plans and delivery optimization necessitating rigorous quality assurance. This work aims to assess five methods for quality assurance of SIMT treatment plans in terms of their suitability and sensitivity to delivery errors. METHODS: Sun Nuclear ArcCHECK and SRS MapCHECK, GafChromic EBT Radiochromic Film, machine log files, and Varian Portal Dosimetry were all used to measure 15 variations of a single SIMT plan. Variations of the original plan were created with Python. They comprised various degrees of systematic MLC offsets per leaf up to 2 mm, random per-leaf variations with differing minimum and maximum magnitudes, simulated collimator, and dose miscalibrations (MU scaling). The erroneous plans were re-imported into Eclipse and plan-quality degradation was assessed by comparing each plan variation to the original clinical plan in terms of the percentage of clinical goals passing relative to the original plan. Each erroneous plan could be then ranked by the plan-quality degradation percentage following recalculation in the TPS so that the effects of each variation could be correlated with γ pass rates and detector suitability. RESULTS & CONCLUSIONS: It was found that 2%/1 mm is a good starting point for the ArcCHECK, Portal Dosimetry, and the SRS MapCHECK methods, respectively, and provides clinically relevant error detection sensitivity. Looser dose criteria of 5%/1 mm or 5%/1.5 mm are suitable for film dosimetry and log-file-based methods. The statistical methods explored can be expanded to other areas of patient-specific QA and detector assessment.


Assuntos
Neoplasias Encefálicas , Garantia da Qualidade dos Cuidados de Saúde , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Encefálicas/radioterapia , Radiocirurgia/métodos , Radiocirurgia/instrumentação , Garantia da Qualidade dos Cuidados de Saúde/normas , Radioterapia de Intensidade Modulada/métodos , Aceleradores de Partículas/instrumentação , Radiometria/métodos , Radiometria/instrumentação , Algoritmos
5.
Phys Med ; 121: 103370, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38677196

RESUMO

The Leksell Gamma Knife® Perfexion™ and Icon™ have a unique geometry, containing 192 60Co sources with collimation for field sizes of 4 mm, 8 mm, and 16 mm. 4 mm and 8 mm collimated fields lack lateral charged particle equilibrium, so accurate field output factors are essential. This study performs field output factor measurements for the microDiamond, microSilicon, and RAZOR™ Nano detectors. 3D printed inserts for the spherical Solid Water® Phantom were fabricated for microDiamond detector, the microSilicon unshielded diode and the RAZOR™ Nano micro-ionisation chamber. Detectors were moved iteratively to identify the peak detector signal for each collimator, representing the effective point of measurement of the chamber. In addition, field output correction factors were calculated for each detector relative to vendor supplied Monte Carlo simulated field output factors and field output factors measured with a W2 scintillator. All field output factors where within 1.1 % for the 4 mm collimator and within 2.3 % for the 8 mm collimator. The 3D printed phantom inserts were suitable for routine measurements if the user identifies the effective point of measurement, and ensures a reproducible setup by marking the rotational alignment of the cylindrical print. Measurements with the microDiamond and microSilicon can be performed faster compared to the RAZOR™ Nano due to differences in the signal to noise ratio. All detectors are suitable for field output factor measurements for the Leksell Gamma Knife® Perfexion™ and Icon™.


Assuntos
Imagens de Fantasmas , Impressão Tridimensional , Radiometria , Radiocirurgia , Radiocirurgia/instrumentação , Radiometria/instrumentação , Método de Monte Carlo
6.
Radiol Phys Technol ; 17(2): 389-395, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38466497

RESUMO

To investigate the geometric accuracy of the radiation focal point (RFP) and cone-beam computed tomography (CBCT) over long-term periods for the ICON Leksell Gamma Knife radiosurgery system. This phantom study utilized the ICON quality assurance tool plus, and the phantom was manually set on the patient position system before the implementation of treatment for patients. The deviation of the RFP position from the unit center point (UCP) and the positions of the four ball bearings (BBs) in the CBCT from the reference position were automatically analyzed. During 544 days, a total of 269 analyses were performed on different days. The mean ± standard deviation (SD) of the deviation between measured RFP and UCP was 0.01 ± 0.03, 0.01 ± 0.03, and -0.01 ± 0.01 mm in the X, Y, and Z directions, respectively. The deviations with offset values after the cobalt-60 source replacement (0.00 ± 0.03, -0.01 ± 0.01, and -0.01 ± 0.01 mm in the X, Y, and Z directions, respectively) were significantly (p = 0.001) smaller than those before the replacement (0.02 ± 0.03, 0.02 ± 0.01, and -0.02 ± 0.01 mm in the X, Y, and Z directions, respectively). The overall mean ± SD of four BBs was -0.03 ± 0.03, -0.01 ± 0.05, and 0.01 ± 0.03 mm in the X, Y, and Z directions, respectively. Geometric positional accuracy was ensured to be within 0.1 mm on most days over a long-term period of more than 500 days.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Imagens de Fantasmas , Radiocirurgia , Radiocirurgia/instrumentação , Garantia da Qualidade dos Cuidados de Saúde , Humanos , Controle de Qualidade , Fatores de Tempo
7.
Radiol Phys Technol ; 17(2): 527-535, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38526690

RESUMO

This study analyse setup time (ST) and frequency of on-board imaging for stereotactic abdomen (liver, stomach), lung, and spine radiotherapy in the absence of automatic rotational correction. Total 53 stereotactic body radiotherapy (SBRT) patients, 28 of abdomen, 19 lung, and 6 spine treated for 230 sessions in O-ring gantry accelerator were evaluated for ST analysis. The mean setup time for all patients, abdomen, lung, and spine cases were 7.7 ± 7.4 min, 9.2 ± 9.2 min, 6.3 ± 4.1 min, and 5.5 ± 3.3 min, respectively. Median number CBCT was 2. 96% of cases had a CBCT between 1 and 3, and 9 (4%) had ≥ 4 CBCTs. Overall, 38.1%, 35.5%, 22.1%, 2.2%, and 2.2% of setup time fall into window of 0-5 min, 5-10 min, 10-20 min, 20-30 min, and > 30 min. Most difficult challenge is to negotiate with unknown rotational errors. It will be easy to dealt with them without automatic rotational correction if values are known.


Assuntos
Aceleradores de Partículas , Radiocirurgia , Radiocirurgia/métodos , Radiocirurgia/instrumentação , Humanos , Fatores de Tempo , Rotação , Tomografia Computadorizada de Feixe Cônico , Erros de Configuração em Radioterapia/prevenção & controle , Planejamento da Radioterapia Assistida por Computador/métodos
8.
Phys Eng Sci Med ; 47(2): 455-463, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38285271

RESUMO

Single plan techniques for multiple brain targets (MBT) stereotactic radiosurgery (SRS) are now routine. Patient specific quality assurance (QA) for MBT poses challenges due to the limited capabilities of existing QA tools which necessitates several plan redeliveries. This study sought to develop an SRS QA phantom that enables flexible MBT patient specific QA in a single delivery, along with complex SRS commissioning. PLA marble and PLA StoneFil materials were selected based on the literature and previous research conducted in our department. The HU numbers were investigated to determine the appropriate percentage infill for skull and soft-tissue equivalence. A Prusa MK3S printer in conjunction with the above-mentioned filaments were used to print the SRS QA phantom. Quality control (QC) was performed on the printed skull, film inserts and plugs for point dose measurements. EBT3 film and point dose measurements were performed using a CC04 ionisation chamber. QC demonstrated that the SRS QA phantom transverse, coronal and sagittal film planes were orthogonal within 0.5°. HU numbers for the skull, film inserts and plugs were 858 ± 20 and 35 ± 12 respectively. Point and EBT3 film dose measurements were within 2.5% and 3%/2 mm 95% gamma pass rate, respectively except one Gross Tumour Volume (GTV) that had a slightly lower gamma pass rate. Dose distributions to five GTVs were measured with EBT3 film in a single plan delivery on CyberKnife. In conclusion, an SRS QA phantom was designed, and 3D printed and its use for performing complex MBT patient specific QA in a single delivery was demonstrated.


Assuntos
Encéfalo , Imagens de Fantasmas , Impressão Tridimensional , Garantia da Qualidade dos Cuidados de Saúde , Radiocirurgia , Radiocirurgia/instrumentação , Humanos , Encéfalo/cirurgia , Encéfalo/diagnóstico por imagem , Garantia da Qualidade dos Cuidados de Saúde/normas , Controle de Qualidade , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica
9.
Sci Rep ; 12(1): 14357, 2022 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-35999356

RESUMO

We aimed to evaluate the radiographic and clinical outcomes after gamma knife radiosurgery (GKRS) for trigeminal schwannomas (TSs). A total of 87 patients who underwent GKRS for TSs between 1990 and 2020 were enrolled. The mean tumor volume was 4.3 cm3. The median prescribed dose for the margins of the tumor was 13 Gy. The median follow-up duration was 64.3 months (range 12.0-311.5 months). The overall local tumor control rate was 90%, and the symptom response rate was 93%. The response rate for each symptom was 88% for facial pain, 97% for facial sensory change, and 86% for cranial nerve deficits. Nineteen (22%) patients showed transient swelling, which had regressed at the time of the last follow-up. Cystic tumors were associated with transient swelling (p = 0.04). A tumor volume of < 2.7 cm3 was associated with local tumor control in univariable analysis. Transient swelling was associated with symptom control failure in both univariable and multivariable analyses (p = 0.04, odds ratio 14.538). GKRS is an effective treatment for TSs, both for local control and symptom control.


Assuntos
Neoplasias dos Nervos Cranianos/cirurgia , Neurilemoma/cirurgia , Radiocirurgia/instrumentação , Doenças do Nervo Trigêmeo/cirurgia , Neoplasias dos Nervos Cranianos/diagnóstico por imagem , Neoplasias dos Nervos Cranianos/radioterapia , Dor Facial/radioterapia , Dor Facial/cirurgia , Seguimentos , Humanos , Neurilemoma/diagnóstico por imagem , Neurilemoma/radioterapia , Estudos Retrospectivos , Resultado do Tratamento , Doenças do Nervo Trigêmeo/diagnóstico por imagem , Doenças do Nervo Trigêmeo/radioterapia , Carga Tumoral
10.
J Neurooncol ; 160(1): 23-31, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35882752

RESUMO

BACKGROUND: Intraventricular meningiomas (IVMs) are rare tumors with considerable treatment-associated morbidity due to their challenging location. Treatment with stereotactic radiosurgery (SRS) is sparsely reported in the literature. We describe our experience over the last 35 years using Gamma knife radiosurgery (GKRS) for IVMs. METHODS: We retrospectively reviewed the GKRS database identifying 2501 meningiomas treated at the University of Pittsburgh Medical Center over the last 35 years. Nineteen patients with (12 males, mean age = 53.2 years, range 14-84) 20 IVMs were identified. Headache was the most frequent presenting symptom (N = 12), and the trigone of the lateral ventricle was the most common location (N = 18). The median tumor volume was 4.8 cc (range, 0.8-17). The median margin dose was 14 Gy (range, 12-25) delivered at 50% isodose line. RESULTS: At a median follow-up of 63.1 months (range, 6-322.4) symptom control was achieved in 18 (94.7%) patients. The overall progression-free survival (PFS) was 95% at 5 years, and 85% at 10-years. After Log-rank test, patients who underwent GKRS within 12 months after diagnosis (vs. ≥ 12 months, X2: 4.455, p = 0.035), patients treated with primary GKRS without prior biopsy (vs. prior biopsy, X2: 4.000, p = 0.046), and patients with WHO grade I meningioma (vs. WHO II, X2: 9.000, p = 0.003) had a longer PFS. Imaging showed peritumoral edema in seven cases at a median of 10.5 (range, 6.13-24.3) months after GKRS. Only three of these patients were symptomatic and were successfully managed with oral medications. Cox´s regression revealed that a V12Gy ≥ 10 cc [HR: 10.09 (95% CI: 2.11-48.21), p = 0.004], and tumor volume ≥ 8 cc [HR: 5.87 (95% CI: 1.28-26.97), p = 0.023] were associated with a higher risk of peritumoral edema. CONCLUSION: GKRS is an effective and safe management option for intraventricular meningiomas. Early GKRS should be considered as a primary management modality for small and medium sized IVM and adjuvant management for residual IVMs.


Assuntos
Neoplasias do Ventrículo Cerebral , Neoplasias Meníngeas , Meningioma , Radiocirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Neoplasias do Ventrículo Cerebral/radioterapia , Seguimentos , Neoplasias Meníngeas/radioterapia , Meningioma/radioterapia , Radiocirurgia/efeitos adversos , Radiocirurgia/instrumentação , Estudos Retrospectivos , Resultado do Tratamento
11.
Radiat Oncol ; 17(1): 38, 2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35193630

RESUMO

PURPOSE: Boosting dominant intra-prostatic lesions (DILs) has the potential to increase the therapeutic ratio in prostate cancer radiotherapy. In this study, employing 5-fraction stereotactic ablative radiotherapy (SABR) volumetric modulated arc therapy (VMAT) to deliver 40 Gy to the prostate clinical target volume (CTV) while boosting the DIL up to 50 Gy was evaluated for patients before and after rectal spacer insertion. MATERIALS AND METHODS: 24 Computed Tomography (CT) scans of 12 prostate cancer patients with unfavourable intermediate or high risk prostate cancer were employed in this study. At least two treatment plans were generated for each patient to compare pre- and post-spacer insertion plans. Plans were evaluated for target coverage, organs-at-risk doses, and the achievable boost dose level. RESULTS: The CTV coverage was significantly better in plans with a spacer, V40Gy 98.4% versus 97.0% (p = 0.012). Using spacers significantly reduced rectal dose in all 12 patients in this study. It was possible to boost DIL to 50 Gy to without violating dose constraints in 6 of 12 patients and to 47.5 Gy in 3 patients post-spacer insertion. For 3 patients (25%) it was not possible to boost DIL above 45 Gy even with a spacer in situ. Without a spacer, for 6 patient (50%) clinically acceptable plan were only achieved when the DIL dose was lowered to 45 Gy. In five of these 6 patients the dose limiting structure was the urethra (urethra planning risk volume V45Gy [cc] ≤ 0.1 cc constraint). CONCLUSIONS: Clinically acceptable plans for 5 fraction SABR, 40 Gy to the prostate CTV, with a SIB to DIL (45-50 Gy) were achieved. The boost dose achieved was DIL location dependent and primarily affected by DIL's proximity to the urethra. Compared to plans before spacer insertion, higher DIL dose were achieved with spacer in situ for 25% of the patients. Moreover, significant reduction in rectal dose and better target coverage were also achieved for all patients with spacers in situ.


Assuntos
Adenocarcinoma/radioterapia , Neoplasias da Próstata/radioterapia , Hipofracionamento da Dose de Radiação , Radiocirurgia/instrumentação , Radioterapia de Intensidade Modulada/instrumentação , Humanos , Masculino , Reto
12.
Asian Pac J Cancer Prev ; 22(12): 4031-4035, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34967585

RESUMO

BACKGROUND: Measurement of Collimator helmet factors (CHF) is an important quality assurance procedure to be performed on Leksell Gamma Knife unit at regular interval to make sure that the interchangeable collimator helmet fit into the source channels without any positional inaccuracy which leads to major treatment error. The primary aim of this study is to measure the CHFs for Elekta Leksell Gamma knife 4C helmets using GafChromic EBT3 film and Image J software. METHODS: GafChromic EBT3 film, EPSON expression 10000 XL scanner and Image J analysis software was used for this study. The calibration curve of GafChromic EBT3 film was generated with known dose values for 14 mm collimator helmet using ImageJ software. The collimator helmet factor (CHF) for 4mm, 8mm and 14 mm collimator helmets were measured by normalizing dose rates of 4mm, 8mm and 14 mm to the dose rate of 18 mm collimator helmet using the previously generated calibration curve. The measured CHF was compared to Elekta reference value and previously published mean values. RESULTS: The measured CHFs were 0.896, 0.958, and 0.986 for 4mm, 8mm and 14mm collimators respectively. The percentage difference obtained was 1.7 %, 0.21 %, 0.1 % between measured values and reference values. CONCLUSION: The measurement of CHFs in LGK 4C unit using GafChromic EBT3 film and ImageJ software is a reliable method to verify the manufacturer quoted CHFs in routine quality assurance procedures.


Assuntos
Dosimetria Fotográfica/normas , Dispositivos de Proteção da Cabeça/normas , Radiocirurgia/instrumentação , Calibragem , Humanos , Radiocirurgia/normas , Software
13.
Technol Cancer Res Treat ; 20: 15330338211039135, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34632866

RESUMO

Purpose: Tumor treating fields (TTFields) is a novel antimitotic treatment that was first proven effective for glioblastoma multiforme, now with trials for several extracranial indications underway. Several studies focused on concurrent TTFields therapy with radiation in the same time period, but were not given simultaneously. This study evaluates the targeting accuracy of simultaneous radiation therapy while TTFields arrays are in place and powered on, ensuring that radiation does not interfere with TTFields and TTFields does not interfere with radiation. This is one of several options to enable TTFields to begin several weeks sooner, and opens potential for synergistic effects of combined therapy. Methods: TTFields arrays were attached to a warm saline water bath and salt was added until the TTFields generator reached the maximal 2000 mA peak-to-peak current. A ball cube phantom containing 2 orthogonal films surrounded by fiducials was placed in the water phantom, CT scanned, and a radiation treatment plan with 58 isocentric beams was created using a 3 cm circular collimator. Fiducial tracking was used to deliver radiation, the films were scanned, and end-to-end targeting error was measured with vendor-supplied software. In addition, radiation effects on electric fields generated by the TTFields system were assessed by examining logfiles generated from the field generator. Results: With TTFields arrays in place and powered on, the robotic radiosurgery system achieved a final targeting result of 0.47 mm, which was well within the submillimeter specification. No discernible effects on TTFields current output beyond 0.3% were observed in the logfiles when the radiation beam pulsed on and off. Conclusion: A robotic radiosurgery system was used to verify that radiation targeting was not adversely affected when the TTFields arrays were in place and the TTFields delivery device was powered on. In addition, this study verified that radiation delivered simultaneously with TTFields did not interfere with the generation of the electric fields.


Assuntos
Neoplasias Encefálicas/radioterapia , Glioblastoma/radioterapia , Radioterapia/métodos , Terapia Combinada/métodos , Marcadores Fiduciais , Cabeça , Humanos , Mitose/efeitos da radiação , Imagens de Fantasmas , Hipofracionamento da Dose de Radiação , Radiocirurgia/instrumentação , Planejamento da Radioterapia Assistida por Computador , Robótica
14.
J Cancer Res Ther ; 17(4): 870-874, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34528534

RESUMO

AIM: The aim of this study was to measure and compare the output factor (OF) of a CyberKnife Robotic Radiosurgery System with eight different small field detectors and validate with Technical Report Series (TRS) report 483. BACKGROUND: Accurate dosimetry of CyberKnife system is limited due to the challenges in small field dosimetry. OF is a vital dosimetric parameter used in the photon beam modeling and any error would affect the dose calculation accuracy. MATERIALS AND METHODS: In this study, the OF was measured with eight different small-field detectors for the 12 IRIS collimators at 800 mm SAD setup at 15 mm depth. The detectors used were PTW 31016 PinPoint 3D, IBA PFD shielded diode, IBA EFD unshielded diode, IBA SFD unshielded diode (stereotactic), PTW 60008 shielded diode, PTW 60012 unshielded diode, PTW 60018 unshielded diode (stereotactic), and PTW 60019 CVD diamond detector. OF was obtained after correcting for field output correction factors from IAEA TRS No. 483. RESULTS: The field OFs in CyberKnife are derived from the measured data by applying the correction factors from Table 23 in TRS 483 for the eight small field detectors. These field OFs matched within 2% of peer-reviewed published values. The range and standard deviation showed a decreasing trend with collimator diameter. CONCLUSION: The field OF obtained after applying the appropriate correction factor from TRS 483 matched well with the peer-reviewed published OFs. The inter-detector variation showed a decreasing trend with increasing collimator field size. This study gives physicists confidence in measuring field OFs while using small field detectors mentioned in this work.


Assuntos
Método de Monte Carlo , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Radiocirurgia/instrumentação , Procedimentos Cirúrgicos Robóticos/instrumentação , Humanos
15.
Cancer Radiother ; 25(8): 755-762, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34565664

RESUMO

PURPOSE: A Benchmark Case (BC) was performed as part of the quality assurance process of the randomized phase 2 GORTEC 2014-14 OMET study, testing the possibility of multisite stereotactic radiation therapy (SBRT) alone in oligometastatic head and neck squamous cell carcinoma (HNSCC) as an alternative to systemic treatment and SBRT. MATERIAL AND METHODS: Compliance of the investigating centers with the prescription, delineation, planning and evaluation recommendations available in the research protocol was assessed. In addition, classical dosimetric analysis was supplemented by quantitative geometric analysis using conformation indices. RESULTS: Twenty centers participated in the BC analysis. Among them, four major deviations (MaD) were reported in two centers. Two (10%) centers in MaD had omitted the satellite tumor nodule and secondarily validated after revision. Their respective DICE indexes were 0.37 and 0 and use of extracranial SBRT devices suboptimal There were significant residual heterogeneities between participating centers, including those with a similar SBRT equipment, with impact of plan quality using standard indicators and geometric indices. CONCLUSION: A priori QA using a BC conditioning the participation of the clinical investigation centers showed deviations from good SBRT practice and led to the exclusion of one out of the twenty participating centers. The majority of centers have demonstrated rigorous compliance with the research protocol. The use of quality indexes adds a complementary approach to improve assessment of plan quality.


Assuntos
Benchmarking , Neoplasias de Cabeça e Pescoço/radioterapia , Radiocirurgia/normas , Carcinoma de Células Escamosas de Cabeça e Pescoço/radioterapia , França , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Metástase Neoplásica/radioterapia , Órgãos em Risco , Neoplasias Faríngeas/patologia , Neoplasias Faríngeas/radioterapia , Garantia da Qualidade dos Cuidados de Saúde , Radiometria , Radiocirurgia/instrumentação , Radiocirurgia/métodos , Dosagem Radioterapêutica , Carcinoma de Células Escamosas de Cabeça e Pescoço/secundário
16.
Radiat Oncol ; 16(1): 168, 2021 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-34461953

RESUMO

BACKGROUND: The objective of this study was to analyze the amplitude of translational and rotational movements occurring during stereotactic body radiotherapy (SBRT) of spinal metastases in two different positioning devices. The relevance of intra-fractional imaging and the influence of treatment time were evaluated. METHODS: Twenty patients were treated in the supine position either (1) on a body vacuum cushion with arms raised and resting on a clegecel or (2) on an integrated SBRT solution consisting of a SBRT table top, an Orfit™ AIO system, and a vacuum cushion. Alignments between the cone beam computed tomography (CBCT) and the planning computed tomography allowed corrections of inter- and intra-fraction positional shifts using a 6D table. The absolute values of the translational and rotational setup errors obtained for 329 CBCT were recorded. The translational 3D vector, the maximum angle, and the characteristic times of the treatment fractions were calculated. RESULTS: An improvement in the mean (SD) inter-fraction 3D vector (mm) from 7.8 (5.9) to 5.9 (3.8) was obtained by changing the fixation devices from (1) to (2) (p < 0.038). The maximum angles were less than 2° for a total of 87% for (1) and 96% for (2). The mean (SD) of the intra-fraction 3D vectors (mm) was lower for the new 1.1 (0.8) positioning fixation (2) compared to the old one (1) 1.7 (1.7) (p = 0.004). The angular corrections applied in the intra-fraction were on average very low (0.4°) and similar between the two systems. A strong correlation was found between the 3D displacement vector and the fraction time for (1) and (2) with regression coefficients of 0.408 (0.262-0.555, 95% CI) and 0.069 (0.010-0.128, 95% CI), respectively. An accuracy of 1 mm would require intra-fraction imaging every 5 min for both systems. If the expected accuracy was 2 mm, then only system (2) could avoid intra-fractional imaging. CONCLUSIONS: This study allowed us to evaluate setup errors of two immobilization devices for spine SBRT. The association of inter- and intra-fraction imaging with 6D repositioning of a patient is inevitable. The correlation between treatment time and corrections to be applied encourages us to move toward imaging modalities which allow a reduction in fraction time.


Assuntos
Radiocirurgia/métodos , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/secundário , Idoso , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento , Posicionamento do Paciente , Radiocirurgia/instrumentação , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Fatores de Tempo
17.
World Neurosurg ; 155: e382-e390, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34425292

RESUMO

OBJECTIVE: To assess long-term outcomes of hypofractionated stereotactic radiotherapy (hSRT) for head and neck paragangliomas (HNPGs). METHODS: Patients who underwent hSRT with CyberKnife for HNPGs from 2010 to 2019 were retrospectively reviewed. RESULTS: A total of 34 HNPGs in 29 patients were identified. Mean patient age was 50 ± 16 years, and 15 patients (52%) were female. Fifteen patients (55%) had undergone previous procedures. Four cases (14%) were functional in hormone production. According to the Fisch classification, 1 (3%) case was B, 12 (42%) cases were C, 14 (48%) cases were D, and 2 (7%) cases were unclassified.1 The median prescribed dose covering 95% of the planning target volume was 2500 cGy (interquartile range 2100-2600 cGy), and the median target volume was 10 cm3 (interquartile range 6.0-18.3 cm3). The local control rate was 97%. The median progression-free survival was 66 months (interquartile range 28-95 months), and 96% of patients were free of tumor progression at 8 years. During follow-up, 1 case (3%) resulted in permanent facial nerve palsy (House-Brackmann grade II), and another case (3%) resulted in asymptomatic cerebellar radiation necrosis. Univariate and multivariate analysis showed that no previous surgical history (odds ratio 8.58, 95% confidence interval 1.2-59.7, P = 0.03) was a positive predictor of symptomatic improvement. CONCLUSIONS: hSRT for HNPGs was an effective treatment with minimal side effects over the long term and may have a role as first-line therapy, especially for symptomatic nonfunctional HNPGs, for better symptom control.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/cirurgia , Paraganglioma/diagnóstico por imagem , Paraganglioma/cirurgia , Radiocirurgia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Radiocirurgia/instrumentação , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
18.
Cancer Radiother ; 25(8): 763-770, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34083125

RESUMO

PURPOSE: Hypofractionated stereotactic radiotherapy (HFSRT) has become a standard of care for patients with a limited number of brain metastases (BM). An increasing number of linear accelerators (LA) are able to accurately perform HFSRT including VersaHD® (Elekta®) LA. The main aim of this study was to report clinical outcomes of BM treated by HFSRT using 3×7.7Gy on 70% isodose line in terms of local control (LC). PATIENTS AND METHODS: Between November 2016 and October 2018, all patients suffering from histologically-proven primary with one or several newly diagnosed BM treated by HFSRT were retrospectively included and evaluated. Patients who had received prior treatment by neurosurgery or cerebral radiotherapy were excluded. RESULTS: Among 44 patients, 61 BM were treated. With a median follow-up of 31.9 months, LC rates at 6 and 12 months were 93.2% and 90.9, respectively. Single-BM was independently predictive of LC (P=0.025) and overall survival (P=0.013). Acute toxicity rates were acceptable: 65.9% of patients had grade 1 and 2 and no acute grade 3 toxicity according to the NCI-CTCAE (version 5.0). Regarding delayed toxicity, one case (2.3%) of radionecrosis was confirmed by magnetic resonance spectroscopy. CONCLUSION: In our single-centre retrospective analysis, BM treatment by HFSRT delivered in three fractions showed a 12-month LC rate of 90.9% without major toxicities, which suggests safety and efficiency of this technique. However, longer-term follow-up and prospective studies are still needed to confirm these results.


Assuntos
Neoplasias Encefálicas/radioterapia , Hipofracionamento da Dose de Radiação , Radiocirurgia/métodos , Neoplasias Encefálicas/mortalidade , Neoplasias Encefálicas/secundário , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Lesões por Radiação/epidemiologia , Radiocirurgia/efeitos adversos , Radiocirurgia/instrumentação , Estudos Retrospectivos , Resultado do Tratamento
19.
Radiat Oncol ; 16(1): 106, 2021 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-34118965

RESUMO

PURPOSE: The purpose of this study is to evaluate inter- and intra-fraction organ motion as well as to quantify clinical target volume (CTV) to planning target volume (PTV) margins to be adopted in the stereotactic treatment of early stage glottic cancer. METHODS AND MATERIALS: Stereotactic body radiotherapy (SBRT) to 36 Gy in 3 fractions was administered to 23 patients with early glottic cancer T1N0M0. Patients were irradiated with a volumetric intensity modulated arc technique delivered with 6 MV FFF energy. Each patient underwent a pre-treatment cone beam computed tomography (CBCT) to correct the setup based on the thyroid cartilage position. Imaging was repeated if displacement exceeded 2 mm in any direction. CBCT imaging was also performed after each treatment arc as well as at the end of the delivery. Swallowing was allowed only during the beam-off time between arcs. CBCT images were reviewed to evaluate inter- and intra-fraction organ motion. The relationships between selected treatment characteristics, both beam-on and delivery times as well as organ motion were investigated. RESULTS: For the population systematic (Æ©) and random (σ) inter-fraction errors were 0.9, 1.3 and 0.6 mm and 1.1, 1.3 and 0.7 mm in the left-right (X), cranio-caudal (Y) and antero-posterior (Z) directions, respectively. From the analysis of CBCT images acquired after treatment, systematic (Æ©) and random (σ) intra-fraction errors resulted 0.7, 1.6 and 0.7 mm and 1.0, 1.5 and 0.6 mm in the X, Y and Z directions, respectively. Margins calculated from the intra-fraction errors were 2.4, 5.1 and 2.2 mm in the X, Y and Z directions respectively. A statistically significant difference was found for the displacement in the Z direction between patients irradiated with > 2 arcs versus ≤ 2 arcs, (MW test, p = 0.038). When analyzing mean data from CBCT images for the whole treatment, a significant correlation was found between the time of delivery and the three dimensional displacement vector (r = 0.489, p = 0.055), the displacement in the Y direction (r = 0.553, p = 0.026) and the subsequent margins to be adopted (r = 0.626, p = 0.009). Finally, displacements and the subsequent margins to be adopted in Y direction were significantly greater for treatments with more than 2 arcs (MW test p = 0.037 and p = 0.019, respectively). CONCLUSIONS: In the setting of controlled swallowing during treatment delivery, intra-fraction motion still needs to be taken into account when planning with estimated CTV to PTV margins of 3, 5 and 3 mm in the X, Y and Z directions, respectively. Selected treatments may require additional margins.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Laríngeas/cirurgia , Movimentos dos Órgãos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Cirurgia Assistida por Computador/métodos , Humanos , Neoplasias Laríngeas/patologia , Prognóstico , Estudos Prospectivos , Radiocirurgia/instrumentação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
20.
Clin Transl Oncol ; 23(11): 2358-2367, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34043153

RESUMO

PURPOSE: To explore the feasibility of image-guided and respiratory-gated Stereotactic Body Radiation Therapy (SBRT) for Accelerated Partial Breast Irradiation (APBI) in patients with very early breast cancer. MATERIAL AND METHODS: Selected patients with early breast carcinoma after breast-conserving surgery were enrolled in this phase II trial. A fiducial marker was percutaneously placed close to surgical bed and five external fiducials were set on the skin. A CT scan for planning was acquired at free breathing. The treatment was planned and DVH were assessed according to international recommendations. Prescription dose was 30 Gy in five consecutive fractions of 6 Gy. A 6MV monoenergetic LINAC (linear accelerator) that combines stereoscopic X-ray imaging system and ExacTrac Adaptive Gating technique was used. PTV (planning target volume) intrafraction motion was controlled and PTV was irradiated in a selected gated area of the respiratory cycle. Shifts for a correct, gated set-up were calculated and automatically applied. RESULTS: Between April 2013 and October 2015, a total of 23 patients were included. The median tumor size was 12 mm. The mean PTV volume was 114 cc. The mean ipsilateral lung V9 Gy was 2.2% and for left-sided breast cancers, the volume of the heart receiving 1.5 Gy was 11.5%. Maximum skin dose was 30.8 Gy. Acute toxicity was grade1 in all the patients and 100% experienced excellent/good breast cosmesis outcomes. With a median follow-up of 66 months (range 8-99 months) local-relapse-free-survival reaches 100%. One patient developed a second breast cancer outside the treated quadrant after 25.1 months. CONCLUSION: APBI with SBRT and ExacTrac Adaptive Gating System was feasible. The acute and late toxicities were almost null and cosmesis was excellent. We also found that the margins of 5 mm applied from CTV to PTV were sufficient to compensate for geometric uncertainties.


Assuntos
Neoplasias da Mama/radioterapia , Carcinoma Ductal de Mama/radioterapia , Radiocirurgia/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/patologia , Carcinoma Ductal de Mama/cirurgia , Intervalo Livre de Doença , Fracionamento da Dose de Radiação , Estudos de Viabilidade , Feminino , Marcadores Fiduciais , Coração/efeitos da radiação , Humanos , Pulmão/efeitos da radiação , Mastectomia Segmentar , Pessoa de Meia-Idade , Movimentos dos Órgãos , Órgãos em Risco/efeitos da radiação , Cuidados Pós-Operatórios/métodos , Estudos Prospectivos , Radiocirurgia/instrumentação , Respiração , Pele/efeitos da radiação , Fatores de Tempo , Tomografia Computadorizada por Raios X , Carga Tumoral