Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.594
Filtrar
1.
Phys Med Biol ; 69(14)2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38979700

RESUMO

Objective.In helical tomotherapy, image-guided radiotherapy employs megavoltage computed tomography (MVCT) for precise targeting. However, the high voltage of megavoltage radiation introduces substantial noise, significantly compromising MVCT image clarity. This study aims to enhance MVCT image quality using a deep learning-based denoising method.Approach.We propose an unpaired MVCT denoising network using a coupled generative adversarial network framework (DeCoGAN). Our approach assumes that a universal latent code within a shared latent space can reconstruct any given pair of images. By employing an encoder, we enforce this shared-latent space constraint, facilitating the conversion of low-quality (noisy) MVCT images into high-quality (denoised) counterparts. The network learns the joint distribution of images from both domains by leveraging samples from their respective marginal distributions, enhanced by adversarial training for effective denoising.Main Results.Compared to an analytical algorithm (BM3D) and three deep learning-based methods (RED-CNN, WGAN-VGG and CycleGAN), the proposed method excels in preserving image details and enhancing human visual perception by removing most noise and retaining structural features. Quantitative analysis demonstrates that our method achieves the highest peak signal-to-noise ratio and Structural Similarity Index Measurement values, indicating superior denoising performance.Significance.The proposed DeCoGAN method shows remarkable MVCT denoising performance, making it a promising tool in the field of radiation therapy.


Assuntos
Processamento de Imagem Assistida por Computador , Razão Sinal-Ruído , Processamento de Imagem Assistida por Computador/métodos , Humanos , Tomografia Computadorizada por Raios X , Aprendizado Profundo , Radioterapia Guiada por Imagem/métodos , Redes Neurais de Computação
2.
Phys Med Biol ; 69(15)2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-38959907

RESUMO

Objective.This study aims to develop a fully automatic planning framework for functional lung avoidance radiotherapy (AP-FLART).Approach.The AP-FLART integrates a dosimetric score-based beam angle selection method and a meta-optimization-based plan optimization method, both of which incorporate lung function information to guide dose redirection from high functional lung (HFL) to low functional lung (LFL). It is applicable to both contour-based FLART (cFLART) and voxel-based FLART (vFLART) optimization options. A cohort of 18 lung cancer patient cases underwent planning-CT and SPECT perfusion scans were collected. AP-FLART was applied to generate conventional RT (ConvRT), cFLART, and vFLART plans for all cases. We compared automatic against manual ConvRT plans as well as automatic ConvRT against FLART plans, to evaluate the effectiveness of AP-FLART. Ablation studies were performed to evaluate the contribution of function-guided beam angle selection and plan optimization to dose redirection.Main results.Automatic ConvRT plans generated by AP-FLART exhibited similar quality compared to manual counterparts. Furthermore, compared to automatic ConvRT plans, HFL mean dose,V20, andV5were significantly reduced by 1.13 Gy (p< .001), 2.01% (p< .001), and 6.66% (p< .001) respectively for cFLART plans. Besides, vFLART plans showed a decrease in lung functionally weighted mean dose by 0.64 Gy (p< .01),fV20by 0.90% (p= 0.099), andfV5by 5.07% (p< .01) respectively. Though inferior conformity was observed, all dose constraints were well satisfied. The ablation study results indicated that both function-guided beam angle selection and plan optimization significantly contributed to dose redirection.Significance.AP-FLART can effectively redirect doses from HFL to LFL without severely degrading conventional dose metrics, producing high-quality FLART plans. It has the potential to advance the research and clinical application of FLART by providing labor-free, consistent, and high-quality plans.


Assuntos
Automação , Neoplasias Pulmonares , Planejamento da Radioterapia Assistida por Computador , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Dosagem Radioterapêutica , Pulmão/efeitos da radiação , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Radioterapia Guiada por Imagem/métodos
3.
Magy Onkol ; 68(2): 155-162, 2024 Jul 16.
Artigo em Húngaro | MEDLINE | ID: mdl-39013089

RESUMO

In the Radiotherapy Centre of the National Institute of Oncology, Budapest, a 0.55 T MR scanner (MAGNETOM Free. Max) and a ring-like X-ray machine (ImagingRing) have been in operation since 2022. The MR scanner has a tunnel diameter of 80 cm, the X-ray machine has a ring diameter of 121 cm. The latter can also be used for cone-beam CT (CBCT) imaging. The MR scanner is mainly used for planning gynaecological brachytherapy (BT) treatments. Image distortions in MR imaging were investigated with a special grid phantom. After head and neck and breast implant, image quality of ImagingRing CBCT and planning CT was compared. The position of the radiation source was verified by radiographs taken during treatment. Despite the lower field strength, the image quality of the MR scanner was found to be adequate for treatment planning of gynaecological BT. Image distortions were found to be clinically negligible. On CBCT images obtained with ImagingRing, catheters could always be well identified, and anatomical organs were adequately visualized for head and neck treatments, but not for breast implants. The MR scanner is suitable for treatment planning for gynaecological BT due to its good image quality and low image distortion. The image quality of the ImagingRing is suitable for treatment planning for small body sizes, but not for larger sizes. The device can be used to in vivo check of the radiation source position during treatment.


Assuntos
Braquiterapia , Tomografia Computadorizada de Feixe Cônico , Imageamento por Ressonância Magnética , Planejamento da Radioterapia Assistida por Computador , Humanos , Braquiterapia/métodos , Braquiterapia/instrumentação , Feminino , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias dos Genitais Femininos/radioterapia , Neoplasias dos Genitais Femininos/diagnóstico por imagem , Imagens de Fantasmas , Neoplasias da Mama/radioterapia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Hungria , Radioterapia Guiada por Imagem/métodos , Dosagem Radioterapêutica , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Implantes de Mama
4.
Biomed Phys Eng Express ; 10(4)2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38861951

RESUMO

Objective.We aim to: (1) quantify the benefits of lung sparing using non-adaptive magnetic resonance guided stereotactic body radiotherapy (MRgSBRT) with advanced motion management for peripheral lung cancers compared to conventional x-ray guided SBRT (ConvSBRT); (2) establish a practical decision-making guidance metric to assist a clinician in selecting the appropriate treatment modality.Approach.Eleven patients with peripheral lung cancer who underwent breath-hold, gated MRgSBRT on an MR-guided linear accelerator (MR linac) were studied. Four-dimensional computed tomography (4DCT)-based retrospective planning using an internal target volume (ITV) was performed to simulate ConvSBRT, which were evaluated against the original MRgSBRT plans. Metrics analyzed included planning target volume (PTV) coverage, various lung metrics and the generalized equivalent unform dose (gEUD). A dosimetric predictor for achievable lung metrics was derived to assist future patient triage across modalities.Main results.PTV coverage was high (median V100% > 98%) and comparable for both modalities. MRgSBRT had significantly lower lung doses as measured by V20 (median 3.2% versus 4.2%), mean lung dose (median 3.3 Gy versus 3.8 Gy) and gEUD. Breath-hold, gated MRgSBRT resulted in an average reduction of 47% in PTV volume and an average increase of 19% in lung volume. Strong correlation existed between lung metrics and the ratio of PTV to lung volumes (RPTV/Lungs) for both modalities, indicating that RPTV/Lungsmay serve as a good predictor for achievable lung metrics without the need for pre-planning. A threshold value of RPTV/Lungs< 0.035 is suggested to achieve V20 < 10% using ConvSBRT. MRgSBRT should otherwise be considered if the threshold cannot be met.Significance.The benefits of lung sparing using MRgSBRT were quantified for peripheral lung tumors; RPTV/Lungswas found to be an effective predictor for achievable lung metrics across modalities. RPTV/Lungscan assist a clinician in selecting the appropriate modality without the need for labor-intensive pre-planning, which has significant practical benefit for a busy clinic.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares , Pulmão , Imageamento por Ressonância Magnética , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Humanos , Radiocirurgia/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada Quadridimensional/métodos , Masculino , Feminino , Radioterapia Guiada por Imagem/métodos , Suspensão da Respiração , Idoso , Pessoa de Meia-Idade , Tratamentos com Preservação do Órgão/métodos , Órgãos em Risco
5.
Radiat Oncol ; 19(1): 80, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38918828

RESUMO

INTRODUCTION: Magnetic resonance guided radiotherapy (MRgRT) allows daily adaptation of treatment plans to compensate for positional changes of target volumes and organs at risk (OARs). However, current adaptation times are relatively long and organ movement occurring during the adaptation process might offset the benefit gained by adaptation. The aim of this study was to evaluate the dosimetric impact of these intrafractional changes. Additionally, a method to predict the extent of organ movement before the first treatment was evaluated in order to have the possibility to compensate for them, for example by adding additional margins to OARs. MATERIALS & METHODS: Twenty patients receiving adaptive MRgRT for treatment of abdominal lesions were retrospectively analyzed. Magnetic resonance (MR) images acquired at the start of adaptation and immediately before irradiation were used to calculate adapted and pre-irradiation dose in OARs directly next to the planning target volume. The extent of organ movement was determined on MR images acquired during simulation sessions and adaptive treatments, and their agreement was evaluated. Correlation between the magnitude of organ movement during simulation and the duration of simulation session was analyzed in order to assess whether organ movement might be relevant even if the adaptation process could be accelerated in the future. RESULTS: A significant increase in dose constraint violations was observed from adapted (6.9%) to pre-irradiation (30.2%) dose distributions. Overall, OAR dose increased significantly by 4.3% due to intrafractional organ movement. Median changes in organ position of 7.5 mm (range 1.5-10.5 mm) were detected within a median time of 17.1 min (range 1.6-28.7 min). Good agreement was found between the range of organ movement during simulation and adaptation (66.8%), especially if simulation sessions were longer and multiple MR images were acquired. No correlation was determined between duration of simulation sessions and magnitude of organ movement. CONCLUSION: Intrafractional organ movement can impact dose distributions and lead to violations of OAR tolerance doses, which impairs the benefit of daily on-table plan adaptation. By application of simulation images, the extent of intrafractional organ movement can be predicted, which possibly allows to compensate for them.


Assuntos
Imageamento por Ressonância Magnética , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Humanos , Radioterapia Guiada por Imagem/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos , Órgãos em Risco/efeitos da radiação , Imageamento por Ressonância Magnética/métodos , Neoplasias Abdominais/radioterapia , Neoplasias Abdominais/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Radioterapia de Intensidade Modulada/métodos , Movimento , Fracionamento da Dose de Radiação
6.
Radiat Oncol ; 19(1): 79, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38915062

RESUMO

BACKGROUND: Superficial soft tissue metastasis (S-STM) of malignant tumors is uncommon and often brings great pain to patients. However, current treatment options are limited. The purpose of this study was to explore the clinical efficacy and prognostic factors of CT-guided radioactive iodine-125 (125I) seed implantation (RISI) for the treatment of S-STM. METHODS: We retrospectively evaluated 132 patients with S-STM who received RISI between June 2010 and July 2022. Local tumor progression-free survival (ltPFS), tumor response, pain control and complication were analyzed. The independent factors affecting ltPFS were screened out using a layered Cox proportional hazards model. RESULTS: The median follow-up time was 8.3 months (interquartile range [IQR], 4.5-15.3 months). The objective response rate (ORR) was 81.8%. The median ltPFS was 9.1 (95% CI: 6.6, 11.6) months. The Cox proportional hazard regression model revealed that the independent factors influencing ltPFS included KPS score, primary tumor, metastases, boundary, density and postoperative D90 (All P < 0.05). After RISI, the rate of pain relief was 92.3%. 66 (84.6%) patients reported pain marked relief, and 6 (7.7%) experienced pain moderate relief. No severe adverse events associated with RISI were observed during follow-up. CONCLUSIONS: CT-guided RISI was associated with high local control and pain relief without severe adverse events and should be considered as a reliable palliative treatment modality for S-STM. TRIAL REGISTRATION: Trial registration Retrospectively registered.


Assuntos
Braquiterapia , Radioisótopos do Iodo , Neoplasias de Tecidos Moles , Tomografia Computadorizada por Raios X , Humanos , Radioisótopos do Iodo/uso terapêutico , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Neoplasias de Tecidos Moles/radioterapia , Neoplasias de Tecidos Moles/secundário , Neoplasias de Tecidos Moles/patologia , Prognóstico , Braquiterapia/métodos , Idoso , Adulto , Radioterapia Guiada por Imagem/métodos
7.
Radiat Oncol ; 19(1): 77, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38909242

RESUMO

BACKGROUND: Volumetric modulated arc therapy (VMAT) is a novel form of IMRT, which can deliver more accurate dose distribution and shorten treatment time. Compared to MRI-guided adaptive brachytherapy, which is recommended as gold standard imaging for cervical cancer contours, CT-guided adaptive brachytherapy (CTGAB) is more available, more widespread, and more affordable in many centers. This study aims to retrospectively analyze the efficacy and the safety of VMAT combined with CTGAB for patients with locally advanced cervical cancer. METHODS AND MATERIALS: This study retrospectively analyzed 102 patients with locally advanced cervical cancer who underwent VMAT and CTGAB. Clinical outcomes including local control (LC), overall survival (OS) and progression-free survival (PFS), tumor response to treatment evaluated by the Response Evaluation Criteria in Solid Tumors (RECIST) (version 1.1), and toxicities including gastrointestinal toxicity, urinary toxicity and hematologic toxicity evaluated by the Common Terminology Criteria for Adverse Events (CTCAE) (version 5.0) were analyzed. The Kaplan-Meier method was used to calculate LC, OS, and PFS. RESULTS: Median follow-up time was 19 months. Complete response (CR), partial response (PR), stable disease (SD), and progressive disease (PD) occurred in 68 (66.7%), 24 (23.5%), 4 (3.92%), and 6 (5.88%), respectively. The 2-year and 3-year OS were 89.6% and 83%, respectively. The 2-year and 3-year PFS were 84.2% and 74.3%, respectively. The 2-year and 3-year LC were 90.1% and 79.3%, respectively. The average cumulative D2cm3 in the rectum, the bladder, the colon, and the small intestine were 78.07 (SD: 0.46) Gy, 93.20 (SD: 0.63) Gy, 63.55 (SD: 1.03) Gy and 61.07 (SD: 0.75) Gy, respectively. The average cumulative D90% of the high-risk clinical target volume (HR-CTV) was 92.26 (SD: 0.35) Gy. Grade ≥ 3 gastrointestinal and urinary toxicities occurred in 4.9% and 0.98%, respectively. 1.96% of patients were observed grade ≥ 4 gastrointestinal toxicities and none of the patients observed grade ≥ 4 urinary toxicities. CONCLUSION: VMAT combined with CTGAB for locally advanced cervical cancer was an effective and safe treatment method, which showed satisfactory LC, OS, PFS, and acceptable toxicities.


Assuntos
Braquiterapia , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero , Humanos , Feminino , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/mortalidade , Radioterapia de Intensidade Modulada/métodos , Radioterapia de Intensidade Modulada/efeitos adversos , Braquiterapia/métodos , Braquiterapia/efeitos adversos , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto , Idoso , Radioterapia Guiada por Imagem/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Idoso de 80 Anos ou mais , Taxa de Sobrevida
8.
Phys Med ; 123: 103407, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38906046

RESUMO

PURPOSE: To investigate the current practice patterns in image-guided particle therapy (IGPT) for cranio-spinal irradiation (CSI). METHODS: A multi-institutional survey was distributed to European particle therapy centres to analyse all aspects of IGPT. Based on the survey results, a Delphi consensus analysis was developed to define minimum requirements and optimal workflow for clinical practice. The centres participating in the institutional survey were invited to join the Delphi process. RESULTS: Eleven centres participated in the survey. Imaging for treatment planning was rather similar among the centres with Computed Tomography (CT) being the main modality. For positioning verification, 2D IGPT was more commonly used than 3D IGPT. Two centres performed routinely imaging for plan adaptation, by the rest ad hoc. Eight centres participated in the Delphi consensus analysis. The full consensus was reached on the use of CT imaging without contrast for treatment planning and the role of magnetic resonance imaging (MRI) in target and organs-at-risk delineation. There was an agreement on the necessity to perform patient position verification and correction before each isocentre. The most important outcome was the clear need for standardization and harmonization of the workflow. CONCLUSION: There were differences in CSI IGPT clinical practice among the European particle therapy centres. Moreover, the optimal workflow as identified by experts was not yet reached. There is a strong need for consensus guidelines. The state-of-the-art imaging technology and protocols need to be implemented into clinical practice to improve the quality of IGPT for CSI.


Assuntos
Radioterapia Guiada por Imagem , Humanos , Radioterapia Guiada por Imagem/métodos , Europa (Continente) , Radiação Cranioespinal/métodos , Inquéritos e Questionários , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Técnica Delphi , Imageamento por Ressonância Magnética
9.
Clin Oncol (R Coll Radiol) ; 36(8): 514-526, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38937188

RESUMO

The ability to visualise cancer with imaging has been crucial to the evolution of modern radiotherapy (RT) planning and delivery. And as evolving RT technologies deliver increasingly precise treatment, the importance of accurate identification and delineation of disease assumes ever greater significance. However, innovation in imaging technology has matched that seen with RT delivery platforms, and novel imaging techniques are a focus of much research activity. How these imaging modalities may alter and improve the diagnosis and staging of cancer is an important question, but already well served by the literature. What is less clear is how novel imaging techniques may influence and improve practical and technical aspects of RT planning and delivery. In this review, current gold standard approaches to integration of imaging, and potential future applications of bleeding-edge imaging technology into RT planning pathways are explored.


Assuntos
Neoplasias , Planejamento da Radioterapia Assistida por Computador , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias/radioterapia , Neoplasias/diagnóstico por imagem , Radioterapia Guiada por Imagem/métodos , Diagnóstico por Imagem/métodos
10.
Brachytherapy ; 23(4): 421-432, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38845268

RESUMO

PURPOSE: To investigate geometric and dosimetric inter-observer variability in needle reconstruction for temporary prostate brachytherapy. To assess the potential of registrations between transrectal ultrasound (TRUS) and cone-beam computed tomography (CBCT) to support implant reconstructions. METHODS AND MATERIALS: The needles implanted in 28 patients were reconstructed on TRUS by three physicists. Corresponding geometric deviations and associated dosimetric variations to prostate and organs at risk (urethra, bladder, rectum) were analyzed. To account for the found inter-observer variability, various approaches (template-based, probe-based, marker-based) for registrations of CBCT to TRUS were investigated regarding the respective needle transfer accuracy in a phantom study. Three patient cases were examined to assess registration accuracy in-vivo. RESULTS: Geometric inter-observer deviations >1 mm and >3 mm were found for 34.9% and 3.5% of all needles, respectively. Prostate dose coverage (changes up to 7.2%) and urethra dose (partly exceeding given dose constraints) were most affected by associated dosimetric changes. Marker-based and probe-based registrations resulted in the phantom study in high mean needle transfer accuracies of 0.73 mm and 0.12 mm, respectively. In the patient cases, the marker-based approach was the superior technique for CBCT-TRUS fusions. CONCLUSION: Inter-observer variability in needle reconstruction can substantially affect dosimetry for individual patients. Especially marker-based CBCT-TRUS registrations can help to ensure accurate reconstructions for improved treatment planning.


Assuntos
Braquiterapia , Tomografia Computadorizada de Feixe Cônico , Agulhas , Variações Dependentes do Observador , Imagens de Fantasmas , Neoplasias da Próstata , Dosagem Radioterapêutica , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/diagnóstico por imagem , Braquiterapia/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Ultrassonografia/métodos , Próstata/diagnóstico por imagem , Órgãos em Risco/efeitos da radiação , Radioterapia Guiada por Imagem/métodos , Reto/diagnóstico por imagem
11.
J Radiat Res ; 65(4): 507-511, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-38934659

RESUMO

The aim of this study was to investigate planning target volume (PTV) margin in online adaptive radiation therapy (oART) for gastric mucosa-associated lymphoid tissue (MALT) lymphomas. Four consecutive patients with gastric MALT lymphoma who received oART (30 Gy in 15 fractions) on the oART system were included in this study. One hundred and twenty cone-beam computed tomography (CBCT) scans acquired pre- and post-treatment of 60 fractions for all patients were used to evaluate intra- and interfractional motions. Patients were instructed on breath-holding at exhalation during image acquisition. To assess the intrafraction gastric motion, different PTVs were created by isotropically extending the CTV contoured on a pre-CBCT image (CTVpre) at1 mm intervals. Intrafraction motion was defined as the amount of expansion covering the contoured CTV on post-CBCT images (CTVpost). Interfractional motion was defined as the amount of reference CTV expansion that could cover each CTVpre, as well as the evaluation of the intrafractional motion. PTV margins were estimated from the cumulative proportion of fraction covering the intra- and interfractional motions. The extent of expansion covering the CTVs in 90% of fractions was adopted as the PTV margin. The PTV margin for intrafractional gastric motion using the oART system with breath-holding was 14 mm. In contrast, the PTV margin for interfractional gastric organ motion without the oART system was 25 mm. These results indicated that the oART system can reduce the PTV margin by >10 mm. Our results could be valuable data for oART cases.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Linfoma de Zona Marginal Tipo Células B , Planejamento da Radioterapia Assistida por Computador , Neoplasias Gástricas , Humanos , Linfoma de Zona Marginal Tipo Células B/radioterapia , Linfoma de Zona Marginal Tipo Células B/diagnóstico por imagem , Neoplasias Gástricas/radioterapia , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Radioterapia Guiada por Imagem/métodos , Sistemas On-Line
12.
Phys Med Biol ; 69(15)2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-38861995

RESUMO

We previously proposed range-guided adaptive proton therapy (RGAPT) that uses mid-range treatment beams as probing beams and intra-fractionated range measurements for online adaptation. In this work, we demonstrated experimental verification and reported the dosimetric accuracy for RGAPT. A STEEV phantom was used for the experiments, and a 3 × 3 × 3 cm3cube inside the phantom was assigned to be the treatment target. We simulated three online range shift scenarios: reference, overshoot, and undershoot, by placing upstream Lucite sheets, 4, 0, and 8 that corresponded to changes of 0, 6.8, and -6.8 mm, respectively, in water-equivalent path length. The reference treatment plan was to deliver single-field uniform target doses in pencil beam scanning mode and generated on the Eclipse treatment planning system. Different numbers of mid-range layers, including single, three, and five layers, were selected as probing beams to evaluate beam range (BR) measurement accuracy in positron emission tomography (PET). Online plans were modified to adapt to BR shifts and compensate for probing beam doses. In contrast, non-adaptive plans were also delivered and compared to adaptive plans by film measurements. The mid-range probing beams of three (5.55MU) and five layers (8.71MU) yielded accurate range shift measurements in 60 s of PET acquisition with uncertainty of 0.5 mm while the single-layer probing (1.65MU) was not sufficient for measurements. The adaptive plans achieved an average gamma (2%/2 mm) passing rate of 95%. In contrast, the non-adaptive plans only had an average passing rate of 69%. RGAPT planning and delivery are feasible and verified by the experiments. The probing beam delivery, range measurements, and adaptive planning and delivery added a small increase in treatment delivery workflow time but resulted in substantial dose improvement. The three-layer mid-range probing was most suitable considering the balance of high range measurement accuracy and the low number of probing beam layers.


Assuntos
Imagens de Fantasmas , Terapia com Prótons , Planejamento da Radioterapia Assistida por Computador , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Fracionamento da Dose de Radiação , Radioterapia Guiada por Imagem/métodos , Radiometria
13.
Phys Med Biol ; 69(15)2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-38861997

RESUMO

Objective.Develop a prototype on-line positron emission tomography (PET) scanner and evaluate its capability of on-line imaging and intra-fractionated proton-induced radioactivity range measurement.Approach.Each detector consists of 32 × 32 array of 2 × 2 × 30 mm3Lutetium-Yttrium Oxyorthosilicate scintillators with single-scintillator-end readout through a 20 × 20 array of 3 × 3 mm2Silicon Photomultipliers. The PET can be configurated with a full-ring of 20 detectors for conventional PET imaging or a partial-ring of 18 detectors for on-line imaging and range measurement. All detector-level readout and processing electronics are attached to the backside of the system gantry and their output signals are transferred to a field-programable-gate-array based system electronics and data acquisition that can be placed 2 m away from the gantry. The PET imaging performance and radioactivity range measurement capability were evaluated by both the offline study that placed a radioactive source with known intensity and distribution within a phantom and the online study that irradiated a phantom with proton beams under different radiation and imaging conditions.Main results.The PET has 32 cm diameter and 6.5 cm axial length field-of-view (FOV), ∼2.3-5.0 mm spatial resolution within FOV, 3% sensitivity at the FOV center, 18%-30% energy resolution, and ∼9 ns coincidence time resolution. The offline study shows the PET can determine the shift of distal falloff edge position of a known radioactivity distribution with the accuracy of 0.3 ± 0.3 mm even without attenuation and scatter corrections, and online study shows the PET can measure the shift of proton-induced positron radioactive range with the accuracy of 0.6 ± 0.3 mm from the data acquired with a short-acquisition (60 s) and low-dose (5 MU) proton radiation to a human head phantom.Significance.This study demonstrated the capability of intra-fractionated PET imaging and radioactivity range measurement and will enable the investigation on the feasibility of intra-fractionated, range-shift compensated adaptive proton therapy.


Assuntos
Imagens de Fantasmas , Tomografia por Emissão de Pósitrons , Terapia com Prótons , Radioterapia Guiada por Imagem , Terapia com Prótons/instrumentação , Terapia com Prótons/métodos , Tomografia por Emissão de Pósitrons/instrumentação , Radioterapia Guiada por Imagem/métodos , Radioterapia Guiada por Imagem/instrumentação , Humanos , Fracionamento da Dose de Radiação
14.
Radiat Oncol ; 19(1): 71, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38849900

RESUMO

BACKGROUND: Particle therapy makes a noteworthy contribution in the treatment of tumor diseases. In order to be able to irradiate from different angles, usually expensive, complex and large gantries are used. Instead rotating the beam via a gantry, the patient itself might be rotated. Here we present tolerance and compliance of volunteers for a fully-enclosed patient rotation system in a clinical magnetic resonance (MR)-scanner for potential use in MR-guided radiotherapy, conducted within a prospective evaluation study. METHODS: A patient rotation system was used to simulate and perform magnetic resonance imaging (MRI)-examinations with 50 volunteers without an oncological question. For 20 participants, the MR-examination within the bore was simulated by introducing realistic MRI noise, whereas 30 participants received an examination with image acquisition. Initially, body parameters and claustrophobia were assessed. The subjects were then rotated to different angles for simulation (0°, 45°, 90°, 180°) and imaging (0°, 70°, 90°, 110°). At each angle, anxiety and motion sickness were assessed using a 6-item State-Trait-Anxiety-Inventory (STAI-6) and a modified Motion Sickness Assessment Questionnaire (MSAQ). In addition, general areas of discomfort were evaluated. RESULTS: Out of 50 subjects, three (6%) subjects terminated the study prematurely. One subject dropped out during simulation due to nausea while rotating to 45°. During imaging, further two subjects dropped out due to shoulder pain from positioning at 90° and 110°, respectively. The average result for claustrophobia (0 = no claustrophobia to 4 = extreme claustrophobia) was none to light claustrophobia (average score: simulation 0.64 ± 0.33, imaging 0.51 ± 0.39). The mean anxiety scores (0% = no anxiety to 100% = maximal anxiety) were 11.04% (simulation) and 15.82% (imaging). Mean motion sickness scores (0% = no motion sickness to 100% = maximal motion sickness) of 3.5% (simulation) and 6.76% (imaging) were obtained across all participants. CONCLUSION: Our study proves the feasibility of horizontal rotation in a fully-enclosed rotation system within an MR-scanner. Anxiety scores were low and motion sickness was only a minor influence. Both anxiety and motion sickness showed no angular dependency. Further optimizations with regard to immobilization in the rotation device may increase subject comfort.


Assuntos
Imageamento por Ressonância Magnética , Radioterapia Guiada por Imagem , Humanos , Estudos Prospectivos , Masculino , Feminino , Imageamento por Ressonância Magnética/métodos , Adulto , Rotação , Radioterapia Guiada por Imagem/métodos , Pessoa de Meia-Idade , Adulto Jovem , Enjoo devido ao Movimento/etiologia , Cooperação do Paciente , Ansiedade/etiologia , Voluntários Saudáveis
15.
Eur J Surg Oncol ; 50(7): 108429, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38788357

RESUMO

PURPOSE: To assess the efficacy and safety of computed tomography (CT)-guided high-dose-rate HDR) brachytherapy in treating recurrent hepatocellular carcinoma (HCC) not amenable to repeated resection or radiofrequency ablation. MATERIALS AND METHODS: From January 2010 to January 2022, 38 patients (mean age, 70.1 years; SD ± 9.0 years) with 79 nodular and four diffuse intrahepatic HCC recurrences not amenable to repeated resection or radiofrequency ablation underwent CT-guided HDR brachytheapy in our department. Tumor response was evaluated by cross-sectional imaging 6 weeks after CT-guided HDR brachytherapy and every 3 months thereafter. Local tumor control (LTC), progression-free survival (PFS) and overall survival (OS) were assessed using Kaplan-Meier curves (KPCs). Severity of procedure-related complications (PRCs) was classified as recommended by the Society of Interventional Radiology (SIR). RESULTS: Patients were available for MRI evaluation for a mean follow-up of 33.1 months (SD, ±21.6 mm, range 4-86 months; median 29 months). Patients had a mean of 2.3 (SD, ±1.4) intrahepatic tumors. Mean tumor diameter was 43.2 mm (SD, ±19.6 mm). 13 of 38 (34.2%) patients showed local tumor progression after CT-guided HDR brachytherapy. Mean LTC was 29.3 months (SD, ±22.1). Distant tumor progression was seen in 12 patients (31.6%). The mean PFS was 20.8 months (SD, ±22.1). Estimated 1-, 3-, and 5-year PFS rates were 65.1%, 35.1% and 22.5%, respectively. 13 patients died during the follow-up period. Mean OS was 35.4 months (SD, ±21.7). Estimated 1-, 3-, and 5-year OS rates were 91.5%, 77.4% and 58.0%, respectively. SIR grade 1 complications were recorded in 8.6% (5/38) and SIR grade 2 complications in 3.4% (2/58) of interventions. CONCLUSION: CT-guided HDR brachytherapy is a safe and efficient therapeutic option for managing large or critically located HCC recurrences in the remaining liver after prior hepatic resection.


Assuntos
Braquiterapia , Carcinoma Hepatocelular , Neoplasias Hepáticas , Recidiva Local de Neoplasia , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Braquiterapia/métodos , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Idoso , Masculino , Feminino , Pessoa de Meia-Idade , Radioterapia Guiada por Imagem/métodos , Ablação por Radiofrequência/métodos , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Dosagem Radioterapêutica , Taxa de Sobrevida , Intervalo Livre de Progressão
16.
JNCI Cancer Spectr ; 8(3)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38730548

RESUMO

BACKGROUND: Traditional constraints specify that 700 cc of liver should be spared a hepatotoxic dose when delivering liver-directed radiotherapy to reduce the risk of inducing liver failure. We investigated the role of single-photon emission computed tomography (SPECT) to identify and preferentially avoid functional liver during liver-directed radiation treatment planning in patients with preserved liver function but limited functional liver volume after receiving prior hepatotoxic chemotherapy or surgical resection. METHODS: This phase I trial with a 3 + 3 design evaluated the safety of liver-directed radiotherapy using escalating functional liver radiation dose constraints in patients with liver metastases. Dose-limiting toxicities were assessed 6-8 weeks and 6 months after completing radiotherapy. RESULTS: All 12 patients had colorectal liver metastases and received prior hepatotoxic chemotherapy; 8 patients underwent prior liver resection. Median computed tomography anatomical nontumor liver volume was 1584 cc (range = 764-2699 cc). Median SPECT functional liver volume was 1117 cc (range = 570-1928 cc). Median nontarget computed tomography and SPECT liver volumes below the volumetric dose constraint were 997 cc (range = 544-1576 cc) and 684 cc (range = 429-1244 cc), respectively. The prescription dose was 67.5-75 Gy in 15 fractions or 75-100 Gy in 25 fractions. No dose-limiting toxicities were observed during follow-up. One-year in-field control was 57%. One-year overall survival was 73%. CONCLUSION: Liver-directed radiotherapy can be safely delivered to high doses when incorporating functional SPECT into the radiation treatment planning process, which may enable sparing of lower volumes of liver than traditionally accepted in patients with preserved liver function. TRIAL REGISTRATION: NCT02626312.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Fígado , Radioterapia Guiada por Imagem , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Masculino , Feminino , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Fígado/diagnóstico por imagem , Fígado/efeitos da radiação , Radioterapia Guiada por Imagem/métodos , Neoplasias Colorretais/radioterapia , Neoplasias Colorretais/patologia , Neoplasias Colorretais/diagnóstico por imagem , Tamanho do Órgão , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X , Planejamento da Radioterapia Assistida por Computador/métodos , Adulto
17.
Curr Oncol ; 31(5): 2679-2688, 2024 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-38785484

RESUMO

The use of hypofractionated radiotherapy in prostate cancer has been increasingly evaluated, whereas accumulated evidence demonstrates comparable oncologic outcomes and toxicity rates compared to normofractionated radiotherapy. In this prospective study, we evaluate all patients with intermediate-risk prostate cancer treated with ultrahypofractionated (UHF) MRI-guided radiotherapy on a 1.5 T MR-Linac within our department and report on workflow and feasibility, as well as physician-recorded and patient-reported longitudinal toxicity. A total of 23 patients with intermediate-risk prostate cancer treated on the 1.5 T MR-Linac with a dose of 42.7 Gy in seven fractions (seven MV step-and-shoot IMRT) were evaluated within the MRL-01 study (NCT04172753). The duration of each treatment step, choice of workflow (adapt to shape-ATS or adapt to position-ATP) and technical and/or patient-sided treatment failure were recorded for each fraction and patient. Acute and late toxicity were scored according to RTOG and CTC V4.0, as well as the use of patient-reported questionnaires. The median follow-up was 12.4 months. All patients completed the planned treatment. The mean duration of a treatment session was 38.2 min. In total, 165 radiotherapy fractions were delivered. ATS was performed in 150 fractions, 5 fractions were delivered using ATP, and 10 fractions were delivered using both ATS and ATP workflows. Severe acute bother (G3+) regarding IPS-score was reported in five patients (23%) at the end of radiotherapy. However, this tended to normalize and no G3+ IPS-score was observed later at any point during follow-up. Furthermore, no other severe genitourinary (GU) or gastrointestinal (GI) acute or late toxicity was observed. One-year biochemical-free recurrence survival was 100%. We report the excellent feasibility of UHF MR-guided radiotherapy for intermediate-risk prostate cancer patients and acceptable toxicity rates in our preliminary study. Randomized controlled studies with long-term follow-up are warranted to detect possible advantages over current state-of-the-art RT techniques.


Assuntos
Neoplasias da Próstata , Radioterapia Guiada por Imagem , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Estudos Prospectivos , Idoso , Radioterapia Guiada por Imagem/métodos , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Hipofracionamento da Dose de Radiação , Idoso de 80 Anos ou mais
18.
Radiother Oncol ; 197: 110332, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38763356

RESUMO

PURPOSE: Deep learning can automate delineation in radiation therapy, reducing time and variability. Yet, its efficacy varies across different institutions, scanners, or settings, emphasizing the need for adaptable and robust models in clinical environments. Our study demonstrates the effectiveness of the transfer learning (TL) approach in enhancing the generalizability of deep learning models for auto-segmentation of organs-at-risk (OARs) in cervical brachytherapy. METHODS: A pre-trained model was developed using 120 scans with ring and tandem applicator on a 3T magnetic resonance (MR) scanner (RT3). Four OARs were segmented and evaluated. Segmentation performance was evaluated by Volumetric Dice Similarity Coefficient (vDSC), 95 % Hausdorff Distance (HD95), surface DSC, and Added Path Length (APL). The model was fine-tuned on three out-of-distribution target groups. Pre- and post-TL outcomes, and influence of number of fine-tuning scans, were compared. A model trained with one group (Single) and a model trained with all four groups (Mixed) were evaluated on both seen and unseen data distributions. RESULTS: TL enhanced segmentation accuracy across target groups, matching the pre-trained model's performance. The first five fine-tuning scans led to the most noticeable improvements, with performance plateauing with more data. TL outperformed training-from-scratch given the same training data. The Mixed model performed similarly to the Single model on RT3 scans but demonstrated superior performance on unseen data. CONCLUSIONS: TL can improve a model's generalizability for OAR segmentation in MR-guided cervical brachytherapy, requiring less fine-tuning data and reduced training time. These results provide a foundation for developing adaptable models to accommodate clinical settings.


Assuntos
Braquiterapia , Aprendizado Profundo , Órgãos em Risco , Neoplasias do Colo do Útero , Humanos , Braquiterapia/métodos , Feminino , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/diagnóstico por imagem , Órgãos em Risco/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Radioterapia Guiada por Imagem/métodos
19.
Radiother Oncol ; 197: 110347, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38815694

RESUMO

PURPOSE: Stereotactic body radiotherapy (SBRT) has emerged as a promising new modality for locally advanced pancreatic cancer (LAPC). The current study evaluated the efficacy and toxicity of SBRT in patients with LAPC (NCT03648632). METHODS: This prospective single institution phase II study recruited patients with histologically or cytologically proven adenocarcinoma of the pancreas after more than two months of combination chemotherapy with no sign of progressive disease. Patients were prescribed 50-60 Gy in 5-8 fractions. Patients were initially treated on a standard linac (n = 4). Since 2019, patients were treated using online magnetic resonance (MR) image-guidance on a 1.5 T MRI-linac, where the treatment plan was adapted to the anatomy of the day. The primary endpoint was resection rate. RESULTS: Twenty-eight patients were enrolled between August 2018 and March 2022. All patients had non-resectable disease at time of diagnosis. Median follow-up from inclusion was 28.3 months (95 % CI 24.0-NR). Median progression-free and overall survival from inclusion were 7.8 months (95 % CI 5.0-14.8) and 16.5 months (95 % CI 10.7-22.6), respectively. Six patients experienced grade III treatment-related adverse events (jaundice, nausea, vomiting and/or constipation). One of the initial four patients receiving treatment on a standard linac experienced a grade IV perforation of the duodenum. Six patients (21 %) underwent resection. A further one patient was offered resection but declined. CONCLUSION: This study demonstrates that SBRT in patients with LAPC was associated with promising overall survival and resection rates. Furthermore, SBRT was safe and well tolerated, with limited severe toxicities.


Assuntos
Neoplasias Pancreáticas , Radiocirurgia , Humanos , Radiocirurgia/métodos , Radiocirurgia/efeitos adversos , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas/diagnóstico por imagem , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso de 80 Anos ou mais , Radioterapia Guiada por Imagem/métodos , Adenocarcinoma/patologia , Adenocarcinoma/radioterapia , Adenocarcinoma/cirurgia , Adenocarcinoma/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
20.
Gulf J Oncolog ; 1(45): 94-99, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38774938

RESUMO

PURPOSE: We report the use of online adaptive radiotherapy (OART) aiming to improve dosimetric parameters in the prostate cancer patient who had lower urinary tract symptoms that caused him not to adhere to the standard bladder filling protocol. METHODS AND MATERIALS: The reference treatment plan for adaptive radiotherapy plan was generated for the pelvis and the solitary bony lesion using the Ethos treatment planning system. For each treatment session, high-quality iterative reconstructed cone beam CT (CBCT) images were acquired, and the system automatically generated an optimal adaptive plan after verification of contours. Image-guided RT (IGRT) plans were also created using the reference plan recalculated on the CBCT scan and were compared with adaptive plans. RESULTS: The reference bladder volume in the planning CT scan was 173 cc, and the mean bladder volume difference over the course was 25.4% ± 16.6%. The ART offered superior target coverage for PTV 70 Gy over online IGRT (V95: 90.5 ± 3.2 % Vs 97.3 ± 0.4%; p=0.000) and the bladder was also better spared from the high dose (V65 Gy: 17.9 ± 9.1% vs 14.8 ± 3.6%; p=0.03). However, the mean rectum V65 doses were very similar in both plans. CONCLUSION: Managing the inconsistent bladder volume was feasible in the prostate cancer patient using the CBCT-guided OART and our analysis confirmed that adaptive plans offered better target coverage while sparing the bladder from high radiation doses in comparison to online IGRT plans. KEY WORDS: radiotherapy, CBCT, online adaptive radiotherapy, image-guided RT.


Assuntos
Neoplasias da Próstata , Planejamento da Radioterapia Assistida por Computador , Bexiga Urinária , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Bexiga Urinária/patologia , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Idoso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...