Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 467
Filtrar
1.
Braz Oral Res ; 38: e053, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38922213

RESUMO

To evaluate the effect of acidic challenge on erosion depth and topographic characteristics of different materials used as occlusal sealants. Two hundred specimens of five sealant materials (Fuji IX, Ketac Molar, Fuji II, Equia and Clinpro) and forty bovine teeth enamel samples (control) were prepared and exposed to acidic challenge. The specimens were immersed in four different solutions (orange juice, coke drink, citric acid or distilled water) under mildly shaken conditions for 3 days. The erosion depth profiles were measured using a profilometer and Scanning Electron Microscope (SEM). Two-way ANOVA with Tukey post-hoc test was performed to evaluate the interactions. Sealant material and acidic challenge had significant effects on erosion depth. Among the materials, Fuji II presented the highest mean of erosion depth after immersion in orange juice, coke drink, and citric acid. All materials groups presented higher erosion depth values after immersion in the citric acid solution, except Clinpro. Bovine enamel presented higher erosion depth values compared to all materials when submitted to erosive challenge. Sealant materials submitted to the acidic challenge presented different degrees of erosion and topographic modification; however, they are less susceptible to erosion than bovine teeth enamel.


Assuntos
Ácido Cítrico , Esmalte Dentário , Teste de Materiais , Microscopia Eletrônica de Varredura , Selantes de Fossas e Fissuras , Propriedades de Superfície , Erosão Dentária , Bovinos , Animais , Erosão Dentária/prevenção & controle , Erosão Dentária/induzido quimicamente , Esmalte Dentário/efeitos dos fármacos , Selantes de Fossas e Fissuras/química , Análise de Variância , Fatores de Tempo , Propriedades de Superfície/efeitos dos fármacos , Cimentos de Ionômeros de Vidro/química , Cimentos de Ionômeros de Vidro/uso terapêutico , Reprodutibilidade dos Testes , Bebidas Gaseificadas/efeitos adversos , Valores de Referência , Concentração de Íons de Hidrogênio , Resinas Compostas/química
2.
Dent Mater J ; 43(3): 346-358, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38583998

RESUMO

Conventional resin-based sealants release minimal fluoride ions (F) and lack antibacterial activity. The objectives of this study were to: (1) develop a novel bioactive sealant containing calcium fluoride nanoparticles (nCaF2) and antibacterial dimethylaminohexadecyl methacrylate (DMAHDM), and (2) investigate mechanical performance, F recharge and re-release, microleakage, sealing ability and cytotoxicity. Helioseal F served as commercial control. The initial F release from sealant containing 20% nCaF2 was 25-fold that of Helioseal F. After ion exhaustion and recharge, the F re-release from bioactive sealant did not decrease with increasing number of recharge and re-release cycles. Elastic modulus of new bioactive sealant was 44% higher than Helioseal F. The new sealant had excellent sealing, minimal microleakage, and good cytocompatibility. Hence, the nanostructured sealant had substantial and sustained F release and antibacterial activity, good sealing ability and biocompatibility. The novel bioactive nCaF2 sealant is promising to provide long-term F ions for caries prevention.


Assuntos
Antibacterianos , Fluoreto de Cálcio , Infiltração Dentária , Teste de Materiais , Metacrilatos , Nanopartículas , Selantes de Fossas e Fissuras , Selantes de Fossas e Fissuras/química , Antibacterianos/farmacologia , Antibacterianos/química , Fluoreto de Cálcio/química , Metacrilatos/química , Nanopartículas/química , Fluoretos/química , Fluoretos/farmacologia , Módulo de Elasticidade , Animais , Camundongos , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Propriedades de Superfície , Resinas Compostas
3.
J Biomater Appl ; 36(4): 731-739, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33940972

RESUMO

Different types of wounds have different requirements of a wound sealant. One of the requirements of concern is the adaptability of the mechanical properties of biomaterials to native tissues. However, the mechanical properties of current sealant are untunable or adjustable in a small range normally. Therefore, the scope of application of these sealant is limited. In this study, we developed hyperbranched polyester (HBP)-based UV-curable sealant with tunable mechanical properties. This sealant was cured under UV-light for 2 minutes and exhibited strong adhesion with tissues. The shear adhesive strength of it to the porcine skin ranged between 20-30 kPa, which was higher than the fibrin glue (∼10 kPa). Moreover, the elastic modulus of the sealant in a tensile test ranged between 27-54 MPa, depending on the degree of acrylation of the HBPs. Additionally, we assessed the biocompatibility of the sealant by co-culturing it with mouse mesenchymal stem cells (mMSCs) for 7 days and discovered that the cell viability was unaffected. This sealant with a tunable elastic modulus might be a promising candidate for treating wounds with different elastic moduli.


Assuntos
Materiais Biocompatíveis/química , Fenômenos Mecânicos , Selantes de Fossas e Fissuras/química , Poliésteres/química , Cicatrização , Animais , Adesivo Tecidual de Fibrina , Camundongos , Resistência à Tração , Aderências Teciduais , Adesivos Teciduais
4.
PLoS One ; 15(11): e0241272, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33151995

RESUMO

To assess- the release of calcium and phosphate ions from a fissure sealant containing amorphous calcium phosphate (ACP), and to determine the re-release capacity of these ions when charged with a solution containing casein phosphopeptide-amorphous calcium phosphate (CPP-ACP). Nine blocks of ACP resin-based sealant were prepared and immersed in three solutions at different pH (4.0, 5.5, 7.0), and calcium and phosphate ion release was measured with ion chromatography at 1, 3, 5, 7, 14, 21 and 28 days after immersion. Sixty days after immersion, each block was charged with CPP-ACP solution in three 7-day cycles to investigate the re-release of these ions, which was measured on days 1, 3, and 7. No difference was observed in initial calcium ion release at pH 4.0 and pH 5.5. At both values, ion release was significantly higher than at pH 7.0 (p<0.001). Initial phosphate release was significantly different among the three pH values (p<0.001). After re-charging the specimens, calcium ion re-release was greater than phosphate ion release. Initial ion release from ACP resin-based sealant was greatest at the lowest pH. Ion release decreased with time. As the number of recharge cycles increased, ion re-release also improved. Phosphate ion re-release required more recharge cycles than calcium ion re-release.


Assuntos
Fosfatos de Cálcio/química , Selantes de Fossas e Fissuras/química , Cálcio/química , Concentração de Íons de Hidrogênio , Íons , Fosfatos/química
5.
Biofouling ; 36(3): 245-255, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32326753

RESUMO

Dental plaque is a biofilm composed of a complex oral microbial community. The accumulation of plaque in the pit and fissures of dental elements often leads to the development of tooth decay (dental caries). Here, potent anti-biofilm materials were developed by incorporating zinc methacrylates or di-n-butyl-dimethacrylate-tin into the light-curable sealant and their physical, mechanical, and biological properties were evaluated. The data revealed that 5% di-n-butyl-dimethacrylate-tin (SnM 5%) incorporated sealant showed strong anti-biofilm efficacy against various single-species (Streptococcus mutans or Streptococcus oralis or Candida albicans) and S. mutans-C. albicans cross-kingdom dual-species biofilms without either impairing the mechanical properties of the sealant or causing cytotoxicities against mouse fibroblasts. The findings indicate that the incorporation of SnM 5% in the experimental pit and fissure self-adhesive sealant may have the potential to be part of current chemotherapeutic strategies to prevent the formation of cariogenic oral biofilms that cause dental caries.


Assuntos
Adesivos/farmacologia , Biofilmes/efeitos dos fármacos , Cárie Dentária/prevenção & controle , Selantes de Fossas e Fissuras/farmacologia , Zinco/química , Adesivos/química , Animais , Biofilmes/crescimento & desenvolvimento , Candida albicans/efeitos dos fármacos , Candida albicans/crescimento & desenvolvimento , Cárie Dentária/microbiologia , Humanos , Metacrilatos/química , Camundongos , Microbiota/efeitos dos fármacos , Selantes de Fossas e Fissuras/química , Streptococcus mutans/efeitos dos fármacos , Streptococcus mutans/crescimento & desenvolvimento , Streptococcus oralis/efeitos dos fármacos , Streptococcus oralis/crescimento & desenvolvimento
6.
Artigo em Inglês | BBO, LILACS | ID: biblio-1135522

RESUMO

Abstract Objective: To compare the immediate microleakage of carious fissures sealed with a caries infiltrant covered by a flowable composite or solely with a flowable composite. Material and Methods: Extracted carious molars (n=20) were selected and paired among the experimental groups according to caries progression scores. Experimental groups (n=10) were divided according to the following sealing techniques: 1) caries infiltrant (Icon) + flowable composite (Z350 flow); 2) flowable composite (Z350 flow). Specimens were immersed in 3% methylene blue and evaluated in a stereomicroscope. Microleakage scores were attributed independently by two calibrated evaluators and the mode value was considered as the mean for the specimen. Binomial tests were used to test differences between two independent sample proportions at 5% significance level. Results: In the flowable composite group, a higher prevalence of dye penetration along the full depth of the fissure was observed, compared with caries infiltrant + flowable composite (p<0.05). For specimens showing dye penetration up to half of the fissure, in caries infiltrant + flowable composite group, all specimens showed dye penetration into the sealant, but not over the infiltrant. Conclusion: Using caries infiltrant as sealing material under a flowable composite cover is effective to improve the immediate sealing ability in carious fissures compared to sealing with flowable composite.


Assuntos
Humanos , Selantes de Fossas e Fissuras/química , Cárie Dentária/prevenção & controle , Infiltração Dentária/diagnóstico por imagem , Materiais Dentários/química , Dente Molar , Brasil , Azul de Metileno
7.
Braz Oral Res ; 33: e101, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31778472

RESUMO

The aim of this study was to evaluate the influence of different calcium phosphates (CaPs) on the physical, biological, and remineralizing properties of experimental resin-based sealants (RBSs). Triethylene-glycol dimethacrylate (90wt%) and bisphenol A-glycidyl methacrylate (10wt%) were used to produce resin-based sealants. Hydroxyapatite (SHAp), α-tricalcium phosphate (Sα-TCP) and octacalcium phosphate (SOCP) were added to the sealants in a 10wt% concentration. One group without CaPs was used as the control group (SCG). The degree of conversion (DC) was assessed with Fourier-transformed infrared spectroscopy, whereas cytotoxicity was tested with the HaCaT keratinocyte cell line. The ultimate tensile strength (UTS) was used to assess the mechanical strength of the experimental RBSs. Sealed enamel was used for colorimetric assay. Mineral deposition was assessed with Raman spectroscopy after 7, 14, and 28 days of sample immersion in artificial saliva. Scanning electron microscopy was used to analyze the surface morphology after 28 days of immersion. The addition of 10wt% of fillers significantly reduced the DC of sealants. SOCP groups showed reduced cell viability. Higher UTS was found for Sα-TCP and SHAp. The color analysis showed that SGC and demineralized teeth presented higher mismatches with the sound tissue. Mineral deposition was observed for SHAp and Sα-TCP after 7 days, with increased phosphate content and mineral deposits for SHAp after 28 days. RBS with the addition of 10% HAp promoted increased mineralization in vitro after 28 days, and did not affect cell viability, DC, mechanical properties, or RBS color in the enamel.


Assuntos
Fosfatos de Cálcio/química , Durapatita/química , Minerais/química , Selantes de Fossas e Fissuras/química , Resinas Sintéticas/química , Animais , Fosfatos de Cálcio/toxicidade , Bovinos , Linhagem Celular , Colorimetria , Esmalte Dentário/química , Esmalte Dentário/efeitos dos fármacos , Durapatita/toxicidade , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Selantes de Fossas e Fissuras/toxicidade , Valores de Referência , Reprodutibilidade dos Testes , Resinas Sintéticas/toxicidade , Saliva Artificial/química , Análise Espectral Raman , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo
8.
J Dent ; 88: 103163, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31276747

RESUMO

OBJECTIVES: Although there is some consensus that carious lesions in early stages (non-cavitated) could be treated using sealants, neither the type of materials nor their use in lesions with localized enamel breakdown (microcavitated) has been reported To compare the efficacy of resin or glass ionomer (GI) sealants in arresting microcavitated carious lesions (ICDAS 3) in first permanent molars. MATERIALS AND METHODS: A double-blinded randomized controlled clinical trial was conducted in 41 healthy 6 to 11-year-old children. At the baseline examination, each subject had at least one carious lesion classified as ICDAS 3 on the first permanent molar. One hundred fifty-one lesions were randomized into: Group 1: resin sealants (76 lesions) and Group 2: GI sealant (75 lesions). Carious lesion progression was assessed clinically and radiographically. Progression and retention failure were the outcomes used for group comparisons at p-value<0.05. RESULTS: After a two-year follow-up, only one lesion progressed to ICDAS 5, without statistically significant differences between the groups (χ2(1) = 0.90, p = 0.53). Radiographically, 100 lesions (98%) were arrested and 2 (2%) showed radiographic progression, without differences between groups (χ2(1) = 0.93, p = 0.93). At 2 years, complete retention was observed in 77% of the resin-based and in 83% of the GI sealants, without statistical differences between type of sealant (χ2(1) = 0.71, p = 0.48). The multilevel mixed model demonstrated that location and type of sealant did not affect retention rates (χ2(1) = 24,98, p < 0.001). CONCLUSION: Sealing ICDAS 3 carious lesions in permanent molars appears to be effective in arresting lesions after a two-year follow-up. Clinicaltrials.gov: RCTICDAS3/2015. CLINICAL SIGNIFICANCE: Minimally invasive approaches for carious lesion management have been promoted. Using sealants for the treatment of microcavitated lesions (ICDAS 3) appears predictable in the routine practice, without predilection for resin or glass ionomer materials. In addition to preserving tooth structure, this strategy reduces chair-time, dental fear and costs, and increases coverage to dental care.


Assuntos
Resinas Acrílicas/uso terapêutico , Cárie Dentária/prevenção & controle , Cimentos de Ionômeros de Vidro/uso terapêutico , Selantes de Fossas e Fissuras/uso terapêutico , Resinas Acrílicas/química , Criança , Resinas Compostas/química , Resinas Compostas/uso terapêutico , Método Duplo-Cego , Cimentos de Ionômeros de Vidro/química , Humanos , Dente Molar/patologia , Selantes de Fossas e Fissuras/química , Dióxido de Silício
9.
Biomed Res Int ; 2019: 5070383, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31032348

RESUMO

This research evaluated the effects of subpressure on the shear bond strength (SBS) of 80 specimens with flat enamel surfaces and on AgNO3 microleakage of 40 specimens with flat enamel surfaces and 40 specimens with 1 mm deep cavities before and after thermocycling. The enamel of 168 specimens was grounded to a flat surface. Two types of sealants (E and H) were selected. Sealants were applied to enamel surface (88 specimens, group F) either subjected or not to subpressure. The bonding interfaces were observed using scanning electron microscopy (SEM) and the SBS was examined using a universal testing machine before and after thermocycling. The failure mode was also analyzed. For the microleakage test, 80 specimens were grouped as group A (original enamel flat surface) and group B (a round cavity of 1 mm in depth) (40 per group). Sealants were applied to the teeth either subjected or not to subpressure. The specimens were submitted to a microleakage protocol with AgNO3 and analyzed before and after thermocycling. Statistical analysis was performed for the data. The results showed that subpressure eliminated voids on the interface between the enamel and sealants and significantly enhanced specimens' SBS. Although thermocycling reduced SBS significantly, specimens under subpressure after thermocycling still showed higher SBS than specimens under nonsubpressure before thermocycling. The subpressure groups showed a lower microleakage level compared to nonsubpressure groups, though thermocycling caused deeper silver infiltration. In addition, different sealants showed no significant effect on the SBS and microleakage performance. Overall, subpressure application improves sealant bonding and retention rate and has potential to prevent secondary caries.


Assuntos
Cárie Dentária/prevenção & controle , Cárie Dentária/terapia , Esmalte Dentário/efeitos dos fármacos , Selantes de Fossas e Fissuras/uso terapêutico , Condicionamento Ácido do Dente/métodos , Colagem Dentária/métodos , Cárie Dentária/patologia , Esmalte Dentário/fisiopatologia , Análise do Estresse Dentário , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Dente Molar/efeitos dos fármacos , Selantes de Fossas e Fissuras/química , Cimentos de Resina/química , Cimentos de Resina/uso terapêutico , Resistência ao Cisalhamento , Propriedades de Superfície
10.
J Appl Biomater Funct Mater ; 17(1): 2280800018816013, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30803291

RESUMO

INTRODUCTION:: The technique of sealing is a widely accepted procedure for prevention of caries. The aim of our in vitro study was to compare the effect of two different curing units (traditional LED source and innovative laser diode lamp) on the integrity of fissure sealant material and its interface with tooth enamel. MATERIALS AND METHODS:: Sixty healthy third molars were randomly assigned to two groups. In group A were teeth intended for polymerization by LED B lamp, and group B comprised teeth to be polymerized by an innovative laser diode. Both groups were treated with the traditional sealing technique, subjected to a metallization process, and analyzed by scanning electron microscope. RESULTS:: Micro-gaps between the sealant and the enamel were found in specimens in both A (43%) and B (40%) groups ( p=0.793), and sealant shrinkage was seen. Significant differences between the groups emerged in the percentage of perimetric micro-erosion sites (80% vs. 100%, p=0.010) and the presence of holes and micro-bubbles on the sealant surface (21% vs. 63%, p=0.001). CONCLUSIONS:: Although macroscopic clinical polymerization occurred with both instruments, the microscopic evaluation showed significant differences between the studied groups in terms of perimetric micro-erosion sites and micro-bubbles, which were higher in laser-cured samples.


Assuntos
Lasers , Luz , Selantes de Fossas e Fissuras/química , Esmalte Dentário/ultraestrutura , Polimerização/efeitos da radiação , Propriedades de Superfície
11.
Eur J Paediatr Dent ; 19(4): 333-334, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30567453

RESUMO

BACKGROUND: Bisphenol A (BPA) is a synthetic chemical resin used worldwide to produce plastic products. It is also a component of the bisphenol A diglycidylether methacrylate (Bis-GMA), which is a monomer found in dental resin-based materials (including resin-based dental sealants, RBSs). The controversy about its possible toxicity begins around the early '30s. Even if the amount of BPA released by dental sealants is well below the limit proposed by the U.S. Environmental Protection Agency and the European Food Safety Authority, we can reduce the risk of exposure, particularly for children, following precautionary measures.


Assuntos
Compostos Benzidrílicos/toxicidade , Assistência Odontológica para Crianças , Fenóis/toxicidade , Selantes de Fossas e Fissuras/toxicidade , Compostos Benzidrílicos/química , Criança , Humanos , Fenóis/química , Selantes de Fossas e Fissuras/química , Resinas Sintéticas/química , Resinas Sintéticas/toxicidade
12.
Dent Mater J ; 37(6): 981-987, 2018 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-30298854

RESUMO

The aim of this study was to evaluate nanoleakage within the different lesion-sealing therapies applied to artificial non-cavitated enamel lesions. Thirty-two human anterior teeth were used. Artificial subsurface enamel lesions were produced on the labial surfaces of teeth. The specimens were then randomly divided into three groups (n=10): Group I- Clinpro Sealant application; Group II- ExciTE F adhesive resin application; and Group III- ICON resin infiltrant application. Each group was further divided into two subgroups: control and thermocycler. Nanoleakage was calculated by the digital image analysis software. In the control and thermocycled groups, there was no statistically significant difference between the Groups I, II, and III (p>0.05). The only significant leakage scores were obtained between the Group III control and thermocycler groups (p=0.027). ICON infiltrant can be used as an alternative to dental adhesives and fissure sealants in the sealing of initial non-cavitated enamel lesions. But the resin may become more affected by the water sorption than other resin materials over time. More studies are needed to evaluate long-term durability of resin infiltrants.


Assuntos
Resinas Compostas/química , Cimentos Dentários/química , Esmalte Dentário/efeitos dos fármacos , Esmalte Dentário/ultraestrutura , Infiltração Dentária , Selantes de Fossas e Fissuras/química , Resinas Sintéticas/química , Humanos , Técnicas In Vitro , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície
13.
J Chromatogr A ; 1576: 90-100, 2018 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-30266234

RESUMO

Since 2011, the World Health Organization has encouraged a global phase-down of the use of dental amalgam and actively supported the use of alternative, resin-based dental materials. The resins consist of (meth)acrylate monomers derived from Bisphenol A (BPA), such as Bisphenol A glycidyl methacrylate (BisGMA) and Bisphenol A ethoxylate methacrylate (BisEMA) or triethylene glycol dimethacrylate (TEGDMA) and urethane dimethacrylate (UDMA) which lack the BPA backbone. Besides monomers, other compounds such as photoinitiators and stabilizing agents can be present in the dental resin matrices. The current study consists in the development of an analytical method for the separation and identification of dental material components using LC-QTOF-MS. The developed method was applied on several dental material ingredients, unpolymerized composite resins, and a common dental sealant. The acquired high resolution accurate-mass data was analyzed using suspect screening with an in-house developed library. Next to the main components, various isomers and impurities related to the production of the main component have been detected and identified in the dental material ingredients. In total, 39 chemicals have been identified in the analyzed dental materials. On average 15 chemicals have been identified. Major components, such as BisEMA, BisGMA and TEGDMA were identified although they were not always stated in the material safety data sheets. Minor components included photoinitiators, such as ethyl 4-dimethyl aminobenzoate (EDMAB) and (meth)acrylates impurities originating from production of main ingredients.


Assuntos
Cromatografia Líquida , Resinas Compostas/química , Materiais Dentários/química , Espectrometria de Massas , Teste de Materiais/métodos , Selantes de Fossas e Fissuras/química
14.
Eur J Paediatr Dent ; 19(3): 247-249, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30063160

RESUMO

Determining the best choice between the different sealant materials might be complicated. The products that dentists can choose have different properties, such as caries' preventive effect, fluoride release and retention rate. According to the literature, fissure sealant materials fall into two main categories: resin-based sealants and glass ionomer sealants. Even if the "fluoride-releasing resin sealants" are better than "glass ionomer", with regards to retention of the material, the literature shows that their effectiveness in preventing fissure caries in permanent molars does not differ significantly over 24 months.


Assuntos
Cárie Dentária/prevenção & controle , Selantes de Fossas e Fissuras/química , Selantes de Fossas e Fissuras/uso terapêutico , Resinas Acrílicas/química , Resinas Acrílicas/uso terapêutico , Criança , Cimentos de Ionômeros de Vidro/química , Cimentos de Ionômeros de Vidro/uso terapêutico , Humanos
15.
Food Chem Toxicol ; 120: 536-543, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30076914

RESUMO

The aim of this study was to identify organic components eluted from five resin dental sealants using gas chromatography and mass spectrometry (GC/MS) after 1-day and 40-days storage and the effect of sealants on cell survival of cultured fibroblasts. Five resin materials were studied: BeautiSealant (SHOFU), Clinpro (3M/ESPE), Conseal F (SDI), Grandio Seal (VOCO) and Helioseal Clear (Ivoclar/Vivadent). The organic monomers detected were butylated hydroxytoluene (BHT), bis-phenol-A (BPA), camphoroquinone (CQ), diethylenglycoldimethacrylate (DEGDMA), 4N, N-dimethylaminobenzoic acid butylethoxyester (DMABEE), hydroxyethylmethcrylate (HEMA), hydroquinone monomethylether (MEHQ), triethylene glycol dimethacrylate (TEGDMA), tetrabutylammonium tetrafluoroborate (TBATFB), triphenylstibane (TPSb). The main monomer detected was TEGDMA, whereas BHT and DEGDMA were detected at lower concentrations. Higher monomer concentrations were detected after 40 days storage. The eluting chemical profiles of the tested materials differ qualitative and quantitative. For cytotoxicity evaluation, NIH/3T3 cells were exposed to eluates of sealants and cell viability was assessed by a quantitative technique at two observation periods. Decreased cell viability was observed. The cytotoxicity and the release of monomers from dental materials examined depends on the type of material and the observation time point. Resin-based dental materials have raised public concerns regarding possible adverse biological effects, thus it is essential to evaluate possible side effects for human health.


Assuntos
Compostos Orgânicos/química , Compostos Orgânicos/toxicidade , Selantes de Fossas e Fissuras/química , Selantes de Fossas e Fissuras/toxicidade , Animais , Cromatografia Gasosa-Espectrometria de Massas , Camundongos , Células NIH 3T3 , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química
16.
Clin Oral Investig ; 22(9): 3143-3157, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29524024

RESUMO

OBJECTIVE: Optical coherence tomography (OCT) is a clinical standard in ophthalmology. Currently, its application in dentistry is gaining increasing interest. In this study, we tested the possibility to use a modified commercially available spectral domain OCT (SD-OCT) to assess the layer thickness of orthodontic surface sealants. MATERIALS AND METHODS: Reference samples of surface sealants for calibration and repeatability testing were measured using a micrometer screw. SD-OCT measurements were compared with micro-CT and light microscopic analyses. After validating the calibration of the SD-OCT, surface sealant layer thickness after aging (thermo cycling) and simulation of professional tooth cleaning (PTC) was assessed using the SD-OCT on 45 extracted teeth assigned to three test groups (n = 15 each): Light Bond™ Sealant, Pro Seal®, and Opal® Seal. RESULTS: SD-OCT showed excellent repeatability and accuracy for measurements of surface sealant layer thickness. Compared with micro-CT, SD-OCT showed better accordance with the reference measurements. The analysis of surface sealants after thermo cycling and PTC revealed poor resistance of Light Bond after only aging and demonstrated substantial wear of all sealants after aging and PTC. CONCLUSION: Imaging using commercially available ophthalmic SD-OCT might represent a suitable non-invasive methodology for longitudinal assessments of surface sealant layer thickness in vitro and in vivo. CLINICAL RELEVANCE: SD-OCT might be a suitable non-invasive method for longitudinal assessments of surface sealant durability in clinical trials.


Assuntos
Selantes de Fossas e Fissuras/química , Tomografia de Coerência Óptica/instrumentação , Resinas Compostas , Humanos , Técnicas In Vitro , Teste de Materiais , Reprodutibilidade dos Testes , Cimentos de Resina , Propriedades de Superfície , Microtomografia por Raio-X
17.
Dent Mater J ; 37(1): 104-112, 2018 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-28954939

RESUMO

This study compared resin-based and glass ionomer sealants with regard to their fluoride-release behavior and anti-demineralization potential on adjacent unsealed enamel surfaces. Sealant cavities prepared on bovine enamel blocks were filled with fluoride-containing resin sealants [TeethmateF-1 (TF), ClinproTM (CP)], and glass ionomer sealant [Fuji VII (FVII)]. Specimens were then incubated in artificial saliva for 14 days to measure fluoride. Thereafter, demineralization was performed for 10 days, and the anti-demineralization efficacy was assessed by Swept Source Optical Coherence Tomography (SS-OCT), and cross-sectional nanohardness. All data were statistically analyzed by using ANOVA. FVII exhibited the highest fluoride release. SS-OCT and nanohardness findings indicated that anti-demineralization efficacy of TF was the greatest, whereas FVII was not significantly different from that of CP. Resin sealants released a lower amount of fluoride but exhibited anti-demineralization effects on the adjacent unsealed enamel surfaces that were comparable to that of a glass ionomer sealant.


Assuntos
Resinas Compostas/química , Esmalte Dentário/efeitos dos fármacos , Fluoretos/química , Cimentos de Ionômeros de Vidro/química , Selantes de Fossas e Fissuras/química , Desmineralização do Dente/prevenção & controle , Animais , Bovinos , Testes de Dureza , Técnicas In Vitro , Teste de Materiais , Saliva Artificial , Propriedades de Superfície , Tomografia de Coerência Óptica
18.
Dent Mater J ; 37(1): 15-23, 2018 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-28845033

RESUMO

The aim of the study was to evaluate microleakage and the penetration-depths of different fissure-sealant materials applied with/without enameloplasty after cyclic aging. One-hundred-sixty mandibular molars were divided into non-invasive and enameloplasty preparation groups and eight material subgroups, including: flowable composites (microhyrid, nanohybrid, and nanofilled), three resin-based (unfilled, filled, and highly-filled), a giomer-based, and a glass-ionomer-based fissure sealant. Specimens were subjected to two-year cyclic chewing and brushing simulation. After 5% basic-fuchsin dye penetration, specimens were sectioned and scored under stereomicroscope. Kruskal-Wallis statistical data showed that preparation type significantly affected the penetration of all tested materials (p<0.05), but not significantly affected microleakage (p>0.05). Flowable composites showed the best and the glass-ionomer-based sealant showed the worst penetration and microleakage. Slight preparation of fissures is not important in microleakage. However, enameloplasty significantly enhanced the depth of penetration of the sealants. Flowable composites offer promising results at the fissure sealing.


Assuntos
Infiltração Dentária , Selantes de Fossas e Fissuras/química , Corantes , Resinas Compostas/química , Esmalte Dentário/efeitos dos fármacos , Cimentos de Ionômeros de Vidro/química , Humanos , Técnicas In Vitro , Mastigação , Teste de Materiais , Dente Molar , Propriedades de Superfície , Escovação Dentária
19.
Dent Mater J ; 37(2): 266-271, 2018 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-29279545

RESUMO

This study aimed to evaluate the shear bond strength (SBS) and microleakage of a new self-etch adhesive-based fissure sealant (EG) on aprismatic enamel in comparison to conventional fissure sealing with 30 s acid etching (CG). The fissures were sealed according to the manufacturer's instructions. Each group was divided into 3 subgroups: 1-day water storage, 3-month water storage, and 5,000× thermocycling. After measuring SBS using the Ultradent method, failure mode was analyzed. In additional 16 teeth, microleakage was tested using dye penetration method. Pairwise comparisons were analyzed using Mann-Whitney U-Test. Multiple linear regression was performed to assess the factors influencing on SBS. EG had significantly lower mean SBS (4.1 MPa±2.1) than the CG (17.6 MPa±6.4). CG (1.1%) performed significantly better than the EG (12.8%) in microleakage analysis. The tested EG yielded significantly inferior results and its clinical use should be decided after weighing its pros and cons.


Assuntos
Infiltração Dentária , Selantes de Fossas e Fissuras/química , Condicionamento Ácido do Dente , Lâmpadas de Polimerização Dentária , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Teste de Materiais , Dente Serotino , Ácidos Fosfóricos , Resistência ao Cisalhamento , Propriedades de Superfície , Temperatura , Fatores de Tempo , Água/química
20.
Aust Endod J ; 44(3): 267-272, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29064132

RESUMO

This study evaluated the effect of time and concentrations of sodium hypochlorite on the bond strength of a glass fibre post cemented in a root canal with resin cement. A total of 45 single-rooted extracted human teeth were prepared with Protaper® universal files, randomly allocated into nine groups and then subjected to 1% or 4% NaOCl for a period of 1 min or 2 min. Fibre posts were then bonded into the root canal, sectioned and the bond strength tested using a push-out test. A longer irrigation time resulted in a significant reduction (P < 0.05) in bond strength, while a final additional irrigation with distilled water significantly reduced bond strength. The concentration of NaOCl did not significantly affect bond strength. Within the limitations of this study, it was observed that regardless of the concentration of NaOCl used, shorter irrigation times favoured better fibre post bonding.


Assuntos
Força Compressiva , Cimentos Dentários/química , Selantes de Fossas e Fissuras/química , Tratamento do Canal Radicular/métodos , Hipoclorito de Sódio/química , Humanos , Preparo de Canal Radicular/métodos , Estudos de Amostragem , Fatores de Tempo , Extração Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...