Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.247
Filtrar
1.
Medicine (Baltimore) ; 103(32): e39039, 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39121326

RESUMO

Amidst the COVID-19 pandemic, hydroxychloroquine (HCQ) was widely administered despite limited data on its safety and efficacy. This study assesses the acute and chronic impacts of HCQ on electrocardiography (ECG) parameters alongside the effects of azithromycin and levofloxacin coadministration in patients with COVID-19. A comprehensive analysis was conducted on 109 COVID-19 patients receiving HCQ, with or without Azithromycin and/or Levofloxacin, and 51 long-term HCQ-treated Sjogren's syndrome (SS) patients. ECG parameters, including QTc interval, were meticulously evaluated against a control group of 109 COVID-19 patients without HCQ treatment. HCQ monotherapy, in combination with Levofloxacin, significantly prolonged the QTc interval in COVID-19 patients compared to controls. Notably, the combination of HCQ and Azithromycin demonstrated a mitigated impact on QTc prolongation. Long-term HCQ use in SS patients did not significantly affect QTc intervals, illustrating a distinct safety profile from short-term use in COVID-19 treatment. HCQ's impact on QTc prolongation is influenced by therapeutic context, coadministered drugs, and patient demographics. The findings underscore the necessity of cautious HCQ use, particularly in acute settings like COVID-19, where monitoring and consideration of drug interactions and patient-specific factors are critical.


Assuntos
Azitromicina , Tratamento Farmacológico da COVID-19 , Eletrocardiografia , Hidroxicloroquina , Síndrome do QT Longo , Humanos , Hidroxicloroquina/efeitos adversos , Hidroxicloroquina/uso terapêutico , Hidroxicloroquina/administração & dosagem , Eletrocardiografia/efeitos dos fármacos , Feminino , Masculino , Pessoa de Meia-Idade , Azitromicina/uso terapêutico , Azitromicina/efeitos adversos , Azitromicina/administração & dosagem , Síndrome do QT Longo/induzido quimicamente , Idoso , Síndrome de Sjogren/tratamento farmacológico , Quimioterapia Combinada , Levofloxacino/uso terapêutico , Levofloxacino/administração & dosagem , Levofloxacino/efeitos adversos , Adulto , SARS-CoV-2 , COVID-19
3.
PLoS One ; 19(7): e0305248, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38968219

RESUMO

Long QT Syndrome type 8 (LQT8) is a cardiac arrhythmic disorder associated with Timothy Syndrome, stemming from mutations in the CACNA1C gene, particularly the G406R mutation. While prior studies hint at CACNA1C mutations' role in ventricular arrhythmia genesis, the mechanisms, especially in G406R presence, are not fully understood. This computational study explores how the G406R mutation, causing increased transmural dispersion of repolarization, induces and sustains reentrant ventricular arrhythmias. Using three-dimensional numerical simulations on an idealized left-ventricular model, integrating the Bidomain equations with the ten Tusscher-Panfilov ionic model, we observe that G406R mutation with 11% and 50% heterozygosis significantly increases transmural dispersion of repolarization. During S1-S4 stimulation protocols, these gradients facilitate conduction blocks, triggering reentrant ventricular tachycardia. Sustained reentry pathways occur only with G406R mutation at 50% heterozygosis, while neglecting transmural heterogeneities of action potential duration prevents stable reentry, regardless of G406R mutation presence.


Assuntos
Potenciais de Ação , Canais de Cálcio Tipo L , Simulação por Computador , Síndrome do QT Longo , Sindactilia , Humanos , Síndrome do QT Longo/genética , Síndrome do QT Longo/fisiopatologia , Canais de Cálcio Tipo L/genética , Sindactilia/genética , Sindactilia/fisiopatologia , Mutação , Transtorno Autístico/genética , Transtorno Autístico/fisiopatologia , Ventrículos do Coração/fisiopatologia , Modelos Cardiovasculares , Arritmias Cardíacas/genética , Arritmias Cardíacas/fisiopatologia , Taquicardia Ventricular/genética , Taquicardia Ventricular/fisiopatologia
6.
Inn Med (Heidelb) ; 65(8): 787-797, 2024 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-38977442

RESUMO

Genetic arrhythmia disorders are rare diseases; however, they are a common cause of sudden cardiac death in children, adolescents, and young adults. In principle, a distinction can be made between channelopathies and cardiomyopathies in the context of genetic diseases. This paper focuses on the channelopathies long and short QT syndrome, Brugada syndrome, and catecholaminergic polymorphic ventricular tachycardia (CPVT). Early diagnosis of these diseases is essential, as drug therapy, behavioral measures, and if necessary, implantation of a cardioverter defibrillator can significantly improve the prognosis and quality of life of patients. This paper highlights the pathophysiological and genetic basis of these channelopathies, describes their clinical manifestations, and comments on the principles of diagnosis, risk stratification and therapy.


Assuntos
Arritmias Cardíacas , Síndrome de Brugada , Canalopatias , Humanos , Arritmias Cardíacas/genética , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/fisiopatologia , Canalopatias/genética , Canalopatias/diagnóstico , Canalopatias/terapia , Síndrome de Brugada/genética , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatologia , Síndrome de Brugada/terapia , Taquicardia Ventricular/genética , Taquicardia Ventricular/terapia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Adolescente , Criança , Síndrome do QT Longo/genética , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/terapia , Síndrome do QT Longo/fisiopatologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Adulto , Desfibriladores Implantáveis , Eletrocardiografia
7.
Zhonghua Xin Xue Guan Bing Za Zhi ; 52(7): 777-783, 2024 Jul 24.
Artigo em Chinês | MEDLINE | ID: mdl-39019826

RESUMO

Objective: To explore the genetic background and clinical features of patients with long QT syndrome type 3 (LQT3). Methods: This retrospective cohort included patients diagnosed with LQT3 at the Department of Cardiology, Renmin Hospital of Wuhan University from January 1998 to December 2022. Patients were categorized into compound type group and single type group based on the presence of a single SCN5A mutation. The two groups were followed up and the differences in baseline characteristics, electrocardiograms, and clinical events between the two groups and probands were compared. Kaplan-Meier curves were used for survival analysis, and the log-rank test was employed to compare the event-free survival rates of first cardiac events between the groups and probands. Results: A total of 97 LQT3 patients were enrolled, including 59 probands. The age at diagnosis was (23.45±19.86) years, with 46 patients (47.4%) being male. Among them, 89 patients were classified as single type group, while 8 patients were classified as compound type group. Genetic testing identified 49 SCN5A mutations, with missense mutations being the majority (91.8%), primarily located in transmembrane regions (40.8%, n=20), interdomain linker regions (28.6%, n=14), and C-terminus (22.4%, n=11). The first cardiac event occurred in 44 patients (45.4%), with an onset age of (13.82±12.50) years. The main trigger was identified as rest or sleep (54.5%, n=24). Compared with patients in single type group, patients in compound type group were younger at diagnosis ((10.35±10.28) years vs. (24.63±20.13) years, P=0.040), had a significantly higher proportion of syncope (87.5% (7/8) vs. 33.7% (30/89), P=0.009), aborted cardiac arrest (62.5% (5/8) vs. 11.2% (10/89), P=0.001), and a lower incidence of event-free survival rates of first cardiac events (12.5% (1/8) vs.58.4% (52/89), log-rank P=0.001). The probands in compound type group had a significantly higher proportion of aborted cardiac arrest comparing to probands in single type group (62.5% (5/8) vs. 17.6% (9/51), P=0.020), while the difference in the incidence rate of event-free survival rates of first cardiac events between the probands in two groups was not statistically significant (12.5% (1/8) vs. 39.2% (20/51), log-rank P=0.08). Conclusion: Compound type LQT3 patients are not uncommon. Such patients are diagnosed at a younger age and exhibit more severe phenotypes, requiring close follow-up and proactive intervention strategies.


Assuntos
Síndrome do QT Longo , Mutação , Canal de Sódio Disparado por Voltagem NAV1.5 , Humanos , Masculino , Feminino , Síndrome do QT Longo/genética , Estudos Retrospectivos , Adulto , Adulto Jovem , Adolescente , Criança , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Pessoa de Meia-Idade , Pré-Escolar , Eletrocardiografia , Doença do Sistema de Condução Cardíaco
8.
Antimicrob Agents Chemother ; 68(8): e0046424, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-38953364

RESUMO

Islatravir is a deoxynucleoside analog being developed for the treatment of HIV-1 infection. Clinical studies are being conducted to evaluate islatravir, administered in combination with other antiretroviral therapies, at doses of 0.25 mg once daily and 2 mg once weekly. In multiple previous clinical studies, islatravir was generally well tolerated, with no clear trend in cardiac adverse events. A trial was conducted to evaluate the effect of islatravir on cardiac repolarization. A randomized, double-blind, active- and placebo-controlled phase 1 trial was conducted, in which a single dose of islatravir 0.75 mg, islatravir 240 mg (supratherapeutic dose), moxifloxacin 400 mg (active control), or placebo was administered. Continuous 12-lead electrocardiogram monitoring was performed before dosing through 24 hours after dosing. QT interval measurements were collected, and safety and pharmacokinetics were evaluated. Sixty-three participants were enrolled, and 59 completed the study. Fridericia's QT correction for heart rate was inadequate; therefore, a population-specific correction was applied (QTcP). The placebo-corrected change from baseline in QTcP (ΔΔQTcP) interval at the observed geometric mean maximum plasma concentration associated with islatravir 0.75 mg and islatravir 240 mg was <10 ms at all time points. Assay sensitivity was confirmed because the use of moxifloxacin 400 mg led to a ΔΔQTcP >10 ms. The pharmacokinetic profile of islatravir was consistent with that of previous studies, and islatravir was generally well tolerated. Results from the current trial suggest that single doses of islatravir as high as 240 mg do not lead to QTc interval prolongation.


Assuntos
Eletrocardiografia , Fluoroquinolonas , Moxifloxacina , Humanos , Adulto , Masculino , Eletrocardiografia/efeitos dos fármacos , Método Duplo-Cego , Feminino , Pessoa de Meia-Idade , Fluoroquinolonas/efeitos adversos , Fluoroquinolonas/farmacocinética , Moxifloxacina/efeitos adversos , Moxifloxacina/farmacocinética , Frequência Cardíaca/efeitos dos fármacos , Síndrome do QT Longo/induzido quimicamente , Adulto Jovem , Fármacos Anti-HIV/farmacocinética , Fármacos Anti-HIV/efeitos adversos , Fármacos Anti-HIV/uso terapêutico , Compostos Aza/efeitos adversos , Compostos Aza/farmacocinética , Desoxiadenosinas
9.
Circulation ; 150(7): 516-530, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39051104

RESUMO

BACKGROUND: Whether vigorous exercise increases risk of ventricular arrhythmias for individuals diagnosed and treated for congenital long QT syndrome (LQTS) remains unknown. METHODS: The National Institutes of Health-funded LIVE-LQTS study (Lifestyle and Exercise in the Long QT Syndrome) prospectively enrolled individuals 8 to 60 years of age with phenotypic and/or genotypic LQTS from 37 sites in 5 countries from May 2015 to February 2019. Participants (or parents) answered physical activity and clinical events surveys every 6 months for 3 years with follow-up completed in February 2022. Vigorous exercise was defined as ≥6 metabolic equivalents for >60 hours per year. A blinded Clinical Events Committee adjudicated the composite end point of sudden death, sudden cardiac arrest, ventricular arrhythmia treated by an implantable cardioverter defibrillator, and likely arrhythmic syncope. A National Death Index search ascertained vital status for those with incomplete follow-up. A noninferiority hypothesis (boundary of 1.5) between vigorous exercisers and others was tested with multivariable Cox regression analysis. RESULTS: Among the 1413 participants (13% <18 years of age, 35% 18-25 years of age, 67% female, 25% with implantable cardioverter defibrillators, 90% genotype positive, 49% with LQT1, 91% were treated with beta-blockers, left cardiac sympathetic denervation, and/or implantable cardioverter defibrillator), 52% participated in vigorous exercise (55% of these competitively). Thirty-seven individuals experienced the composite end point (including one sudden cardiac arrest and one sudden death in the nonvigorous group, one sudden cardiac arrest in the vigorous group) with overall event rates at 3 years of 2.6% in the vigorous and 2.7% in the nonvigorous exercise groups. The unadjusted hazard ratio for experience of events for the vigorous group compared with the nonvigorous group was 0.97 (90% CI, 0.57-1.67), with an adjusted hazard ratio of 1.17 (90% CI, 0.67-2.04). The upper 95% one-sided confidence level extended beyond the 1.5 boundary. Neither vigorous or nonvigorous exercise was found to be superior in any group or subgroup. CONCLUSIONS: Among individuals diagnosed with phenotypic and/or genotypic LQTS who were risk assessed and treated in experienced centers, LQTS-associated cardiac event rates were low and similar between those exercising vigorously and those not exercising vigorously. Consistent with the low event rate, CIs are wide, and noninferiority was not demonstrated. These data further inform shared decision-making discussions between patient and physician about exercise and competitive sports participation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02549664.


Assuntos
Exercício Físico , Síndrome do QT Longo , Humanos , Síndrome do QT Longo/terapia , Síndrome do QT Longo/congênito , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/fisiopatologia , Síndrome do QT Longo/mortalidade , Feminino , Masculino , Adolescente , Criança , Estudos Prospectivos , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/epidemiologia , Fatores de Risco
10.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38970395

RESUMO

AIMS: Although electrical activity of the normal human heart is well characterized by the electrocardiogram, detailed insights into within-subject and between-subject variations of ventricular activation and recovery by noninvasive electroanatomic mapping are lacking. We characterized human epicardial activation and recovery within and between normal subjects using non-invasive electrocardiographic imaging (ECGI) as a basis to better understand pathology. METHODS AND RESULTS: Epicardial activation and recovery were assessed by ECGI in 22 normal subjects, 4 subjects with bundle branch block (BBB) and 4 with long-QT syndrome (LQTS). We compared characteristics between the ventricles [left ventricle (LV) and right ventricle (RV)], sexes, and age groups (<50/≥50years). Pearson's correlation coefficient (CC) was used for within-subject and between-subject comparisons. Age of normal subjects averaged 49 ± 14 years, 6/22 were male, and no structural/electrical heart disease was present. The average activation time was longer in LV than in RV, but not different by sex or age. Electrical recovery was similar for the ventricles, but started earlier and was on average shorter in males. Median CCs of between-subject comparisons of the ECG signals, activation, and recovery patterns were 0.61, 0.32, and 0.19, respectively. Within-subject beat-to-beat comparisons yielded higher CCs (0.98, 0.89, and 0.82, respectively). Activation and/or recovery patterns of patients with BBB or LQTS contrasted significantly with those found in the normal population. CONCLUSION: Activation and recovery patterns vary profoundly between normal subjects, but are stable individually beat to beat, with a male preponderance to shorter recovery. Individual characterization by ECGI at baseline serves as reference to better understand the emergence, progression, and treatment of electrical heart disease.


Assuntos
Potenciais de Ação , Bloqueio de Ramo , Eletrocardiografia , Síndrome do QT Longo , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/diagnóstico , Síndrome do QT Longo/fisiopatologia , Síndrome do QT Longo/diagnóstico , Frequência Cardíaca , Valor Preditivo dos Testes , Idoso , Estudos de Casos e Controles , Fatores de Tempo , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Fatores Etários , Mapeamento Epicárdico
11.
Clin Transl Sci ; 17(8): e13861, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39075882

RESUMO

Some anti-mycobacterial drugs are known to cause QT interval prolongation, potentially leading to life-threatening ventricular arrhythmia. However, the highest leprosy and tuberculosis burden occurs in settings where electrocardiographic monitoring is challenging. The feasibility and accuracy of alternative strategies, such as the use of automated measurements or a mobile electrocardiogram (mECG) device, have not been evaluated in this context. As part of the phase II randomized controlled BE-PEOPLE trial evaluating the safety of bedaquiline-enhanced post-exposure prophylaxis (bedaquiline and rifampicin, BE-PEP, versus rifampicin, SDR-PEP) for leprosy, all participants had corrected QT intervals (QTc) measured at baseline and on the day after receiving post-exposure prophylaxis. The accuracy of mECG measurements as well as automated 12L-ECG measurements was evaluated. In total, 635 mECGs from 323 participants were recorded, of which 616 (97%) were of sufficient quality for QTc measurement. Mean manually read QTc on 12L-ECG and mECG were 394 ± 19 and 385 ± 18 ms, respectively (p < 0.001), with a strong correlation (r = 0.793). The mean absolute QTc difference between both modalities was 11 ± 10 ms. Mean manual and automated 12L-ECG QTc were 394 ± 19 and 409 ± 19 ms, respectively (n = 636; p < 0.001), corresponding to moderate agreement (r = 0.655). The use of a mECG device for QT interval monitoring was feasible and yielded a median absolute QTc error of 8 ms. Automated QTc measurements were less accurate, yielding longer QTc intervals.


Assuntos
Diarilquinolinas , Eletrocardiografia , Estudos de Viabilidade , Hanseníase , Rifampina , Humanos , Diarilquinolinas/administração & dosagem , Diarilquinolinas/efeitos adversos , Masculino , Adulto , Feminino , Hanseníase/tratamento farmacológico , Hanseníase/diagnóstico , Rifampina/administração & dosagem , Rifampina/efeitos adversos , Pessoa de Meia-Idade , Hansenostáticos/efeitos adversos , Hansenostáticos/administração & dosagem , Síndrome do QT Longo/induzido quimicamente , Síndrome do QT Longo/diagnóstico , Adulto Jovem , Quimioterapia Combinada/métodos
13.
J Am Heart Assoc ; 13(14): e033619, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-38979841

RESUMO

BACKGROUND: Few small-sample studies have quantified the T-wave alternans (TWA) value by 24-hour ambulatory recordings or exercise stress tests in patients with long QT syndrome (LQTS). The cutoff point of TWA ≥47 µV was based on patients with myocardial infarction. In our study, we aimed to (1) evaluate the association of TWA with life-threatening arrhythmic events (LAEs); (2) compare the predictive model of LAEs according to the TWA value measured by 24-hour ambulatory recordings and exercise stress tests; and (3) propose a cutoff point for the high risk of LAEs in patients with LQTS. METHODS AND RESULTS: The study cohort included 110 patients with LQTS referred to our hospital, and the primary outcome was LAEs. Thirty-one patients with LQTS (31/110 [28.2%]) developed LAEs during the following 24 (12-47) months. Peak TWA value quantified from 12 leads by 24-hour ambulatory recordings in patients with LQTS with LAEs (LQTS-LAEs group) was significantly higher than LQTS without LAEs (LQTS-non-LAEs group) (64.0 [42.0-86.0] µV versus 43.0 [36.0-53.0] µV; P<0.01). There was no statistical difference in TWA value measured by exercise stress tests between the 2 groups (69.0 [54.5-127.5] µV versus 68.5 [53.3-99.8] µV; P=0.871). The new cutoff point of the peak TWA value measured by 24-hour ambulatory recordings was 55.5 µV, with a sensitivity of 75.0% and a specificity of 78.6%. A univariate Cox regression analysis revealed that TWA value ≥55.5 µV was a strong predictor of LAEs (hazard ratio [HR], 4.5 [2.1-9.6]; P<0.001]. A multivariate Cox regression analysis indicated that TWA value ≥55.5 µV remained significant (HR, 2.7 [1.1-6.8]; P=0.034). CONCLUSIONS: Peak TWA measured by 24-hour ambulatory recordings was a more favorable risk stratification marker than exercise stress tests for patients with LQTS.


Assuntos
Eletrocardiografia Ambulatorial , Teste de Esforço , Síndrome do QT Longo , Humanos , Feminino , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/fisiopatologia , Masculino , Teste de Esforço/métodos , Medição de Risco/métodos , Adulto , Eletrocardiografia Ambulatorial/métodos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Risco , Adulto Jovem , Prognóstico , Fatores de Tempo , Estudos Retrospectivos , Frequência Cardíaca/fisiologia
14.
Stem Cell Res ; 79: 103496, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39018827

RESUMO

The KCNQ1 gene encodes a voltage-gated potassium channel required for cardiac action potentials. Mutations in this gene have been associated with hereditary long QT syndrome 1, Jervell and Lange-Nielsen syndromes, and familial atrial fibrillation. The NM_000218.3(KCNQ1): c.604 + 2T > C mutation has been categorized as the causative variant leading to LQT1. In this study, we generated a KCNQ1 (c.644 + 2T > C) mutation human embryonic stem cell line WAe009-A-1L based on CRISPR base editing system. WAe009-A-1L cell has the potential to differentiate cardiomyocytes and would be used as an in vitro disease model for mechanism exploration and drug screening.


Assuntos
Edição de Genes , Células-Tronco Embrionárias Humanas , Canal de Potássio KCNQ1 , Mutação , Humanos , Células-Tronco Embrionárias Humanas/metabolismo , Células-Tronco Embrionárias Humanas/citologia , Edição de Genes/métodos , Canal de Potássio KCNQ1/genética , Canal de Potássio KCNQ1/metabolismo , Linhagem Celular , Sistemas CRISPR-Cas , Síndrome do QT Longo/genética , Síndrome do QT Longo/metabolismo , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/citologia , Diferenciação Celular , Repetições Palindrômicas Curtas Agrupadas e Regularmente Espaçadas/genética
15.
Ann Noninvasive Electrocardiol ; 29(4): e13132, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38888254

RESUMO

OBJECTIVES: This study aimed to retrospectively assess cardiac autonomic activity in children with LQTS, considering genotype, symptoms, sex, age, and beta-blocker therapy (BB) and compare it to healthy controls. METHODS: Heart rate variability (HRV), using power spectrum analysis, was analyzed in 575 Holter recordings from 116 children with LQTS and in 69 healthy children. The data were categorized into four age-groups and four heart rate (HR) ranges. RESULTS: In LQT1 and LQT2, increasing HR corresponded to significantly lower low (LF) and high frequency (HF) compared to controls. Total power (PTOT) was lower in all LQT1 age-groups compared to controls at HR 120-140 bpm (1-15 years: p < .01; 15-18 years: p = .03). At HR 80-100, LQT1 patients aged 1-10 years had lower HF than LQT2 patients (1-5 years: p = .05; 5-10 years: p = .02), and LQT2 patients aged 15-18 years had lower HF than LQT1 patients (p < .01). Symptomatic patients aged 10-15 years had lower PTOT at HR 100-120 bpm than asymptomatic patients (p = .04). LQT1 girls aged 10-15 and 15-18 years had a lower PTOT (10-15 years: p = .04; 15-18 years: p = .02) than boys. CONCLUSION: This study shows a correlation between HR and changes in HRV parameters. At higher HRs, LQTS patients generally had lower HRV values than controls, suggesting an abnormal autonomic response. These results may strengthen the link between physical activity and arrhythmias in LQTS.


Assuntos
Eletrocardiografia Ambulatorial , Frequência Cardíaca , Síndrome do QT Longo , Humanos , Adolescente , Feminino , Criança , Masculino , Frequência Cardíaca/fisiologia , Eletrocardiografia Ambulatorial/métodos , Síndrome do QT Longo/fisiopatologia , Síndrome do QT Longo/genética , Estudos Retrospectivos , Pré-Escolar , Lactente , Estudos de Casos e Controles , Antagonistas Adrenérgicos beta/uso terapêutico
16.
Br J Gen Pract ; 74(suppl 1)2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38902083

RESUMO

BACKGROUND: Opioid Agonist Treatment (OAT) is the gold standard for managing Opioid Use Disorder (OUD). It is highly effective at reducing all-cause mortality and drug-related harms. Prescribing OAT, particularly methadone, is becoming increasingly complex as Scotland's OUD population ages. Older patients, with increased polypharmacy and multimorbidity, are more susceptible to QTc interval prolongation associated with methadone use. Therefore, adherence to ECG monitoring guidelines for patients prescribed methadone is crucial, though insights from substance use services indicate suboptimal compliance. Medically Assisted Treatment guidelines established by the Scottish Government advocate for shared care agreements, thus transferring OAT prescribing responsibilities to primary care. Understanding ECG monitoring guideline implementation in non-specialist services is vital for developing safe OAT services in primary care. AIM: This audit assessed adherence to NICE guidelines for ECG monitoring in OUD patients prescribed methadone in a Scottish primary care practice. METHOD: The notes of patients prescribed methadone were assessed using NICE criteria to determine eligibility for ECG monitoring. Eligible patients' medical records were reviewed to identify previous ECG investigations. RESULTS: Of 21 patients prescribed methadone, 16 qualified for ECG monitoring. Only 25% of eligible patients received ECG monitoring per NICE guideline, meaning 75% did not. CONCLUSION: These findings highlight that the issue of poor compliance with ECG monitoring guidelines is not limited to specialist services, but also affects primary care. Further exploration of barriers to guideline implementation is essential. Perhaps more resources are needed to integrate OAT services into primary care, which has taken on increased responsibilities without corresponding investment.


Assuntos
Eletrocardiografia , Fidelidade a Diretrizes , Metadona , Tratamento de Substituição de Opiáceos , Transtornos Relacionados ao Uso de Opioides , Atenção Primária à Saúde , Humanos , Metadona/uso terapêutico , Escócia , Transtornos Relacionados ao Uso de Opioides/tratamento farmacológico , Transtornos Relacionados ao Uso de Opioides/diagnóstico , Feminino , Masculino , Tratamento de Substituição de Opiáceos/métodos , Adulto , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Síndrome do QT Longo/induzido quimicamente , Síndrome do QT Longo/diagnóstico , Analgésicos Opioides/uso terapêutico , Analgésicos Opioides/efeitos adversos
17.
J Coll Physicians Surg Pak ; 34(6): 659-666, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38840347

RESUMO

OBJECTIVE: To evaluate the effect of favipiravir administered to diabetic and non-diabetic COVID-19 patients on the QT/QTc interval. STUDY DESIGN: Analytical study. Place and Duration of the Study: Republic of Turkey, Ministry of Health, State Hospital, Corlu, Tekirdag, Turkiye, from March to September 2021. METHODOLOGY: Electrocardiogram (ECG) analysis was performed on all participants (n=180) divided into four groups. Group 1 included only healthy volunteers. Group 2 included only cases diagnosed with T2DM. Group 3 included only severe acute respiratory syndrome coronavirus-2 (SARS-Cov-2) cases. Group 4 included cases diagnosed with both SARS and T2DM. Favipiravir was administered only to the cases in Group 3 and Group 4. In the cases that were administered favipiravir, the QT/QTc interval was calculated and recorded at different time intervals on the first and fifth days of the therapy. The difference between groups was determined by Tukeye's test after ANOVA. Pearson's correlation test was used to determine whether there was a linear relationship between two numericals. The alpha significance value was determined to be <0.05 in all statistical analyses. RESULTS: When all groups were compared, it was seen that both QT and QTc values ​​increased in Groups 3 and 4, which were administered favipiravir (p <0.05). Favipiravir may cause an increased risk of ventricular and atrial arrhythmias. CONCLUSION: Favipiravir may cause QT interval prolongation, particularly in SARS-Cov-2 patients diagnosed with T2DM. KEY WORDS: COVID-19, Drug-induced long QT syndrome, Intra-infarct haemorrhage; Favipiravir, Type 2 diabetes mellitus.


Assuntos
Amidas , Antivirais , Tratamento Farmacológico da COVID-19 , COVID-19 , Diabetes Mellitus Tipo 2 , Eletrocardiografia , Síndrome do QT Longo , Pirazinas , SARS-CoV-2 , Humanos , Pirazinas/uso terapêutico , Pirazinas/efeitos adversos , Amidas/uso terapêutico , Amidas/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Diabetes Mellitus Tipo 2/tratamento farmacológico , Antivirais/uso terapêutico , Antivirais/efeitos adversos , COVID-19/complicações , Síndrome do QT Longo/induzido quimicamente , Adulto , Turquia , Idoso
18.
J Pharmacol Toxicol Methods ; 128: 107525, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38851600

RESUMO

INTRODUCTION: Nonclinical evaluation of the cardiovascular effects of novel chemical or biological entities (NCE, NBEs) is crucial for supporting first-in-human clinical trials. One important aspect of these evaluations is the assessment of potential QT/QTc prolongation risk, as drug-induced QT prolongation can have catastrophic effects. The recent publication of E14/S7B Q&As allows for the situational incorporation of nonclinical QTc data as part of an integrated risk assessment for a Thorough QT (TQT) waiver application provided certain best practice criteria are met. Recent publications provided detailed characterization of nonclinical QTc telemetry data collected from the commonly used Latin square study design. METHODS: To understand whether data from alternate telemetry study designs were sufficient to serve as part of the E14/S7B integrated risk assessment, we report the performance and translational sensitivity to identify clinical risk of QTc prolongation risk for an ascending dose telemetry design. RESULTS: The data demonstrated low variability in QTci interval within animals from day to day, indicating a well-controlled study environment and limited concern for uncontrolled effects across dosing days. Historical study variances of the ascending dose design with n = 4 subjects, measured by least significant difference (LSD) and root mean square error (RMSE) values, were low enough to detect a + 10 ms QTci interval change, and the median minimum detectable difference (MDD) for QTci interval changes was <10 ms. Furthermore, concentration-QTci (C-QTci) assessments to determine +10 ms QTci increases for known hERG inhibitors were comparable to clinical CC values listed in the E14/S7B training materials, supporting the use of the ascending dose design in an E14/S7B integrated risk assessment. DISCUSSION: These findings suggest that the ascending dose design can be a valuable tool in nonclinical evaluation of QT/QTc prolongation risk and the support of TQT waiver applications.


Assuntos
Relação Dose-Resposta a Droga , Eletrocardiografia , Síndrome do QT Longo , Telemetria , Animais , Telemetria/métodos , Medição de Risco/métodos , Síndrome do QT Longo/induzido quimicamente , Cães , Eletrocardiografia/métodos , Eletrocardiografia/efeitos dos fármacos , Masculino , Avaliação Pré-Clínica de Medicamentos/métodos , Frequência Cardíaca/efeitos dos fármacos , Feminino
19.
J Pharmacol Toxicol Methods ; 128: 107528, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38852684

RESUMO

INTRODUCTION: In preclinical cardiovascular safety pharmacology studies, statistical analysis of the rate corrected QT interval (QTc) is the focus for predicting QTc interval changes in the clinic. Modeling of a concentration/QTc relationship, common clinically, is limited due to minimal pharmacokinetic (PK) data in nonclinical testing. It is possible, however, to relate the average drug plasma concentration from sparse PK samples over specific times to the mean corrected QTc. We hypothesize that averaging drug plasma concentration and the QTc-rate relationship over time provides a simple, accurate concentration-QTc relationship bridging statistical and concentration/QTc modeling. METHODS: Cardiovascular telemetry studies were conducted in non-human primates (NHP; n = 48) and canines (n = 8). Pharmacokinetic samples were collected on separate study days in both species. Average plasma concentrations for specific intervals (CAverage0-X) were calculated for moxifloxacin in canines and NHP using times corresponding to super-intervals for the QTc data statistical analysis. The QTc effect was calculated for each super-interval using a linear regression correction incorporating QT and HR data from the whole super-interval. The concentration QTc effects were then modeled. RESULTS: In NHP, a 10.9 ± 0.06 ms (mean ± 95% CI) change in QTc was detected at approximately 1.5× the moxifloxacin plasma concentration that causes a 10 ms QTc change in humans, based on a 0-24 h super-interval. When simulating a drug without QT effects, mock, no effect on QTc was detected at up to 3× the clinical concentration. Similarly, in canines, a 16.6 ± 0.1 ms change was detected at 1.7× critical clinical moxifloxacin concentration, and a 0.04 ± 0.1 ms change was seen for mock. CONCLUSIONS: While simultaneous PK and QTc data points are preferred, practical constraints and the need for QTc averaging did not prevent concentration-QTc analyses. Utilizing a 0-24 h super-interval method illustrates a simple and effective method to address cardiovascular questions when preclinical drug exposures exceed clinical concentrations.


Assuntos
Eletrocardiografia , Síndrome do QT Longo , Moxifloxacina , Telemetria , Animais , Cães , Moxifloxacina/farmacocinética , Moxifloxacina/administração & dosagem , Eletrocardiografia/efeitos dos fármacos , Eletrocardiografia/métodos , Telemetria/métodos , Síndrome do QT Longo/induzido quimicamente , Avaliação Pré-Clínica de Medicamentos/métodos , Fluoroquinolonas/farmacocinética , Fluoroquinolonas/administração & dosagem , Frequência Cardíaca/efeitos dos fármacos , Masculino , Modelos Animais , Relação Dose-Resposta a Droga , Feminino
20.
J Pharmacol Toxicol Methods ; 128: 107527, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38852685

RESUMO

INTRODUCTION: Cardiovascular safety and the risk of developing the potentially fatal ventricular tachyarrhythmia, Torsades de Pointes (TdP), have long been major concerns of drug development. TdP is associated with a delayed ventricular repolarization represented by QT interval prolongation in the electrocardiogram (ECG), typically due to block of the potassium channel encoded by the human ether-a-go-go related gene (hERG). Importantly however, not all drugs that prolong the QT interval are torsadagenic and not all hERG blockers prolong the QT interval. Recent clinical reports suggest that partitioning the QT interval into early (J to T peak; JTp) and late repolarization (T peak to T end; TpTe) components may be valuable for distinguishing low-risk mixed ion channel blockers (hERG plus calcium and/or late sodium currents) from high-risk pure hERG channel blockers. This strategy, if true for nonclinical animal models, could be used to de-risk QT prolonging compounds earlier in the drug development process. METHODS: To explore this, we investigated JTp and TpTe in ECG data collected from telemetered dogs and/or monkeys administered moxifloxacin or amiodarone at doses targeting relevant clinical exposures. An optimized placement of the Tpeak fiducial mark was utilized, and all intervals were corrected for heart rate (QTc, JTpc, TpTec). RESULTS: Increases in QTc and JTpc intervals with administration of the pure hERG blocker moxifloxacin and an initial QTc and JTpc shortening followed by prolongation with the mixed ion channel blocker amiodarone were detected as expected, aligning with clinical data. However, anticipated increases in TpTec by both standard agents were not detected. DISCUSSION: The inability to detect changes in TpTec reduces the utility of these subintervals for prediction of arrhythmias using continuous single­lead ECGs collected from freely moving dogs and monkeys.


Assuntos
Amiodarona , Eletrocardiografia , Síndrome do QT Longo , Moxifloxacina , Torsades de Pointes , Animais , Moxifloxacina/administração & dosagem , Moxifloxacina/farmacologia , Cães , Amiodarona/administração & dosagem , Amiodarona/farmacologia , Eletrocardiografia/efeitos dos fármacos , Eletrocardiografia/métodos , Torsades de Pointes/induzido quimicamente , Síndrome do QT Longo/induzido quimicamente , Síndrome do QT Longo/fisiopatologia , Masculino , Canais de Potássio Éter-A-Go-Go/antagonistas & inibidores , Canais de Potássio Éter-A-Go-Go/metabolismo , Feminino , Macaca fascicularis , Fluoroquinolonas/administração & dosagem , Fluoroquinolonas/farmacologia , Frequência Cardíaca/efeitos dos fármacos , Bloqueadores dos Canais de Potássio/administração & dosagem , Bloqueadores dos Canais de Potássio/farmacologia , Canal de Potássio ERG1/antagonistas & inibidores , Canal de Potássio ERG1/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...