Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.214
Filtrar
1.
Medicina (Kaunas) ; 60(7)2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-39064451

RESUMO

Background and Objectives: Myopia is the most widespread ocular disorder globally and its prevalence has been increasing over the past decades. Atropine eye drops stand out as the only pharmacological intervention used in clinical practice to control myopia progression. The aim of this study was to explore the effect of 0.01% atropine eye drops on myopia progression. Patients and Methods: Healthy children aged 6-12 years with cycloplegic spherical equivalent (SE) from -0.5 D to -5.0 D and astigmatism ≤1.5 D were included. Myopia progression was assessed by changes in SE and axial length (AL) over 1 year and SE changes 1 year before the study enrollment and during the 1-year follow-up. Adverse events were evaluated based on complaints reported by either parents or the children themselves during follow-up visits. Results: The analysis involved 55 patients in the 0.01% atropine eye drops group and 66 in the control group. After the 1-year follow-up, the change in SE was -0.50 (-2.25-0.50) D in the control group compared to -0.50 (-1.50-0.50) D in the 0.01% atropine group (p = 0.935); AL change was 0.31 (0.18) mm in the control group and 0.29 (0.18) mm in the 0.01% atropine group (p = 0.480). The change in SE was -0.68 (-2.0--0.25) D/year before the study and remained similar -0.50 (-2.25-0.25) D over the 1-year follow-up in the control group (p = 0.111); SE change was reduced from -1.01 (-2.0--0.25) D/year before the study to -0.50 (-1.5-0.5) D over the 1-year follow-up in the 0.01% atropine group (p < 0.001). In the 0.01% atropine group, ten (16.4%) children experienced mild adverse events, including blurred near vision, ocular discomfort, photophobia, dry eyes, and anisocoria. Conclusions: Compared to the control group, the administration of 0.01% atropine eye drops demonstrated no significant effect on changes in SE and AL over a 1-year follow-up. However, children in the 0.01% atropine group initially experienced higher myopia progression, which decreased with treatment over the course of 1 year. Future studies should explore the long-term effects, rebound effects, potential genetic associations, and efficacy of higher doses of atropine in managing myopia progression.


Assuntos
Atropina , Miopia , Soluções Oftálmicas , Humanos , Atropina/administração & dosagem , Atropina/uso terapêutico , Criança , Soluções Oftálmicas/administração & dosagem , Masculino , Feminino , Miopia/tratamento farmacológico , Seguimentos , Midriáticos/administração & dosagem , Midriáticos/uso terapêutico , População Branca/estatística & dados numéricos , Refração Ocular/efeitos dos fármacos , Refração Ocular/fisiologia
2.
Int Ophthalmol ; 44(1): 302, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38954134

RESUMO

PURPOSE: To compare early changes in the corneal biomechanical parameters after photorefractive keratectomy (PRK) and small incision lenticule extraction (SMILE) and their correlations with corneal shape parameters. METHODS: One hundred twenty four eyes received myopic PRK and SMILE for similar amounts of myopia. Corneal tomography with Pentacam HR, biomechanical parameters using Corvis ST, and Ocular Response Analyzer (ORA) were evaluated before and 2 weeks after surgery. The change in each parameter was compared between groups, while the difference in central corneal thickness and cornea-compensated intraocular pressure measured before and after surgery were considered as covariates. RESULTS: A significant reduction was seen in the corneal stiffness parameter at first applanation, and an increase in deformation amplitude ratio (DAR), and integrated inverse radius (IIR) in both groups after surgery (p < 0.001) Changes in DAR, and IIR were significantly greater in the SMILE than in the PRK group (p < 0.001) Corneal hysteresis (CH) and corneal resistance factor (CRF) decreased in both SMILE and PRK groups after surgery, (p < 0.001) with no statistically significant difference between groups (p > 0.05) Among new Corvis ST parameters, DAR showed a significant correlation with changes in Ambrosio relational thickness in both groups (p < 0.05). CONCLUSIONS: Both techniques caused significant changes in corneal biomechanics in the early postoperative period, with greater elastic changes in the SMILE group compared to the PRK group, likely due to lower tension in the SMILE cap and thinner residual stromal bed in SMILE. There were no differences in viscoelastic changes between them, so the lower CH may reflect the volume of tissue removed.


Assuntos
Córnea , Elasticidade , Miopia , Ceratectomia Fotorrefrativa , Humanos , Ceratectomia Fotorrefrativa/métodos , Miopia/cirurgia , Miopia/fisiopatologia , Córnea/cirurgia , Córnea/fisiopatologia , Córnea/diagnóstico por imagem , Feminino , Masculino , Adulto , Elasticidade/fisiologia , Fenômenos Biomecânicos , Adulto Jovem , Lasers de Excimer/uso terapêutico , Pressão Intraocular/fisiologia , Cirurgia da Córnea a Laser/métodos , Refração Ocular/fisiologia , Topografia da Córnea , Substância Própria/cirurgia , Período Pós-Operatório , Acuidade Visual/fisiologia , Estudos Prospectivos , Seguimentos
4.
Digit J Ophthalmol ; 30(2): 27-32, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38962666

RESUMO

We present the case of a 65-year-old man with bilateral keratoconus and history of bilateral penetrating keratoplasty (PK) who developed gradual visual decline in the left eye due to cataract formation. Following successful left eye cataract surgery and monofocal, non-toric intraocular lens (IOL) in-the-bag implantation, the patient experienced persistently low uncorrected distance visual acuity (UDVA) due to high residual refractive error and intolerance to contact lenses. A supplementary toric IOL was placed in the ciliary sulcus, but subsequent rotational instability of the lens required repeated realignment. Despite two attempts at IOL repositioning, the rotational instability persisted, necessitating the replacement of the original Sulcoflex IOL with a toric, implantable Collamer lens. Following the implantation of the toric ICL, the patient achieved excellent UDVA with no adverse events over a 4-year follow-up period. This case highlights the potential rotational instability associated with toric piggyback IOLs in keratoconic, post-PK, pseudophakic eyes and the special considerations on choosing the type of piggyback lens in these eyes.


Assuntos
Ceratoplastia Penetrante , Implante de Lente Intraocular , Lentes Intraoculares , Desenho de Prótese , Pseudofacia , Acuidade Visual , Humanos , Masculino , Idoso , Pseudofacia/cirurgia , Pseudofacia/fisiopatologia , Ceratoplastia Penetrante/efeitos adversos , Ceratoplastia Penetrante/métodos , Implante de Lente Intraocular/métodos , Ceratocone/cirurgia , Ceratocone/diagnóstico , Refração Ocular/fisiologia , Complicações Pós-Operatórias/cirurgia , Complicações Pós-Operatórias/etiologia , Reoperação , Rotação
5.
Int Ophthalmol ; 44(1): 331, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39037500

RESUMO

PURPOSE: To compare the clinical outcomes of myopiacorrected with corneal-wavefront-guided (CWG) laser in situ keratomileusis (LASIK) with AMARIS 1050S (SCHWIND eye-tech-solutions GmbH & Co. KG) and corneal-topography-guided (CTG) LASIK with WaveLight EX500 (Alcon Laboratories, Fort Worth, TX). METHODS: In this prospective, pseudo-randomized expanded cohort study, a total of 266 patients were subjected to binocular LASIK surgery, either with WaveLight EX500 (WaveLight group) or Amaris 1050S (AMARIS group) platforms. Data related to right eyes were selected for analysis. Corneal higher-order aberration (HOA) was selected as the primary endpoint; while visual acuity and refraction were the secondary endpoints. All the endpoints were assessed at 3 months postoperatively. RESULTS: There were 134 eyes in the AMARIS group and 132 eyes in the WaveLight group. After 3 months of postoperative follow-up, spherical and coma aberrations were significantly lower (P < 0.05) in the WaveLight group (spherical aberration: - 0.104 ± 0.199 µm; coma aberration: - 0.117 ± 0.202 µm) in comparison with the AMARIS group (spherical aberrations: 0.254 ± 0.146 µm; coma aberrations: 0.316 ± 0.297 µm). In the AMARIS group, 96.3% of the eyes achieved an uncorrected distance visual acuity (UDVA) of 20/20 while in the WaveLight group, 96.2% of the eyes achieved an UDVA of 20/20. Furthermore, the mean postoperative manifest refraction spherical equivalent (MRSE) was - 0.02 ± 0.28 in the AMARIS group and - 0.05 ± 0.21 in the WaveLight group (P = 0.34). CONCLUSIONS: Both WaveLight EX500 and Amaris 1050S LASIK showed excellent refractive and visual outcomes. In addition, the WaveLight group showed minimal spherical and coma aberrations when compared to the AMARIS group.


Assuntos
Córnea , Topografia da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Refração Ocular , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Feminino , Estudos Prospectivos , Masculino , Adulto , Refração Ocular/fisiologia , Miopia/cirurgia , Miopia/fisiopatologia , Lasers de Excimer/uso terapêutico , Córnea/cirurgia , Adulto Jovem , Resultado do Tratamento , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/diagnóstico , Seguimentos
6.
J Refract Surg ; 40(7): e490-e498, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007811

RESUMO

PURPOSE: To compare the objective visual quality of moderate-to-high myopia corrected by small incision lenticule extraction (SMILE) and transepithelial photorefractive keratectomy (TransPRK) at a 1,050-Hz ablation frequency, assisted by Smart-Pulse technology (SCHWIND eye-tech-solutions). METHODS: This study involved 123 patients (123 eyes) with moderate-to-high myopia between July 2020 and January 2021. They were categorized into the SMILE group (67 patients, 67 eyes) and the TransPRK group (56 patients, 56 eyes). Follow-ups were conducted at 6 months postoperatively to record the logarithm of the minimum angle of resolution visual acuity, and the Strehl ratio and higher order aberrations were measured using the Sirius anterior segment analysis device (SCHWIND eye-tech-solutions) under a 6-mm pupil diameter at various postoperative intervals. RESULTS: At 1 week and 1 month postoperatively, the uncorrected distance visual acuity (UDVA) in the SMILE group was superior to that in the TransPRK group (P < .05 for both). At 1 week and 1 month postoperatively, the Strehl ratio value in the SMILE group was higher than that in the TransPRK group (P < .05 for both). At 1, 3, and 6 months postoperatively, coma was greater in the SMILE group than in the TransPRK group (P < .05 for all). Spherical aberrations were lower in the SMILE group than in the TransPRK group at 3 and 6 months postoperatively (P < .05). At 6 months postoperatively, UDVA was -0.09 ± 0.08 and -0.11 ± 0.05 logMAR in the SMILE and TransPRK groups, respectively, which exceeded their preoperative corrected distance visual acuity of -0.05 ± 0.04 and -0.09 ± 0.08 logMAR (all P < .001). Compared with preoperative values, the Strehl ratio, total higher order, coma, and spherical aberration differences were significantly increased postoperatively in both groups (all P < .001). CONCLUSIONS: Both surgical methods improved UDVA and each had its advantages. The visual quality of SMILE was superior at 1 week and 1 month postoperatively (Strehl ratio values were higher than those of the TransPRK group), and its spherical aberration was lower than that of the TransPRK group at 3 and 6 months; TransPRK with SmartPulse technology with a 1,050-Hz ablation frequency showed that coma was significantly lower than that of the SMILE group at 1, 3, and 6 months postoperatively. [J Refract Surg. 2024;40(7):e490-e498.].


Assuntos
Substância Própria , Lasers de Excimer , Ceratectomia Fotorrefrativa , Refração Ocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Lasers de Excimer/uso terapêutico , Feminino , Masculino , Ceratectomia Fotorrefrativa/métodos , Adulto , Refração Ocular/fisiologia , Adulto Jovem , Substância Própria/cirurgia , Cirurgia da Córnea a Laser/métodos , Miopia Degenerativa/cirurgia , Miopia Degenerativa/fisiopatologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Topografia da Córnea , Seguimentos , Estudos Prospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Estudos Retrospectivos
7.
J Refract Surg ; 40(7): e499-e505, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007813

RESUMO

PURPOSE: To assess the effects of intraocular lens (IOL) decentration and tilt, as well as age, on postoperative visual function (corrected distance visual acuity [CDVA] and contrast sensitivity) by comparing an extended depth-of-focus IOL using higher order aspheric optics against a monofocal IOL from the same platform. METHODS: This retrospective observational study targeted patients without other eye diseases who underwent surgery to implant the Tecnis Eyhance OptiBlue or the monofocal IOL Tecnis OptiBlue 1-Piece (J&J Vision) during cataract surgery from November 2021 to December 2022. The effects of age, axial length, IOL decentration, tilt, and corneal higher order aberrations (HOAs) on the postoperative 5 m CDVA and area under log contrast sensitivity function (AULCSF) under photopic and scotopic conditions were evaluated within 3 months of surgery. RESULTS: No significant difference was found in postoperative CDVA between the Tecnis Eyhance OptiBlue group (n = 61 eyes) and the Tecnis OptiBlue 1-Piece group (n = 35 eyes), but AULCSF was significantly better in the Tecnis Eyhance OptiBlue group for photopic (1.58 ± 0.13 vs 1.46 ± 0.18; P = .002) and scotopic (1.71 ± 0.11 vs 1.59 ± 0.19; P = .002) eyes. Multivariate analysis showed a negative correlation between AULCSF and IOL decentration and age in the Tecnis Eyhance OptiBlue group (P < .01), with no significant correlation with tilt, axial length, and corneal HOAs. CONCLUSIONS: The Tecnis Eyhance OptiBlue yielded significantly better contrast sensitivity under photopic and scotopic conditions than the Tecnis OptiBlue 1-Piece. However, it is important to consider the effects of IOL decentration and age when evaluating the contrast sensitivity of the Tecnis Eyhance OptiBlue. [J Refract Surg. 2024;40(7):e499-e505.].


Assuntos
Sensibilidades de Contraste , Percepção de Profundidade , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Desenho de Prótese , Pseudofacia , Acuidade Visual , Humanos , Estudos Retrospectivos , Acuidade Visual/fisiologia , Masculino , Feminino , Sensibilidades de Contraste/fisiologia , Idoso , Pessoa de Meia-Idade , Pseudofacia/fisiopatologia , Percepção de Profundidade/fisiologia , Refração Ocular/fisiologia , Migração do Implante de Lente Intraocular/fisiopatologia , Idoso de 80 Anos ou mais , Período Pós-Operatório , Comprimento Axial do Olho , Aberrações de Frente de Onda da Córnea/fisiopatologia
8.
J Refract Surg ; 40(7): e460-e467, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007814

RESUMO

PURPOSE: To evaluate the clinical outcomes, rotational stability, and footplate position of the toric Implantable Collamer Lens (TICL) (STAAR Surgical) in eyes with low vault and analyze factors related to rotational stability. METHODS: This prospective observational study included 59 eyes of 59 patients with insufficient vault (< 250 µm). Postoperative rotation was defined as the difference between the achieved angle and the intraoperative fixation angle, and assessed with a digital anterior segment photograph after full mydriasis at 1 week and 1, 3, and 6 months postoperatively. Ultrasound biomicroscopy was used to determine the ciliary body morphology and position of the footplate. Correlation analysis was employed to identify the risk factors associated with TICL rotation at 6 months postoperatively. RESULTS: At 6 months postoperatively, the mean central vault was 137.4 ± 61.0 µm (range: 40 to 236 µm), and the mean efficacy and safety indices were 1.04 and 1.15, respectively. The mean manifest refractive astigmatism decreased from -1.67 ± 0.82 diopters (D) preoperatively to -0.43 ± 0.33 D postoperatively, and the mean absolute rotation was 4.50 ± 3.08 degrees (range: 0 to 12.50 degrees). The angle of rotation was correlated with the preoperative spherical power (r = -0.318, P = .014), the average value of TICL footplates position (r = 0.284, P = .029), and postoperative astigmatism (r = -.469, P⩽ .001). CONCLUSIONS: TICL implantation is predictable, safe, and effective in correcting myopic astigmatism in eyes with low vault. The rotational stability was acceptable and related to the malposition of the footplate and preoperative spherical power. [J Refract Surg. 2024;40(7):e460-e467.].


Assuntos
Astigmatismo , Implante de Lente Intraocular , Miopia , Lentes Intraoculares Fácicas , Refração Ocular , Acuidade Visual , Humanos , Estudos Prospectivos , Masculino , Feminino , Adulto , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Miopia/cirurgia , Miopia/fisiopatologia , Adulto Jovem , Astigmatismo/fisiopatologia , Astigmatismo/cirurgia , Microscopia Acústica , Rotação , Pessoa de Meia-Idade , Corpo Ciliar/cirurgia , Corpo Ciliar/diagnóstico por imagem
9.
J Refract Surg ; 40(7): e453-e459, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007816

RESUMO

PURPOSE: To compare the prediction accuracy of the Barrett toric calculator using standard or integrated keratometry (IK) mode in combination with predicted or measured posterior corneal astigmatism (PCA) in a group of patients with cataract implanted with non-toric IOLs. METHODS: In this retrospective clinical cohort study, the medical records of patients with age-related cataract who underwent phacoemulsification with the implantation of an aspheric monofocal IOL were reviewed. Four methods, including standard keratometry with predicted PCA (PPCA), IK combined with predicted PCA (IK-PPCA), and IK combined with measured PCA derived from IOLMaster 700 (Carl Zeiss Meditec AG) or CASIA2 (Tomey) (IK-MMPCA or IK-CMPCA), were applied to the Barrett toric calculator to calculate the predicted residual astigmatism. The mean absolute prediction error (MAPE), centroid of the prediction error, and proportion of eyes within the prediction error of ±0.50, ±0.75, and ±1.00 diopters (D) were all ciphered out from the four methods, respectively. RESULTS: Data from 129 eyes of 129 patients were included in this study. The MAPE of the IK-PPCA method (0.57 ± 0.36 D) was significantly smaller than that of the PPCA (0.62 ± 0.38 D) and IK-CMPCA (0.63 ± 0.46 D) methods (P = .048 and .014, respectively). There were no significant differences in the centroid vectors of prediction errors and predictability rates among the four methods (all P > .05). CONCLUSIONS: In the current version of the Barrett toric calculator, the predictive accuracy of the IK mode incorporating PPCA was slightly superior to using the standard keratometry mode or incorporating MPCA. [J Refract Surg. 2024;40(7):e453-e459.].


Assuntos
Astigmatismo , Córnea , Facoemulsificação , Humanos , Astigmatismo/fisiopatologia , Astigmatismo/diagnóstico , Estudos Retrospectivos , Masculino , Feminino , Idoso , Córnea/fisiopatologia , Córnea/patologia , Reprodutibilidade dos Testes , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Implante de Lente Intraocular , Acuidade Visual/fisiologia , Topografia da Córnea/métodos , Refração Ocular/fisiologia , Lentes Intraoculares , Pseudofacia/fisiopatologia
10.
J Refract Surg ; 40(7): e468-e479, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007809

RESUMO

PURPOSE: To assess visual and refractive outcomes and visual function after bilateral RayOne Trifocal toric and nontoric intraocular lens (IOL) (Rayner) implantation in patients with presbyopia. METHODS: Charts of patients with presbyopia who underwent refractive lens exchange with bilateral implantation of the RayOne Trifocal IOL (toric and non-toric) were retrospectively reviewed. Visual and refractive outcomes were evaluated at 3 months. Patient satisfaction, spectacle independence, and visual disturbance profile were assessed by questionnaires. RESULTS: A total of 5,226 patients were assigned to one of two groups: 1,010 patients had toric IOL implantation (toric group) and 4,216 patients received the non-toric model (non-toric group). Mean ± standard deviation visual acuity at 3 months for the toric group was binocular uncorrected distance visual acuity (UDVA) of 0.07 ± 0.11 logMAR, monocular corrected distance visual acuity (CDVA) of 0.05 ± 0.07 logMAR, binocular uncorrected near visual acuity (UNVA) at 40 cm of 0.10 ± 0.09 logMAR, binocular uncorrected intermediate visual acuity (UIVA) at 40 cm of 0.13 ± 0.12 logMAR, postoperative spherical equivalent (SE) of -0.21 ± 0.47 diopters (D), and cylinder of -0.34 ± 0.40 D. The non-toric group had binocular UDVA of 0.04 ± 0.08 logMAR, monocular CDVA of 0.05 ± 0.07 logMAR, binocular UNVA of 0.10 ± 0.08 logMAR, binocular UIVA of 0.13 ± 0.11 logMAR, SE of -0.08 ± 0.38 D, and cylinder of -0.28 ± 0.34 D. No statistically significant differences were found in achieving spectacle independence and there were high levels of satisfaction in both groups. CONCLUSIONS: In this retrospective analysis with more than 5,000 patients, both the toric and non-toric RayOne Trifocal IOL models provided good visual performance at all distances, resulting in excellent levels of spectacle independence and patient satisfaction. [J Refract Surg. 2024;40(7):e468-e479.].


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares Multifocais , Satisfação do Paciente , Facoemulsificação , Presbiopia , Pseudofacia , Refração Ocular , Visão Binocular , Acuidade Visual , Humanos , Presbiopia/cirurgia , Presbiopia/fisiopatologia , Acuidade Visual/fisiologia , Estudos Retrospectivos , Feminino , Masculino , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Inquéritos e Questionários , Visão Binocular/fisiologia , Pseudofacia/fisiopatologia , Idoso , Reoperação , Adulto , Desenho de Prótese , Lentes Intraoculares , Resultado do Tratamento
11.
J Refract Surg ; 40(7): e480-e489, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007817

RESUMO

PURPOSE: To evaluate the effectiveness, safety, and stability of a modified PRESBYOND Laser Blended Vision protocol (Carl Zeiss Meditec AG) for correcting hyperopic astigmatism and presbyopia, using Custom Refractive Software Master (CRSM) targeting over a 6-month period. METHODS: A total of 636 eyes of 318 patients with a mean age of 51.05 ± 4.71 years (range: 40 to 60 years) met the inclusion and exclusion criteria. All patients completed a 6-month follow-up. CRSM software was used to generate ablation profiles for the MEL90 excimer laser (Carl Zeiss Meditec AG). The target refraction was emmetropic for the dominant eyes and between -0.75 and -1.12 diopters (D) for the near eyes. RESULTS: Visual and refractive results were studied separately by the dominant and non-dominant eyes. The mean attempt to correct for spherical equivalent refraction was +2.17 ± 1.16 D (range: -1.00 to +5.37 D). The mean attempted cylinder was -0.60 ± 0.75 D (range: -4.00 to 0.00 D). All eyes monocularly achieved uncorrected distance visual acuity (UDVA) of 20/25 or better after refractive treatment and 88% achieved 20/20. Binocularly all eyes achieved UDVA of 20/25 or better and 96.54% achieved 20/20. Ninety-eight percent of the patients maintained their corrected distance visual acuity before surgery and UDVA 6 months after surgery. CONCLUSIONS: This hyperopic micro-anisometropia protocol with PRESBYOND Laser Blended Vision was an effective, safe, and well-tolerated refractive treatment. It was an effective procedure with excellent results for UDVA and uncorrected near visual acuity and demonstrates that binocular summation exists. [ J Refract Surg. 2024;40(7):e480-e489.].


Assuntos
Astigmatismo , Hiperopia , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Presbiopia , Refração Ocular , Software , Acuidade Visual , Humanos , Presbiopia/cirurgia , Presbiopia/fisiopatologia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Lasers de Excimer/uso terapêutico , Masculino , Hiperopia/fisiopatologia , Hiperopia/cirurgia , Pessoa de Meia-Idade , Feminino , Adulto , Astigmatismo/fisiopatologia , Astigmatismo/cirurgia , Resultado do Tratamento , Anisometropia/fisiopatologia , Anisometropia/cirurgia , Topografia da Córnea , Seguimentos , Estudos Prospectivos , Córnea/fisiopatologia , Córnea/cirurgia
12.
Invest Ophthalmol Vis Sci ; 65(8): 19, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38984874

RESUMO

Purpose: The purpose of this study was to utilize multi-parametric magnetic resonance imaging (MRI) to investigate in vivo age-related changes in the physiology and optics of mouse lenses where Connexin 50 has been deleted (Cx50KO) or replaced by Connexin 46 (Cx50KI46). Methods: The lenses of transgenic Cx50KO and Cx50KI46 mice were imaged between 3 weeks and 6 months of age using a 7T MRI. Measurements of lens geometry, the T2 (water-bound protein ratios), the refractive index (n), and T1 (free water content) values were calculated by processing the acquired images. The lens power was calculated from an optical model that combined the geometry and the n. All transgenic mice were compared with control mice at the same age. Results: Cx50KO and Cx50KI46 mice developed smaller lenses compared with control mice. The lens thickness, volume, and surface radii of curvatures all increased with age but were limited to the size of the lenses. Cx50KO lenses exhibited higher lens power than Cx50KI46 lenses at all ages, and this was correlated with significantly lower water content in these lenses, which was probably modulated by the gap junction coupling. The refractive power tended to a steady state with age, similar to the control mice. Conclusions: The modification of Cx50 gap junctions significantly impacted lens growth and physiological optics as the mouse aged. The lenses showed delayed development growth, and altered optics governed by different lens physiology. This research provides new insights into how gap junctions regulate the development of the lens's physiological optics.


Assuntos
Conexinas , Cristalino , Camundongos Transgênicos , Animais , Cristalino/metabolismo , Conexinas/metabolismo , Conexinas/genética , Camundongos , Imageamento por Ressonância Magnética , Envelhecimento/fisiologia , Refração Ocular/fisiologia , Camundongos Endogâmicos C57BL , Camundongos Knockout , Junções Comunicantes/fisiologia , Junções Comunicantes/metabolismo
13.
BMJ Open Ophthalmol ; 9(1)2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38969362

RESUMO

OBJECTIVES: This study aimed to quantitatively evaluate optic nerve head and retinal vascular parameters in children with hyperopia in relation to age and spherical equivalent refraction (SER) using artificial intelligence (AI)-based analysis of colour fundus photographs (CFP). METHODS AND ANALYSIS: This cross-sectional study included 324 children with hyperopia aged 3-12 years. Participants were divided into low hyperopia (SER+0.5 D to+2.0 D) and moderate-to-high hyperopia (SER≥+2.0 D) groups. Fundus parameters, such as optic disc area and mean vessel diameter, were automatically and quantitatively detected using AI. Significant variables (p<0.05) in the univariate analysis were included in a stepwise multiple linear regression. RESULTS: Overall, 324 children were included, 172 with low and 152 with moderate-to-high hyperopia. The median optic disc area and vessel diameter were 1.42 mm2 and 65.09 µm, respectively. Children with high hyperopia had larger superior neuroretinal rim (NRR) width and larger vessel diameter than those with low and moderate hyperopia. In the univariate analysis, axial length was significantly associated with smaller superior NRR width (ß=-3.030, p<0.001), smaller temporal NRR width (ß=-1.469, p=0.020) and smaller vessel diameter (ß=-0.076, p<0.001). A mild inverse correlation was observed between the optic disc area and vertical disc diameter with age. CONCLUSION: AI-based CFP analysis showed that children with high hyperopia had larger mean vessel diameter but smaller vertical cup-to-disc ratio than those with low hyperopia. This suggests that AI can provide quantitative data on fundus parameters in children with hyperopia.


Assuntos
Inteligência Artificial , Hiperopia , Disco Óptico , Fotografação , Vasos Retinianos , Humanos , Hiperopia/diagnóstico , Hiperopia/fisiopatologia , Estudos Transversais , Masculino , Criança , Feminino , Pré-Escolar , Disco Óptico/diagnóstico por imagem , Disco Óptico/patologia , Disco Óptico/irrigação sanguínea , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia , Fotografação/métodos , Fundo de Olho , Acuidade Visual/fisiologia , Refração Ocular/fisiologia
14.
Rom J Ophthalmol ; 68(2): 122-127, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39006330

RESUMO

Objective: Analysis of refractive errors and strabismus deviations following the visual screening of patients with the Welch Allyn Spot device. Material and Methods: This paper is a prospective cross-sectional study of 4281 patients examined with the Welch Allyn Spot device acquired by Lions Club Romania - District 124. The study was conducted between May 2019 and August 2021 and was performed with the help of Lions Club Romania. Results: In the present study, 4281 patients were evaluated and divided into 5 age groups (6-12 months, 12-36 months, 3-6 years, 6-20 years, and 20-100 years). The most frequent age group was 6-20 years, being identified in 51,97% of participants. We found that the most common refractive error was astigmatism, followed by hyperopia and myopia. Thus, (RE) the refractive errors found in the right eye were: astigmatism 93.23%, hyperopia 4.63%, and myopia 1.05%, and in the left eye (LE): astigmatism 90.40%, hyperopia 6.68%, and myopia 0.84%. Of all participants, 8.81% had horizontal strabismus, esotropia being found in the RE in 4.56% of the participants and the LE in 4.74% of them. Conclusions: The pediatric population was the most affected by astigmatism and esotropia. Abbreviations: RE = right eye, LE = left eye, SD = strabismus deviation.


Assuntos
Erros de Refração , Estrabismo , Seleção Visual , Humanos , Estudos Prospectivos , Estudos Transversais , Pré-Escolar , Criança , Masculino , Lactente , Feminino , Adolescente , Adulto Jovem , Seleção Visual/métodos , Erros de Refração/diagnóstico , Erros de Refração/fisiopatologia , Adulto , Pessoa de Meia-Idade , Estrabismo/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Acuidade Visual , Refração Ocular/fisiologia , Romênia/epidemiologia , Distribuição por Idade
15.
J Vis ; 24(7): 3, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38967946

RESUMO

It was recently established that the axial power, the refractive power required by the eye for a sharp retinal image in an eye of a certain axial length, and the total refractive power of the eye may both be described by a bi-exponential function as a function of age (Rozema, 2023). Inspired by this result, this work explores whether these bi-exponential functions are able to simulate the various known courses of refractive development described in the literature, such as instant emmetropization, persistent hypermetropia, developing hypermetropia, myopia, instant homeostasis, modulated development, or emmetropizing hypermetropes. Moreover, the equations can be adjusted to match the refractive development of school-age myopia and pseudophakia up to the age of 20 years. All of these courses closely resemble those reported in the previous literature while simultaneously providing estimates for the underlying changes in axial and whole eye power.


Assuntos
Emetropia , Hiperopia , Miopia , Refração Ocular , Humanos , Refração Ocular/fisiologia , Miopia/fisiopatologia , Criança , Adolescente , Hiperopia/fisiopatologia , Adulto Jovem , Emetropia/fisiologia , Pré-Escolar , Comprimento Axial do Olho , Pseudofacia/fisiopatologia , Adulto , Olho/crescimento & desenvolvimento , Envelhecimento/fisiologia , Erros de Refração/fisiopatologia
16.
Int Ophthalmol ; 44(1): 334, 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39046597

RESUMO

PURPOSE: To evaluate the clinical outcomes following bilateral implantation of the AcrySof™ IQ Vivity™ toric extended depth of focus (EDOF) intraocular lens (IOL). DESIGN: Prospective interventional case series. METHODS: Patients with bilateral significant cataracts and pre-existing corneal astigmatism underwent cataract surgery and implantation with the AcrySof™ IQ Vivity™ toric IOL. Dominant eyes were targeted at emmetropia and non-dominant eyes at -0.50D. Primary endpoints were binocular uncorrected distance (UDVA), intermediate (UIVA at 66 cm) and near (UNVA at 40 cm) acuities at 3 months. Secondary outcomes were corrected distance (CDVA), distance corrected intermediate (DCIVA) and distance corrected near (DCNVA), refractive predictability, rotational stability, binocular defocus curve, contrast sensitivity, Questionnaire for Visual Disturbances (QUVID) and Visual Function Index (VF-14) questionnaire scores. All visual acuities were converted to logarithm of minimum angle of resolution (logMAR) for analysis. RESULTS: 30 patients underwent uneventful phacoemulsification. The mean binocular UDVA, UIVA and UNVA were 0.06 ± 0.12, 0.11 ± 0.10 and 0.26 ± 0.10 respectively. The mean refractive spherical equivalent (MRSE) for dominant and non-dominant eyes were - 0.07D ± 0.27 and - 0.12D ± 0.54 respectively. 92.4% of dominant eyes and 84.6% of non-dominant eyes within 0.50D of target. The mean IOL rotation was 3.85° ± 5.09 with 86.7% of eyes with less than 5° of rotation. 26.7%, 20% and 36.7% of patients reported starbursts, haloes and glare respectively. The mean VF-14 score was 91.77. CONCLUSION: Bilateral implantation of the AcrySof™ IQ Vivity™ Toric IOL resulted in very good unaided visual acuities for far and intermediate distance with functional near vision. Dysphotopsias were reported but despite this, a high level of visual function was achieved.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Visão Binocular , Acuidade Visual , Humanos , Estudos Prospectivos , Masculino , Feminino , Idoso , Implante de Lente Intraocular/métodos , Pessoa de Meia-Idade , Visão Binocular/fisiologia , Facoemulsificação/métodos , Refração Ocular/fisiologia , Desenho de Prótese , Percepção de Profundidade/fisiologia , Idoso de 80 Anos ou mais , Resultado do Tratamento , Astigmatismo/fisiopatologia , Astigmatismo/cirurgia , Catarata/complicações , Catarata/fisiopatologia
17.
BMC Ophthalmol ; 24(1): 288, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39014345

RESUMO

BACKGROUND: Recently a new surgical technique for intracorneal ring-segments (ICRS) assisted by femtosecond laser (FSL) called ByLimB was developed, involving the creation of the incision from a paralimbic region. This study aims to evaluate the safety and efficacy of the ByLimb technique following one year of follow-up. METHODS: A prospective, single-center study was conducted at the Zaldivar Institute in Buenos Aires, Argentina. Keratoconus patients with indication for ICRS-FSL assisted procedure, operated with the ByLimb technique were included. By using the ByLimb technique, the ICRS are placed without affecting the tunnel's roof, and the end of the ICRS is always away from the incision area. Visual acuity, topographic astigmatism, and the occurrence of complications were evaluated. Safety index was the main outcome and efficacy indes was a complimentary outcome. RESULTS: A total of 17 eyes completed the 12-month follow-up period. The safety index was 1.10 (mean postoperative corrected distance visual acuity (CDVA) in decimal: 0.76/preoperative CDVA: 0.69), while the efficacy index was 0.89 (mean postoperative uncorrected distance visual acuity UDVA in decimal: 0.62/preoperative CDVA: 0.69). Mean preoperative astigmatism was 5.3 ± 2.3, decreasing twelve months after surgery at 2.1 ± 1.2 (p < 0.001). No eye loss lines of vision and no intraoperative complications were observed. During the first month after surgery, an improper positioning of the ICRS based on topographic assessment was detected in five cases. A second procedure was performed, which consisted of opening the incision and introducing a Sinsky hook, through which the ICRS was mobilized and placed in its correct position. No incisional alterations, signs of infection, anterior segment anomalies, or fundus alterations were observed. CONCLUSION: FSL-assisted ICRS implantation through the perilimbal region has demonstrated an adequate safety index one year post-surgery. Additionally, this technique has facilitated accurate realignment of ICRS during secondary surgical interventions within one-month post-surgery. While the current findings are promising, continued follow-up of these cases is warranted.


Assuntos
Topografia da Córnea , Ceratocone , Próteses e Implantes , Implantação de Prótese , Acuidade Visual , Humanos , Estudos Prospectivos , Ceratocone/cirurgia , Ceratocone/fisiopatologia , Feminino , Masculino , Adulto , Projetos Piloto , Acuidade Visual/fisiologia , Implantação de Prótese/métodos , Adulto Jovem , Substância Própria/cirurgia , Seguimentos , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Terapia a Laser/métodos , Resultado do Tratamento
18.
BMC Ophthalmol ; 24(1): 289, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39014346

RESUMO

BACKGROUND: This study assessed the agreement of ocular parameters of patients with myopia measured using Colombo intraocular lens (IOL) 2 and IOLMaster 700. METHODS: Eighty patients (male, 22; average age, 29.14 ± 7.36 years) with myopia (159 eyes) were included in this study in May 2023. The participants' axial length (AXL), central corneal thickness (CCT), lens thickness (LT), white-to-white distance (WTW), front flat (K1), steep (K2), mean (Km) corneal keratometry, astigmatism (Astig), J0 vector, and J45 vector were measured using the IOLMaster 700 and Colombo IOL 2. The measurements from both devices were compared using the generalized estimating equation, correlation analysis, and Bland-Altman plots. RESULTS: With the Colombo IOL 2, lower values for K2 and J0 (odds ratio [OR] = 0.587, p = 0.033; OR = 0.779, p < 0.0001, respectively), and larger values for WTW, Astig, and J45 (OR = 1.277, OR = 1.482, OR = 1.1, all p < 0.0001) were obtained. All ocular measurements by both instruments showed positive correlations, with AXL demonstrating the strongest correlation (r = 0.9996, p < 0.0001). The intraclass correlation coefficients for AXL and CCT measured by both instruments was 0.999 and 0.988 (both p < 0.0001), and Bland-Altman plot showed 95% limits of agreement (LoA) of -0.078 to 0.11 mm and - 9.989 to 13.486 µm, respectively. The maximum absolute 95% LoA for LT, WTW, K1, K2, and J0 were relatively high, achieving 0.829 mm, 0.717 mm, 0.983 D, 0.948 D, and 0.632 D, respectively. CONCLUSIONS: In young patients with myopia, CCT and AXL measurements obtained with the Colombo IOL 2 and IOLMaster 700 were comparable. However, WTW, LT, corneal refractive power, and astigmatism values could not be used interchangeably in clinical practice.


Assuntos
Comprimento Axial do Olho , Biometria , Miopia , Humanos , Masculino , Biometria/métodos , Biometria/instrumentação , Comprimento Axial do Olho/patologia , Miopia/fisiopatologia , Miopia/diagnóstico , Feminino , Adulto , Adulto Jovem , Análise de Fourier , Tomografia de Coerência Óptica/métodos , Segmento Anterior do Olho/diagnóstico por imagem , Segmento Anterior do Olho/patologia , Córnea/patologia , Córnea/diagnóstico por imagem , Refração Ocular/fisiologia
19.
J Vis ; 24(7): 9, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38995108

RESUMO

Ocular wavefront aberrations are used to describe retinal image formation in the study and modeling of foveal and peripheral visual functions and visual development. However, classical eye models generate aberration structures that generally do not resemble those of actual eyes, and simplifications such as rotationally symmetric and coaxial surfaces limit the usefulness of many modern eye models. Drawing on wide-field ocular wavefront aberrations measured previously by five laboratories, 28 emmetropic (-0.50 to +0.50 D) and 20 myopic (-1.50 to -4.50 D) individual optical eye models were reverse-engineered by optical design ray-tracing software. This involved an error function that manipulated 27 anatomical parameters, such as curvatures, asphericities, thicknesses, tilts, and translations-constrained within anatomical limits-to drive the output aberrations of each model to agree with the input (measured) aberrations. From those resultant anatomical parameters, three representative eye models were also defined: an ideal emmetropic eye with minimal aberrations (0.00 D), as well as a typical emmetropic eye (-0.02 D) and myopic eye (-2.75 D). The cohorts and individual models are presented and evaluated in terms of output aberrations and established population expectations, such as Seidel aberration theory and ocular chromatic aberrations. Presented applications of the models include the effect of dual focus contact lenses on peripheral optical quality, the comparison of ophthalmic correction modalities, and the projection of object space across the retina during accommodation.


Assuntos
Emetropia , Miopia , Humanos , Miopia/fisiopatologia , Emetropia/fisiologia , Refração Ocular/fisiologia , Modelos Biológicos
20.
BMC Ophthalmol ; 24(1): 259, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38880899

RESUMO

BACKGROUND: The anatomic structure of the anterior chamber (AC) helps to explain differences in refractive status in school-aged children and is closely associated with primary angle closure (PAC). The aim of this study was to quantify and analyze the anterior chamber and angle (ACA) characteristics in Chinese children with different refractive status by swept-source optical coherence tomography (SS-OCT). METHODS: In a cross-sectional observational study, 383 children from two primary schools in Shandong Province, China, underwent a complete ophthalmic examination. First, the anterior chamber depth (ACD), anterior chamber width (ACW), angle-opening distance (AOD), and trabecular-iris space area (TISA) were evaluated automatically using a CASIA2 imaging device. AOD and TISA were measured at 500, 750 µm nasal (N1 and N2, respectively), and temporal (T1 and T2, respectively) to the scleral spur (SS). Cycloplegic refraction and axial length (AL) were then measured. According to spherical equivalent refraction (SER), the children were assigned to hyperopic (SER > 0.50D), emmetropic (-0.50D < SER ≤ 0.50D), and myopic groups (SER ≤ -0.50D). RESULTS: Out of the 383 children, 349 healthy children (160 girls) with a mean age of 8.23 ± 1.06 years (range: 6-11 years) were included. The mean SER and AL were - 0.10 ± 1.57D and 23.44 ± 0.95 mm, respectively. The mean ACD and ACW were 3.17 ± 0.24 mm and 11.69 ± 0.43 mm. The mean AOD were 0.72 ± 0.25, 0.63 ± 0.22 mm at N1, T1, and 0.98 ± 0.30, 0.84 ± 0.27 mm at N2, T2. The mean TISA were 0.24 ± 0.09, 0.22 ± 0.09mm2 at N1, T1, and 0.46 ± 0.16, 0.40 ± 0.14mm2 at N2, T2. The myopic group had the deepest AC and the widest angle. Compared with boys, girls had shorter AL, shallower ACD, narrower ACW, and ACA (all p < 0.05). By Pearson's correlation analysis, SER was negatively associated with ACD, AOD, and TISA. AL was positively associated with ACD, ACW, AOD, and TISA. In the multiple regression analysis, AOD and TISA were associated with deeper ACD, narrower ACW, and longer AL. CONCLUSION: In primary school students, the myopic eyes have deeper AC and wider angle. ACD, ACW, AOD, and TISA all increase with axial elongation. ACA is highly correlated with deeper ACD.


Assuntos
Câmara Anterior , Refração Ocular , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Criança , Feminino , Masculino , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/patologia , China/epidemiologia , Refração Ocular/fisiologia , Glaucoma de Ângulo Fechado/fisiopatologia , Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Fechado/etnologia , Erros de Refração/fisiopatologia , População do Leste Asiático
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...