Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.973
Filtrar
1.
Int J Esthet Dent ; 19(3): 212-225, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39092817

RESUMO

Digital technologies are gradually gaining ground in dentistry. In particular, taking impressions with intraoral scanners is becoming routine; however, even this must often be preceded by the use of retraction cords. This article presents an innovative technique to record digital impressions of natural tooth abutments using interim restorations relined with impression material instead of retraction cords. In the laboratory, using computer-aided design, the technician can segment the internal surface of the interim restoration and use it to replace the abutment of the intraoral scan, thus obtaining an accurate coping that yields more detailed information about the supragingival and intrasulcular surface of the preparation.


Assuntos
Desenho Assistido por Computador , Dente Suporte , Técnica de Moldagem Odontológica , Humanos , Materiais para Moldagem Odontológica/química
2.
Shanghai Kou Qiang Yi Xue ; 33(3): 306-311, 2024 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-39104349

RESUMO

PURPOSE: To compare the mucosal morphological difference in distal-extension area of mandibular dentition defect taken by intra-oral digital scanning and selective pressure impression techniques. METHODS: Seventeen patients with Kennedy Class I and Class II dentition defect in lower jaw were included, including twenty-two distal-extensions. Intraoral digital scanning and functional impression technique were taken in each patients, respectively. Laboratory cast scanner was used to scan the plaster casts made from the selective pressure impression to obtain the three-dimensional data. All the data were stored in STL format. The 3D data collecting from intra-oral digital scanning and selective pressure impression from the same patient were compared by Geomagic Control 2014 software. Root mean square of 2.5mm diameter area was calculated in 5,10,15 mm from terminal tooth. Pearson's correlation test was used to analyze the correlation of the distance and morphological difference with SPSS 20.0 software package. RESULTS: Mean mucosal morphological difference of jaw distal-extension edentulous area taken by intra-oral digital scanning and selective pressure impression techniques was (0.37±0.12) mm. There was positive correlation between distance from terminal tooth and mucosal morphological difference(P<0.05). Morphological differences in 5, 10, 15 mm from terminal tooth were (0.14±0.11) mm, (0.22±0.13) mm and (0.39±0.16) mm, respectively. CONCLUSIONS: In this study, there was positive correlation between the length of distal-extension edentulous area and mucosal morphological difference, while the kind of ridge defect and mucosal thickness may also affect the morphological difference quantity.


Assuntos
Técnica de Moldagem Odontológica , Mandíbula , Humanos , Mandíbula/anatomia & histologia , Imageamento Tridimensional/métodos , Modelos Dentários , Mucosa Bucal/anatomia & histologia
3.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(4): 481-485, 2024 Aug 01.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-39049636

RESUMO

OBJECTIVES: This study aimed to evaluate the application of digital impression and resin model technology in removable partial dentures (RPD) for Kennedy classⅠandⅡdentition defects. METHODS: Patients with Kennedy classⅠorⅡdental defect were selected and grouped in accordance with the following denture production processes: digital impression/resin model/cast cobalt-chromium alloy framework group (group A), digital impression/resin model/laser printed titanium framework group (group B), alginate impression/plaster model/cast cobalt-chromium alloy framework group (group C), and alginate impression/plaster model/laser printed titanium framework group (group D), with 40 cases in each group. The final RPD was examined in place in the mouth, and the evaluation indicators included the retention force of clamp ring, the tightness of connector and base, and the accuracy of occlusion. The evaluation scores of each index were used for analysis on the Kruskal-Wallis rank-sum test. RESULTS: No statistically significant difference in the score of each index was found among the four groups in RPD. CONCLUSIONS: The cast cobalt-chromium alloy and laser-printed titanium framework RPD using digital impression and resin model can meet the clinical restoration requirements of patients with Kennedy classⅠandⅡdentition defects.


Assuntos
Técnica de Moldagem Odontológica , Planejamento de Dentadura , Prótese Parcial Removível , Humanos , Ligas de Cromo , Titânio , Lasers , Desenho Assistido por Computador
4.
BMC Oral Health ; 24(1): 764, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38970004

RESUMO

BACKGROUND: This clinical study aims to evaluate the accuracy of the conventional implant impression techniques compared to the digital impression ones in bilateral distal extension cases. METHODS: A total of 32 implants were placed in eight patients missing all mandibular posterior teeth except the first premolars. Each patient received a total of four implants, with two implants placed on each side, in order to provide support for three units of screw-retained zirconia restorations. Following osteointegration, the same patient underwent two implant-level impression techniques: Conventional open-tray impressions CII (splinted pick-up) and digital implant impressions DII with TRIOS 3 Shape intraoral scanner. The accuracy of impressions was evaluated utilizing a three-dimensional superimposition analysis of standard tessellation language (STL) files. Subsequently, the scan bodies were segmented using Gom inspect software to measure three-dimensional deviations in a color-coding map. Data were statistically analyzed using the Kruskal Wallis test and then a post-hoc test to determine the significance level (P < 0.05). RESULTS: The study revealed that higher angular and positional deviations were shown toward distal scan bodies compared to mesial ones for both impression techniques. However, this difference was not statistically significant (P > 0.05). CONCLUSION: Splinted open-tray conventional impression and intraoral scanning implant impression techniques have demonstrated comparable accuracy. TRIAL REGISTRATION: Clinical Trials.gov Registration ID NCT05912725. Registered 22/06/ 2023- Retrospectively registered, https://register. CLINICALTRIALS: gov .


Assuntos
Técnica de Moldagem Odontológica , Humanos , Feminino , Masculino , Implantes Dentários , Desenho Assistido por Computador , Adulto , Pessoa de Meia-Idade , Imageamento Tridimensional/métodos
5.
J Dent ; 148: 105244, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39068858

RESUMO

OBJECTIVES: To evaluate the fabrication trueness of additively manufactured maxillary definitive casts with various tooth preparations fabricated with different 3-dimensional (3D) printers and print orientations. METHODS: A maxillary typodont with tooth preparations for a posterior 3-unit fixed partial denture, lateral incisor crown, central incisor and canine veneers, first premolar and second molar inlays, and a first molar crown was digitized with an industrial scanner. This scan file was used to fabricate definitive casts with a digital light processing (DLP) or stereolithography (SLA) 3D printer in different orientations (0-degree, 30-degree, 45-degree, and 90-degree) (n = 7). All casts were digitized with the same scanner, and the deviations within each preparation site were evaluated. Generalized linear model analysis was used for statistical analysis (α = 0.05). RESULTS: The interaction between the 3D printer and the print orientation affected measured deviations within all preparations (P ≤ 0.001) except for the lateral incisor crown and canine veneer (P ≥ 0.094), which were affected only by the main factors (P < 0.001). DLP-90 mostly led to the highest and DLP-0 mostly resulted in the lowest deviations within posterior tooth preparations (P ≤ 0.014). DLP-30 led to the lowest deviations within the first premolar inlay and DLP-45 led to the lowest deviations within the central incisor veneer preparation (P ≤ 0.045). CONCLUSIONS: Posterior preparations of tested casts had the highest trueness with DLP-0 or DLP-30, while central incisor veneer preparations had the highest trueness with DLP-45. DLP-90 led to the lowest trueness for most of the tooth preparations. CLINICAL SIGNIFICANCE: Definitive casts with tooth preparations fabricated with the tested DLP 3D printer and the print orientation adjusted on tooth preparation may enable well-fitting restorations. However, 90-degree print orientation should be avoided with this 3D printer, as it led to the lowest fabrication trueness.


Assuntos
Desenho Assistido por Computador , Facetas Dentárias , Modelos Dentários , Impressão Tridimensional , Humanos , Dente Molar , Incisivo/anatomia & histologia , Prótese Parcial Fixa , Restaurações Intracoronárias , Preparo Prostodôntico do Dente/métodos , Estereolitografia , Planejamento de Prótese Dentária , Dente Canino/anatomia & histologia , Dente Pré-Molar , Maxila/anatomia & histologia , Coroa do Dente/anatomia & histologia , Técnica de Moldagem Odontológica/instrumentação , Técnica de Fundição Odontológica , Processamento de Imagem Assistida por Computador/métodos , Coroas
6.
Clin Exp Dent Res ; 10(4): e924, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39016106

RESUMO

OBJECTIVES: The aim of this in vitro study was to investigate whether and to what extent different scenarios of rotational freedom in different IAC designs affect the vertical dimension of a three-part fixed partial denture (FPD). At the same time, the experimental setup should simulate all clinical and laboratory steps of the implementation of such an FPD as accurately as possible. MATERIAL AND METHODS: Twenty identical pairs of jaw models were fabricated from aluminum, each lower-jaw model holding two implants with conical or flat IACs. Three impressions of each model were taken to fabricate stone casts and three-unit FPDs. Three assembly scenarios were compared for the vertical position stability they offered for these FPDs, differing by how the sequential implant components (impression posts > laboratory analogs > abutments 1 > abutments 2) were aligned with the positional index of the IAC. In this way, a total of 60 stone casts and FPDs were fabricated and statistically analyzed for changes in vertical dimension (p < 0.05). RESULTS: Regardless of whether a conical/flat IAC was used (p > 0.05), significantly greater mean changes in vertical dimension were consistently (all comparisons p < 0.0001) found in a "worst-case scenario" of component alignment alternating between the left- and right-limit stop of the positional index (0.286/0.350 mm) than in a "random scenario" of 10 dentists and 10 technicians with varying levels of experience freely selecting the alignment (0.003/0.014 mm) or in a "best-case scenario" of all components being aligned with the right-limit stop (-0.019/0.005 mm). CONCLUSIONS: The likelihood of integrating a superstructure correctly in terms of vertical dimension appears to vary considerably more with assembly strategies than with IAC designs. Specifically, our findings warrant a recommendation that all implant components should be aligned with the right-limit stop of the positioning index.


Assuntos
Prótese Dentária Fixada por Implante , Prótese Parcial Fixa , Humanos , Prótese Dentária Fixada por Implante/métodos , Rotação , Modelos Dentários , Dente Suporte , Dimensão Vertical , Projeto do Implante Dentário-Pivô/métodos , Implantes Dentários , Técnicas In Vitro , Técnica de Moldagem Odontológica/instrumentação
7.
Gen Dent ; 72(4): 50-53, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38905605

RESUMO

Patients are always looking for conservative, esthetic, and long-lasting dental restorations, and the technique used directly influences the longevity of the treatment. The location of the restoration in the mouth and the extent of the decay influence the treatment choice. The larger the dimensions of the cavity preparation, the greater the difficulties in restoring the tooth using direct techniques. The semidirect technique, when indicated, can achieve satisfactory results. It is a relatively easy procedure, consisting of tooth preparation to receive an indirect restoration, fabrication of an alginate impression, fabrication of the composite resin restoration on a flexible cast, cementation, removal of excess cement, and occlusal adjustment. The aim of this case report is to present a viable alternative to direct and indirect restorations for posterior teeth with extensive decay. The article describes the extraoral semidirect technique for fabricating a composite resin restoration, highlighting its indications and discussing advantages and disadvantages.


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Humanos , Resinas Compostas/uso terapêutico , Restauração Dentária Permanente/métodos , Seguimentos , Feminino , Cárie Dentária/terapia , Masculino , Preparo da Cavidade Dentária/métodos , Cimentação/métodos , Materiais Dentários/uso terapêutico , Materiais Dentários/química , Dente Molar , Técnica de Moldagem Odontológica
8.
J Long Term Eff Med Implants ; 34(4): 95-101, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38842237

RESUMO

The long-term success of dental implants depends not only upon implant osseointegration, but also on the surrounding soft tissue health and profile. An ideal emergence profile contributes to the aesthetics of an implant restoration. It maintains long-term implant health by preventing potential food accumulation and forming a barrier against bacterial ingress. This article describes a method for obtaining an impression of implants that will capture the custom guided peri-implant soft tissue contours accurately, thus contributing to a final restoration with favorable aesthetics. We also describe a technique for reducing excess cement in a cement retained implant crown, thereby contributing to the health of the peri-implant tissues.


Assuntos
Cimentação , Humanos , Dente Suporte , Coroas , Projeto do Implante Dentário-Pivô , Prótese Dentária Fixada por Implante , Feminino , Implantes Dentários , Estética Dentária , Restauração Dentária Temporária , Implantação Dentária Endóssea/métodos , Pessoa de Meia-Idade , Técnica de Moldagem Odontológica
9.
J Dent ; 148: 105135, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38885735

RESUMO

OBJECTIVES: To evaluate the accumulative effect of 3D printer, implant analog systems, and implant angulation on the accuracy of analog position in implant casts. METHODS: A reference cast, presenting a case of a three-unit implant-supported prosthesis, was scanned with a coordinate measurement machine, producing the first reference data set (CMM, n = 1). The second reference data set (n = 10) was prepared using an intraoral scanner (IOS) (Trios4). Test quadrant casts were produced using three DLP type 3D printers, Max (MAX UV385), Pro (PRO 4K65 UV), and Nex (NextDent 5100), and three implant analog systems, El (Elos), Nt (Nt-trading), and St (Straumann) (n = 90). Stone casts were also produced via analog impressions (Stone, n = 10). After digitization, the accuracy of 3D distance, local angulation (angle between implants) and global angulation (angle between the implant center axis and an axis perpendicular to the global plane) was evaluated by comparing the reference (CMM, IOS), test (3D print), and control (Stone) groups using metrology software. Data were statistically analyzed using three-way ANOVA and Tukey`s tests (α = 0.05). RESULTS: IOS was truer in 3D implant distance and more precise in capturing local angulation than Stone (p ≤ 0.05). Other measurements were similar between both groups (p > 0.05). The amount of error introduced in the workflow by IOS and 3D printing was mostly similar (p > 0.05). 3D printed casts had similar or even higher accuracy than Stone group (p > 0.05). In most cases, higher trueness was achieved when using PRO 4K65 UV 3D printer and Elos implant analog system (p ≤ 0.05). CONCLUSION: 3D printer, implant analog system, and implant angulation have a significant effect on the accuracy of analog position in implant casts. Limited-span implant-supported cases could be reproduced digitally with similar accuracy as conventional methods. CLINICAL SIGNIFICANCE: A fully digital workflow with a carefully selected 3D printer and implant analog system can increase the accuracy of digitally produced implant casts with comparable accuracy to conventional workflow.


Assuntos
Desenho Assistido por Computador , Implantes Dentários , Prótese Dentária Fixada por Implante , Modelos Dentários , Impressão Tridimensional , Humanos , Técnica de Moldagem Odontológica/instrumentação , Planejamento de Prótese Dentária , Imageamento Tridimensional/métodos , Técnica de Fundição Odontológica
10.
J Dent ; 148: 105152, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38909643

RESUMO

OBJECTIVES: To review the developments in intraoral scanner (IOS) technologies applied in implant prosthodontics, emphasizing their influence on the accuracy of digital impressions, occlusal registrations, and the fit of implant-supported restorations. DATA: A collection of published articles related to implant prosthodontics, the accuracy of digital impressions, occlusal registration, and the fit of implant-supported fixed restorations. SOURCES: Three search engines were selected: Medline/PubMed, EBSCO, and Cochrane. A manual search was also conducted. STUDY SELECTION: A literature search screened relevant databases and journals for studies on IOS applications in digital implant prosthodontic workflows from Dec 2018 to Dec 2023. Inclusion criteria encompassed randomized control trials, clinical trials, case series, and in vitro research focused on the use of IOS in digital implant prosthodontics. CONCLUSIONS: The increased utilization of digital dental technologies has led to significant integration of digital implant prosthodontic workflows into clinicians' clinical practice. Several variables affect the accuracy of digital impressions generated by IOS. Generally, the prevailing opinion in academic papers is that digital workflows are suitable for addressing short-span implant-supported restorations. However, when it comes to long-span defects, the accuracy of digital workflows is still a matter of debate. Digital bite registration is an integral part of the workflow. It depends mainly on the defect size and location, scan strategy, anatomical tooth variations, overbite and other factors. The overall fit of digitally prefabricated implant restorations comprises of proximal, occlusal contacts and how accurately the restoration connects with implants. Research methodologies need standardization for further validation. CLINICAL SIGNIFICANCE: In clinical practice, it is essential to have a thorough and up-to-date comprehension of various factors that can affect the accuracy of digital impressions and the fit of the final prosthesis in implant prosthodontics.


Assuntos
Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Prótese Dentária Fixada por Implante , Humanos , Implantes Dentários , Prostodontia , Planejamento de Prótese Dentária/métodos , Imageamento Tridimensional
11.
Clin Exp Dent Res ; 10(3): e899, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38752461

RESUMO

BACKGROUND: The aim of this study was to determine if different types of core substrates have any effect on the trueness and precision of digital intraoral impressions. MATERIAL AND METHODS: A customized typodont with four similar cores of natural dentine, composite, metal (Ni-Cr), and zirconia in the position of premolars was fabricated. The study model was scanned five times with two types of intraoral scanners (Carestream 3600 and 3Shape Trios 3), and a reference standard scan was obtained using a laboratory scanner (3shape D1000). A metrology software (Geomagic X) was used to align the data of experimental scans and the reference scan to determine deviation values (trueness). Precision values were calculated with random superimposition in each intraoral scanner group. The Kruskal-Wallis test was used to compare differences between different substrates, and the Mann-Whitney test was used to compare the average values between the two scanners. RESULTS: Trios 3 was found to be significantly truer and more precise than Carestream 3600 (p value = .005, <0.001). There were no significant differences in the trueness of different substrates when they were scanned by Trios 3, while different materials showed significantly different trueness values in the Carestream 3600 group (p value = .003). Dentin showed the best trueness, and zirconia performed worse than other substrates. Regarding the precision of the scanners, neither of the scanners was affected by the type of scanning substrate. CONCLUSION: For Carestream 3600, substrate type did impact the trueness of intraoral scans, with dentin and zirconia showing the highest and lowest accuracy, respectively, while Trios 3 was similarly accurate across all substrates. Trios 3 had both higher trueness and precision than Carestream 3600.


Assuntos
Técnica de Moldagem Odontológica , Humanos , Técnica de Moldagem Odontológica/instrumentação , Zircônio/química , Desenho Assistido por Computador , Modelos Dentários , Reprodutibilidade dos Testes , Software
12.
Eur J Prosthodont Restor Dent ; 32(2): 183-193, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38691584

RESUMO

INTRODUCTION: The purpose of this in vitro study was to evaluate the dimensional accuracy, trueness, and precision of vinyl siloxane ether (VSXE) and polyvinylsiloxane (PVS) impression materials using different impression techniques. MATERIAL AND METHODS: A three-dimensional (3D) printed mandibular model with implants and metal rods served as the reference model. Impressions were taken in custom trays, resulting in four groups: PVS-closed-tray, VSXE-closed-tray, PVS-open-tray, and VSXE-open-tray. The reference model and impressions were scanned and analyzed using 3D analysis software to assess the trueness and precision within each group. RESULTS: There was significant difference in trueness between the groups, with PVS closed tray showing a higher deviation than VSXE-closed-tray and PVS-open-tray. VSXE-open-tray had the lowest deviation, which was statistically significant. In terms of precision, PVS-closed-tray showed the highest deviation, while no significant differences were found among the other groups. CONCLUSIONS: VSXE impression material with an open tray technique consistently demonstrated the highest levels of accuracy and precision. Conversely, PVS impression material with a closed tray technique yielded less favorable results. CLINICAL RELEVANCE: Better understanding of trueness and precision of new impression materials with new impression techniques will increase their clinical effectiveness.


Assuntos
Materiais para Moldagem Odontológica , Técnica de Moldagem Odontológica , Revestimento de Dentadura , Mandíbula , Polivinil , Siloxanas , Materiais para Moldagem Odontológica/química , Siloxanas/química , Humanos , Prótese Dentária Fixada por Implante , Impressão Tridimensional , Técnicas In Vitro , Modelos Dentários
13.
J Evid Based Dent Pract ; 24(2): 101987, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38821664

RESUMO

ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: Clinical outcomes of digital scans versus conventional impressions for implant-supported fixed complete arch prostheses: A systematic review and meta-analysis. I. A., Spin-Neto, R., Sesma, N., & da Silva, E. V. F. The Journal of Prosthetic Dentistry (2023). SOURCE OF FUNDING: Not reported. TYPE OF STUDY/DESIGN: Systematic review with network meta-analysis of data.


Assuntos
Perda do Osso Alveolar , Técnica de Moldagem Odontológica , Prótese Dentária Fixada por Implante , Humanos , Perda do Osso Alveolar/diagnóstico por imagem , Desenho Assistido por Computador , Revisões Sistemáticas como Assunto , Metanálise como Assunto
14.
Eur Arch Paediatr Dent ; 25(3): 433-441, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38698225

RESUMO

PURPOSE: To determine the variation of OXIS contact areas in primary molars using digital impressions generated from an intraoral scanner (IOS). METHODS: A cross-sectional study was carried out on 214 caries-free posterior quadrants of 80 children (38 males and 42 females) aged 3-6 years. Calibration of taking digital impressions with the IOS procedure was performed initially through scanning of ten quadrants of children to provide a learning environment to the examiner. The digital impressions were then exported, and the type of interproximal contact areas present between the distal surface of the primary first molar and the mesial surface of the primary second molar were identified according to the OXIS classification. The prevalence of the types of OXIS contact areas was expressed in the form of numbers and percentages. The chi-square test was applied to investigate the variability among the arches and to understand the association of OXIS contact areas across age, gender, and arches. RESULTS: The most common contact area type observed was I-type (59.8%), followed by S-type (15.4%), X-type (12.6%), and O-type (12.2%). The I-type contact area was most frequently seen in both males (51.6%) and females (65.5%), while the S-type contact area in males (14.7%) and X-type contact area in females (8.4% each) were the least frequent with no statistical significance between genders (p > 0.05). All three age groups studied showed the highest prevalence of the I-type contact area, which increased with an increase in age (p < 0.05). The inter-arch comparison showed a significant result in terms of the X-type contact area on the right side, and O-type, X-type, and I-type contact areas on the left side, while no statistical difference was seen in the intra-arch comparison for all contact types. CONCLUSION: I-type contact areas were the most prevalent across the arches, age groups and genders.


Assuntos
Dente Molar , Dente Decíduo , Humanos , Masculino , Feminino , Dente Molar/diagnóstico por imagem , Criança , Estudos Transversais , Pré-Escolar , Técnica de Moldagem Odontológica , Fatores Sexuais
15.
J Dent ; 146: 105050, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38735468

RESUMO

OBJECTIVES: The objective of this study was to use in vitro models to examine the bite registration accuracy of four different intraoral scanners (IOS) for edentulous maxillary and mandibular arches. The objective was to assess the trueness and precision of the IOS and determine if there were significant differences between them. METHODS: An Asiga Max UV 3D printer was used to print maxillary and mandibular edentulous models based on the shape of Frasaco models (artificial dental arch models). Four dental implants were placed symmetrically in both models using Straumann BLT RC implants. Digital impressions were taken with Primescan, Trios 3, Trios 4, and Medit i500 intraoral scanners (n = 10 for each IOS). Digital bite registrations were made, and scanning data was exported in STL format. The accuracy of the interarch distance (the distance between the metrological spheres attached to the mandibular and maxillary models) was estimated for each IOS. RESULTS: The results showed significant differences in trueness and precision between different IOS (p <.05), except Medit i500 and Trios 3 (p >.05). Primescan provided the most accurate results, followed by Medit i500, Trios 3, and Trios 4, respectively. CONCLUSIONS: within the limitations of this study, the IOS type affects the accuracy of interocclusal bite registration in in vitro design. Only Primescan achieved clinically acceptable accuracy for the interocclusal recording of edentulous arches. CLINICAL RELEVANCE: The comparison of the accuracy of bite registration between different intraoral scanners will help increase the efficiency of the clinical application of digitalized interarch registration.


Assuntos
Arco Dental , Técnica de Moldagem Odontológica , Arcada Edêntula , Mandíbula , Maxila , Modelos Dentários , Humanos , Mandíbula/diagnóstico por imagem , Arco Dental/diagnóstico por imagem , Arco Dental/anatomia & histologia , Maxila/diagnóstico por imagem , Técnica de Moldagem Odontológica/instrumentação , Arcada Edêntula/diagnóstico por imagem , Registro da Relação Maxilomandibular/instrumentação , Desenho Assistido por Computador , Impressão Tridimensional , Implantes Dentários , Imageamento Tridimensional/métodos , Processamento de Imagem Assistida por Computador/métodos
16.
J Dent ; 146: 105037, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38703808

RESUMO

OBJECTIVES: To evaluate the positional accuracy of implant analogs in biobased model resin by comparing them to that of implant analogs in model resin casts and conventional analogs in dental stone casts. METHODS: Polyvinylsiloxane impressions of a partially edentulous mandibular model with a single implant were made and poured in type IV dental stone. The same model was also digitized with an intraoral scanner and additively manufactured implant casts were fabricated in biobased model resin (FotoDent biobased model) and model resin (FotoDent model 2 beige-opaque) (n = 8). All casts and the model were digitized with a laboratory scanner, and the scan files were imported into a 3-dimensional analysis software (Geomagic Control X). The linear deviations of 2 standardized points on the scan body used during digitization were automatically calculated on x-, y-, and z-axes. Average deviations were used to define precision, and 1-way analysis of variance and Tukey HSD tests were used for statistical analyses (α = 0.05). RESULTS: Biobased model resin led to higher deviations than dental stone (all axes, P ≤ 0.031) and model resin (y-axis, P = 0.015). Biobased model resin resulted in the lowest precision of implant analog position (P ≤ 0.049). The difference in the positional accuracy of implant analogs of model resin and stone casts was nonsignificant (P ≥ 0.196). CONCLUSIONS: Implant analogs in biobased model resin casts mostly had lower positional accuracy, whereas those in model resin and stone casts had similar positional accuracy. Regardless of the material, analogs deviated more towards mesial, while buccal deviations in additively manufactured casts and lingual deviations in stone casts were more prominent.


Assuntos
Desenho Assistido por Computador , Materiais para Moldagem Odontológica , Técnica de Moldagem Odontológica , Modelos Dentários , Polivinil , Siloxanas , Humanos , Polivinil/química , Siloxanas/química , Materiais para Moldagem Odontológica/química , Planejamento de Prótese Dentária , Imageamento Tridimensional/métodos , Sulfato de Cálcio/química , Resinas Sintéticas/química , Implantes Dentários , Mandíbula , Técnica de Fundição Odontológica , Teste de Materiais
17.
J Dent ; 146: 105045, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38714241

RESUMO

OBJECTIVES: This in vitro study compared the accuracy of conventional versus digital impression techniques for angulated and straight implants using two different impression coping and scan body designs. METHODS: Two implant systems were used: Straumann and Dentegris. Two implants were placed for each system, straight and angulated at 15 degrees mesiodistally. Conventional impressions were made using the splinted open-tray technique using narrow impression coping (NIC) and wide impression coping (WIC). The stone casts produced from the conventional impression were digitized with a lab scanner (3Shape D2000). Digital impressions were made using four intraoral scanners (IOS): 3Shape Trios 3, Medit i700, Cerec Omnicam, and Emerald Planmeca using short scanbodies (SSB) and long scanbodies (LSB). The scanning was repeated ten times to generate the Standard Tessellation Language (STL) files. The distance and angle deviations between impression copings and scanbodies were measured in reference to the master model. RESULTS: The trueness and precision of SSB and WIC were significantly better than LSB and NIC (p<0.001). The range trueness of the platform deviation was better with SSB (37.1 to 51.9) than LSB (89.6 to 127.9 µm) and for WIC than NIC in conventional impressions (58.2 and 75.1 µm, respectively). The trueness of the angle deviation of digital scans with SSB (0.11 to 0.25 degrees) was significantly better than scans with LSB (0.31 to 0.57 degrees) and for WIC than NIC (0.21 and 0.52 degrees, respectively). The precision of the platform deviation of digital scans with SSB (12.4 to 34.5 µm) was higher than other scans and conventional impressions (42.9 to 71.4 µm). The precision of the angle deviation of Medit i700 and Trios 3 with SSB (0.17 and 0.20 degrees, respectively) was higher than other scans with SSB and conventional impressions (0.54 to 1.63 degrees). CONCLUSIONS: Digital scans with SSB were more accurate than conventional splinted open-tray impressions. The type of impression coping and scanbody significantly affected the impression accuracy. CLINICAL SIGNIFICANCE: The use of a short scanbody can increase the accuracy of digital impressions, and wide impression coping can increase the accuracy of conventional impressions, resulting in improved clinical outcomes.


Assuntos
Desenho Assistido por Computador , Implantes Dentários , Técnica de Moldagem Odontológica , Humanos , Planejamento de Prótese Dentária , Processamento de Imagem Assistida por Computador/métodos , Materiais para Moldagem Odontológica , Modelos Dentários
18.
Clin Implant Dent Relat Res ; 26(4): 714-723, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38727015

RESUMO

OBJECTIVES: This study aimed to compare the accuracy of implant-level conventional and digital impressions for atrophied maxillary ridges. MATERIALS AND METHODS: Twelve participants with atrophied edentulous maxillary ridges received six implants. Six months later and after soft tissue maturation around healing abutments, a control cast was constructed using the final passive restoration for each patient. Two types of implant-level impression techniques were carried out for each patient: (1) conventional (splinted open-tray) impression technique and (2) digital impression technique. For both techniques, scan bodies were labeled from the most distal implant on the left side (A, B, C, D, E, and F) and scanning was made. Accuracy of both techniques was measured using in vitro (two-dimensional and three-dimensional) and in vivo (clinical) methods. Two-dimensional methods include measurement of the difference in linear distances AB, AC AD, AE, and AF. Geomagic software was used to assess the three-dimensional deviation between the two impression techniques using the superimposition of standard tessellation language files. The incidence and percentage of nonpassive frameworks and framework misfits of final restorations for both types of impression techniques were assessed using the single screw test. RESULTS: For all distances, digital impressions recorded significantly higher deviation from control measurements than conventional impressions. The highest two-dimensional linear deviation was noted for AF distance and the lowest difference was noted for AB distance. For all scan bodies, digital impressions recorded significantly higher three-dimensional deviation than conventional impressions. The highest three-dimensional deviation was noted with scan bodies C and D. Digital impressions recorded a significantly higher incidence of nonpassive frameworks and framework misfits than conventional impressions. [Correction added on 11 June 2024, after first online publication: In the preceding sentence, "digital impressions" was changed to "conventional impressions" in this version.] CONCLUSION: Within the limitations of this study, it could be concluded that the conventional implant-level impression technique showed greater in vitro and in vivo accuracy than the digital impression technique when used for full-arch maxillary fixed restorations on inclined implants.


Assuntos
Estudos Cross-Over , Técnica de Moldagem Odontológica , Maxila , Humanos , Maxila/cirurgia , Masculino , Feminino , Prótese Dentária Fixada por Implante , Pessoa de Meia-Idade , Desenho Assistido por Computador , Idoso , Implantes Dentários , Arcada Edêntula/reabilitação
19.
J Dent ; 148: 105044, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38710316

RESUMO

OBJECTIVES: To compare the trueness of maxillomandibular relationship between articulated 3D-printed and conventional diagnostic casts in maximum intercuspation (MIP). METHODS: Reference casts were articulated in MIP, and scanned using a Coordinate Measurement Machine (CMM, n = 1). Digital scans were made from the reference casts by using an intraoral scanner (IOS, n = 10) (Trios 4; 3Shape A/S). IOS scans were processed to create 3D-printed casts by using MAX UV385 (Asiga) and NextDent 5100 (3DSystems) 3D-printers. The conventional workflow implemented vinylpolysiloxane (VPS) impressions and Type IV stone. Stone and 3D-printed casts were articulated and digitized with a laboratory scanner (E4; 3Shape A/S). The 3D-printed casts were scanned on two occasions: with and without positioning pins. Inter-arch distances and 3D-contact area were measured and compared. Statistical tests used were Shapiro-Wilk, Levene's, Welch's t-test, and 2-way ANOVA (α=0.05). RESULTS: IOS group showed similar or better maxillomandibular relationship trueness than stone casts and 3D-printed casts (p < 0.05). 3D-contact area analysis showed similar deviations between 3D-printed and stone casts (p > 0.05). The choice of 3D-printer and presence of positioning pins on the casts significantly influenced maxillomandibular relationship trueness (p < 0.05). CONCLUSIONS: Articulated 3D-printed and stone casts exhibited similar maxillomandibular relationship trueness. CLINICAL SIGNIFICANCE: Although 3D-printing methods can introduce a considerable amount of deviations, the maxillomandibular relationship trueness of articulated 3D-printed and stone casts in MIP can be considered similar.


Assuntos
Materiais para Moldagem Odontológica , Técnica de Moldagem Odontológica , Maxila , Modelos Dentários , Impressão Tridimensional , Siloxanas , Humanos , Maxila/anatomia & histologia , Materiais para Moldagem Odontológica/química , Siloxanas/química , Técnica de Moldagem Odontológica/instrumentação , Registro da Relação Maxilomandibular/instrumentação , Polivinil/química , Desenho Assistido por Computador , Mandíbula/anatomia & histologia , Mandíbula/diagnóstico por imagem , Imageamento Tridimensional/métodos , Processamento de Imagem Assistida por Computador/métodos , Arco Dental/anatomia & histologia , Arco Dental/diagnóstico por imagem , Sulfato de Cálcio/química , Articuladores Dentários
20.
J Oral Implantol ; 50(4): 426-430, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38733201

RESUMO

The optimal scan pattern for full-arch digital implant impressions remains to be determined. This study aimed to analyze the effects of different scan patterns on the trueness of intraoral scanners for full-arch digital implant impressions. A maxillary plaster model with 4 implant analogs was employed as the master model. Scan bodies were attached to the master model and scanned with a laboratory scanner to obtain reference data. Test scans were obtained using 3 different scan patterns with Cerec Primescan and Trios 3. Each test datum was superimposed onto the reference data. The trueness was assessed by determining the 3D distance and angular deviations between the test and reference data. Significant differences in 3D distance deviation were detected among the scan patterns for both scanners. Significant differences in angle deviation were detected among the scan patterns for the Cerec Primescan, whereas it was not substantial for the Trios 3. Cerec Primescan exhibited superior trueness across all scan patterns compared with Trios 3. The zigzag pattern resulted in more accurate scans for the Cerec Primescan, whereas both the zigzag and occlusal-palatal-buccal patterns showed higher accuracy for the Trios 3.


Assuntos
Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Técnica de Moldagem Odontológica/instrumentação , Humanos , Imageamento Tridimensional , Modelos Dentários , Implantes Dentários , Maxila/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...