Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.719
Filtrar
1.
Magy Onkol ; 68(2): 163-168, 2024 Jul 16.
Artigo em Húngaro | MEDLINE | ID: mdl-39013090

RESUMO

We present evaluation of junction of coplanar external beam photon fields and its portal dosimetric analysis for breast cancer with positive lymph nodes. In our work, we compared twelve patients affected by breast cancer with axillary and supraclavicular lymph nodes, using conformal external beam plans from a dosimetric point of view. 3-3 plans were prepared per patient. Three methods were used for the conformal technique to investigate the potential of lymph nodes treatment field's collimations. During the evaluation of the portal dosimetry images, it was concluded that the junction plane at isocenter appeared as a discrete coldline, when fitted the regional field with or without collimation manually and by the software. However, the coverage of the isocenter plane is strongly influenced by the linear accelerator and the fitted field edges. Based on our results, in order to avoid uncertainties arising from field junctions and the overdosed areas of the target volume, it is more appropriate to choose another advanced irradiation technique such as intensity-modulated radiation therapy.


Assuntos
Axila , Neoplasias da Mama , Linfonodos , Metástase Linfática , Fótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Humanos , Feminino , Neoplasias da Mama/radioterapia , Neoplasias da Mama/patologia , Linfonodos/efeitos da radiação , Linfonodos/patologia , Fótons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Metástase Linfática/radioterapia , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos
2.
J Cancer Res Ther ; 20(3): 999-1005, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-39023609

RESUMO

AIMS: This study aims to investigate the incidence rate of pulmonary fibrosis as a late radiotherapy complication and identify the associated dosimetric and demographic factors using radiological findings between Iranian patients with breast cancer. METHODS AND MATERIAL: Breast cancer patients treated at the education hospital of Shohada-e Tajrish Hospital, Tehran, Iran, from 2017 to 2021 were considered. Patients have included for whom a secondary chest CT scan was available at least six months after radiotherapy. Dose-volume histogram (DVH) parameters of three-dimensional conformal radiotherapy (3D-CRT) treatment plans were exported. Demographic features and data on underlying lung diseases, diabetes, and smoking history were extracted. RESULTS: A total of 250 patients were included in the study with a mean age of 46.1 ± 7.5 yrs and a mean body mass index (BMI) of 24.5 ± 4.2 kg/m2. Pulmonary fibrosis was detected for sixty-two cases. A significant relationship was obtained between the ipsilateral lung DVH parameters of patients with pulmonary fibrosis (P value < 0.05). The V5Gy, V10Gy, V13Gy, V20Gy, V30Gy, MLD, and DMax for individuals with pulmonary fibrosis were significantly higher than those without this injury. CONCLUSIONS: Pulmonary fibrosis was distinguished for 25% of the breast cancer cases at least six months after adjuvant radiotherapy. A significant relationship between the DVH parameters, underlying lung disease, diabetes, radiotherapy fields (i.e., Breast + LN + SC or Breast/Chest-wall only), age, and BMI with the frequency of the ipsilateral pulmonary fibrosis was obtained. V13Gy and V30Gy of the ipsilateral lung may be the most predictor of pulmonary fibrosis incidence.


Assuntos
Neoplasias da Mama , Fibrose Pulmonar , Humanos , Feminino , Neoplasias da Mama/radioterapia , Neoplasias da Mama/epidemiologia , Neoplasias da Mama/patologia , Pessoa de Meia-Idade , Irã (Geográfico)/epidemiologia , Estudos Transversais , Fibrose Pulmonar/etiologia , Fibrose Pulmonar/epidemiologia , Radioterapia Adjuvante/efeitos adversos , Prevalência , Adulto , Radioterapia Conformacional/efeitos adversos , Lesões por Radiação/epidemiologia , Lesões por Radiação/etiologia , Lesões por Radiação/diagnóstico , Dosagem Radioterapêutica , Incidência
3.
Acta Oncol ; 63: 511-517, 2024 06 30.
Artigo em Inglês | MEDLINE | ID: mdl-38946286

RESUMO

PURPOSE: In evaluating second primary cancers (SPCs) following External Beam Radiotherapy (EBRT), the role of lifestyle factors is frequently not considered due to data limitations. We investigated the association between smoking, comorbidities, and SPC risks within EBRT-treated patients for localized prostate cancer (PCa). PATIENTS & METHODS: The study included 1,883 PCa survivors aged 50-79, treated between 2006 and 2013, with intensity-modulated radiotherapy (IMRT) or three-dimensional conformal radiotherapy (3D-CRT). Clinical data were combined with SPC and survival data from the Netherlands Cancer Registry with a 12-month latency period. Standardized Incidence Ratios (SIRs) were calculated comparing the EBRT cohort with the general Dutch population. To explore the effect of patient and treatment characteristics on SPCs we conducted a Cox regression analysis. Lastly, we estimated cumulative incidences of developing solid SPC, pelvis SPC, and non-pelvis SPC using a competing risk analysis. RESULTS: Significantly increased SIRs were observed for all SPC (SIR = 1.21, 95% confidence interval [CI]: 1.08-1.34), pelvis SPC (SIR = 1.46, 95% CI: 1.18-1.78), and non-pelvis SPC (SIR = 1.18, 95% CI [1.04-1.34]). Smoking status was significantly associated with pelvic and non-pelvic SPCs. Charlson comorbidity index (CCI) ≥ 1 (Hazard Ratio [HR] = 1.45, 95% CI: 1.10-1.91), cardiovascular disease (HR = 1.41, 95% CI: 1.05-1.88), and chronic obstructive pulmonary disease (COPD) (HR = 1.91, 95% CI: 1.30-2.79) were significantly associated with non-pelvis SPC. The proportion of active smoking numbers in the cohort was similar to the general population. INTERPRETATION: We conclude that the presence of comorbidities in the EBRT population might be a relevant factor in observed excess non-pelvis SPC risk, but not for excess pelvis SPC risk.


Assuntos
Segunda Neoplasia Primária , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/epidemiologia , Segunda Neoplasia Primária/epidemiologia , Segunda Neoplasia Primária/etiologia , Idoso , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Fatores de Risco , Incidência , Radioterapia de Intensidade Modulada/efeitos adversos , Comorbidade , Fumar/epidemiologia , Fumar/efeitos adversos , Radioterapia Conformacional/efeitos adversos , Neoplasias Induzidas por Radiação/epidemiologia , Neoplasias Induzidas por Radiação/etiologia , Sistema de Registros/estatística & dados numéricos
4.
Radiat Prot Dosimetry ; 200(13): 1274-1293, 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39003236

RESUMO

The verification and use of the best treatment approach using 3D conformal radiation therapy (3DCRT), intensity modulated radiation therapy (IMRT) and Rapid Arc methods for left breast radiation with dosimetric and radiobiological characteristics. The use of custom-built Python software for the estimation and comparison of volume, mean dose, maximum dose, monitor units and normal tissue integral dose along with radiobiological parameters such as NTCP, tumor control probability, equivalent uniform dose and LKB's effective volume from 3DCRT, IMRT and Rapid Arc planning with deep inspiration with breath holding (DIBH) and free breadth (FB) techniques. Volume growth of three-fourth in DIBH compared with FB causes a decrease in cardiac doses and complications because the left lung expands, pulling the heart away from the chest wall and the treatment area. A tiny area of the left lung was exposed during treatment, which reduced the mean dose. There was little difference in the treatment approaches because the spinal cord was immobile in both techniques. Rapid Arc is the unmatched modality for left-sided breast irradiation with significant patient breath-hold, as shown by the comparison of dosimetric and radiobiological parameters from treatment techniques with a deep inspiration breath-hold approach.


Assuntos
Suspensão da Respiração , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Neoplasias Unilaterais da Mama , Humanos , Feminino , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Unilaterais da Mama/radioterapia , Radioterapia Conformacional/métodos , Órgãos em Risco/efeitos da radiação , Radiometria/métodos
5.
Radiother Oncol ; 199: 110435, 2024 10.
Artigo em Inglês | MEDLINE | ID: mdl-39004227

RESUMO

BACKGROUND: Locally advanced non-small cell lung cancer (LA-NSCLC) reported poor 5-year survival rates with frequent local or regional recurrences. Personalized RT may contribute to improve control and clinical outcome. We investigated efficacy and tolerance of "Mid-position" (Mid-P) strategy versus the conventional Internal Target Volume (ITV) strategy in LA-NSCLC patients treated by definitive conformal radiotherapy. METHODS: This prospective non-comparative randomized monocentric phase II trial included adult patients with non-resected, non-metastatic, non-previously irradiated proven LA-NSCLC treated with definitive normo-fractionated conformal radiotherapy (+/- chemotherapy). Allocated patients (randomisation 2:1) were treated using Mid-P or ITV strategy. A Fleming single-stage design (1-sided α = 0.1, 80 % power, P0 = 30 %, P1 = 50 %) planned enrolment of 36 patients in the Mid-P group. The ITV group ensured the absence of selection bias. The primary outcome was 1-year progression-free- survival (1y-PFS) rate. RESULTS: Among 54 eligible patients included from September 2012 to May 2018, 51 patients were analyzed (Mid-P: N = 34; ITV: 17). The 1y-PFS was 38 % (1-sided 95 %CI 25 %-not reached) with Mid-P strategy, and 47 % (95 %CI [27 %-not reached[) with ITV. Loco-regional failure as first event mainly occurred within radiation-field regardless the strategy. Acute and middle-term radiation toxicities were observed with both strategies. CONCLUSION: Local control and survival remain poor using the Mid-P strategy in this prospective randomized non-comparative monocentric study investigating Mid-P strategy versus ITV strategy in LA-NSCLC. Since the Mid-P strategy is not integrated into routine software, and perceived as a time-consuming method, Mid-P strategy cannot be recommended in LA-NSCLCC treated by definitive normo-fractionated conformal radiotherapy outside clinical trials.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radioterapia Conformacional , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/mortalidade , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/mortalidade , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Estudos Prospectivos , Radioterapia Conformacional/métodos , Radioterapia Conformacional/efeitos adversos , Idoso de 80 Anos ou mais
6.
JAMA Oncol ; 10(8): 1111-1115, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38935373

RESUMO

Importance: The optimal radiotherapy technique for unresectable locally advanced non-small cell lung cancer (NSCLC) is controversial, so evaluating long-term prospective outcomes of intensity-modulated radiotherapy (IMRT) is important. Objective: To compare long-term prospective outcomes of patients receiving IMRT and 3-dimensional conformal radiotherapy (3D-CRT) with concurrent carboplatin/paclitaxel for locally advanced NSCLC. Design, Setting, and Participants: A secondary analysis of a prospective phase 3 randomized clinical trial NRG Oncology-RTOG 0617 assessed 483 patients receiving chemoradiotherapy (3D-CRT vs IMRT) for locally advanced NSCLC based on stratification. Main Outcomes and Measures: Long-term outcomes were analyzed, including overall survival (OS), progression-free survival (PFS), time to local failure, development of second cancers, and severe grade 3 or higher adverse events (AEs) per Common Terminology Criteria for Adverse Events, version 3. The percentage of an organ volume (V) receiving a specified amount of radiation in units of Gy is reported as V(radiation dose). Results: Of 483 patients (median [IQR] age, 64 [57-70] years; 194 [40.2%] female), 228 (47.2%) received IMRT, and 255 (52.8%) received 3D-CRT (median [IQR] follow-up, 5.2 [4.8-6.0] years). IMRT was associated with a 2-fold reduction in grade 3 or higher pneumonitis AEs compared with 3D-CRT (8 [3.5%] vs 21 [8.2%]; P = .03). On univariate analysis, heart V20, V40, and V60 were associated with worse OS (hazard ratios, 1.06 [95% CI, 1.04-1.09]; 1.09 [95% CI, 1.05-1.13]; 1.16 [95% CI, 1.09-1.24], respectively; all P < .001). IMRT significantly reduced heart V40 compared to 3D-CRT (16.5% vs 20.5%; P < .001). Heart V40 (<20%) had better OS than V40 (≥20%) (median [IQR], 2.5 [2.1-3.1] years vs 1.7 [1.5-2.0] years; P < .001). On multivariable analysis, heart V40 (≥20%), was associated with worse OS (hazard ratio, 1.34 [95% CI, 1.06-1.70]; P = .01), whereas lung V5 and age had no association with OS. Patients receiving IMRT and 3D-CRT had similar rates of developing secondary cancers (15 [6.6%] vs 14 [5.5%]) with long-term follow-up. Conclusions and Relevance: These findings support the standard use of IMRT for locally advanced NSCLC. IMRT should aim to minimize lung V20 and heart V20 to V60, rather than constraining low-dose radiation bath. Lung V5 and age were not associated with survival and should not be considered a contraindication for chemoradiotherapy. Trial Registration: ClinicalTrials.gov Identifier: NCT00533949.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Pessoa de Meia-Idade , Feminino , Masculino , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patologia , Idoso , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/patologia , Estudos Prospectivos , Resultado do Tratamento , Quimiorradioterapia/métodos , Paclitaxel/administração & dosagem , Paclitaxel/uso terapêutico , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos , Carboplatina/administração & dosagem , Carboplatina/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Intervalo Livre de Progressão
7.
J Appl Clin Med Phys ; 25(8): e14394, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38887816

RESUMO

PURPOSE: The treatment of brain tumors in pregnant patients poses challenges, as the out-of-field dose exposure to the fetus can potentially be harmful. A pregnant patient with prior radiation treatment was presented with a brain tumor at our clinic. This work reports on our pre-treatment study that compared fetal dose exposure between intensity-modulated proton therapy (IMPT) using pencil beam scanning (PBS) and conventional photon 3D conformal radiation therapy (3DCRT) and volumetric-modulated arc therapy (VMAT), and the subsequent pregnant patient's radiation treatment. MATERIALS AND METHODS: Pre-treatment measurements of clinical plans, 3DCRT, VMAT, and IMPT, were conducted on a phantom. Measurements were performed using a device capable of neutron detections, closely following AAPM guidelines, TG158. For photon measurements, fetus shielding was utilized. On patient treatment days, which was determined to be proton treatment, shielding was used only during daily imaging for patient setup. Additionally, an in vivo measurement was conducted on the patient. RESULTS: Measurements showed that IMPT delivered the lowest fetal dose, considering both photon and neutron out-of-field doses to the fetus, even when shielding was implemented for photon measurements. Additionally, the proton plans demonstrated superior treatment for the mother, a reirradiation case. CONCLUSION: The patient was treated with proton therapy, and the baby was subsequently delivered at full term with no complications. This case study supports previous clinical findings and advocates for the expanded use of proton therapy in this patient population.


Assuntos
Neoplasias Encefálicas , Feto , Órgãos em Risco , Imagens de Fantasmas , Terapia com Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Gravidez , Feminino , Radioterapia de Intensidade Modulada/métodos , Neoplasias Encefálicas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Terapia com Prótons/métodos , Feto/efeitos da radiação , Órgãos em Risco/efeitos da radiação , Radioterapia Conformacional/métodos , Adulto , Complicações Neoplásicas na Gravidez/radioterapia
8.
Asian Pac J Cancer Prev ; 25(5): 1707-1713, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38809643

RESUMO

BACKGROUND: Radiation-induced lung disease is a potentially fatal, dose-limiting toxicity commonly seen after radiotherapy of thoracic malignancies, including breast cancer. AIM: To evaluate and compare the early lung toxicity induced by 3D-CRT and IMRT radiotherapy treatment modalities in breast cancer female patients using biochemical, dosimetry and clinical data. SUBJECTS AND METHODS: this study included 15 normal healthy controls, 15 breast cancer patients treated with IMRT, and 15 breast cancer patients treated with 3D-CRT. One blood sample was obtained from the control group and 3 blood samples were withdrawn from cases before RT, after RT and after 3 months of RT. RESULT: IMRT delivered higher radiation dose to the breast tumor and lower doses to the lung as an organ at risk. There was a non-significant increase in the serum levels of IL-6 before IMRT and 3D-CRT compared with its levels in the control group. There were significant increases in serum levels of IL-6 after RT (IMRT and 3DCRT) compared with its levels before RT. There was a non-significant decrease in the serum levels of IL-6 after 3 months of RT (IMRT and 3D-CRT) compared with its serum levels immediately after RT. There was a non-significant increase in the serum levels of SP-D before RT (IMRT and 3D-CRT) compared with its levels in the control group. There were significant-increases in serum levels of SP-D after RT (IMRT and 3D-CRT) compared with its levels before RT. There was a non-significant decrease in the serum levels of SP-D after 3 months of radiotherapy (IMRT and 3D-CRT) compared with its serum levels immediately after RT. CONCLUSION: serum of levels IL-6 and SP-D can be used to diagnose the occurrence of early lung toxicity due to radiotherapy and the rate of recovery from radiation pneumonitis is apparent in case of IMRT than 3D-CRT.


Assuntos
Neoplasias da Mama , Interleucina-6 , Proteína D Associada a Surfactante Pulmonar , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada , Humanos , Feminino , Interleucina-6/sangue , Radioterapia de Intensidade Modulada/efeitos adversos , Neoplasias da Mama/radioterapia , Neoplasias da Mama/sangue , Pessoa de Meia-Idade , Proteína D Associada a Surfactante Pulmonar/sangue , Estudos de Casos e Controles , Radioterapia Conformacional/efeitos adversos , Seguimentos , Adulto , Lesões por Radiação/sangue , Lesões por Radiação/etiologia , Prognóstico , Pneumonite por Radiação/etiologia , Pneumonite por Radiação/sangue , Planejamento da Radioterapia Assistida por Computador/métodos , Pulmão/efeitos da radiação , Idoso , Radiometria
9.
J Coll Physicians Surg Pak ; 34(5): 573-577, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38720219

RESUMO

OBJECTIVE:  To compare the acute toxicities of two radiation treatment techniques, intensity modulated radiation therapy (IMRT), and 3-dimensional conformal radiation therapy (3D-CRT) in localised prostate adenocarcinoma. STUDY DESIGN: Descriptive study. Place and Duration of the Study: Department of Oncology, Dr. Ziauddin Hospital, Karachi, Pakistan, from July 2016 to June 2022. METHODOLOGY: Patients with localised prostate adenocarcinoma who underwent treatment using two different advanced radiotherapy techniques i.e., IMRT and 3D-CRT were recruited during the study period. They were followed up for six months for acute gastrointestinal (GI) and genitourinary (GU) adverse events (acute toxicities) related to both treatment modalities according to Modified radiation therapy oncology group (RTOG) criteria. The acute toxicities were assessed at the 2nd, 4th, and 6th week during treatment and at the 3rd and 6th month after treatment. RESULTS:  There were 78 patients, with 39 patients in each group. The mean age was 68 ± 10 years in the 3D-CRT and 68 ± 07 years in the IMRT group. Patients in the IMRT group exhibited markedly lower treatment-related acute GI and GU effects at the end of 4th and 6th weeks for anorectal pain (p = 0.04) and (p = 0.01) and burning micturition (p = 0.003) and (p = 0.01), respectively. Furthermore, at 3 months anorectal pain (p = 0.02), loose stools (p = 0.005), and burning micturition (p = 0.01) were present and at 6 months anorectal pain was (p = 0.01) still present. CONCLUSION: Radiation therapy modalities 3D-CRT and IMRT both showed acceptable toxicity profile in the management of localised prostate cancer, while IMRT group exhibited significantly lower treatment-related acute GI and GU effects. KEY WORDS: 3D-CRT (3-Dimensional Conformal Radiation Therapy), IMRT (Intensity-Modulated Radiation Therapy), Radiation toxicity.


Assuntos
Neoplasias da Próstata , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Idoso , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos , Pessoa de Meia-Idade , Lesões por Radiação/etiologia , Adenocarcinoma/radioterapia , Adenocarcinoma/patologia , Paquistão , Dosagem Radioterapêutica
10.
J Appl Clin Med Phys ; 25(6): e14387, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38778567

RESUMO

INTRODUCTION: Radiation dose measurement is an essential part of radiotherapy to verify the correct delivery of doses to patients and ensure patient safety. Recent advancements in radiotherapy technology have highlighted the need for fast and precise dosimeters. Technologies like FLASH radiotherapy and magnetic-resonance linear accelerators (MR-LINAC) demand dosimeters that can meet their unique requirements. One promising solution is the plastic scintillator-based dosimeter with high spatial resolution and real-time dose output. This study explores the feasibility of using the LuSy dosimeter, an in-house developed plastic scintillator dosimeter for dose verification across various radiotherapy techniques, including conformal radiotherapy (CRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). MATERIALS AND METHODS: A new dosimetry system, comprising a new plastic scintillator as the sensing material, was developed and characterized for radiotherapy beams. Treatment plans were created for conformal radiotherapy, IMRT, VMAT, and SRS and delivered to a phantom. LuSy dosimeter was used to measure the delivered dose for each plan on the surface of the phantom and inside the target volumes. Then, LuSy measurements were compared against an ionization chamber, MOSFET dosimeter, radiochromic films, and dose calculated using the treatment planning system (TPS). RESULTS: For CRT, surface dose measurement by LuSy dosimeter showed a deviation of -5.5% and -5.4% for breast and abdomen treatment from the TPS, respectively. When measuring inside the target volume for IMRT, VMAT, and SRS, the LuSy dosimeter produced a mean deviation of -3.0% from the TPS. Surface dose measurement resulted in higher TPS discrepancies where the deviations for IMRT, VMAT, and SRS were -2.0%, -19.5%, and 16.1%, respectively. CONCLUSION: The LuSy dosimeter was feasible for measuring radiotherapy doses for various treatment techniques. Treatment delivery verification enables early error detection, allowing for safe treatment delivery for radiotherapy patients.


Assuntos
Estudos de Viabilidade , Aceleradores de Partículas , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Aceleradores de Partículas/instrumentação , Radiocirurgia/métodos , Dosímetros de Radiação , Radioterapia Conformacional/métodos , Radioterapia Conformacional/instrumentação , Radiometria/métodos , Radiometria/instrumentação , Órgãos em Risco/efeitos da radiação , Neoplasias/radioterapia
11.
Acta Otorhinolaryngol Ital ; 44(3): 150-160, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38712518

RESUMO

Objective: To perform a dosimetric comparison between intensity modulated radiotherapy (IMRT) and 3D conformal radiotherapy in patients with locally advanced (stage III and IV) tumours of the supraglottic region treated with conservative surgery and post-operative radiotherapy. Methods: An in-silico plan using a 3D conformal shrinking field technique was retrospectively produced for 20 patients and compared with actually delivered IMRT plans. Eighteen structures (arytenoids, constrictor muscles, base of tongue, floor of mouth, pharyngeal axis, oral cavity, submandibular glands and muscles of the swallowing functional units [SFU]) were considered. Results: IMRT allowed a reduction of maximum and mean doses to 9 and 14 structures, respectively (p < .05). Conclusions: IMRT achieved a reduction of unnecessary dose to the remnant larynx and the majority of surrounding SFUs. Further prospective analyses and correlations with functional clinical outcomes are required to confirm these dosimetric findings.


Assuntos
Neoplasias Laríngeas , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Neoplasias Laríngeas/radioterapia , Neoplasias Laríngeas/cirurgia , Radioterapia Conformacional/métodos , Masculino , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Idoso , Dosagem Radioterapêutica , Adulto , Cuidados Pós-Operatórios/métodos
12.
Med Phys ; 51(7): 5081-5093, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38597815

RESUMO

BACKGROUND: Cyclotron-based proton therapy systems utilize the highest proton energies to achieve an ultra-high dose rate (UHDR) for FLASH radiotherapy. The deep-penetrating range associated with this high energy can be modulated by inserting a uniform plate of proton-stopping material, known as a range shifter, in the beam path at the nozzle to bring the Bragg peak within the target while ensuring high proton transport efficiency for UHDR. Aluminum has been recently proposed as a range shifter material mainly due to its high compactness and its mechanical properties. A possible drawback lies in the fact that aluminum has a larger cross-section of producing secondary neutrons compared to conventional plastic range shifters. Accordingly, an increase in secondary neutron contamination was expected during the delivery of range-modulated FLASH proton therapy, potentially heightening neutron-induced carcinogenic risks to the patient. PURPOSE: We conducted neutron dosimetry using simulations and measurements to evaluate excess dose due to neutron exposure during UHDR proton irradiation with aluminum range shifters compared to plastic range shifters. METHODS: Monte Carlo simulations in TOPAS were performed to investigate the secondary neutron production characteristics with aluminum range shifter during 225 MeV single-spot proton irradiation. The computational results were validated against measurements with a pair of ionization chambers in an out-of-field region ( ≤ $\le$ 30 cm) and with a Proton Recoil Scintillator-Los Alamos rem meter in a far-out-of-field region (0.5-2.5 m). The assessments were repeated with solid water slabs as a surrogate for the conventional range shifter material to evaluate the impact of aluminum on neutron yield. The results were compared with the International Electrotechnical Commission (IEC) standards to evaluate the clinical acceptance of the secondary neutron yield. RESULTS: For a range modulation up to 26 cm in water, the maximum simulated and measured values of out-of-field secondary neutron dose equivalent per therapeutic dose with aluminum range shifter were found to be ( 0.57 ± 0.02 ) mSv/Gy $(0.57\pm 0.02)\ \text{mSv/Gy}$ and ( 0.46 ± 0.04 ) mSv/Gy $(0.46\pm 0.04)\ \text{mSv/Gy}$ , respectively, overall higher than the solid water cases (simulation: ( 0.332 ± 0.003 ) mSv/Gy $(0.332\pm 0.003)\ \text{mSv/Gy}$ ; measurement: ( 0.33 ± 0.03 ) mSv/Gy $(0.33\pm 0.03)\ \text{mSv/Gy}$ ). The maximum far out-of-field secondary neutron dose equivalent was found to be ( 8.8 ± 0.5 $8.8 \pm 0.5$ )  µ Sv / Gy $\umu {\rm Sv/Gy}$ and ( 1.62 ± 0.02 $1.62 \pm 0.02$ )  µ Sv / Gy $\umu {\rm Sv/Gy}$ for the simulations and rem meter measurements, respectively, also higher than the solid water counterparts (simulation: ( 3.3 ± 0.3 $3.3 \pm 0.3$ )  µ Sv / Gy $\umu {\rm Sv/Gy}$ ; measurement: ( 0.63 ± 0.03 $0.63 \pm 0.03$ )  µ Sv / Gy $\umu {\rm Sv/Gy}$ ). CONCLUSIONS: We conducted simulations and measurements of secondary neutron production under proton irradiation at FLASH energy with range shifters. We found that the secondary neutron yield increased when using aluminum range shifters compared to conventional materials while remaining well below the non-primary radiation limit constrained by the IEC regulations.


Assuntos
Método de Monte Carlo , Nêutrons , Terapia com Prótons , Radiometria , Terapia com Prótons/instrumentação , Radiometria/instrumentação , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/métodos , Alumínio/química , Dosagem Radioterapêutica , Humanos
13.
Int J Radiat Oncol Biol Phys ; 120(2): 332-342, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38583494

RESUMO

PURPOSE: There is limited clinical data for recommendations on how to deliver thoracic radiation therapy (TRT) concurrently with chemotherapy in limited-stage small cell lung cancer. We reviewed radiation therapy treatment plans in a randomized phase 2 trial comparing high-dose with standard-dose twice-daily TRT to assess treatment planning techniques, dose-volume data for target volumes and organs at risk (OARs), evaluate compliance with the protocol, associations with radiation-induced toxicity, and whether an imbalance in treatment planning parameters might be a reason for the large survival benefit of the higher dose (median overall survival 43.6 vs 22.6 months). METHODS AND MATERIALS: In the study, 170 patients were to receive 4 courses of platinum/etoposide and were randomized to receive twice-daily TRT of 60 Gy/40 fractions (fx) or 45 Gy/30 fx. TRT treatment plans for those who received 1 or more fx of TRT (n = 166) were analyzed. RESULTS: The most common treatment planning technique was 3-dimensional conformal radiation therapy (67%). The 75th percentile of the reported dose-volume parameters for the OARs were within the protocol-recommended limits for both groups. Mean doses to the esophagus of 25.5 Gy (IQR, 20.2-31.3; 60 Gy/40 fx) and 24.3 Gy (IQR, 20.3-27.5; 45 Gy/30 fx) were associated with 21% and 18% ≥ grade 3 acute esophagitis, respectively. In the 60 Gy/40 fx group, a mean dose to the lungs of 16.5 Gy (IQR, 15.8-16.9), V20 Gy of 29.5% (IQR, 28.8-30.4), and V5 Gy of 65.6% (IQR, 61.5-68.7) led to ≥ grade 3 pneumonitis in 4% of the patients. There was no ≥ grade 3 pneumonitis in the 45 Gy/30 fx group. The treatment planning techniques, the percentage change in volumes between original and redelineated OARs, planning target volumes, relative doses, and laterality were well balanced between the randomly assigned groups. CONCLUSIONS: Considering the incidences of severe radiation-induced toxicities were within the range of other recent trials, the reported doses to the OARs appear to be safe. Treatment planning parameters were well balanced between the randomly assigned groups, supporting that the survival benefit of the twice-daily 60 Gy/40 fx TRT schedule was due to the higher dose.


Assuntos
Fracionamento da Dose de Radiação , Etoposídeo , Neoplasias Pulmonares , Órgãos em Risco , Planejamento da Radioterapia Assistida por Computador , Carcinoma de Pequenas Células do Pulmão , Humanos , Carcinoma de Pequenas Células do Pulmão/radioterapia , Carcinoma de Pequenas Células do Pulmão/patologia , Carcinoma de Pequenas Células do Pulmão/tratamento farmacológico , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patologia , Masculino , Órgãos em Risco/efeitos da radiação , Feminino , Idoso , Pessoa de Meia-Idade , Etoposídeo/administração & dosagem , Radioterapia Conformacional/métodos , Radioterapia Conformacional/efeitos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Dosagem Radioterapêutica , Pneumonite por Radiação/etiologia , Idoso de 80 Anos ou mais , Esôfago/efeitos da radiação , Adulto
14.
Radiat Oncol ; 19(1): 49, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627747

RESUMO

OBJECTIVE: This study evaluates various craniospinal irradiation (CSI) techniques used in Turkish centers to understand their advantages, disadvantages and overall effectiveness, with a focus on enhancing dose distribution. METHODS: Anonymized CT scans of adult and pediatric patients, alongside target volumes and organ-at-risk (OAR) structures, were shared with 25 local radiotherapy centers. They were tasked to develop optimal treatment plans delivering 36 Gy in 20 fractions with 95% PTV coverage, while minimizing OAR exposure. The same CT data was sent to a US proton therapy center for comparison. Various planning systems and treatment techniques (3D conformal RT, IMRT, VMAT, tomotherapy) were utilized. Elekta Proknow software was used to analyze parameters, assess dose distributions, mean doses, conformity index (CI), and homogeneity index (HI) for both target volumes and OARs. Comparisons were made against proton therapy. RESULTS: All techniques consistently achieved excellent PTV coverage (V95 > 98%) for both adult and pediatric patients. Tomotherapy closely approached ideal Dmean doses for all PTVs, while 3D-CRT had higher Dmean for PTV_brain. Tomotherapy excelled in CI and HI for PTVs. IMRT resulted in lower pediatric heart, kidney, parotid, and eye doses, while 3D-CRT achieved the lowest adult lung doses. Tomotherapy approached proton therapy doses for adult kidneys and thyroid, while IMRT excelled for adult heart, kidney, parotid, esophagus, and eyes. CONCLUSION: Modern radiotherapy techniques offer improved target coverage and OAR protection. However, 3D techniques are continued to be used for CSI. Notably, proton therapy stands out as the most efficient approach, closely followed by Tomotherapy in terms of achieving superior target coverage and OAR protection.


Assuntos
Radiação Cranioespinal , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Adulto , Humanos , Criança , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radiação Cranioespinal/métodos , Turquia , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos
15.
Appl Radiat Isot ; 209: 111322, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38642442

RESUMO

Dose conformity is an essential parameter used in radiotherapy and radiosurgery that measures the correspondence of the dose distribution derived from a Treatment Planning System (TPS) with the actual volume to be treated, the Planning Treatment Volume (PTV). The present work uses a method based on the expansion of dose distributions and PTVs by three-dimensional Zernike polynomials and further comparison of their moments to define a general criterion of dose conformity. To carry on this study, data coming from 20 patients comprising 80 datasets exported from the TPS, which included imaging data (PTVs) and dose distributions corresponding to different treatment modalities: three-dimensional conformal radiotherapy, intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT), were used. The expansions in Zernike polynomials were obtained up to order 6 and reconstructed dose distributions and PTVs were obtained and compared, and several definitions for a general dose conformity index were proposed. Results indicate agreement between the proposed dose conformity index and the Conformation Number CN. The proposed method allows for a systematic approach to the analysis of dose distributions with further extensions in AI applications.


Assuntos
Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Radioterapia Conformacional/métodos , Algoritmos
16.
Asian Pac J Cancer Prev ; 25(4): 1451-1456, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38680007

RESUMO

OBJECTIVE: To identify swallowing-related structures (SRSs) predicting post-radiotherapy dysphagia in oropharyngeal carcinoma patients. MATERIAL AND METHODS: Between September 2020 and October 2022, oropharyngeal cancer patients who had completed radiotherapy at least one year before without recurrence or residuals were selected. They underwent flexible endoscopic evaluation of swallowing (FEES) assessments and dysphagia grading. The mean radiation doses delivered to their SRSs were recalculated. The correlation between radiation doses to each SRS and FEES scores was analysed. RESULTS: Twenty-nine participants, aged 51-73 years, were enrolled. Six patients had received two-dimensional radiotherapy, eight had undergone three-dimensional conformal radiotherapy, and fifteen had received intensity-modulated radiation therapy. Radiation doses to the inferior pharyngeal constrictor, cricopharyngeus and glottic larynx significantly predicted dysphagia for both semisolids (p = 0.023, 0.030 and 0.001) and liquid diets (p = 0.021, 0.013 and 0.002). The esophageal inlet significantly predicted swallowing outcomes for only the liquid diet (p = 0.007). CONCLUSIONS: This study supports that SRS-sparing during radiotherapy for oropharyngeal cancers improves swallowing outcomes.


Assuntos
Transtornos de Deglutição , Neoplasias Orofaríngeas , Humanos , Transtornos de Deglutição/etiologia , Transtornos de Deglutição/radioterapia , Pessoa de Meia-Idade , Masculino , Neoplasias Orofaríngeas/radioterapia , Neoplasias Orofaríngeas/complicações , Feminino , Idoso , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Seguimentos , Prognóstico , Deglutição , Lesões por Radiação/etiologia , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos , Dosagem Radioterapêutica , Tratamentos com Preservação do Órgão/métodos
17.
Int J Radiat Oncol Biol Phys ; 119(5): 1386-1390, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38521132

RESUMO

PURPOSE: CONVERT was a phase 3 international randomized clinical trial comparing once-daily (OD) and twice-daily (BD) radiation therapy (RT). This updated analysis describes the 6.5-year outcomes of these regimens delivered with conformal techniques. METHODS AND MATERIALS: CONVERT (NCT00433563) randomized patients 1:1 between OD RT (66 Gy/33 fractions/6.5 weeks) and BD RT (45 Gy/30 fractions/3 weeks), both delivered with concurrent cisplatin/etoposide. Three-dimensional conformal RT was mandatory, intensity-modulated RT was permitted, and elective nodal irradiation was not allowed. Prophylactic cranial irradiation was delivered at the discretion of treating clinicians. RT treatment planning was subject to central quality assurance. RESULTS: Five hundred forty-seven patients were recruited at 73 centers. The median follow-up for the surviving cohort (n = 164) was 81.2 months. The median survival for the OD and BD arms were 25.4 months (95% CI, 21.1-30.9) and 30.0 months (95% CI, 25.3-36.5; hazard ratio, 1.13; 95% CI, 0.92-1.38; P = .247). Performance status and tumor volume were associated with survival on multivariate analysis. No treatment-related deaths occurred subsequent to the initial analysis performed in 2017. Regarding late toxicity, 7 patients in the OD arm developed grade 3 esophagitis, 4 of which went on to develop stricture or fistulation, compared with no patients in the BD arm. Grade 3 pulmonary fibrosis occurred in 2 and 3 patients in the OD and BD arms, respectively. CONCLUSIONS: As the CONVERT trial did not demonstrate the superiority of OD RT and this regimen had a slightly worse toxicity profile after 80 months of follow-up, 45 Gy BD should remain the standard of care in limited stage small cell lung cancer.


Assuntos
Quimiorradioterapia , Cisplatino , Etoposídeo , Neoplasias Pulmonares , Radioterapia Conformacional , Carcinoma de Pequenas Células do Pulmão , Humanos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/terapia , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/mortalidade , Quimiorradioterapia/efeitos adversos , Quimiorradioterapia/métodos , Carcinoma de Pequenas Células do Pulmão/radioterapia , Carcinoma de Pequenas Células do Pulmão/patologia , Carcinoma de Pequenas Células do Pulmão/terapia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Etoposídeo/administração & dosagem , Cisplatino/administração & dosagem , Radioterapia Conformacional/métodos , Radioterapia Conformacional/efeitos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Fracionamento da Dose de Radiação , Resultado do Tratamento , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Adulto , Fatores de Tempo , Irradiação Craniana/efeitos adversos , Irradiação Craniana/métodos
18.
J Med Imaging Radiat Sci ; 55(2): 221-231, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38429174

RESUMO

BACKGROUND: Patients treated for lung cancer (LC) often experience locoregional failure after initial treatment. Due to technological advances, thoracic reirradiation (re-RT) has become a viable treatment option. We sought to investigate the use of thoracic re-RT in LC patients over a time period characterized by technological advances in a large, multi-center cohort. METHODS AND MATERIALS: LC patients treated with thoracic re-RT in two University Hospitals from 2010-2020 were identified. Clinical variables and RT data were extracted from the medical records and treatment planning systems. Overall survival (OS) was calculated from the last day of re-RT until death or last follow up. RESULTS: 296 patients (small cell LC n=30, non-small cell LC n=266) were included. Three-dimensional conformal radiation therapy was the RT technique used most frequently (63%), and 86% of all patients were referred for re-RT with palliative treatment intent. During the second half of the study period, the use of thoracic re-RT increased in general, more patients received curative re-RT, and there was an increased use of stereotactic body radiation therapy (SBRT). Median time between initial RT and re-RT was 18 months (range 1-213 months). Only 83/296 patients had combined treatment plans that allowed for registration of combined doses to organs at risk (OAR). Most of the combined doses to OAR were below recommendations from guidelines. Multivariate analysis showed superior OS (p<0.05) in patients treated with curative intent, SBRT or intensity modulated radiation therapy or had excellent performance status prior to re-RT. CONCLUSIONS: The use of re-RT increased in the second half of the study period, although 2020 did not follow the trend. The use of SBRT and IMRT became more frequent over the years, yet the majority received palliative re-RT. Combined dose plans were only created for one third of the patients.


Assuntos
Neoplasias Pulmonares , Reirradiação , Humanos , Neoplasias Pulmonares/radioterapia , Feminino , Reirradiação/métodos , Masculino , Idoso , Pessoa de Meia-Idade , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Estudos Retrospectivos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Radioterapia Conformacional/métodos
19.
Radiother Oncol ; 195: 110258, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38537680

RESUMO

This systematic review examines the role of dosimetric parameters in predicting temporal lobe necrosis (TLN) risk in nasopharyngeal carcinoma (NPC) patients treated with three-dimensional conformal RT (3D-CRT), intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). TLN is a serious late complication that can adversely affect the quality of life of NPC patients. Understanding the relationship between dosimetric parameters and TLN can guide treatment planning and minimize radiation-related complications. A comprehensive search identified relevant studies published up to July 2023. Studies reporting on dosimetric parameters and TLN in NPC patients undergoing 3D-CRT, IMRT, and VMAT were included. TLN incidence, follow-up duration, and correlation with dosimetric parameters of the temporal lobe were analyzed. The review included 30 studies with median follow-up durations ranging from 28 to 110 months. The crude incidence of TLN varied from 2.3 % to 47.3 % and the average crude incidence of TLN is approximately 14 %. Dmax and D1cc emerged as potential predictors of TLN in 3D-CRT and IMRT-treated NPC patients. Threshold values of >72 Gy for Dmax and >62 Gy for D1cc were associated with increased TLN risk. However, other factors should also be considered, including host characteristics, tumor-specific features and therapeutic factors. In conclusion, this systematic review highlights the significance of dosimetric parameters, particularly Dmax and D1cc, in predicting TLN risk in NPC patients undergoing 3D-CRT, IMRT, and VMAT. The findings provide valuable insights that can help in developing optimal treatment planning strategies and contribute to the development of clinical guidelines in this field.


Assuntos
Carcinoma Nasofaríngeo , Neoplasias Nasofaríngeas , Necrose , Lesões por Radiação , Radioterapia de Intensidade Modulada , Lobo Temporal , Humanos , Carcinoma Nasofaríngeo/radioterapia , Carcinoma Nasofaríngeo/patologia , Lobo Temporal/efeitos da radiação , Lobo Temporal/patologia , Necrose/etiologia , Lesões por Radiação/etiologia , Lesões por Radiação/patologia , Neoplasias Nasofaríngeas/radioterapia , Neoplasias Nasofaríngeas/patologia , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos
20.
Sci Rep ; 14(1): 7134, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532018

RESUMO

We aimed to investigate the deliverability of dynamic conformal arc therapy (DCAT) by gantry wobble owing to the intrinsic inter-segment break of the Elekta linear accelerator (LINAC) and its adverse influence on the dose to the patient. The deliverability of DCAT was evaluated according to the plan parameters, which affect the gantry rotation speed and resultant positional inaccuracies; the deliverability according to the number of control points and dose rates was investigated by using treatment machine log files and dosimetry devices, respectively. A non-negligible degradation in DCAT deliverability due to gantry wobble was observed in both the treatment machine log files and dosimetry devices. The resulting dose-delivery error occurred below a certain number of control points or above a certain dose rate. Dose simulations in the patient domain showed a similar impact on deteriorated deliverability. For targets located primarily in the isocenter, the dose differences were negligible, whereas for organs at risk located mainly off-isocenter, the dose differences were significant up to - 8.77%. To ensure safe and accurate radiotherapy, optimal plan parameters should be selected, and gantry angle-specific validations should be conducted before treatment.


Assuntos
Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Aceleradores de Partículas , Radiometria/métodos , Radioterapia de Intensidade Modulada/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...