Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.425
Filtrar
1.
Radiologia (Engl Ed) ; 66(4): 340-352, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39089794

RESUMO

Transcatheter aortic valve implantation (TAVI) is the alternative to surgical valve replacement, expanding its indications in the latest guidelines. Multimodal CT (MDCT) is essential in patient selection and detection of complications. Vascular complications are frequent, so it is important to analyse the anatomy of the vessels before the procedure. Regarding annular ruptures and ventricular perforations, the volume and distribution of calcium and the ventricular diameter play an important role. Finally, valve migration is a rare complication that can occur both during and after TAVI. Proper planning of the MDCT procedure reduces the risk of complications and gives the interventional cardiologist security both before and during the procedure.


Assuntos
Tomografia Computadorizada Multidetectores , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Cuidados Pré-Operatórios/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem
2.
J Am Heart Assoc ; 13(15): e034298, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39101495

RESUMO

BACKGROUND: Studies have shown inconclusive results on the effectiveness of cerebral protection devices (CPDs) with transcatheter aortic valve replacement. We aimed to analyze the national statistics on stroke and other outcomes with CPD use. METHODS AND RESULTS: The Nationwide Readmissions Database (2017-2020) was queried to obtain data on patients undergoing transcatheter aortic valve replacement. Outcomes were compared between patients with a CPD and patients without a CPD. Of 271 804 patients undergoing transcatheter aortic valve replacement, CPD was used in 7.3% of patients. In a multivariable logistic regression analysis, CPD use was not associated with lower overall stroke rates (1.6% versus 1.9% without CPD; odds ratio, 0.95 [95% CI, 0.84-1.07]; P=0.364), but it was significantly associated with lower major stroke rates (1.2% versus 1.5% without CPD; odds ratio, 0.85 [95% CI, 0.74-0.98]; P=0.02). Patients with a CPD also had a shorter length of stay, higher routine discharges to home/self-care (74.9% versus 70.6%), and lower mortality rates (0.7% versus 1.3%). The 30-day (9.6% versus 11.7%) and 180-day (24.6% versus 28.2%) readmission rates were significantly lower in the CPD cohort. Among patients who developed stroke, patients with a CPD had more frequent routine discharges. Prior valve surgery was associated with the highest risk of overall and major stroke. CONCLUSIONS: CPD use during transcatheter aortic valve replacement was not independently associated with a lower risk of overall stroke but was associated with a lower risk of major stroke in a multivariable model. Data from future randomized trials that may offset any potential confounders in our study are required to help identify patients who would benefit from the use of these devices.


Assuntos
Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Masculino , Feminino , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Idoso de 80 Anos ou mais , Idoso , Fatores de Risco , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estados Unidos/epidemiologia , Dispositivos de Proteção Embólica , Medição de Risco/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Resultado do Tratamento , Readmissão do Paciente/estatística & dados numéricos , Estudos Retrospectivos , Bases de Dados Factuais , Incidência , Fatores de Tempo
4.
BMC Cardiovasc Disord ; 24(1): 422, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39135174

RESUMO

BACKGROUND: Despite impressive improvements in the safety profile of Transcatheter aortic valve replacement (TAVR), the risk for peri-procedural stroke after TAVR has not declined substantially. In an effort to reduce periprocedural stroke, cerebral embolic protection (CEP) devices have been utilized but have yet to demonstrate benefit in all-comers. There is a paucity of data supporting the utilization of CEP in TAVR patients with an anticipated high risk for peri-procedural stroke. METHODS: The Transcatheter Aortic Valve Replacement In-Hospital Stroke (TASK) score is a clinical risk tool for predicting the in-hospital stroke risk of patients undergoing transfemoral TAVR. This score was used to identify high-risk patients and calculate the expected in-hospital stroke risk. This was a single-centre cohort study in all consecutive TAVR patients who had placement of CEP. The observed versus expected ratio for peri-procedural stroke was calculated. To obtain 95% credible intervals, we used 1000 bootstrapped samples of the original cohort sample size without replacement and recalculated the TASK predicted scores. RESULTS: The study included 103 patients. The median age was 83 (IQR 78,89). 63 were male (61.1%) and 45 (43.69%) had a history of previous Stroke or TIA. Two patients had an in-hospital stroke after TAVR (1.94%). The expected risk of in-hospital stroke based on the TASK score was 3.39% (95% CI 3.07-3.73). The observed versus expected ratio was 0.57 (95% CI 0.52-0.64). CONCLUSION: In this single-center study, we found that in patients undergoing TAVR with high stroke risk, CEP reduced the in-hospital stroke risk by 43% when compared with the risk-score predicted rate. CLINICAL TRIAL NUMBER: N/A.


Assuntos
Dispositivos de Proteção Embólica , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Fatores de Risco , Medição de Risco , Idoso de 80 Anos ou mais , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Fatores de Tempo , Embolia Intracraniana/prevenção & controle , Embolia Intracraniana/etiologia , Embolia Intracraniana/epidemiologia , Embolia Intracraniana/diagnóstico , Estudos Retrospectivos , Técnicas de Apoio para a Decisão , Valor Preditivo dos Testes
5.
J Am Coll Cardiol ; 84(8): 712-722, 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39142725

RESUMO

BACKGROUND: Acute brain infarction detected by diffusion-weighted magnetic resonance imaging (DW-MRI) is common after transcatheter aortic valve replacement (TAVR), but its clinical relevance is uncertain. OBJECTIVES: The authors investigated the relationship between DW-MRI total lesion number (TLN), individual lesion volume (ILV), and total lesion volume (TLV) and clinical stroke outcomes after TAVR. METHODS: Patient-level data were pooled from 4 prospective TAVR embolic protection studies, with consistent predischarge DW-MRI acquisition and core laboratory analysis. C-statistic was used to determine the best DW-MRI measure associated with clinical stroke. RESULTS: A total of 495 of 603 patients undergoing TAVR completed the predischarge DW-MRI. At 30 days, the rate of clinical ischemic stroke was 6.9%. Acute ischemic brain injury was seen in 85% of patients with 5.5 ± 7.3 discrete lesions per patient, mean ILV of 78.2 ± 257.1 mm3, and mean TLV of 555 ± 1,039 mm3. The C-statistic was 0.84 for TLV, 0.81 for number of lesions, and 0.82 for maximum ILV in predicting ischemic stroke. On the basis of the TLV cutpoint as defined by receiver operating characteristic (ROC), patients with a TLV >500 mm3 (vs TLV ≤500 mm3) had more ischemic stroke (18.2% vs 2.3%; P < 0.0001), more disabling strokes (8.8% vs 0.9%; P < 0.0001), and less complete stroke recovery (44% vs 62.5%; P = 0.001) at 30 days. CONCLUSIONS: Our study confirms that the number, size, and total volume of acute brain infarction defined by DW-MRI are each associated with clinical ischemic strokes, disabling strokes, and worse stroke recovery in patients undergoing TAVR and may have value as surrogate outcomes in stroke prevention trials. (A Prospective, Randomized Evaluation of the TriGuard™ HDH Embolic Deflection Device During TAVI [DEFLECT III]; NCT02070731) (A Study to Evaluate the Neuro-embolic Consequences of TAVR [NeuroTAVR]; NCT02073864) (The REFLECT Trial: Cerebral Protection to Reduce Cerebral Embolic Lesions After Transcatheter Aortic Valve Implantation [REFLECT I]; NCT02536196) (The REFLECT Trial: Cerebral Protection to Reduce Cerebral Embolic Lesions After Transcatheter Aortic Valve Implantation [REFLECT II]; NCT02536196).


Assuntos
Imagem de Difusão por Ressonância Magnética , Substituição da Valva Aórtica Transcateter , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Idoso de 80 Anos ou mais , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estudos Prospectivos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , AVC Isquêmico/etiologia , AVC Isquêmico/diagnóstico por imagem , Relevância Clínica
6.
JACC Cardiovasc Interv ; 17(15): 1795-1807, 2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39142756

RESUMO

BACKGROUND: The Valve Academic Research Consortium (VARC)-3 definition for neurologic events after transcatheter aortic valve replacement (TAVR) lacks clinical validation. OBJECTIVES: This study sought to determine the incidence, predictors, and clinical impact of neurologic events following TAVR as defined by VARC-3 criteria. METHODS: This was a multicenter study including 2,924 patients with severe aortic stenosis undergoing TAVR. Based on Neurologic Academic Research Consortium (NeuroARC) classification, neurologic events were classified as NeuroARC type 1 (stroke), NeuroARC type 2 (covert central nervous system injury), and NeuroARC type 3 (transient ischemic attack and delirium). Baseline, procedural, and follow-up data were prospectively collected in a dedicated database. RESULTS: After a median follow-up of 13 (7-37) months, neurologic events occurred in 471 patients (16.1%), NeuroARC type 1, 2, and 3 in 37.4%, 4.7%, and 58.0% of cases, respectively, and the majority (58.6%) were periprocedural. Advanced age, chronic kidney disease, atrial fibrillation, major vascular complications, and in-hospital bleeding determined an increased risk of periprocedural events (P < 0.03 for all). Neurologic events occurring during the periprocedural time frame were independently associated with a substantial increase in mortality at 1 year after the intervention (HR: 1.91; 95% CI: 1.23-2.97; P = 0.004). However, although NeuroARC type 1 was associated with an increased mortality risk (IRR: 3.38; 95% CI: 2.30-5.56; P < 0.001 and IRR: 21.7; 95% CI: 9.63-49.1; P < 0.001 for ischemic and hemorrhagic stroke, respectively), the occurrence of NeuroARC type 3 events had no impact on mortality. CONCLUSIONS: Neurologic events after TAVR were associated with poorer short- and long-term survival. This correlation was related to the type of NeuroARC event defined by the VARC-3 criteria. Given the negative impact on clinical outcomes, every attempt should be made to reduce the risk of neurologic complications after TAVR.


Assuntos
Estenose da Valva Aórtica , Ataque Isquêmico Transitório , Índice de Gravidade de Doença , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Fatores de Risco , Feminino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Incidência , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso de 80 Anos ou mais , Fatores de Tempo , Medição de Risco , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/mortalidade , Ataque Isquêmico Transitório/epidemiologia , Resultado do Tratamento , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/epidemiologia , Delírio/epidemiologia , Delírio/etiologia , Delírio/diagnóstico , Delírio/mortalidade , Bases de Dados Factuais , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem
9.
J Am Coll Cardiol ; 84(9): 848-861, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39168571

RESUMO

Transcatheter aortic valve (TAV) thrombosis may manifest as subclinical leaflet thrombosis (SLT) and clinical valve thrombosis. SLT is relatively common (10%-20%) after transcatheter aortic valve replacement, but clinical implications are uncertain. Clinical valve thrombosis is rare (1.2%) and associated with bioprosthetic valve failure, neurologic or thromboembolic events, heart failure, and death. Treatment for TAV thrombosis has been understudied. In principle, anticoagulation may prevent TAV thrombosis. Non-vitamin K oral anticoagulants, as compared to antiplatelet therapy, are associated with reduced incidence of SLT, although at the cost of higher bleeding and all-cause mortality risk. We present an overview of existing literature for management of TAV thrombosis and propose a rational treatment algorithm. Vitamin K antagonists or non-vitamin K oral anticoagulants are the cornerstone of antithrombotic treatment. In therapy-resistant or clinically unstable patients, ultraslow, low-dose infusion of thrombolytics seems effective and safe and may be preferred over redo-transcatheter aortic valve replacement or explant surgery.


Assuntos
Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Trombose/prevenção & controle , Trombose/etiologia , Anticoagulantes/uso terapêutico , Anticoagulantes/administração & dosagem , Fibrinolíticos/uso terapêutico , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos
10.
BMC Cardiovasc Disord ; 24(1): 448, 2024 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-39182065

RESUMO

OBJECTIVE: This study aimed to identify the incidence, risk factors, and outcomes of permanent pacemaker (PPM) implantation after transcatheter aortic valve implantation (TAVI) procedures. METHODS: A retrospective analysis was conducted on 70 patients who underwent TAVI at the Department of Cardiology, Fujian Provincial Hospital, from January 2018 to March 2022. Based on whether a new PPM was implanted after TAVI, all patients were divided into two groups: NEW PPM and NO PPM. Baseline characteristics and clinical data were compared between the two groups. Univariate analysis was used to analyze different variables between the two groups. A binary logistic regression analysis was used to evaluate independent correlates for PPM implantation after TAVI. RESULTS: The mean age of the 70 patients was 73.1 ± 8.8 years. The incidence of PPM implantation was 17.1%. Patients with diabetes and chronic kidney disease were more likely to require PPM (50% vs. 20.7%, p = 0.042, 25% vs. 5.2%, p = 0.042). Our study did not identify any significant differences in the incidence of electrocardiographic conduction disturbances except for the previous right bundle branch block (RBBB) (NO PPM 6.9% vs. NEW PPM 33.3%, p < 0.05). We found that prosthesis size, implantation depth, procedural duration, and length of hospital and intensive care unit (ICU) stays were comparable between the two groups. The leading independent predictors of PPM implantation were previous RBBB (odds ratio 10.129, p = 0.034). CONCLUSION: The previous RBBB was the leading independent predictor of PPM implantation. New PPM was not associated with significantly new-onset left BBB, extended post-procedure hospitalization, ICU stay, or procedural duration.


Assuntos
Estenose da Valva Aórtica , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Idoso , Resultado do Tratamento , Estimulação Cardíaca Artificial/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Idoso de 80 Anos ou mais , Fatores de Tempo , Medição de Risco , China/epidemiologia , Incidência , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/epidemiologia
11.
Cardiovasc Diabetol ; 23(1): 312, 2024 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-39182080

RESUMO

BACKGROUND: The triglyceride glucose (TyG) index, as a reliable marker of insulin resistance, is associated with the incidence and poor prognosis of various cardiovascular diseases. However, the relationship between the TyG index and clinical outcomes in patients with severe aortic stenosis (AS) who underwent transcatheter aortic valve replacement (TAVR) remains unclear. METHODS: This study consecutively enrolled 1569 patients with AS underwent TAVR at West China Hospital of Sichuan University between April 2014 and August 2023. The outcomes of interest included all-cause mortality, cardiovascular mortality, and major adverse cardiovascular events (MACE). Multivariate adjusted Cox regression and restricted cubic splines (RCS) regression analyses were used to assess the associations between the TyG index and the clinical outcomes. The incremental prognostic value of the TyG index was further assessed by the time-dependent Harrell's C-index, integrated discrimination improvement (IDI) and the net reclassification improvement (NRI). RESULTS: During a median follow-up of 1.09 years, there were 146, 70, and 196 patients experienced all-cause death, cardiovascular death, and MACE, respectively. After fully adjusting for confounders, a per-unit increase of TyG index was associated with a 441% (adjusted HR: 5.41, 95% CI: 4.01-7.32), 385% (adjusted HR: 4.85, 95% CI: 3.16-7.43), and 347% (adjusted HR: 4.47, 95% CI: 3.42-5.85) higher risk of all-cause mortality, cardiovascular mortality and MACE, respectively. The RCS regression analyses revealed a linear association between TyG index and endpoints (all P for non-linearity > 0.05) with 8.40 as the optimal binary cutoff point. Furthermore, adding TyG index to the basic risk model provided a significant incremental value in predicting poor prognosis (Time-dependent Harrell's C-index increased for all the endpoints; All-cause mortality, IDI: 0.11, P < 0.001; NRI: 0.32, P < 0.001; Cardiovascular mortality, IDI: 0.043, P < 0.001; NRI: 0.37, P < 0.001; MACE, IDI: 0.092, P < 0.001; NRI: 0.32, P < 0.001). CONCLUSIONS: In patients with severe AS receiving TAVR, there was a positive linear relationship between TyG index and poor prognosis, with 8.4 as the optimal bivariate cutoff value. Our findings suggest TyG index holds potential value for risk stratification and guiding therapeutic decisions in patients after TAVR.


Assuntos
Estenose da Valva Aórtica , Biomarcadores , Glicemia , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Triglicerídeos , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Idoso , Medição de Risco , Fatores de Risco , Idoso de 80 Anos ou mais , Fatores de Tempo , Resultado do Tratamento , China/epidemiologia , Biomarcadores/sangue , Glicemia/metabolismo , Triglicerídeos/sangue , Causas de Morte , Resistência à Insulina
13.
JACC Cardiovasc Interv ; 17(13): 1597-1606, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38986659

RESUMO

BACKGROUND: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs. OBJECTIVES: The aim of our study was to assess the performance of the latest iteration of THVs used off-label in comparison to the purpose-built JVT in inoperable patients with severe AR. METHODS: We performed a multicenter, retrospective registry with 18 participating centers worldwide collecting data on inoperable patients with severe AR of the native valve. A bicuspid aortic valve was the main exclusion criterion. The primary endpoints were technical and device success, 1-year all-cause mortality, and the composite of 1-year mortality and the heart failure rehospitalization rate. RESULTS: Overall, 256 patients were enrolled. THVs used off-label were used in 168 cases (66%), whereas JVT was used in 88 (34%). JVT had higher technical (81% vs 98%; P < 0.001) and device success rates (73% vs 95%; P < 0.001), primarily driven by significantly lower incidences of THV embolization (15% vs 1.1%; P < 0.001), the need for a second valve (11% vs 1.1%; P = 0.004), and moderate residual AR (10% vs 1.1%; P = 0.007). The permanent pacemaker implantation rate was comparable and elevated for both groups (22% vs 24%; P = 0.70). Finally, no significant difference was observed at the 1-year follow-up in terms of mortality (HR: 0.99; P = 0.980) and the composite endpoint (HR: 1.5; P = 0.355). CONCLUSIONS: The JVT platform has a better acute performance than other THVs when used off-label for inoperable patients with severe AR. A longer follow-up is conceivably needed to detect a possible impact on prognosis.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Feminino , Masculino , Estudos Retrospectivos , Idoso , Resultado do Tratamento , Idoso de 80 Anos ou mais , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Readmissão do Paciente , Recuperação de Função Fisiológica , Europa (Continente) , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Hemodinâmica
15.
J Am Coll Cardiol ; 84(3): 317-321, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-38986674

RESUMO

The bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) procedure allows patients with severe aortic stenosis and anatomical challenges from aortic leaflet orientation, positioning of coronary ostia, and height of sinuses of Valsalva to undergo TAVR. We present a case of intraprocedural cardiac arrest secondary to iatrogenic left main coronary artery obstruction following a successful BASILICA procedure.


Assuntos
Estenose da Valva Aórtica , Parada Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Parada Cardíaca/etiologia , Idoso de 80 Anos ou mais , Doença Iatrogênica/prevenção & controle , Masculino , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/prevenção & controle , Bioprótese/efeitos adversos , Feminino , Angiografia Coronária
18.
Expert Rev Cardiovasc Ther ; 22(7): 325-337, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38970466

RESUMO

INTRODUCTION: Over the past two decades, transcatheter aortic valve replacement (TAVR) has expanded its application across all surgical risk levels, including low-risk patients, where, due to longer life expectancy, reducing common pitfalls of TAVR is essential. To address these needs, many technological advancements have been developed. Myval and the new generation Myval Octacor (Meril Life Sciences Pvt. Ltd) are novel balloon-expandable (BE) transcatheter heart valve (THV) systems designed for the treatment of severe aortic stenosis. AREAS COVERED: This review aims to illustrate the design features of these novel THVs and the main evidence from available studies. Furthermore, we provide evidence of these THVs' performance in challenging scenarios such as extra-large aortic annuli, bicuspid aortic valves, and valve-in-valve/valve-in-ring procedures. EXPERT OPINION: Myval and Myval Octacor have demonstrated comparable early safety and clinical efficacy to the leading contemporary THVs, exhibiting remarkably low rates of moderate to severe paravalvular leak (PVL) and permanent pacemaker implantation (PPI). The wide range of sizes offered by the Myval family may minimize the risk of under-/oversizing, potentially explaining the lower rates of the aforementioned phenomena. Moreover, the presence of both internal skirt and external reinforced cuff may also explain the low rate of moderate to severe PVL.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Índice de Gravidade de Doença , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem
19.
Braz J Cardiovasc Surg ; 39(4): e20230088, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39038027

RESUMO

INTRODUCTION: Diabetes mellitus (DM) in patients undergoing cardiac transcatheter or surgical interventions usually is correlated with poor outcomes. Transcatheter aortic valve implantation (TAVI) has been developed as a therapy choice for inoperable, high-, or intermediate-risk surgical patients with severe aortic stenosis (AS). OBJECTIVE: To evaluate the impact of DM and hemoglobin A1c (HbA1c) on outcomes and survival after TAVI. METHODS: Five hundred and fifty-two symptomatic severe AS patients who underwent TAVI, of whom 164 (29.7%) had DM, were included in this retrospective study. Follow-up was performed after 30 days, six months, and annually. RESULTS: The device success and risks of procedural-related complications were similar between patients with and without DM, except for acute kidney injury, which was more frequent in the DM group (2.4% vs. 0%, P=0.021). In-hospital and first-year mortality were similar between the groups (4.9% vs. 3.6%, P=0.490 and 15.0% vs. 11.2%, P=0.282, respectively). There was a statistical difference between HbA1c ≥ 6.5 and HbA1c ≤ 6.49 groups in total mortality (34.4% vs. 15.8%, P<0.001, respectively). The only independent predictors were Society of Thoracic Surgeons score (hazard ratio [HR] 1.28, 95% confidence interval [CI] 1.09-1.51; P=0.003) and HbA1c level ≥ 6.5 (HR 10.78, 95% CI 2.58-21.50; P=0.003) in multivariable logistic regression analysis. CONCLUSION: In this study, we conclude that DM was not correlated with an increased mortality risk or complication rates after TAVI. Also, it was shown that mortality was higher in patients with HbA1c ≥ 6.5, and it was an independent predictor for long-term mortality.


Assuntos
Estenose da Valva Aórtica , Diabetes Mellitus , Hemoglobinas Glicadas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Idoso de 80 Anos ou mais , Idoso , Resultado do Tratamento , Diabetes Mellitus/mortalidade , Hemoglobinas Glicadas/análise , Fatores de Risco , Complicações Pós-Operatórias/mortalidade , Fatores de Tempo , Índice de Gravidade de Doença , Mortalidade Hospitalar
20.
Braz J Cardiovasc Surg ; 39(4): e20230155, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39038084

RESUMO

OBJECTIVE: This study aimed to compare hemodynamic performances and clinical outcomes of patients with small aortic annulus (SAA) who underwent aortic valve replacement by means of sutureless aortic valve replacement (SUAVR) or transcatheter aortic valve implantation (TAVI). METHODS: From 2015 to 2020, 622 consecutive patients with SAA underwent either SUAVR or TAVI. Through a 1:1 propensity score matching analysis, two homogeneous groups of 146 patients were formed. Primary endpoint: all cause-death at 36 months. Secondary endpoints: incidence of moderate to severe patient-prosthesis mismatch (PPM) and incidence of major adverse cardiovascular and cerebrovascular events (MACCEs). RESULTS: All-cause death at three years was higher in the TAVI group (SUAVR 12.2% vs. TAVI 21.0%, P=0.058). Perioperatively, comparable hemodynamic performances were recorded in terms of indexed effective orifice area (SUAVR 1.12 ± 0.23 cm2/m2 vs. TAVI 1.17 ± 0.28 cm2/m2, P=0.265), mean transvalvular gradients (SUAVR 12.9 ± 5.3 mmHg vs. TAVI 12.2 ± 6.2 mmHg, P=0.332), and moderate-to-severe PPM (SUAVR 4.1% vs. TAVI 8.9%, P=0.096). TAVI group showed a higher cumulative incidence of MACCEs at 36 months (SUAVR 18.1% vs. TAVI 32.6%, P<0.001). Pacemaker implantation (PMI) and perivalvular leak ≥ 2 were significantly higher in TAVI group and identified as independent predictors of mortality (PMI: hazard ratio [HR] 3.05, 95% confidence interval [CI] 1.34-6.94, P=0.008; PPM: HR 2.72, 95% CI 1.25-5.94, P=0.012). CONCLUSION: In patients with SAA, SUAVR and TAVI showed comparable hemodynamic performances. Moreover, all-cause death and incidence of MACCEs at follow-up were significantly higher in TAVI group.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Hemodinâmica , Pontuação de Propensão , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Hemodinâmica/fisiologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Resultado do Tratamento , Procedimentos Cirúrgicos sem Sutura/métodos , Próteses Valvulares Cardíacas , Estudos Retrospectivos , Complicações Pós-Operatórias , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...