Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22.114
Filtrar
1.
J Foot Ankle Res ; 17(2): e12014, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38773711

RESUMO

BACKGROUND: Patellofemoral pain (PFP) is characterized by chronic pain in the anterior aspect of the knee during loading activities. Many studies investigating muscle morphology changes for individuals with PFP focus on the proximal joints, however, few studies have investigated muscles of the foot and ankle complex. This study aimed to explore the differences in peroneal muscle size and activation between individuals with PFP and healthy controls using ultrasound imaging in weight-bearing. METHODS: A case-control study in a university lab setting was conducted. Thirty individuals with PFP (age: 20.23 ± 3.30 years, mass: 74.70 ± 27.63 kgs, height: 161.32 ± 11.72 cm) and 30 healthy individuals (age: 20.33 ± 3.37 years, mass: 64.02 ± 11.00 kgs, height: 169.31 ± 9.30 cm) participated. Cross-sectional area (CSA) images of the peroneal muscles were taken in non-weight bearing and weight-bearing positions. The functional activation ratio from lying to single-leg standing (SLS) was calculated. RESULTS: There was a statistically significant (p = 0.041) group (PFP, healthy) by position (non-weight-bearing, weight-bearing) interaction for the peroneal muscle CSA with a Cohen's d effect size of 0.2 in non-weight-bearing position and 0.7 in weight-bearing position. The functional activation ratio for the healthy group was significantly more (p = 0.01) than the PFP group. CONCLUSION: Peroneal muscles were found to be smaller in size in those with PFP compared to the healthy subjects in the weight-bearing SLS position. This study found that those with PFP have lower activation of peroneal muscles in functional position.


Assuntos
Músculo Esquelético , Síndrome da Dor Patelofemoral , Ultrassonografia , Suporte de Carga , Humanos , Suporte de Carga/fisiologia , Estudos de Casos e Controles , Masculino , Feminino , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiopatologia , Músculo Esquelético/patologia , Adulto Jovem , Síndrome da Dor Patelofemoral/fisiopatologia , Síndrome da Dor Patelofemoral/diagnóstico por imagem , Síndrome da Dor Patelofemoral/patologia , Adulto , Adolescente , Pé/fisiopatologia , Pé/diagnóstico por imagem , Pé/patologia , Postura/fisiologia
2.
BMC Musculoskelet Disord ; 25(1): 395, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773398

RESUMO

INTRODUCTION: Anterior cruciate ligament (ACL) ruptures are common injuries that typically affect young, physically active individuals and may require surgical reconstruction. Studies have shown that the long time success of ACL reconstruction depends on the surgical technique and the postoperative rehabilitation strategy. However, there is still no consensus on the content of rehabilitation programs. Hence, additional research is required to elucidate the significance of early weight-bearing in the rehabilitation process following ACL reconstruction. The aim of this article is to examine the impact of weight-bearing on the clinical results of ACL reconstruction. MATERIALS AND METHODS: We retrospectively reviewed patient records who had undergone arthroscopic reconstruction using a semitendinosus-gracilis tendon graft for anterior cruciate ligament rupture between January 2018 and December 2020. The study included the data of 110 patients. The patients were split into two groups: Group 1 underwent early weight-bearing, while Group 2 followed a non-weight-bearing regimen for three weeks. We assessed the patients using the anterior drawer test, Lachman test, range of motion, Lysholm knee scale, Cincinnati scale, Tegner scale, International Knee Documentation Committee (IKDC) form and clinical records. Analytical tests were conducted to compare the results. RESULTS: The complication rates did not show a significant difference between the groups. Group 1 had higher frequencies of positive anterior drawer and Lachman tests. The Lysholm and Cincinnati knee scores of patients in Group 1 were notably lower than those of patients in Group 2. Additionally, the Tegner activity scores and IKDC scores of patients in Group 1 were also meaningfully lower than those of patients in Group 2. In Group 1 patients, there was no notable relationship observed between body mass index (BMI) and the results of the anterior drawer test (ADT) or Lachman test. However, patients with a BMI of 25 or higher in Group 1 showed a decrease in postoperative IKDC scores. In Group 2 patients, no significant relationship was identified between BMI and either the ADT or the Lachman test outcome. CONCLUSION: Based on current literature and current rehabilitation guidelines following ACL reconstruction, the decision to initiate early weight-bearing is based on a limited number of studies with low levels of evidence. In our study, we found that patients who followed a non-weight-bearing regimen for 3 weeks after surgery had better mid-term results than those who were allowed to bear weight early. It appears that further prospective studies on this topic are needed to update rehabilitation guidelines in the next.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Suporte de Carga , Humanos , Reconstrução do Ligamento Cruzado Anterior/reabilitação , Reconstrução do Ligamento Cruzado Anterior/métodos , Reconstrução do Ligamento Cruzado Anterior/efeitos adversos , Estudos Retrospectivos , Feminino , Suporte de Carga/fisiologia , Masculino , Adulto , Lesões do Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/reabilitação , Adulto Jovem , Resultado do Tratamento , Amplitude de Movimento Articular , Artroscopia/efeitos adversos , Artroscopia/métodos , Recuperação de Função Fisiológica , Ligamento Cruzado Anterior/cirurgia , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiopatologia , Adolescente
3.
BMC Musculoskelet Disord ; 25(1): 399, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773516

RESUMO

BACKGROUND: Work-related musculoskeletal disorders are common among healthcare workers (HCWs) but might be prevented by risk assessment and further promotion of occupational safety and health. The aim of this study was to investigate if the risk assessment instrument TilThermometer can be used to identify risk profiles of physical exposure in HCWs working with patient handling and movement (PHM). Further aims were to describe HCWs' perceptions and experiences of using the TilThermometer. METHODS: This feasibility study has a mixed design methodology. In total, 54 HCWs from 17 Swedish care units participated and performed risk assessments with the TilThermometer. Data collected from the risk assessments were used to identify risk profiles of physical exposure. HCWs' experiences of using the TilThermometer were collected from activity logs and analysed qualitatively. Three questionnaires were used to assess perceived acceptability, appropriateness, and feasibility of the risk assessment, and eight study specific questions were used for perceived usefulness. RESULTS: The TilThermometer was used at the care units by assessing each care recipient, and when compiling the data at a group level, a summarized risk profile for the care unit could be provided. Risk for physical exposure was reported as high in two work tasks; no care unit used the high-low adjustable seat when showering care recipients sitting down, and 13% used the recommended assistive devices when putting compression stockings on. However, 99% used high-low adjustable assistive devices when caring and bathing care recipients lying down. TilThermometer was described as easy to use, enabling team reflections and providing an overview of the care units' recipients and workload, but difficulties in categorizing for mobility groups were also reported. The TilThermometer was, on a five-point scale, perceived as acceptable (mean 3.93), appropriate (mean 3.9), and feasible (mean 3.97). These scores are in line with questions evaluating usefulness. CONCLUSION: The risk assessment provided risk profiles with potential to contribute to care units' development of a safe patient handling and movement practice. The findings suggest that the TilThermometer can be used to assess risks for physical exposure in relation to patient handling and movement in care units at hospital and nursing homes.


Assuntos
Estudos de Viabilidade , Pessoal de Saúde , Movimentação e Reposicionamento de Pacientes , Doenças Profissionais , Exposição Ocupacional , Humanos , Medição de Risco , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Exposição Ocupacional/prevenção & controle , Movimentação e Reposicionamento de Pacientes/efeitos adversos , Movimentação e Reposicionamento de Pacientes/instrumentação , Suécia , Doenças Profissionais/prevenção & controle , Doenças Profissionais/etiologia , Doenças Profissionais/diagnóstico , Doenças Profissionais/epidemiologia , Doenças Musculoesqueléticas/prevenção & controle , Doenças Musculoesqueléticas/etiologia , Doenças Musculoesqueléticas/diagnóstico , Inquéritos e Questionários , Suporte de Carga
4.
Med Eng Phys ; 127: 104158, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38692761

RESUMO

BACKGROUND: The intervertebral disc exhibits not only strain rate dependence (viscoelasticity), but also significant asymmetry under tensile and compressive loads, which is of great significance for understanding the mechanism of lumbar disc injury under physiological loads. OBJECTIVE: In this study, the strain rate sensitive and tension-compression asymmetry of the intervertebral disc were analyzed by experiments and constitutive equation. METHOD: The Sheep intervertebral disc samples were divided into three groups, in order to test the strain rate sensitive mechanical behavior, and the internal displacement as well as pressure distribution. RESULTS: The tensile stiffness is one order of magnitude smaller than the compression stiffness, and the logarithm of the elastic modulus is approximately linear with the logarithm of the strain rate, showing obvious tension-compression asymmetry and rate-related characteristics. In addition, the sensitivity to the strain rate is the same under these two loading conditions. The stress-strain curves of unloading and loading usually do not coincide, and form a Mullins effect hysteresis loop. The radial displacement distribution is opposite between the anterior and posterior region, which is consistent with the stress distribution. By introducing the damage factor into ZWT constitutive equation, the rate-dependent viscoelastic and weakening behavior of the intervertebral disc can be well described.


Assuntos
Força Compressiva , Disco Intervertebral , Estresse Mecânico , Animais , Disco Intervertebral/fisiologia , Ovinos , Fenômenos Biomecânicos , Resistência à Tração , Suporte de Carga , Elasticidade
5.
Artigo em Inglês | MEDLINE | ID: mdl-38743847

RESUMO

INTRODUCTION: Pediatric ankle injuries are a common presentation in the emergency department (ED). A quarter of pediatric ankle fractures show no radiographic evidence of a fracture. Physicians often correlate non-weight bearing and tenderness with an occult fracture. We present this study to predict the probability of an occult fracture using radiographic soft-tissue swelling on initial ED radiographs. METHODS: This is a retrospective study at a Level 1 pediatric trauma center from 2021 to 22. Soft-tissue swelling between the lateral malleolus and skin was measured on radiographs, and weight-bearing status was documented. Statistical analysis was conducted using Stata software. DISCUSSION: The study period involved 32 patients with an occult fracture, with 8 (25%) diagnosed with a fracture on follow-up radiographs. The probability of an occult fracture was calculated as a function of the ankle swelling in millimeters (mm) using a computer-generated predictive model. False-negative and false-positive rates were plotted as a function of the degree of ankle swelling. CONCLUSION: Magnitude of ankle soft-tissue swelling as measured on initial ED radiographs is predictive of an occult fracture. Although weight-bearing status was not a sign of occult fracture, it improves the predictive accuracy of soft-tissue swelling.


Assuntos
Fraturas do Tornozelo , Edema , Fraturas Fechadas , Radiografia , Humanos , Fraturas do Tornozelo/diagnóstico por imagem , Estudos Retrospectivos , Masculino , Feminino , Criança , Edema/diagnóstico por imagem , Fraturas Fechadas/diagnóstico por imagem , Adolescente , Serviço Hospitalar de Emergência , Suporte de Carga , Probabilidade , Pré-Escolar , Valor Preditivo dos Testes
6.
Artigo em Inglês | MEDLINE | ID: mdl-38758669

RESUMO

BACKGROUND: Socks are mainly used to give the foot more comfort while wearing shoes. Stitch density of the knitted fabric used in socks can significantly affect the sock properties because it is one of the most important fabric structural factors influencing the mechanical properties. Continuous plantar pressures can cause serious damage, particularly under the metatarsal heads, and it is deduced that using socks redistributes and reduces peak plantar pressures. If peak pressure under the metatarsal heads is predicted, then it will be possible to produce socks with the best mechanical properties to reduce the pressure in these critical areas. METHODS: Plain knitted socks with three different stitch lengths (high, medium, and low) were produced. Static plantar pressure measurements by the Gaitview system were accomplished on ten women and then compared with the barefoot situation. Also, the peak plantar pressure of three types of socks under the metatarsal heads are theoretically predicted using the Hertz contact theory. RESULTS: Experimental results indicate that all socks redistribute the plantar pressure from high to low plantar pressure regions compared with barefoot. In particular, socks with high stitch length have the best performance. By increasing the stitch length, we can significantly reduce the peak plantar pressure of the socks. Correspondingly, the Hertz contact theory resulted in a trend of mean peak pressure reductions in the forefoot region similar to the socks with different stitch densities. CONCLUSIONS: The theoretical results show that by using the Hertz contact theory, static plantar pressure in the forefoot region can be well predicted at a mean error of approximately 9% compared with the other experimental findings.


Assuntos
, Pressão , Humanos , Feminino , Pé/fisiologia , Adulto , Fenômenos Biomecânicos , Vestuário , Sapatos , Suporte de Carga/fisiologia , Adulto Jovem
7.
BMC Musculoskelet Disord ; 25(1): 353, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38724941

RESUMO

BACKGROUND: External fixation is widely used in the treatment of traumatic fractures; however, orthopedic surgeons encounter challenges in deciding the optimal time for fixator removal. The axial load-share ratio (LS) of the fixator is a quantitative index to evaluate the stiffness of callus healing. This paper introduces an innovative method for measuring the LS and assesses the method's feasibility and efficacy. Based on a novel hexapod LS-measurement system, the proposed method is to improve the convenience and precision of measuring LS in vivo, hence facilitating the safe removal of external fixators. METHODS: A novel hexapod system is introduced, including its composition, theoretical model, and method for LS measurement. We conducted a retrospective study on 82 patients with tibial fractures treated by the Taylor Spatial Frame in our hospital from September 2018 to June 2020, of which 35 took LS measurements with our novel method (Group I), and 47 were with the traditional method (Group II). The external fixator was removed when the measurement outcome (LS < 10%) was consistent with the surgeon's diagnosis based on the clinical and radiological assessment (bone union achieved). RESULTS: No significant difference was found in the fracture healing time (mean 25.3 weeks vs. 24.9 weeks, P > 0.05), frame-wearing duration (mean 25.5 weeks vs. 25.8 weeks, P > 0.05), or LS measurement frequency (mean 1.1 times vs. 1.2 times, P > 0.05). The measurement system installation time in Group I was significantly shorter compared to Group II (mean 14.8 min vs. 81.3 min, P < 0.001). The LS value of the first measurement in Group I was lower than that of Group II (mean 5.1% vs. 6.9%, P = 0.011). In Group I, the refracture rate was 0, but in Group II it was 4.3% (2/47, P > 0.05). CONCLUSION: The novel hexapod LS-measurement system and involved method demonstrated enhanced convenience and precision in measuring the LS of the external fixator in vivo. The LS measurement indicates the callus stiffness of fracture healing, and is applicable to evaluate the safety of removing the fixator. Consequently, it is highly recommended for widespread adoption in clinical practice.


Assuntos
Remoção de Dispositivo , Fixadores Externos , Fixação de Fratura , Consolidação da Fratura , Fraturas da Tíbia , Humanos , Feminino , Fraturas da Tíbia/cirurgia , Masculino , Estudos Retrospectivos , Adulto , Pessoa de Meia-Idade , Fixação de Fratura/instrumentação , Fixação de Fratura/métodos , Remoção de Dispositivo/métodos , Suporte de Carga , Adulto Jovem , Idoso , Estudos de Viabilidade , Desenho de Equipamento
8.
PLoS One ; 19(5): e0303342, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38728306

RESUMO

This study protocol aims to investigate how localised cooling influences the skin's microvascular, inflammatory, structural, and perceptual tolerance to sustained mechanical loading at the sacrum, evaluating factors such as morphology, physiology, and perceptual responses. The protocol will be tested on individuals of different age, sex, skin tone and clinical status, using a repeated-measure design with three participants cohorts: i) young healthy (n = 35); ii) older healthy (n = 35); iii) spinal cord injured (SCI, n = 35). Participants will complete three testing sessions during which their sacrum will be mechanically loaded (60 mmHg; 45 min) and unloaded (20 min) with a custom-built thermal probe, causing pressure-induced ischemia and post-occlusive reactive hyperaemia. Testing sessions will differ by the probe's temperature, which will be set to either 38°C (no cooling), 24°C (mild cooling), or 16°C (strong cooling). We will measure skin blood flow (via Laser Doppler Flowmetry; 40 Hz); pro- and anti-inflammatory biomarkers in skin sebum (Sebutape); structural skin properties (Optical Coherence Tomography); and ratings of thermal sensation, comfort, and acceptance (Likert Scales); throughout the loading and unloading phases. Changes in post-occlusive reactive hyperaemia will be considered as the primary outcome and data will be analysed for the independent and interactive effects of stimuli's temperature and of participant group on within- and between-subject mean differences (and 95% Confidence Intervals) in peak hyperaemia, by means of a 2-way mixed model ANOVA (or Friedman). Regression models will also be developed to assess the relationship between absolute cooling temperatures and peak hyperaemia. Secondary outcomes will be within- and between-subject mean changes in biomarkers' expression, skin structural and perceptual responses. This analysis will help identifying physiological and perceptual thresholds for the protective effects of cooling from mechanically induced damage underlying the development of pressure ulcers in individuals varying in age and clinical status.


Assuntos
Sacro , Pele , Humanos , Pele/irrigação sanguínea , Adulto , Masculino , Feminino , Pessoa de Meia-Idade , Adulto Jovem , Inflamação , Traumatismos da Medula Espinal/fisiopatologia , Temperatura Baixa , Idoso , Microvasos/fisiopatologia , Suporte de Carga , Temperatura Cutânea
9.
Medicine (Baltimore) ; 103(19): e38065, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38728521

RESUMO

Knee varus (KV) deformity leads to abnormal forces in the different compartments of the joint cavity and abnormal mechanical loading thus leading to knee osteoarthritis (KOA). This study used computer-aided design to create 3-dimensional simulation models of KOA with varying varus angles to analyze stress distribution within the knee joint cavity using finite element analysis for different varus KOA models and to compare intra-articular loads among these models. Additionally, we developed a cartilage loading model of static KV deformity to correlate with dynamic clinical cases of cartilage injury. Different KV angle models were accurately simulated with computer-aided design, and the KV angles were divided into (0°, 3°, 6°, 9°, 12°, 15°, and 18°) 7 knee models, and then processed with finite element software, and the Von-Mises stress distribution and peak values of the cartilage of the femoral condyles, medial tibial plateau, and lateral plateau were obtained by simulating the human body weight in axial loading while performing the static extension position. Finally, intraoperative endoscopy visualization of cartilage injuries in clinical cases corresponding to KV deformity subgroups was combined to find cartilage loading and injury correlations. With increasing varus angle, there was a significant increase in lower limb mechanical axial inward excursion and peak Von-Mises stress in the medial interstitial compartment. Analysis of patients' clinical data demonstrated a significant correlation between varus deformity angle and cartilage damage in the knee, medial plateau, and patellofemoral intercompartment. Larger varus deformity angles could be associated with higher medial cartilage stress loads and increased cartilage damage in the corresponding peak stress area. When the varus angle exceeds 6°, there is an increased risk of cartilage damage, emphasizing the importance of early surgical correction to prevent further deformity and restore knee function.


Assuntos
Cartilagem Articular , Análise de Elementos Finitos , Articulação do Joelho , Osteoartrite do Joelho , Humanos , Osteoartrite do Joelho/fisiopatologia , Osteoartrite do Joelho/cirurgia , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Articulação do Joelho/fisiopatologia , Masculino , Suporte de Carga/fisiologia , Fenômenos Biomecânicos , Pessoa de Meia-Idade , Estresse Mecânico , Feminino , Simulação por Computador , Idoso
10.
J Orthop Surg (Hong Kong) ; 32(2): 10225536241254200, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38733211

RESUMO

PURPOSE: The primary objective of this study was to determine time to full weight-bearing after the use of a calcium-sulfate-calcium phosphate bone substitute (CaSO4/CaPO4) as a bone void filler in the treatment of primary benign bone tumours following intralesional curettage. The secondary objectives were to determine surgical complications and recurrence rates. METHODS: Retrospective review of patients identified from a surgeon-specific orthopaedic oncology database, who underwent curettage of benign bone tumours and subsequent bone void filling with CaSO4/CaPO4. RESULTS: A total of 39 patients (20 males, 19 females) met inclusion criteria with an average age of 31 years (range: 13 to 62 years), a median follow-up of 3.7 years, and a maximum follow-up of 11 years. The most common tumour diagnosis was giant cell tumour of bone (GCT) (n = 19), and the most common location was the proximal tibia (n = 9). The mean volume of tumour excised was 74.1 cm3 including extraosseous bone expansion due to tumour growth, with a mean of volume of 21.4 mL of CaSO4/CaPO4 used to fill the intraosseous cavitary defects to restore normal bone anatomy. None of the lesions required additional internal fixation. The primary outcome measure, average time to full weight-bearing/full range of motion, was 11 weeks and 6 weeks for upper and lower extremity lesions, respectively. Secondary outcomes included tumour recurrence requiring reoperation in five patients and infection requiring reoperation in two patients. CONCLUSION: This study demonstrates that CaSO4/CaPO4 is a viable option as a bone void filler in the reconstruction of cavitary defects following removal of primary benign bone tumours. CaSO4/CaPO4 provides sufficient bone regeneration early in the post-operative period to allow progression to full weight-bearing within weeks without the need for internal fixation. There were no graft-specific complications noted.


Assuntos
Neoplasias Ósseas , Substitutos Ósseos , Fosfatos de Cálcio , Sulfato de Cálcio , Curetagem , Suporte de Carga , Humanos , Masculino , Feminino , Adulto , Estudos Retrospectivos , Neoplasias Ósseas/cirurgia , Fosfatos de Cálcio/uso terapêutico , Pessoa de Meia-Idade , Adolescente , Substitutos Ósseos/uso terapêutico , Adulto Jovem , Fatores de Tempo
11.
J Biomech ; 168: 112136, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38723427

RESUMO

Alterations in ankle's articular contact mechanics serve as one of the fundamental causes of significant pathology. Nevertheless, computationally intensive algorithms and lack of bilateral weightbearing imaging have rendered it difficult to investigate the normative articular contact stress and side-to-side differences. The aims of our study were two-fold: 1) to determine and quantify the presence of side-to-side contact differences in healthy ankles and 2) to establish normative ranges for articular ankle contact parameters. In this retrospective comparative study, 50 subjects with healthy ankles on bilateral weight-bearing CT were confirmed eligible. Segmentation into 3D bony models was performed semi-automatically, and individualized cartilage layers were modelled based on a previously validated methodology. Contact mechanics were evaluated by using the mean and maximum contact stress of the tibiotalar articulation. Absolute and percentage reference range values were determined for the side-to-side difference. Amongst a cohort of individuals devoid of ankle pathology, mean side-to-side variation in these measurements was < 12 %, while respective differences of > 17 % talar peak stress and > 31 % talar mean stress indicate abnormality. No significant differences were found between laterality in any of the evaluated contact parameters. Understanding these values may promote a more accurate assessment of ankle joint biomechanics when distinguishing acceptable versus pathological contact mechanics in clinical practice.


Assuntos
Articulação do Tornozelo , Tomografia Computadorizada por Raios X , Suporte de Carga , Humanos , Articulação do Tornozelo/fisiologia , Articulação do Tornozelo/diagnóstico por imagem , Masculino , Suporte de Carga/fisiologia , Feminino , Adulto , Tomografia Computadorizada por Raios X/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Fenômenos Biomecânicos , Estresse Mecânico , Idoso
12.
BMC Vet Res ; 20(1): 188, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730373

RESUMO

Femoral fractures are often considered lethal for adult horses because femur osteosynthesis is still a surgical challenge. For equine femur osteosynthesis, primary stability is essential, but the detailed physiological forces occurring in the hindlimb are largely unknown. The objective of this study was to create a numerical testing environment to evaluate equine femur osteosynthesis based on physiological conditions. The study was designed as a finite element analysis (FEA) of the femur using a musculoskeletal model of the loading situation in stance. Relevant forces were determined in the musculoskeletal model via optimization. The treatment of four different fracture types with an intramedullary nail was investigated in FEA with loading conditions derived from the model. The analyzed diaphyseal fracture types were a transverse (TR) fracture, two oblique fractures in different orientations (OB-ML: medial-lateral and OB-AP: anterior-posterior) and a "gap" fracture (GAP) without contact between the fragments. For the native femur, the most relevant areas of increased stress were located distally to the femoral head and proximally to the caudal side of the condyles. For all fracture types, the highest stresses in the implant material were present in the fracture-adjacent screws. Maximum compressive (-348 MPa) and tensile stress (197 MPa) were found for the GAP fracture, but material strength was not exceeded. The mathematical model was able to predict a load distribution in the femur of the standing horse and was used to assess the performance of internal fixation devices via FEA. The analyzed intramedullary nail and screws showed sufficient stability for all fracture types.


Assuntos
Fraturas do Fêmur , Fixação Interna de Fraturas , Membro Posterior , Animais , Cavalos/fisiologia , Fenômenos Biomecânicos , Fraturas do Fêmur/veterinária , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/veterinária , Fixação Interna de Fraturas/métodos , Membro Posterior/cirurgia , Análise de Elementos Finitos , Fêmur/cirurgia , Modelos Biológicos , Suporte de Carga , Fixação Intramedular de Fraturas/veterinária , Fixação Intramedular de Fraturas/instrumentação
13.
Clin Podiatr Med Surg ; 41(3): 519-534, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38789168

RESUMO

Ankle fractures are one of the more common musculoskeletal injuries that are treated by foot and ankle specialists. A thorough understanding of managing these injuries requires the ability to differentiate between stable and unstable fractures. The current literature supports the nonoperative management of stable Weber B ankle fractures, whereas unstable fractures have much better outcomes with surgical intervention. Specifically, we review the fixation strategies for the lateral, medial, and posterior malleolar fractures respectively. Finally, we discuss the current trends in postoperative management of some of the more common fracture patterns, and the safety in early weight-bearing protocols.


Assuntos
Fraturas do Tornozelo , Fixação Interna de Fraturas , Humanos , Fraturas do Tornozelo/terapia , Fraturas do Tornozelo/cirurgia , Fixação Interna de Fraturas/métodos , Masculino , Feminino , Fixação de Fratura/métodos , Suporte de Carga
14.
Medicine (Baltimore) ; 103(21): e38323, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38788003

RESUMO

The calcar femorale, first identified by Merkel in 1874, plays a pivotal role in the weight-bearing capacity of the proximal femur, and its structural integrity is crucial for the efficient distribution of mechanical loads. Originating at the vertical ridge where the pubofemoral ligament anchors, this bony prominence extends laterally behind the neutral axis from the medial to lateral aspects. Its presence is not merely an anatomical curiosity but significantly influences the biomechanics of the hip joint by providing additional strength and support against compressive forces encountered during activities such as walking or jumping. Despite its clear description in orthopedic texts, misconceptions persist about its exact function and importance. This article delves into the nuanced anatomy and biomechanical properties of the calcar femorale, offering a detailed literature-based examination that demonstrates its relevance in clinical practice. The review highlights how the robustness of the calcar femorale contributes to the prevention of femoral neck fractures as well as the stabilization of hip prostheses. Furthermore, the indispensable role of the calcar femorale in surgical outcomes is discussed, especially in the context of fracture repair and joint replacement, thus illustrating its enduring significance in contemporary medical applications.


Assuntos
Fêmur , Humanos , Fenômenos Biomecânicos/fisiologia , Fêmur/anatomia & histologia , Fêmur/fisiologia , Articulação do Quadril/anatomia & histologia , Articulação do Quadril/fisiologia , Suporte de Carga/fisiologia , Artroplastia de Quadril , Fraturas do Colo Femoral , Relevância Clínica
15.
BMC Musculoskelet Disord ; 25(1): 408, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38783272

RESUMO

BACKGROUND: Tenodesis of the long head of the biceps tendon is frequently performed in shoulder surgery, and all-suture anchors have become more popular as fixation methods. However, uncertainty still exists regarding the ultimate load to failure of all-suture anchors and the best insertion angle at a cortical humeral insertion point. PURPOSE: The purpose of this study was to compare the biomechanical characteristics of three types of all-suture anchors frequently used for biceps tenodesis. In addition, the influence of two different insertion angles was observed in a porcine humeri model. METHODS: The ultimate load to failure and failure mode of three types of all-suture anchors (1.6 FiberTak®, 1.9 FiberTak®, 2.6 FiberTak®, Arthrex®) applicable for subpectoral biceps tenodesis were evaluated at 90° and 45° insertion angles in 12 fresh-frozen porcine humeri. The anchors were inserted equally alternated in a randomized manner at three different insertion sites along the bicipital groove, and the suture tapes were knotted around a rod for pullout testing. In total, 36 anchors were evaluated in a universal testing machine (Zwick & Roell). RESULTS: The 2.6 FiberTak® shows higher ultimate loads to failure with a 90° insertion angle (944.0 N ± 169.7 N; 537.0 N ± 308.8 N) compared to the 1.9 FiberTak® (677.8 N ± 57.7 N; 426.3 N ± 167.0 N, p-value: 0.0080) and 1.6 FiberTak® (733.0 N ± 67.6 N; 450.0 N ± 155.8 N, p-value: 0.0018). All anchor types show significantly higher ultimate loads to failure and smaller standard deviations at the 90° insertion angle than at the 45° insertion angle. The major failure mode was anchor pullout. Only the 2.6 FiberTak® anchors showed suture breakage as the major failure mode when placed with a 90° insertion angle. CONCLUSIONS: All three all-suture anchors are suitable fixation methods for subpectoral biceps tenodesis. Regarding our data, we recommend 90° as the optimum insertion angle. CLINICAL RELEVANCE: The influence of anchor size and insertion angle of an all-suture anchor should be known by the surgeon for optimizing ultimate loads to failure and for achieving a secure fixation.


Assuntos
Âncoras de Sutura , Tenodese , Animais , Tenodese/métodos , Tenodese/instrumentação , Suínos , Fenômenos Biomecânicos , Teste de Materiais , Músculo Esquelético/cirurgia , Músculo Esquelético/fisiopatologia , Tendões/cirurgia , Tendões/fisiopatologia , Modelos Animais , Suporte de Carga
16.
Clin Biomech (Bristol, Avon) ; 115: 106257, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38714108

RESUMO

BACKGROUND: The majority of the ankle osteoarthritis cases are posttraumatic and affect younger patients with a longer projected life span. Hence, joint-preserving surgery, such as supramalleolar osteotomy becomes popular among young patients, especially those with asymmetric arthritis due to alignment deformities. However, there is a lack of biomechanical studies on postoperative evaluation of stress at ankle joints. We aimed to construct a verifiable finite element model of the human hindfoot, and to explore the effect of different osteotomy parameters on the treatment of varus ankle arthritis. METHODS: The bones of the hindfoot are reconstructed using normal CT tomography data from healthy volunteers, while the cartilages and ligaments are determined from the literature. The finite element calculation results are compared with the weight-bearing CT (WBCT) data to validate the model. By setting different model parameters, such as the osteotomy height (L) and the osteotomy distraction distance (h), the effects of different surgical parameters on the contact stress of the ankle joint surface are compared. FINDINGS: The alignment and the deformation of hindfoot bones as determined by the finite element analysis aligns closely with the data obtained from WBCT. The maximum contact stress of the ankle joint surface calculated by this model increases with the increase of the varus angle. The maximum contact stresses as a function of the L and h of the ankle joint surface are determined. INTERPRETATION: The relationship between surgical parameters and stress at the ankle joint in our study could further help guiding the planning of the supramalleolar osteotomy according to the varus/valgus alignment of the patients.


Assuntos
Articulação do Tornozelo , Análise de Elementos Finitos , Osteotomia , Humanos , Osteotomia/métodos , Articulação do Tornozelo/cirurgia , Articulação do Tornozelo/fisiopatologia , Articulação do Tornozelo/diagnóstico por imagem , Estresse Mecânico , Simulação por Computador , Modelos Biológicos , Tomografia Computadorizada por Raios X/métodos , Suporte de Carga , Adulto , Masculino , Pé/cirurgia , Pé/fisiopatologia , Pé/diagnóstico por imagem , Osteoartrite/cirurgia , Osteoartrite/fisiopatologia , Osteoartrite/diagnóstico por imagem
17.
J Biomech ; 169: 112133, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38744146

RESUMO

Abnormal loading is thought to play a key role in the disease progression of cartilage, but our understanding of how cartilage compositional measurements respond to acute compressive loading in-vivo is limited. Ten healthy subjects were scanned at two timepoints (7 ± 3 days apart) with a 3 T magnetic resonance imaging (MRI) scanner. Scanning sessions included T1ρ and T2* acquisitions of each knee in two conditions: unloaded (traditional MRI setup) and loaded in compression at 40 % bodyweight as applied by an MRI-compatible loading device. T1ρ and T2* parameters were quantified for contacting cartilage (tibial and femoral) and non-contacting cartilage (posterior femoral condyle) regions. Significant effects of load were found in contacting regions for both T1ρ and T2*. The effect of load (loaded minus unloaded) in femoral contacting regions ranged from 4.1 to 6.9 ms for T1ρ, and 3.5 to 13.7 ms for T2*, whereas tibial contacting regions ranged from -5.6 to -1.7 ms for T1ρ, and -2.1 to 0.7 ms for T2*. Notably, the responses to load in the femoral and tibial cartilage revealed opposite effects. No significant differences were found in response to load between the two visits. This is the first study that analyzed the effects of acute loading on T1ρ and T2* measurements in human femoral and tibial cartilage separately. The results suggest the effect of acute compressive loading on T1ρ and T2* was: 1) opposite in the femoral and tibial cartilage; 2) larger in contacting regions than in non-contacting regions of the femoral cartilage; and 3) not different visit-to-visit.


Assuntos
Cartilagem Articular , Fêmur , Imageamento por Ressonância Magnética , Tíbia , Suporte de Carga , Humanos , Cartilagem Articular/fisiologia , Cartilagem Articular/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Fêmur/fisiologia , Masculino , Adulto , Feminino , Imageamento por Ressonância Magnética/métodos , Tíbia/diagnóstico por imagem , Tíbia/fisiologia , Suporte de Carga/fisiologia , Articulação do Joelho/fisiologia , Articulação do Joelho/diagnóstico por imagem , Força Compressiva/fisiologia
18.
J Morphol ; 285(5): e21695, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38695520

RESUMO

Artiodactyls exhibit a striking diversity of the cervical vertebral column in terms of length and overall mobility. Using finite element analysis, this study explores the morphology at the cervico-thoracic boundary and its performance under loads in artiodactyls with different habitual neck postures and body sizes. The first thoracic vertebra of 36 species was loaded with (i) a compressive load on the vertebral body to model the weight of the head and neck exerted onto the trunk; and (ii) a tensile load at the spinous process to model the pull via the nuchal ligament. Additional focus was laid on the peculiar shape of the first thoracic vertebra in giraffes. We hypothesized that a habitually upright neck posture should be reflected in the greater ability to withstand compressive loads compared to tensile loads, whereas for species with a habitually suspended posture it should be the opposite. In comparison to species with a suspended posture, species with an upright posture exhibited lower stress (except Giraffidae). For compressive loads in larger species, stress surprisingly increased. Tensile loads in larger species resulted in decreased stress only in species with an intermediate or suspensory neck posture. High stress under tensile loads was mainly reflecting the relative length of the spinous process, while high stress under compressive loads was common in more "bell"-shaped vertebral bodies. The data supports a stability-mobility trade-off at the cervico-thoracic transition in giraffes. Performance under load at the cervico-thoracic boundary is indicative of habitual neck posture and is influenced by body size.


Assuntos
Artiodáctilos , Análise de Elementos Finitos , Vértebras Torácicas , Animais , Vértebras Torácicas/fisiologia , Vértebras Torácicas/anatomia & histologia , Artiodáctilos/anatomia & histologia , Artiodáctilos/fisiologia , Postura/fisiologia , Fenômenos Biomecânicos , Estresse Mecânico , Suporte de Carga/fisiologia
19.
J Orthop Surg Res ; 19(1): 280, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38711149

RESUMO

INTRODUCTION: The escalating incidence of anterior cruciate ligament (ACL) injuries, particularly among adolescents, is a pressing concern. The study of ACL biomechanics in this demographic presents challenges due to the scarcity of cadaveric specimens. This research endeavors to validate the adolescent porcine stifle joint as a fitting model for ACL studies. METHODS: We conducted experiments on 30 fresh porcine stifle knee joints. (Breed: Yorkshire, Weight: avg 90 lbs, Age Range: 2-4 months). They were stored at - 22 °C and a subsequent 24-h thaw at room temperature before being prepared for the experiment. These joints were randomly assigned to three groups. The first group served as a control and underwent only the load-to-failure test. The remaining two groups were subjected to 100 cycles, with forces of 300N and 520N, respectively. The load values of 300N and 520N correspond to three and five times the body weight (BW) of our juvenile porcine, respectively. RESULT: The 520N force demonstrated a higher strain than the 300N, indicating a direct correlation between ACL strain and augmented loads. A significant difference in load-to-failure (p = 0.014) was observed between non-cyclically loaded ACLs and those subjected to 100 cycles at 520N. Three of the ten samples in the 520N group failed before completing 100 cycles. The ruptured ACLs from these tests closely resembled adolescent ACL injuries in detachment patterns. ACL stiffness was also measured post-cyclical loading by applying force and pulling the ACL at a rate of 1 mm per sec. Moreover, ACL stiffness measurements decreased from 152.46 N/mm in the control group to 129.42 N/mm after 100 cycles at 300N and a more significant drop to 86.90 N/mm after 100 cycles at 520N. A one-way analysis of variance (ANOVA) and t-test were chosen for statistical analysis. CONCLUSIONS: The porcine stifle joint is an appropriate model for understanding ACL biomechanics in the skeletally immature demographic. The results emphasize the ligament's susceptibility to injury under high-impact loads pertinent to sports activities. The study advocates for further research into different loading scenarios and the protective role of muscle co-activation in ACL injury prevention.


Assuntos
Ligamento Cruzado Anterior , Joelho de Quadrúpedes , Suporte de Carga , Animais , Suínos , Ligamento Cruzado Anterior/fisiologia , Ligamento Cruzado Anterior/fisiopatologia , Joelho de Quadrúpedes/fisiologia , Joelho de Quadrúpedes/fisiopatologia , Suporte de Carga/fisiologia , Fenômenos Biomecânicos , Lesões do Ligamento Cruzado Anterior/fisiopatologia , Estresse Mecânico , Técnicas In Vitro
20.
Prague Med Rep ; 125(2): 172-177, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38761051

RESUMO

The neuropathic compression of the tibial nerve and/or its branches on the medial side of the ankle is called tarsal tunnel syndrome (TTS). Patients with TTS presents pain, paresthesia, hypoesthesia, hyperesthesia, muscle cramps or numbness which affects the sole of the foot, the heel, or both. The clinical diagnosis is challenging because of the fairly non-specific and several symptomatology. We demonstrate a case of TTS caused by medial dislocation of the talar bone on the calcaneus bone impacting the tibial nerve diagnosed only by ultrasound with the patient in the standing position.


Assuntos
Tálus , Síndrome do Túnel do Tarso , Ultrassonografia , Humanos , Síndrome do Túnel do Tarso/etiologia , Síndrome do Túnel do Tarso/diagnóstico , Síndrome do Túnel do Tarso/diagnóstico por imagem , Ultrassonografia/métodos , Tálus/diagnóstico por imagem , Tálus/anormalidades , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/diagnóstico , Luxações Articulares/etiologia , Suporte de Carga , Masculino , Feminino , Pessoa de Meia-Idade , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA