Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.129
Filtrar
1.
Afr Health Sci ; 24(1): 220-227, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38962356

RESUMO

Background: The implementation of surfactant for respiratory syndrome approbates the therapy as a revolutionary method in intensive neonatal therapy and respiratory resuscitation. It is important to investigate the costs of this treatment. Objective: The aim of the study is to analyze the data by the application of the surfactant Curosurf to preterm babies with respiratory complications and describe the treatment costs, healthcare resource utilization and evaluate economic benefits of surfactant use in the treatment of neonates with respiratory distress syndrome (RDS) and hyaline-membrane disease (HDM). Methods: A retrospective survey was performed covering 167 babies based on respiratory complications due to preterm birth and the necessity to apply a surfactant therapy. A documentary method was implemented and for each patient, an individual research protocol was filled out - a questionnaire created specifically for the purposes of the study. Results and discussion: An analysis of the data from the application of CUROSURF was made and the obtained therapeutic results were compared to expenditures for the therapy, short-term therapeutic effect, benefits and consequences of the therapy of preterm newborns with respiratory complications. The application of CUROSURF to babies with RDS resulted in the realization of net savings due to the elimination of the necessity of conducting several diagnostic and therapeutic procedures as well as their duration reduction of hospital stay, thus defining its health-economic benefits. Conclusions: The models of evaluation of cost effectiveness reveal that the medicinal product is expensive but effective from the aspect of short-term therapeutic results.


Assuntos
Análise Custo-Benefício , Recém-Nascido Prematuro , Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Humanos , Recém-Nascido , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico , Síndrome do Desconforto Respiratório do Recém-Nascido/economia , Estudos Retrospectivos , Surfactantes Pulmonares/administração & dosagem , Feminino , Masculino , Doença da Membrana Hialina/tratamento farmacológico , Fosfolipídeos/administração & dosagem , Produtos Biológicos
2.
Trials ; 25(1): 433, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956676

RESUMO

BACKGROUND: Surfactant is a well-established therapy for preterm neonates affected by respiratory distress syndrome (RDS). The goals of different methods of surfactant administration are to reduce the duration of mechanical ventilation and the severity of bronchopulmonary dysplasia (BPD); however, the optimal administration method remains unknown. This study compares the effectiveness of the INtubate-RECruit-SURfactant-Extubate (IN-REC-SUR-E) technique with the less-invasive surfactant administration (LISA) technique, in increasing BPD-free survival of preterm infants. This is an international unblinded multicenter randomized controlled study in which preterm infants will be randomized into two groups to receive IN-REC-SUR-E or LISA surfactant administration. METHODS: In this study, 382 infants born at 24+0-27+6 weeks' gestation, not intubated in the delivery room and failing nasal continuous positive airway pressure (nCPAP) or nasal intermittent positive pressure ventilation (NIPPV) during the first 24 h of life, will be randomized 1:1 to receive IN-REC-SUR-E or LISA surfactant administration. The primary outcome is a composite outcome of death or BPD at 36 weeks' postmenstrual age. The secondary outcomes are BPD at 36 weeks' postmenstrual age; death; pulse oximetry/fraction of inspired oxygen; severe intraventricular hemorrhage; pneumothorax; duration of respiratory support and oxygen therapy; pulmonary hemorrhage; patent ductus arteriosus undergoing treatment; percentage of infants receiving more doses of surfactant; periventricular leukomalacia, severe retinopathy of prematurity, necrotizing enterocolitis, sepsis; total in-hospital stay; systemic postnatal steroids; neurodevelopmental outcomes; and respiratory function testing at 24 months of age. Randomization will be centrally provided using both stratification and permuted blocks with random block sizes and block order. Stratification factors will include center and gestational age (24+0 to 25+6 weeks or 26+0 to 27+6 weeks). Analyses will be conducted in both intention-to-treat and per-protocol populations, utilizing a log-binomial regression model that corrects for stratification factors to estimate the adjusted relative risk (RR). DISCUSSION: This trial is designed to provide robust data on the best method of surfactant administration in spontaneously breathing preterm infants born at 24+0-27+6 weeks' gestation affected by RDS and failing nCPAP or NIPPV during the first 24 h of life, comparing IN-REC-SUR-E to LISA technique, in increasing BPD-free survival at 36 weeks' postmenstrual age of life. TRIAL REGISTRATION: ClinicalTrials.gov NCT05711966. Registered on February 3, 2023.


Assuntos
Recém-Nascido Prematuro , Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Feminino , Humanos , Recém-Nascido , Extubação/efeitos adversos , Displasia Broncopulmonar/terapia , Pressão Positiva Contínua nas Vias Aéreas , Idade Gestacional , Intubação Intratraqueal , Estudos Multicêntricos como Assunto , Surfactantes Pulmonares/administração & dosagem , Ensaios Clínicos Controlados Aleatórios como Assunto , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Síndrome do Desconforto Respiratório do Recém-Nascido/mortalidade , Fatores de Tempo , Resultado do Tratamento
3.
Eur J Pediatr ; 183(8): 3599-3606, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38829378

RESUMO

Surfactant replacement for respiratory distress syndrome (RDS) is currently guided by oxygen (FiO2) requirement in preterm neonates. Lung ultrasound (LUS) has emerged as an important predictive tool; however, there is a paucity of evidence from developing countries. The objective of this study was to determine the diagnostic accuracy of the LUS score in comparison to standard criteria based on FiO2 requirement for prediction of surfactant requirement. In this prospective study, preterm neonates of < 34 weeks' gestation with RDS were included within 2 h of life. Surfactant was administered if the FiO2 requirement exceeded 30%. Baseline characteristics, respiratory parameters, and LUS clips were recorded soon after birth and compared between the surfactant and non-surfactant groups. LUS scoring was later performed by masked assessors which was not used in the management of neonates. Among 82 neonates (mean gestation 30.6 weeks and weight 1375 g) included in the study, 33 (40.2%) received surfactant. The surfactant group had a higher Silverman score, required higher FiO2 and mean airway pressure, and needed invasive ventilation more frequently. The mean (± SD) LUS score was significantly higher in the surfactant (9.4 ± 3.2) compared to the non-surfactant group (5.1 ± 2.1). The diagnostic accuracy of LUS scoring was determined by ROC curve analysis (AUC (95% CI): 0.83 (0.74-0.92), p < 0.01). A cutoff score of ≥ 8 for LUS was considered optimal for the prediction of surfactant requirement (sensitivity and specificity (95% CI) of 70% (51-84) and 80% (66-90), respectively).    Conclusion: Lung ultrasound is a valid diagnostic tool for the prediction of surfactant requirements in resource-limited settings. What is Known: • Lung ultrasound has a good diagnostic accuracy in predicting the need for surfactant administration in preterm neonates in developed countries, but its role in developing countries is unclear. What is New: • Lung ultrasound proved to be a valid diagnostic tool in predicting surfactant replacement therapy in resource-limited settings. • The diagnostic performance of lung ultrasound was better in neonates on non-invasive ventilation, compared to invasive ventilation.


Assuntos
Recém-Nascido Prematuro , Pulmão , Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Ultrassonografia , Humanos , Recém-Nascido , Surfactantes Pulmonares/administração & dosagem , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Síndrome do Desconforto Respiratório do Recém-Nascido/diagnóstico por imagem , Estudos Prospectivos , Masculino , Feminino , Ultrassonografia/métodos , Índia , Pulmão/diagnóstico por imagem , Curva ROC , Valor Preditivo dos Testes , Sensibilidade e Especificidade
4.
J Neonatal Perinatal Med ; 17(2): 233-239, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38759030

RESUMO

INTRODUCTION: Respiratory Distress Syndrome (RDS) is the most common respiratory disorder among premature infants. The use of surfactant has significantly reduced respiratory complications and mortality. There are two conventional methods for administering surfactant: Intubate-Surfactant-Extubate (INSURE) and Less Invasive Surfactant Administration (LISA). This study aims to compare the effects of surfactant administration using these two methods on the treatment outcomes of premature newborns. MATERIALS AND METHODS: In this retrospective cohort study, we included 100 premature newborns with RDS and spontaneous breathing who were admitted to the Neonatal Intensive Care Unit of Besat Hospital in Sanandaj city in 2021. Exclusion criteria comprised congenital anomalies and the needing for intubation for resuscitation at birth. The outcomes of epmericaly trated with two methods were compared: the LISA (50 neonates) and the INSURE (50 neonates). Our interesting outcomes were needing for mechanical ventilation, duration of ventilation, pneumothorax, pulmonary hemorrhage, severe retinopathy, CPAP duration, and bronchopulmonary dysplasia. Finally, we entered the data into STATA-14 statistical software and analyzed it using chi-square and t-tests. RESULTS: In this study, 69% of the neonates were boys. The LISA group exhibited significantly lower rates of need for mechanical ventilation (P = 0.003) and ventilation duration (P < 0.001) compared to the INSURE group. Conversely, there were no significant differences between the two groups (P > 0.05) in terms of pneumothorax, pulmonary hemorrhage, severe retinopathy, CPAP duration, and bronchopulmonary dysplasia rates. CONCLUSION: The results of this study suggest that the LISA method is a safe and non-invasive approach for surfactant administration. Notably, it resulted in a reduced need for mechanical ventilation and decreased ventilation duration compared to the INSURE method.


Assuntos
Recém-Nascido Prematuro , Surfactantes Pulmonares , Respiração Artificial , Síndrome do Desconforto Respiratório do Recém-Nascido , Humanos , Surfactantes Pulmonares/administração & dosagem , Surfactantes Pulmonares/uso terapêutico , Recém-Nascido , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Masculino , Estudos Retrospectivos , Feminino , Respiração Artificial/métodos , Intubação Intratraqueal/métodos , Resultado do Tratamento , Unidades de Terapia Intensiva Neonatal , Pressão Positiva Contínua nas Vias Aéreas/métodos , Extubação/métodos , Displasia Broncopulmonar
5.
Clin Respir J ; 18(5): e13776, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38778673

RESUMO

This systematic review aimed to summarize the available data on the treatment of pulmonary contusions with exogenous surfactants, determine whether this treatment benefits patients with severe pulmonary contusions, and evaluate the optimal type of surfactant, method of administration, and drug concentration. Three databases (MEDline, Scopus, and Web of Science) were searched using the following keywords: pulmonary surfactant, surface-active agents, exogenous surfactant, pulmonary contusion, and lung contusion for articles published between 1945 and February 2023, with no language restrictions. Four reviewers independently rated the studies for inclusion, and the other four reviewers resolved conflicts. Of the 100 articles screened, six articles were included in the review. Owing to the limited number of papers on this topic, various types of studies were included (two clinical studies, two experiments, and two case reports). In all the studies, surfactant administration improved the selected ventilation parameters. The most frequently used type of surfactant was Curosurf® in the concentration of 25 mg/kg of ideal body weight. In most studies, the administration of a surfactant by bronchoscopy into the segmental bronchi was the preferable way of administration. In both clinical studies, patients who received surfactants required shorter ventilation times. The administration of exogenous surfactants improved ventilatory parameters and, thus, reduced the need for less aggressive artificial lung ventilation and ventilation days. The animal-derived surfactant Curosurf® seems to be the most suitable substance; however, the ideal concentration remains unclear. The ideal route of administration involves a bronchoscope in the segmental bronchi.


Assuntos
Contusões , Lesão Pulmonar , Surfactantes Pulmonares , Síndrome do Desconforto Respiratório , Humanos , Surfactantes Pulmonares/administração & dosagem , Surfactantes Pulmonares/uso terapêutico , Contusões/tratamento farmacológico , Lesão Pulmonar/tratamento farmacológico , Lesão Pulmonar/etiologia , Síndrome do Desconforto Respiratório/tratamento farmacológico , Síndrome do Desconforto Respiratório/etiologia , Animais , Respiração Artificial/métodos , Resultado do Tratamento , Broncoscopia/métodos
6.
Respir Med Res ; 85: 101096, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38744231

RESUMO

BACKGROUND: This systematic review and meta-analysis aimed to evaluate the efficacy and safety of inhaled corticosteroids (budesonide, beclomethasone, or fluticasone propionate) in preventing bronchopulmonary dysplasia (BPD) for premature infants. METHOD: Electronic databases, including PubMed, EMBASE, Web of science, Scopus, and Cochrane library, were searched from databases inception to January 2022 for eligible randomized controlled trials. Clinical outcomes such as BPD, mortality, BPD or death, adverse events, and neurodevelopmental outcomes were assessed. RESULTS: Overall, budesonide was significantly associated with a reduction in BPD at 36 weeks' postmenstrual age (RR 0.48; 95 % CI [0.38, 0.62]) and patent ductus arteriosus (PDA) (RR 0.75; 95 % CI [0.63, 0.89]) compared with control treatments. Early longer duration inhalation of budesonide alone was associated with a lower risk of BPD at 36 weeks' postmenstrual age and PDA compared with controls. Early shorter duration intratracheal instillation of budesonide with surfactant as vehicle was associated with a lower risk of BPD at 36 weeks' postmenstrual age and all-cause mortality compared with surfactant. There was no statistically significant difference between budesonide and control groups regarding neurodevelopmental impairment. Beclomethasone and fluticasone propionate did not show any superior or inferior effect on clinical outcomes compared to control treatments. CONCLUSION: These findings suggest that budesonide, especially intratracheal instillation of budesonide using surfactant as a vehicle, is a safe and effective option in preventing BPD for preterm infants. More well-design large-scale trials with long-term follow-ups are necessary to verify the present findings.


Assuntos
Beclometasona , Displasia Broncopulmonar , Budesonida , Fluticasona , Recém-Nascido Prematuro , Humanos , Displasia Broncopulmonar/prevenção & controle , Displasia Broncopulmonar/epidemiologia , Administração por Inalação , Recém-Nascido , Budesonida/administração & dosagem , Budesonida/uso terapêutico , Beclometasona/administração & dosagem , Fluticasona/administração & dosagem , Fluticasona/uso terapêutico , Resultado do Tratamento , Corticosteroides/administração & dosagem , Corticosteroides/efeitos adversos , Corticosteroides/uso terapêutico , Ensaios Clínicos Controlados Aleatórios como Assunto , Permeabilidade do Canal Arterial/tratamento farmacológico , Permeabilidade do Canal Arterial/prevenção & controle , Feminino , Masculino , Surfactantes Pulmonares/administração & dosagem
7.
JAMA Netw Open ; 7(5): e2413446, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38805223

RESUMO

Importance: Surfactant administration may be needed in late preterm through full-term neonates, but the pathophysiology of their respiratory failure can be different from that of early preterm neonates. The lung ultrasonography score (LUS) is accurate to guide surfactant replacement in early preterm neonates, but to our knowledge, it has not yet been studied in the late preterm through full-term neonatal population. Objective: To assess whether LUS is equally accurate to predict surfactant need in late preterm through full-term neonates as in early preterm neonates. Design, Setting, and Participants: This prospective, international, multicenter diagnostic study was performed between December 2022 and November 2023 in tertiary academic neonatal intensive care units in France, Italy, Spain, and the US. Late preterm through full-term neonates (≥34 weeks' gestation) with respiratory failure early after birth were enrolled. Exposure: Point-of-care lung ultrasonography to calculate the neonatal LUS (range, 0-18, with higher scores indicating worse aeration), which was registered in dedicated research databases and unavailable for clinical decision-making. Main Outcomes and Measures: The main outcomes were the area under the curve (AUC) in receiver operating characteristic analysis and derived accuracy variables, considering LUS as a replacement for other tests (ie, highest global accuracy) and as a triage test (ie, highest sensitivity). Sample size was calculated to assess noninferiority of LUS to predict surfactant need in the study population compared with neonates born more prematurely. Correlations of LUS with the ratio of hemoglobin oxygen saturation as measured by pulse oximetry (SpO2) to fraction of inspired oxygen (FiO2) and with the oxygen saturation index (OSI) were assessed. Results: A total of 157 neonates (96 [61.1%] male) were enrolled and underwent lung ultrasonography at a median of 3 hours (IQR, 2-7 hours) of life; 32 (20.4%) needed surfactant administration (pretest probability, 20%). The AUC was 0.87 (95% CI, 0.81-0.92). The highest global accuracy and sensitivity were reached for LUS values higher than 8 or 4 or lower, respectively. Subgroup analysis gave similar diagnostic accuracy in neonates born late preterm (AUC, 0.89; 95% CI, 0.81-0.97; n = 111) and early term and later (AUC, 0.84; 95% CI, 0.73-0.96; n = 46). After adjusting for gestational age, LUS was significantly correlated with SpO2:FiO2 (adjusted ß, -10.4; 95% CI, -14.0 to -6.7; P < .001) and OSI (adjusted ß, 0.2; 95% CI, 0.1-0.3; P < .001). Conclusions and Relevance: In this diagnostic study of late preterm through full-term neonates with respiratory failure early after birth, LUS accuracy to predict surfactant need was not inferior to that observed in earlier preterm neonates. An LUS higher than 8 was associated with highest global accuracy (replacement test), suggesting that it can be used to guide surfactant administration. An LUS value of 4 or lower was associated with the highest sensitivity (triage test), suggesting it is unlikely for this population to need surfactant.


Assuntos
Recém-Nascido Prematuro , Pulmão , Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Ultrassonografia , Humanos , Recém-Nascido , Surfactantes Pulmonares/administração & dosagem , Surfactantes Pulmonares/uso terapêutico , Estudos Prospectivos , Feminino , Ultrassonografia/métodos , Masculino , Pulmão/diagnóstico por imagem , Síndrome do Desconforto Respiratório do Recém-Nascido/diagnóstico por imagem , Idade Gestacional
8.
Zhongguo Dang Dai Er Ke Za Zhi ; 26(4): 337-342, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38660896

RESUMO

OBJECTIVES: To investigate the effects of different angles of pulmonary surfactant (PS) administration on the incidence of bronchopulmonary dysplasia and intracranial hemorrhage in preterm infants. METHODS: A prospective study was conducted on 146 preterm infants (gestational age <32 weeks) admitted to the Department of Neonatology, Provincial Hospital Affiliated to Anhui Medical University from January 2019 to May 2023. The infants were randomly assigned to different angles for injection of pulmonary surfactant groups: 0° group (34 cases), 30° group (36 cases), 45° group (38 cases), and 60° group (38 cases). Clinical indicators and outcomes were compared among the groups. RESULTS: The oxygenation index was lower in the 60° group compared with the other three groups, with shorter invasive ventilation time and oxygen use time, and a lower incidence of bronchopulmonary dysplasia than the other three groups (P<0.05). The incidence of intracranial hemorrhage was lower in the 60° group compared to the 0° group (P<0.05). The cure rate in the 60° group was higher than that in the 0° group and the 30° group (P<0.05). CONCLUSIONS: The clinical efficacy of injection of pulmonary surfactant at a 60° angle is higher than other angles, reducing the incidence of intracranial hemorrhage and bronchopulmonary dysplasia in preterm infants.


Assuntos
Displasia Broncopulmonar , Recém-Nascido Prematuro , Hemorragias Intracranianas , Surfactantes Pulmonares , Humanos , Surfactantes Pulmonares/administração & dosagem , Recém-Nascido , Estudos Prospectivos , Displasia Broncopulmonar/prevenção & controle , Displasia Broncopulmonar/tratamento farmacológico , Displasia Broncopulmonar/etiologia , Masculino , Feminino , Hemorragias Intracranianas/prevenção & controle , Hemorragias Intracranianas/induzido quimicamente
9.
BMC Pediatr ; 24(1): 272, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664650

RESUMO

INTRODUCTION: Neonatal respiratory failure (NRF) is a serious condition that often has high mortality and morbidity, effective interventions can be delivered in the future by identifying the risk factors associated with morbidity and mortality. However, recent advances in respiratory support have improved neonatal intensive care units (NICUs) care in China. We aimed to provide an updated review of the clinical profile and outcomes of NRF in the Jiangsu province. METHODS: Infants treated for NRF in the NICUs of 28 hospitals between March 2019 and March 2022 were retrospectively reviewed. Data collected included baseline perinatal and neonatal parameters, NICU admission- and treatment-related data, and patient outcomes in terms of mortality, major morbidity, and survival without major morbidities. RESULTS: A total of 5548 infants with NRF were included in the study. The most common primary respiratory disorder was respiratory distress syndrome (78.5%). NRF was managed with non-invasive and invasive respiratory support in 59.8% and 14.5% of patients, respectively. The application rate of surfactant therapy was 38.5%, while that of neonatal extracorporeal membrane oxygenation therapy was 0.2%. Mortality and major morbidity rates of 8.5% and 23.2% were observed, respectively. Congenital anomalies, hypoxic-ischemic encephalopathy, invasive respiratory support only and inhaled nitric oxide therapy were found to be significantly associated with the risk of death. Among surviving infants born at < 32 weeks of gestation or with a birth weight < 1500 g, caffeine therapy and repeat mechanical ventilation were demonstrated to significantly associate with increased major morbidity risk. CONCLUSION: Our study demonstrates the current clinical landscape of infants with NRF treated in the NICU, and, by proxy, highlights the ongoing advancements in the field of perinatal and neonatal intensive care in China.


Assuntos
Unidades de Terapia Intensiva Neonatal , Síndrome do Desconforto Respiratório do Recém-Nascido , Humanos , Recém-Nascido , China/epidemiologia , Estudos Retrospectivos , Feminino , Masculino , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Insuficiência Respiratória/terapia , Surfactantes Pulmonares/uso terapêutico , Surfactantes Pulmonares/administração & dosagem , Oxigenação por Membrana Extracorpórea , Respiração Artificial/estatística & dados numéricos , Resultado do Tratamento
10.
Int J Gynaecol Obstet ; 166(2): 767-774, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38340014

RESUMO

OBJECTIVE: To evaluate if antenatal steroid use was associated with a lower rate of respiratory complications in neonates born late preterm to patients with pregestational diabetes mellitus (PGDM). METHODS: This was a retrospective cohort study of live, singleton, non-anomalous, late preterm births complicated by PGDM using data from the Centers for Disease Control and National Vital Statistics System from 2017 to 2021. The primary (assisted ventilation use >6 h) and secondary neonatal outcomes (immediate assisted ventilation, Apgar score, neonatal intensive care unit [NICU] admission, and surfactant use) were compared between births that received steroids and those that did not. Multivariable analyses were performed to adjust for differences in demographic and clinical characteristics. RESULTS: There were 24 323 late preterm births with PGDM, of which 4613 received antenatal steroids and 19 710 did not receive steroids. After adjusting for the differences among the two groups, the need for assisted neonatal ventilation for more than 6 h (adjusted odds ratio [aOR] 1.69, 95% confidence interval [CI] 1.53-1.86), immediate assisted neonatal ventilation (aOR 1.67, 95% CI 1.55-1.80), NICU admission (aOR 1.95, 95% CI 1.81-2.10), and surfactant use (aOR 1.68, 95% CI 1.40-2.02) were higher in the births that received steroids compared with those that did not. These findings did not differ when examining outcomes at each gestational week of delivery between 34 weeks 0 days and 36 weeks 6 days. CONCLUSIONS: Antenatal steroid use in late preterm births complicated with PGDM was associated with worse immediate respiratory neonatal outcomes. Our findings support current recommendations against the use of steroids in the late preterm period in pregnancies with PGDM.


Assuntos
Gravidez em Diabéticas , Nascimento Prematuro , Humanos , Feminino , Gravidez , Estudos Retrospectivos , Recém-Nascido , Adulto , Nascimento Prematuro/epidemiologia , Gravidez em Diabéticas/tratamento farmacológico , Síndrome do Desconforto Respiratório do Recém-Nascido/epidemiologia , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Recém-Nascido Prematuro , Índice de Apgar , Idade Gestacional , Masculino , Respiração Artificial/estatística & dados numéricos , Esteroides/administração & dosagem , Esteroides/uso terapêutico , Cuidado Pré-Natal/métodos , Surfactantes Pulmonares/administração & dosagem , Surfactantes Pulmonares/uso terapêutico , Resultado da Gravidez
11.
Pediatr Res ; 95(6): 1603-1610, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38097721

RESUMO

BACKGROUND: Respiratory care protocol including less invasive ssurfactant administration (LISA) in ≤29 weeks' gestational age (GA) infants introduced in October 2018. METHODS: Retrospective study of infants admitted on continuous positive airway pressure (CPAP) October 2018 to December 2021. Maternal and neonatal variables were compared between infants managed on CPAP with and without LISA. Infants who received LISA and subsequently required mechanical ventilation (MV) within 72 h of life (HOL) [LISA failure (LF)] were compared with those who required no MV [LISA success (LS)]. RESULTS: 249 infants were admitted on CPAP, 5 were intubated prior to LISA, 143 required LISA and 101 remained on CPAP without surfactant. Of those receiving LISA, 108 were LS and 35 were LF. Compared to LS, LF infants were of lower GA and birth weight, required higher fractional inspired oxygen (FiO2), and CPAP level at birth, admission, one HOL, and an hour after LISA. Moreover, LF infants had higher mortality and morbidity. Together GA ≤ 25 weeks' and FiO2 ≥ 0.3 an hour after LISA best predicted LF. CONCLUSIONS: Over 80% of infants admitted on CPAP avoided MV within 72 HOL. Early predictors of LF provide targets for future interventions to decrease need for MV in preterm infants. IMPACT: Less invasive surfactant administration (LISA) decreases the need for mechanical ventilation (MV) and improves outcomes. However, some infants require MV within 72 h of life (HOL) despite LISA (LISA failure). Over 80% of ≤29 weeks' gestational age (GA) infants can be successfully managed on CPAP with or without surfactant in the first 72 HOL. A combination of factors including ≤25 weeks' GA and fraction of inspired oxygen ≥0.3 an hour after LISA predict LISA failure. Evaluation of a noninvasive respiratory support strategy including LISA provides targets for intervention to decrease need for MV in preterm infants.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Idade Gestacional , Recém-Nascido Prematuro , Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Humanos , Recém-Nascido , Estudos Retrospectivos , Surfactantes Pulmonares/administração & dosagem , Surfactantes Pulmonares/uso terapêutico , Feminino , Masculino , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico , Respiração Artificial , Resultado do Tratamento
12.
JAMA ; 330(11): 1054-1063, 2023 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-37695601

RESUMO

Importance: The long-term effects of surfactant administration via a thin catheter (minimally invasive surfactant therapy [MIST]) in preterm infants with respiratory distress syndrome remain to be definitively clarified. Objective: To examine the effect of MIST on death or neurodevelopmental disability (NDD) at 2 years' corrected age. Design, Setting, and Participants: Follow-up study of a randomized clinical trial with blinding of clinicians and outcome assessors conducted in 33 tertiary-level neonatal intensive care units in 11 countries. The trial included 486 infants with a gestational age of 25 to 28 weeks supported with continuous positive airway pressure (CPAP). Collection of follow-up data at 2 years' corrected age was completed on December 9, 2022. Interventions: Infants assigned to MIST (n = 242) received exogenous surfactant (200 mg/kg poractant alfa) via a thin catheter; those assigned to the control group (n = 244) received sham treatment. Main Outcomes and Measures: The key secondary outcome of death or moderate to severe NDD was assessed at 2 years' corrected age. Other secondary outcomes included components of this composite outcome, as well as hospitalizations for respiratory illness and parent-reported wheezing or breathing difficulty in the first 2 years. Results: Among the 486 infants randomized, 453 had follow-up data available (median gestation, 27.3 weeks; 228 females [50.3%]); data on the key secondary outcome were available in 434 infants. Death or NDD occurred in 78 infants (36.3%) in the MIST group and 79 (36.1%) in the control group (risk difference, 0% [95% CI, -7.6% to 7.7%]; relative risk [RR], 1.0 [95% CI, 0.81-1.24]); components of this outcome did not differ significantly between groups. Secondary respiratory outcomes favored the MIST group. Hospitalization with respiratory illness occurred in 49 infants (25.1%) in the MIST group vs 78 (38.2%) in the control group (RR, 0.66 [95% CI, 0.54-0.81]) and parent-reported wheezing or breathing difficulty in 73 (40.6%) vs 104 (53.6%), respectively (RR, 0.76 [95% CI, 0.63-0.90]). Conclusions and Relevance: In this follow-up study of a randomized clinical trial of preterm infants with respiratory distress syndrome supported with CPAP, MIST compared with sham treatment did not reduce the incidence of death or NDD by 2 years of age. However, infants who received MIST had lower rates of adverse respiratory outcomes during their first 2 years of life. Trial Registration: anzctr.org.au Identifier: ACTRN12611000916943.


Assuntos
Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Feminino , Humanos , Lactente , Recém-Nascido , Dispneia , Seguimentos , Recém-Nascido Prematuro , Lipoproteínas , Surfactantes Pulmonares/administração & dosagem , Surfactantes Pulmonares/uso terapêutico , Síndrome do Desconforto Respiratório/complicações , Síndrome do Desconforto Respiratório/tratamento farmacológico , Síndrome do Desconforto Respiratório/terapia , Síndrome do Desconforto Respiratório do Recém-Nascido/complicações , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Sons Respiratórios , Tensoativos/administração & dosagem , Tensoativos/uso terapêutico , Cateterismo , Procedimentos Cirúrgicos Minimamente Invasivos , Pressão Positiva Contínua nas Vias Aéreas , Masculino , Pré-Escolar
13.
Acta Paediatr ; 111(11): 2108-2114, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35896864

RESUMO

AIM: We explored whether subnormal forced expiratory volume within 1 s (FEV1 ) at 5-9 years of age was lower in children born preterm who received less invasive surfactant administration (LISA) rather than surfactant via an endotracheal tube. METHODS: The multi-centre, randomised Nonintubated Surfactant Application trial enrolled 211 preterm infants born at 23-26 weeks of gestation from 13 level III neonatal intensive care units from April 2009 to March 2012. They received surfactant via LISA (n = 107) or after conventional endotracheal intubation (n = 104). The follow-up assessments were carried out by a single team blinded to the group assignments. The main outcome was FEV1 < 80% of predicted values. RESULTS: Spirometry was successful in 102/121 children. The other children died or were lost to follow-up. Median FEV1 was 93% (interquartile range 80%-113%) of predicted values in the LISA group and 86% (interquartile range 77-102%) in the control group (p = 0.685). Rates of FEV1 < 80% were 11/57 (19%) and 15/45 (33%), respectively, which was an absolute risk reduction of 14% (95% confidence interval -3.1% to 31.2%, p = 0.235). There were no differences in other outcome measures. CONCLUSION: The proportion of children aged 5-9 years with subnormal FEV1 was not significantly different between the groups.


Assuntos
Surfactantes Pulmonares , Criança , Pré-Escolar , Humanos , Recém-Nascido Prematuro , Intubação Intratraqueal , Surfactantes Pulmonares/administração & dosagem , Espirometria
14.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue ; 34(1): 80-84, 2022 Jan.
Artigo em Chinês | MEDLINE | ID: mdl-35307066

RESUMO

OBJECTIVE: To investigate the efficacy and safety of nasal continuous positive airway pressure (NCPAP) combined with inhalation of pulmonary surfactant (PS) using vibrating mesh nebulizers in the treatment of neonatal respiratory distress syndrome (RDS). METHODS: A prospective study was performed on premature infants with RDS admitted to the First Affiliated Hospital of Bengbu Medical College between December 2020 and June 2021. They were randomly assigned into vibrating mesh atomization technology group and intubation-surfactant-extubation (INSURE) technology group. The two groups were treated with NCPAP combined with PS. PS in the vibrating mesh atomization technology group was inhaled into the lungs by the new vibrating mesh atomization technology, while PS in the INSURE group was injected into the lungs by endotracheal tube. The pH value, arterial partial pressure of carbon dioxide (PaCO2), oxygenation index (PaO2/FiO2), mechanical ventilation via endotracheal tube (MVET) demand rate, duration of respiratory support, secondary use of PS, complications, and hospital mortality were compared between the two groups. The occurrences of adverse events in the two groups were recorded. RESULTS: A total of 42 preterm infants were finally enrolled, including 20 cases in the vibrating mesh atomization technology group and 22 cases in the INSURE technology group. There were no significant differences in blood gas analysis and PaO2/FiO2 before PS administration between the two groups. One hour after PS administration, blood gas analysis and PaO2/FiO2 were significantly improved in both groups. Compared with the INSURE technology group, the improvement of PaO2/FiO2 was more obvious in the vibrating mesh atomization technology group [mmHg (1 mmHg≈0.133 kPa): 198±34 vs. 173±39, P < 0.05], but no significant difference in pH value or PaCO2 was found between the two groups. The duration of respiratory support in the vibrating mesh atomization technology group was significantly shorter than that in the INSURE technology group (hours: 96±13 vs. 120±18, P < 0.01), but there was no statistical difference in MVET demand rate [5.0% (1/20) vs. 13.6% (3/22), P > 0.05]. The incidence of periventricular-intraventricular hemorrhage (PVH-IVH) in the vibrating mesh atomization technology group was less than that in the INSURE technology group [0% (0/20) vs. 18.2% (4/22)], but no statistical difference was found (P > 0.05). No significant differences in the secondary use rate of PS and incidence of bronchopulmonary dysplasia (BPD) or other complications were found between the vibrating mesh atomization technology group and the INSURE technology group [5.0% (1/20) vs. 9.1% (2/22), 5.0% (1/20) vs. 4.5% (1/22), both P > 0.05]. There were no deaths or serious adverse events such as pneumothorax, pulmonary hemorrhage, periventricular leukomalacia (PVL), retinopathy of prematurity (ROP), and necrotizing enterocolitis (NEC) in both groups. CONCLUSIONS: Compared with the INSURE technique, NCPAP combined with vibrating mesh atomization technology was also effective and safe in the treatment of RDS, which could significantly improve PaO2/FiO2 and shorten the duration of respiratory support. Thus, it was worthy of clinical popularization and application.


Assuntos
Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Administração por Inalação , Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Nebulizadores e Vaporizadores , Estudos Prospectivos , Surfactantes Pulmonares/administração & dosagem , Surfactantes Pulmonares/efeitos adversos , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico
15.
Turk J Med Sci ; 52(6): 1779-1784, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36945972

RESUMO

BACKGROUND: We aimed to discuss term infants who are given surfactant due to respiratory disorder according to the underlying etiology, the dose of surfactant administration, and the need for repeated surfactant administration. METHODS: In this retrospective study infants hospitalized in the 4th level neonatal intensive care unit during January 2019 and December 2021 and administered surfactant due to respiratory distress were included. Term infants given surfactant due to respiratory failure were included in the study through the data recording system. The number of surfactant doses, indications for administration, mortality, duration of hospitalization, intubation time, and inotrope use were recorded in the infants included in the study. RESULTS: : During the two-year period, 1250 infants were hospitalized in our neonatal intensive care unit. Of those, 56 infants received surfactant replacement therapy for severe respiratory failure. There were 30 infants with pneumonia, 4 infants with meconium aspiration syndrome (MAS), and 22 infants with transient tachypnea of the newborn (TTN). It was seen that single-dose administration was higher in patients with TTN (p = 0.01), while multiple-dose surfactant administration was more common in patients with MAS, resulting in a statistical difference (p = 0.02). Mortality was lower, especially in cases given early surfactant administration and this situation was statistically significant (p < 0.001). Duration of intubation was 5.05 ± 4.7 days in early surfactant administration group and 8.0 ± 6.1 days in late surfactant administration group. This difference was statistically significant (p = 0.04). While early surfactant application was statistically higher in the TTN group (p = 0.007), late surfactant application was statistically higher in the pneumonia group (p = 0.001). DISCUSSION: Despite the difference on administration time and repeat dose interval due to etiology, surfactant treatment is improving the respiratory distress of term infants.


Assuntos
Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Insuficiência Respiratória , Tensoativos , Humanos , Masculino , Feminino , Gravidez , Recém-Nascido , Lactente , Tensoativos/administração & dosagem , Tensoativos/uso terapêutico , Surfactantes Pulmonares/administração & dosagem , Surfactantes Pulmonares/uso terapêutico , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico , Taquipneia Transitória do Recém-Nascido , Insuficiência Respiratória/tratamento farmacológico , Síndrome de Aspiração de Mecônio , Resultado do Tratamento
16.
Arch Dis Child Fetal Neonatal Ed ; 107(2): 156-160, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34413092

RESUMO

OBJECTIVE: The aim of this study was to determine the experience with, and the feasibility of, point-of-view video recordings using eye-tracking glasses for training and reviewing neonatal interventions during the COVID-19 pandemic. DESIGN: Observational prospective single-centre study. SETTING: Neonatal intensive care unit at the Leiden University Medical Center. PARTICIPANTS: All local neonatal healthcare providers. INTERVENTION: There were two groups of participants: proceduralists, who wore eye-tracking glasses during procedures, and observers who later watched the procedures as part of a video-based reflection. MAIN OUTCOME MEASURES: The primary outcome was the feasibility of, and the proceduralists and observers' experience with, the point-of-view eye-tracking videos as an additional tool for bedside teaching and video-based reflection. RESULTS: We conducted 12 point-of-view recordings on 10 different patients (median gestational age of 30.9±3.5 weeks and weight of 1764 g) undergoing neonatal intubation (n=5), minimally invasive surfactant therapy (n=5) and umbilical line insertion (n=2). We conducted nine video-based observations with a total of 88 observers. The use of point-of-view recordings was perceived as feasible. Observers further reported the point-of-view recordings to be an educational benefit for them and a potentially instructional tool during COVID-19. CONCLUSION: We proved the practicability of eye-tracking glasses for point-of-view recordings of neonatal procedures and videos for observation, educational sessions and logistics considerations, especially with the COVID-19 pandemic distancing measures reducing bedside teaching opportunities.


Assuntos
COVID-19/epidemiologia , Tecnologia de Rastreamento Ocular , Unidades de Terapia Intensiva Neonatal , Internato e Residência/métodos , Gravação em Vídeo , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Intubação/métodos , Pandemias , Estudos Prospectivos , Surfactantes Pulmonares/administração & dosagem , SARS-CoV-2
17.
Arch Dis Child Fetal Neonatal Ed ; 107(1): 51-55, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34112722

RESUMO

OBJECTIVE: To evaluate the safety of an aerosolised surfactant, SF-RI 1, administered via nasal continuous positive airway pressure (nCPAP) and a prototype breath synchronisation device (AeroFact), to preterm infants with respiratory distress syndrome (RDS). DESIGN: Multicentre, open-label, dose-escalation study with historical controls. SETTING: Newborn intensive care units at Mater Mothers' Hospital, Brisbane, and Royal Hospital for Women, Sydney, Australia. PATIENTS: Infants 26 weeks through 30 weeks gestation who required nCPAP 6-8 cmH2O and fraction of inspired oxygen (FiO2) <0.30 at <2 hours of age. INTERVENTIONS: In part 1, infants received a single dose of 216 mg/kg of aerosolised surfactant. In part 2, infants could receive up to four doses of aerosolised surfactant. Three historical control infants were matched for each enrolled infant. MAIN OUTCOME MEASURES: Treatment failure was defined as Respiratory Severity Score (FiO2×cmH2O nCPAP) >2.4, nCPAP >8 cmH2O, arterial carbon dioxide >65 mm Hg, pH <7.20 or three severe apnoeas within 6 hours during the first 72 hours of life. Other outcomes included tolerance of the AeroFact treatment and complications of prematurity. RESULTS: 10 infants were enrolled in part 1 and 21 in part 2 and were compared with 93 historical controls. No safety issues were identified. In part 2, 6 of 21 (29%) AeroFact-treated infants compared with 30 of 63 (48%) control infants met failure criteria. Kaplan-Meier analysis of patients in part 2 showed a trend towards decreased rate of study failure in the AeroFact-treated infants compared with historical controls (p=0.10). CONCLUSION: The AeroFact system can safely deliver aerosolised surfactant to preterm infants with RDS who are on nCPAP. TRIAL REGISTRATION NUMBER: ACTRN12617001458325.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Sistemas de Liberação de Medicamentos , Fosfolipídeos/administração & dosagem , Surfactantes Pulmonares/administração & dosagem , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico , Aerossóis , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Fosfolipídeos/efeitos adversos , Fosfolipídeos/uso terapêutico , Projetos Piloto , Surfactantes Pulmonares/efeitos adversos , Surfactantes Pulmonares/uso terapêutico , Falha de Tratamento
18.
Arch Dis Child Fetal Neonatal Ed ; 107(2): 222-224, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34083353

RESUMO

INTRODUCTION: Less-invasive surfactant administration (LISA) under continuous positive airway pressure is increasingly used for the treatment of neonatal respiratory distress. Different procedures are described, but data on the optimal catheter insertion depth are sparse. OBJECTIVE: To generate data for recommending an optimal catheter insertion depth in LISA. METHODS: We examined 112 anterior-posterior chest X-rays from intubated infants and determined the carina's vertebral projection, whenever possible. After that, distances between the middle of cervical vertebra 4 (C4) and thoracic vertebra 2 and the middle of C4 to thoracic vertebra 3, respectively, were measured. Results were plotted against infant's weight. RESULTS: A weight-based chart and recommendations for the optimal intratracheal catheter position in infants with a body weight between 350 and 4000 g were created. CONCLUSIONS: Generated data offer standardisation and may thus help to find a balance between risk of surfactant reflux and unilateral surfactant administration.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Recém-Nascido Prematuro , Intubação Intratraqueal/métodos , Surfactantes Pulmonares/administração & dosagem , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Vias de Administração de Medicamentos , Humanos , Lactente , Recém-Nascido , Respiração Artificial/métodos
20.
JAMA ; 326(24): 2478-2487, 2021 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-34902013

RESUMO

Importance: The benefits of surfactant administration via a thin catheter (minimally invasive surfactant therapy [MIST]) in preterm infants with respiratory distress syndrome are uncertain. Objective: To examine the effect of selective application of MIST at a low fraction of inspired oxygen threshold on survival without bronchopulmonary dysplasia (BPD). Design, Setting, and Participants: Randomized clinical trial including 485 preterm infants with a gestational age of 25 to 28 weeks who were supported with continuous positive airway pressure (CPAP) and required a fraction of inspired oxygen of 0.30 or greater within 6 hours of birth. The trial was conducted at 33 tertiary-level neonatal intensive care units around the world, with blinding of the clinicians and outcome assessors. Enrollment took place between December 16, 2011, and March 26, 2020; follow-up was completed on December 2, 2020. Interventions: Infants were randomized to the MIST group (n = 241) and received exogenous surfactant (200 mg/kg of poractant alfa) via a thin catheter or to the control group (n = 244) and received a sham (control) treatment; CPAP was continued thereafter in both groups unless specified intubation criteria were met. Main Outcomes and Measures: The primary outcome was the composite of death or physiological BPD assessed at 36 weeks' postmenstrual age. The components of the primary outcome (death prior to 36 weeks' postmenstrual age and BPD at 36 weeks' postmenstrual age) also were considered separately. Results: Among the 485 infants randomized (median gestational age, 27.3 weeks; 241 [49.7%] female), all completed follow-up. Death or BPD occurred in 105 infants (43.6%) in the MIST group and 121 (49.6%) in the control group (risk difference [RD], -6.3% [95% CI, -14.2% to 1.6%]; relative risk [RR], 0.87 [95% CI, 0.74 to 1.03]; P = .10). Incidence of death before 36 weeks' postmenstrual age did not differ significantly between groups (24 [10.0%] in MIST vs 19 [7.8%] in control; RD, 2.1% [95% CI, -3.6% to 7.8%]; RR, 1.27 [95% CI, 0.63 to 2.57]; P = .51), but incidence of BPD in survivors to 36 weeks' postmenstrual age was lower in the MIST group (81/217 [37.3%] vs 102/225 [45.3%] in the control group; RD, -7.8% [95% CI, -14.9% to -0.7%]; RR, 0.83 [95% CI, 0.70 to 0.98]; P = .03). Serious adverse events occurred in 10.3% of infants in the MIST group and 11.1% in the control group. Conclusions and Relevance: Among preterm infants with respiratory distress syndrome supported with CPAP, minimally invasive surfactant therapy compared with sham (control) treatment did not significantly reduce the incidence of the composite outcome of death or bronchopulmonary dysplasia at 36 weeks' postmenstrual age. However, given the statistical uncertainty reflected in the 95% CI, a clinically important effect cannot be excluded. Trial Registration: anzctr.org.au Identifier: ACTRN12611000916943.


Assuntos
Produtos Biológicos/administração & dosagem , Displasia Broncopulmonar/prevenção & controle , Pressão Positiva Contínua nas Vias Aéreas , Recém-Nascido Prematuro , Fosfolipídeos/administração & dosagem , Surfactantes Pulmonares/administração & dosagem , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico , Feminino , Humanos , Recém-Nascido , Doenças do Prematuro/mortalidade , Masculino , Síndrome do Desconforto Respiratório do Recém-Nascido/mortalidade , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Método Simples-Cego
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...