Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.855
Filtrar
2.
Anal Bioanal Chem ; 416(20): 4635-4645, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38949681

RESUMO

17α-Hydroxyprogesterone (17α-OHP) quantification in dried blood spots (DBS) is essential for newborn screening for congenital adrenal hyperplasia (CAH), which is challenging due to its low physiological concentration. The high false-positive rates of immunoassays necessitate the development of more accurate methods. Liquid chromatography tandem mass spectrometry (LC-MS/MS) offers increased specificity and sensitivity, yet standardized procedures for 17α-OHP measurement are required for clinical application. A candidate reference measurement procedure (cRMP) using isotope dilution LC-MS/MS was developed for 17α-OHP quantification in DBS. By utilizing stable isotope-labeled D8-17α-OHP as an internal standard, the cRMP was optimized, covering sample preparation, calibration, and LC-MS/MS analysis. The method performance was validated across several parameters, including precision, accuracy, specificity, detection limits, and matrix effects. Clinical applicability was further assessed through the establishment of reference intervals for healthy newborns. The developed cRMP exhibited a linear range of 1.00 to 80.00 ng/mL for 17α-OHP, with detection and quantification limits of 0.14 ng/mL and 0.52 ng/mL, respectively. Inter- and intraday precision demonstrated coefficients of variation within 1.27 to 5.69%. The recovery rates and matrix effects were well within acceptable limits, ensuring method reliability. Clinical application showed distinct reference intervals for healthy newborns that were unaffected by sex but influenced by weight and gestational age. This method significantly enhances CAH diagnostic accuracy in newborns, providing a valuable tool for clinical laboratories and improving newborn screening program standardization and traceability.


Assuntos
17-alfa-Hidroxiprogesterona , Teste em Amostras de Sangue Seco , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Teste em Amostras de Sangue Seco/métodos , 17-alfa-Hidroxiprogesterona/sangue , Recém-Nascido , Cromatografia Líquida/métodos , Limite de Detecção , Padrões de Referência , Hiperplasia Suprarrenal Congênita/sangue , Hiperplasia Suprarrenal Congênita/diagnóstico , Triagem Neonatal/métodos , Reprodutibilidade dos Testes , Técnicas de Diluição do Indicador , Feminino , Valores de Referência
3.
Food Chem ; 455: 139956, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-38843713

RESUMO

Pineapple aroma is one of the most important sensory quality traits that influences consumer purchasing patterns. Reported in this paper is a high throughput method to quantify in a single analysis the key volatile organic compounds that contribute to the aroma of pineapple cultivars grown in Australia. The method constituted stable isotope dilution analysis in conjunction with headspace solid-phase microextraction coupled with gas-chromatography mass spectrometry. Deuterium labelled analogues of the target analytes purchased commercially were used as internal standards. Twenty-six volatile organic compounds were targeted for quantification and the resulting calibration functions of the matrix -matched validated method had determination coefficients (R2) ranging from 0.9772 to 0.9999. The method was applied to identify the key aroma volatile compounds produced by popular pineapple cultivars such as 'Aus Carnival', 'Aus Festival', 'Aus Jubilee', 'Aus Smooth (Smooth Cayenne)' and 'Aussie Gold (73-50)', grown in Queensland, Australia. Pineapple cultivars varied in its content and composition of free volatile components, which were predominantly comprised of esters, followed by terpenes, alcohols, aldehydes, and ketones.


Assuntos
Ananas , Cromatografia Gasosa-Espectrometria de Massas , Odorantes , Microextração em Fase Sólida , Compostos Orgânicos Voláteis , Ananas/química , Compostos Orgânicos Voláteis/química , Compostos Orgânicos Voláteis/análise , Austrália , Odorantes/análise , Técnicas de Diluição do Indicador
4.
Anal Bioanal Chem ; 416(13): 3117-3125, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38589614

RESUMO

In this study, we demonstrate the applicability of nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (MICAP-MS) for Ca, Fe, and Se quantification in human serum using isotope dilution (ID) analysis. The matrix tolerance of MICAP-MS in Na matrix was investigated, revealing that high Na levels can suppress the signal intensity. This suppression is likely due to the plasma loading and the space charge effect. Moreover, 40Ca and 44Ca isotopic fractionation was noted at elevated Na concentration. Nine certified serum samples were analyzed using both external calibration and ID analysis. Overestimation of Cr, Zn, As, and Se was found in the results of external calibration, which might result from C-induced polyatomic interference and signal enhancement, respectively. Further investigations performed with methanol showed a similar enhancement effect for Zn, As, and Se, potentially supporting this assumption. The mass concentrations determined with ID analysis show metrological compatibility with the reference values, indicating that MICAP-MS combined with ID analysis can be a promising method for precise Ca, Fe, and Se determination. Moreover, this combination reduces the influence of matrix effects, broadening the applicability of MICAP-MS for samples with complex matrixes.


Assuntos
Pressão Atmosférica , Cálcio , Ferro , Espectrometria de Massas , Micro-Ondas , Nitrogênio , Selênio , Humanos , Ferro/sangue , Cálcio/sangue , Espectrometria de Massas/métodos , Selênio/sangue , Técnicas de Diluição do Indicador
5.
Arch Anim Nutr ; 78(1): 95-107, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38567675

RESUMO

The aim was to determine ileal endogenous nitrogen losses (ENL) and true ileal N-digestibility (TD-N) under non-steady-state conditions of the 15N-isotope dilution technique (15N-IDT), using diets generating low and high ENL and compare results to those obtained under steady-state conditions. Twelve growing pigs (mean LW 22.4 kg) fitted with a post-valve T-caecum cannula were fed an enzyme-hydrolysed casein (EHC)-based diet or an EHC diet + 4% quebracho tannins (QT) and were labelled via continuous 15N-leucine i.v. infusion or twice daily oral 15N-leucine administration. Digesta were collected daily over three consecutive hours with blood plasma sampled on the four consecutive days after cessation of 15N-labelling. There was a significant effect of sampling day on the dilution factor. Endogenous N losses were significantly lower for the EHC than the EHC+QT diet (2.41 vs. 8.69 g/kg DMI), while no significant effect of sampling day was observed. The TD-N of the EHC+QT diet did not differ from the TD-N of the EHC diet (95.1 vs. 92.0%). A significant effect of sampling day was observed for TD-N with day 1 and 2, being higher than day 4. Non-steady-state conditions overestimated ENL by 25-28% as compared to 3 h collections in steady-state conditions, but the relative overestimation was similar for the EHC diet as for the EHC+QT diet. TD-N did not differ significantly compared to 12 h steady-state measurements, but comparison to 3 h steady-state measurements showed that non-steady-state conditions overestimated TD-N for the EHC+QT diet by 9%. However, on day 4 this overestimation disappeared. Using the 15N-IDT during non-steady-state conditions can provide valuable additional data on endogenous N losses and TD-N.


Assuntos
Ração Animal , Dieta , Digestão , Íleo , Isótopos de Nitrogênio , Nitrogênio , Animais , Íleo/fisiologia , Íleo/metabolismo , Nitrogênio/metabolismo , Digestão/efeitos dos fármacos , Digestão/fisiologia , Dieta/veterinária , Ração Animal/análise , Fenômenos Fisiológicos da Nutrição Animal , Masculino , Sus scrofa/fisiologia , Técnicas de Diluição do Indicador/veterinária , Suínos/fisiologia , Feminino
6.
Anal Bioanal Chem ; 416(14): 3447-3458, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38642097

RESUMO

N-Terminal pro-B-type natriuretic peptide (NT-proBNP) is a pivotal biomarker for the diagnosis and prognosis of heart failure (HF). However, no SI-traceable certified reference material (CRM) or reference measurement procedure (RMP) is available for this biomarker, and so clinical testing results obtained in different laboratories cannot be traced to a higher-order standard, leading to incomparable measurements. Protein hydrolysis and protein cleavage isotope dilution mass spectrometry (AAA-IDMS and PepA-IDMS) were used to develop a CRM. Structurally related impurities were identified by high-resolution mass spectrometry. The quantitative AAA-IDMS results were corrected according to the amino acid compositions of the impurities. Using PepA-IDMS, two peptides from the proteolyzed product were confirmed as signature peptides. To obtain traceable and accurate results, the signature peptides were quantified using impurity-corrected AAA-IDMS. The candidate NT-proBNP solution was denatured and enzymatically digested using the Glu-C endoproteinase. The released signature peptides were measured using an isotopic dilution approach. The homogeneity and stability of the candidate CRM were characterized, and their uncertainties were combined with the value assignment process. The developed CRM can be considered a unique SI-traceable NT-proBNP reference material and is expected to be used as a primary calibrator for matrix NT-proBNP CRM development.


Assuntos
Espectrometria de Massas , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos , Padrões de Referência , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/análise , Humanos , Espectrometria de Massas/métodos , Biomarcadores/sangue , Biomarcadores/análise , Técnicas de Diluição do Indicador
7.
Clin Chem Lab Med ; 62(7): 1339-1351, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38515344

RESUMO

OBJECTIVES: A reference measurement procedure (RMP) using isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) was developed and validated with the aim of accurately measuring carbamazepine-10,11-epoxide concentrations in human serum and plasma. METHODS: To establish traceability to SI units, the absolute content of the reference material was determined using quantitative nuclear magnetic resonance (qNMR) spectroscopy. As sample preparation a protein precipitation protocol followed by a high dilution step was established. Chromatographic separation from carbamazepine and potential metabolites was achieved using a C18 stationary phase. Selectivity, specificity, matrix effects, precision and accuracy, inter-laboratory equivalence, and uncertainty of measurement were evaluated based on guidelines from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement. RESULTS: The RMP demonstrated very good selectivity and specificity, showing no evidence of a matrix effect. This enabled accurate quantification of carbamazepine-epoxide in the concentration range of 0.0400-12.0 µg/mL. The intermediate precision was found to be less than 2.1 %, and the repeatability coefficient of variation (CV) ranged from 1.2 to 1.8 % across all concentration levels. Regarding accuracy, the relative mean bias varied from 1.4 to 2.5 % for native serum levels and from 1.4 to 3.5 % for Li-heparin plasma levels. The measurement uncertainty for single measurements ranged from 1.6 to 2.1 %. CONCLUSIONS: In this study, we introduce a new LC-MS/MS-based candidate RMP for accurately measuring carbamazepine-10,11-epoxide in human serum and plasma. This novel method offers a traceable and dependable platform, making it suitable for standardizing routine assays and assessing clinically relevant samples.


Assuntos
Carbamazepina , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Carbamazepina/sangue , Carbamazepina/análogos & derivados , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Padrões de Referência , Técnicas de Diluição do Indicador , Espectrometria de Massa com Cromatografia Líquida
8.
Clin Chem Lab Med ; 62(7): 1327-1338, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38549258

RESUMO

OBJECTIVES: Primidone is an anticonvulsive drug used in the treatment of epilepsy and essential tremor. It offers beneficial effects in controlling seizures, but its usage is also associated with possible side effects. To ensure optimal therapy, it is crucial to measure its concentration through accurate quantification methods. Therefore, our main goal was to develop and validate a new reference measurement procedure (RMP) for accurately measuring primidone levels in human serum and plasma. METHODS: In our study, we focused on the separation of primidone from both known and unknown interferences using a C18 column. To achieve accurate sample preparation, we developed a protocol involving protein precipitation followed by a high dilution step. The validation of the assay and determination of measurement uncertainty were carried out following guidelines from organizations such as the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement. These rigorous validation processes ensure the reliability and accuracy of our method for quantifying primidone levels in human serum and plasma samples. RESULTS: The RMP was shown to be highly selective and specific, with no evidence of matrix interference. It can be used to quantify primidone in the range of 0.150-30.0 µg/mL. Intermediate precision was less than 4.0 %, and repeatability CV ranged from 1.0 to 3.3 % across all concentration levels. The relative mean bias ranged from 0.1 to 3.9 % for native serum levels, and from -2.6 to 2.8 % for lithium-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment were 1.5-4.1 % and 0.9-1.0 %, respectively. CONCLUSIONS: In this study, we introduce an innovative LC-MS/MS-based candidate RMP specifically designed for primidone in human serum and plasma. Our RMP offers a traceable platform, facilitating the standardization of routine assays and enabling the evaluation of clinically relevant samples. With this novel approach, we aim to enhance the accuracy and reliability of primidone measurements, ultimately benefiting the field of clinical research and patient care.


Assuntos
Primidona , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Primidona/sangue , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Padrões de Referência , Reprodutibilidade dos Testes , Técnicas de Diluição do Indicador , Limite de Detecção , Anticonvulsivantes/sangue , Espectrometria de Massa com Cromatografia Líquida
9.
J Chromatogr A ; 1720: 464764, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38458137

RESUMO

The limit of detection (LOD) is a crucial measure in analytical methods, representing the smallest amount of a substance that can be distinguished from background noise. In the realm of gas chromatography (GC), however, determining LOD can be quite subjective, leading to significant variability among researchers. In this study, we validate the Hubaux-Vos method, an International Standards Organization(ISO)-approved approach for determining LOD in gas concentration measurements, using a GC equipped with a discharge ionization detector (DID) and a dynamic dilution system. We employ a gas mixture certified reference material (CRM) of CO, CH4, and CO2 at various concentrations to generate calibration curves for each gas. Subsequently, we estimate the LODs for each gas using the Hubaux-Vos method. Surprisingly, our findings indicate a notable difference between the LODs calculated using the Hubaux-Vos method and those confirmed through experiments. This highlights the importance of critically examining the theoretical foundations of LOD determination. We strongly recommend researchers to scrutinize the principles guiding LOD determination. The method proposed in this study offers an effective way to rigorously validate theoretical approaches for estimating LODs in gas concentration measurements using GC.


Assuntos
Limite de Detecção , Cromatografia Gasosa/métodos , Calibragem , Padrões de Referência , Técnicas de Diluição do Indicador
10.
Clin Chem Lab Med ; 62(7): 1314-1326, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38407268

RESUMO

OBJECTIVES: Phenobarbital serves as an antiepileptic drug (AED) and finds application in the treatment of epilepsy either as monotherapy or adjunctive therapy. This drug exhibits various pharmacodynamic properties that account for its beneficial effects as well as potential side effects. Accurate measurement of its concentration is critical for optimizing AED therapy through appropriate dose adjustments. Therefore, our objective was to develop and validate a new reference measurement procedure (RMP) for the accurate quantification of phenobarbital levels in human serum and plasma. METHODS: A sample preparation protocol based on protein precipitation followed by a high dilution step was established in combination with a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method using a C8 column to separate target analytes from known and unknown interferences. Assay validation and determination of measurement uncertainty were performed based on current guidelines. Selectivity and Specificity were assessed using spiked serum and plasma samples; to investigate possible matrix effects (MEs) a post-column infusion experiment and a comparison of standard line slopes was performed. Precision and accuracy were determined within a multiday precision experiment. RESULTS: The RMP was shown to be highly selective and specific, with no evidence of matrix interferences. It can be used to quantify phenobarbital in the range of 1.92 to 72.0 µg/mL. Intermediate precision was less than 3.2 %, and repeatability coefficient of variation (CV) ranged from 1.3 to 2.0 % across all concentration levels. The relative mean bias ranged from -3.0 to -0.7 % for native serum levels, and from -2.8 to 0.8 % for Li-heparin plasma levels. The measurement uncertainties (k=1) for single measurements and target value assignment were 1.9 to 3.3 % and 0.9 to 1.6 %, respectively. CONCLUSIONS: A novel LC-MS/MS-based candidate RMP for the quantification of phenobarbital in human serum and plasma is presented which can be used for the standardization of routine assays and the evaluation of clinically relevant samples.


Assuntos
Fenobarbital , Espectrometria de Massas em Tandem , Humanos , Fenobarbital/sangue , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Anticonvulsivantes/sangue , Padrões de Referência , Análise Química do Sangue/métodos , Análise Química do Sangue/normas , Técnicas de Diluição do Indicador , Espectrometria de Massa com Cromatografia Líquida
11.
Sci Rep ; 14(1): 268, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38168473

RESUMO

Omicron variant (B.1.1.529) is able to escape from naturally acquired and vaccine-induced immunity, which mandates updating the current COVID-19 vaccines. Here, we investigated and compared the neutralising antibody induction of the ancestral variant-based BIV1-CovIran vaccine, the Omicron variant-based BIV1-CovIran Plus vaccine, and the novel bivalent vaccine candidate, BBIV1-CovIran, against the Omicron and ancestral Wuhan variants on the rat model. After inactivating the viral particles, the viruses were purified and formulated. Bivalent vaccines were a composition of 2.5 µg (5 µg total) or 5 µg (10 µg total) doses of each ansectral-based and Omicron-based monovalent vaccine. Subsequently, the potency of the monovalent and bivalent vaccines was investigated using the virus neutralisation test (VNT). The group that received three doses of the Omicron-specific vaccine demonstrated neutralisation activity against the Omicron variant with a geometric mean titer of 337.8. However, three doses of the Wuhan variant-specific vaccine could neutralise the Omicron variant at a maximum of 1/32 serum dilution. The neutralisation activity of the Omicron-specific vaccine, when administered as the booster dose after two doses of the Wuhan variant-specific vaccine, was 100% against the Omicron variant and the Wuhan variant at 1/64 and 1/128 serum dilution, respectively. Three doses of 5 µg bivalent vaccine could effectively neutralise both variants at the minimum of 1/128 serum dilution. The 10 µg bivalent vaccine at three doses showed even higher neutralisation titers: the geometric mean of 388 (95% CI 242.2-621.7) against Omicron and 445.7 (95% CI 303.3-655.0) against Wuhan. It is shown that the candidate bivalent and Omicron-specific vaccines could elicit a potent immune response against both Wuhan-Hu-1 and Omicron BA.1 variants.


Assuntos
Anticorpos Neutralizantes , Vacinas contra COVID-19 , Animais , Humanos , Ratos , Vacinas Combinadas , Modelos Animais , Técnicas de Diluição do Indicador , Anticorpos Antivirais
12.
Int J Mol Sci ; 25(1)2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38203831

RESUMO

Physicochemical examinations of very high dilution (UHD) solutions subjected to certain physical factors (such as shaking) are becoming more frequent and are increasingly producing conclusive results. A much less studied phenomenon is the transfer of molecular information (i.e., UHD signals of dilute substances) from one liquid to another without an intermediate liquid phase. The aim of this study was to investigate the possibility of such a transfer of the UHD signal from the UHD solutions to the receiver solution, in particular, if the molecular source used in the donor solutions was the biologically active antibodies to interferon-gamma molecule. We were especially interested in how the transfer of the UHD signal is affected by the time of exposure of the receiver to the donor, the distance between the two, and how the transfer is affected by activation (striking) versus exposure alone. Signal transfer was evaluated by differential measurements of electrical conductivity, ORP, pH, and UV/VIS spectroscopy of the exposed liquid. The results showed that activation strongly influences signal transfer and that this can be compensated to some extent by prolonged direct exposure. In principle, exposure time has a positive effect on signal transfer. Interestingly, the results of different distances between the donor and receiver showed similar changes in the parameters in the range of 0-4 cm, as estimated in this study. While the study mainly confirms the two hypotheses, it also raises a number of new questions and provides clues for further research.


Assuntos
Anticorpos , Interferon gama , Condutividade Elétrica , Técnicas de Diluição do Indicador
13.
Clin Chem Lab Med ; 62(7): 1288-1300, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38105272

RESUMO

OBJECTIVES: To describe and validate an isotope dilution-liquid chromatograph-tandem mass spectrometry (ID-LC-MS/MS) based reference measurement procedure (RMP) for zonisamide to accurately measure serum and plasma concentrations. METHODS: Quantitative nuclear magnetic resonance (qNMR) spectroscopy was employed to determine the absolute content of the reference material used in order to establish traceability to SI units. Separation of zonisamide from known or unknown interferences was performed on a C8 column. For sample preparation a protocol based on protein precipitation in combination with a high dilution step was established. Assay validation and determination of measurement uncertainty were performed based on guidelines from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the expression of uncertainty in measurement. RESULTS: The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of zonisamide within the range of 1.50-60.0 µg/mL. Intermediate precision was <1.4 % and repeatability CV ranged from 0.7 to 1.2 % over all concentration levels. The relative mean bias ranged from 0.0 to 0.8 % for native serum levels and from 0.2 to 2.0 % for Li-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment ranged from 1.1 to 1.4 % and 0.8-1.0 %, respectively. CONCLUSIONS: We present a novel LC-MS/MS-based candidate RMP for zonisamide in human serum and plasma which provides a traceable and reliable platform for the standardization of routine assays and evaluation of clinically relevant samples.


Assuntos
Isoxazóis , Espectrometria de Massas em Tandem , Zonisamida , Humanos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Zonisamida/sangue , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Isoxazóis/sangue , Padrões de Referência , Técnicas de Diluição do Indicador , Análise Química do Sangue/métodos , Análise Química do Sangue/normas , Espectrometria de Massa com Cromatografia Líquida
14.
Artigo em Inglês | MEDLINE | ID: mdl-38135279

RESUMO

BACKGROUND: The D3-creatine (D3-Cr) dilution method is of emerging interest for estimating total-body skeletal muscle mass. This review explores the association of muscle mass estimated via D3-Cr with various clinical outcomes and provides a summary of the literature comparing D3-Cr with other body composition techniques. METHODS: A literature search was conducted on PubMed/MEDLINE and Web of Science for studies using D3-Cr to measure muscle in adult populations (ie, ≥18 years old) from inception until September 2023. RESULTS: Out of the 23 included studies, 15 investigated the correlation between D3-Cr and clinical outcomes. More consistent associations were reported for mortality (100%, n = 2), mobility disability (100%; n = 5), falls and fractures (100%; n = 3), physical performance (63.3%; n = 11), muscle strength (44.4%; n = 9), and muscle composition (33.3%; n = 3). However, conflicting findings were also reported for such correlations. Among the 23 studies, 14 compared D3-Cr-estimated muscle with other body composition techniques, including magnetic resonance imaging (MRI) as a reference method. Strong and positive correlations were found between D3-Cr and MRI. Nonetheless, variations in muscle measurements were noted, with differences in D3-Cr values ranging from 0.62 kg lower to 13.47 kg higher compared to MRI. CONCLUSIONS: D3-Cr-estimated muscle mass may be a valuable predictor of clinical outcomes showing consistent associations with falls and fractures, mobility disability, and mortality. However, less consistent associations were found with muscle strength and composition, and physical performance. Although a strong correlation exists between D3-Cr-estimated muscle mass and MRI measurements, under- or overestimation may occur.


Assuntos
Creatina , Músculo Esquelético , Composição Corporal/fisiologia , Creatina/metabolismo , Técnicas de Diluição do Indicador , Força Muscular , Músculo Esquelético/metabolismo , Adulto
15.
Sci Rep ; 13(1): 15504, 2023 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-37726378

RESUMO

Real-time and accurate estimation of surgical hemoglobin (Hb) loss is essential for fluid resuscitation management and evaluation of surgical techniques. In this study, we aimed to explore a novel surgical Hb loss estimation method using deep learning-based medical sponges image analysis. Whole blood samples of pre-measured Hb concentration were collected, and normal saline was added to simulate varying levels of Hb concentration. These blood samples were distributed across blank medical sponges to generate blood-soaked sponges. Eight hundred fifty-one blood-soaked sponges representing a wide range of blood dilutions were randomly divided 7:3 into a training group (n = 595) and a testing group (n = 256). A deep learning model based on the YOLOv5 network was used as the target region extraction and detection, and the three models (Feature extraction technology, ResNet-50, and SE-ResNet50) were trained to predict surgical Hb loss. Mean absolute error (MAE), mean absolute percentage error (MAPE), coefficient (R2) value, and the Bland-Altman analysis were calculated to evaluate the predictive performance in the testing group. The deep learning model based on SE-ResNet50 could predict surgical Hb loss with the best performance (R2 = 0.99, MAE = 11.09 mg, MAPE = 8.6%) compared with other predictive models, and Bland-Altman analysis also showed a bias of 1.343 mg with narrow limits of agreement (- 29.81 to 32.5 mg) between predictive and actual Hb loss. The interactive interface was also designed to display the real-time prediction of surgical Hb loss more intuitively. Thus, it is feasible for real-time estimation of surgical Hb loss using deep learning-based medical sponges image analysis, which was helpful for clinical decisions and technical evaluation.


Assuntos
Aprendizado Profundo , Hidratação , Hemoglobinas , Técnicas de Diluição do Indicador , Ressuscitação
16.
Int J Mol Sci ; 24(17)2023 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-37685837

RESUMO

The optical properties of indocyanine green (ICG) as a near-infrared (NIR) fluorescence dye depend on the nature of the solvent medium and the dye concentration. In the ICG absorption spectra of water, at high concentrations, there were absorption maxima at 700 nm, implying H-aggregates. With ICG dilution, the main absorption peak was at 780 nm, implying monomers. However, in ethanol, the absorption maximum was 780 nm, and the shapes of the absorption spectra were identical regardless of the ICG concentration, indicating that ICG in ethanol exists only as a monomer without H-aggregates. We found that emission was due to the monomer form and decreased with H-aggregate formation. In the fluorescence spectra, the 820 nm emission band was dominant at low concentrations, whereas at high concentrations, we found that the emission peaks were converted to 880 nm, suggesting a new form via the twisted intramolecular charge transfer (TICT) process of ICG. The NIR fluorescence intensity of ICG in ethanol was approximately 12- and 9-times brighter than in water in the NIR-I and -II regions, respectively. We propose an energy diagram of ICG to describe absorptive and emissive transitions through the ICG structures such as the monomer, H-aggregated, and TICT monomer forms.


Assuntos
Etanol , Verde de Indocianina , Corantes Fluorescentes , Técnicas de Diluição do Indicador , Água
17.
Wei Sheng Yan Jiu ; 52(4): 579-610, 2023 Jul.
Artigo em Chinês | MEDLINE | ID: mdl-37679071

RESUMO

OBJECTIVE: This study optimizes three-dimensional(3D)culture conditions of L02 cells using response surface methodology(RSM) based on the VitroGel system to construct the hepatocytes model in vitro. METHODS: L02 cells were 3D cultured by the VitroGel system. The appropriate level of three key factors(concentration of inoculated cells, culture time and dilution degree of the hydrogel) was determined by single-factor experiment, and the optimal conditions of 3D culture of L02 cells based on the VitroGel system were determined by RSM. During the detection process, the optical density(OD) value of cell viability was used as the detection index, and the cell viability was detected using the cell counting kit-8(CCK-8) assay. The proliferative performance and viability of L02 cells was measured by fluorescent staining assay. RESULTS: The selected optimal culture conditions by RSM were as follows: concentration of inoculated cells was 1.1 × 10~5/mL, culture time was 9.5 days, and dilution degree of hydrogel was 1∶3.7. The result shows that under optimal conditions, the predicted OD value of cell viability was 2.17 and measured 2.13 with a relative error of 1.84%, indicating that the condition was suitable and reliable. The fluorescent staining and dead and live cells detection results showed the 3D hepatocytes model was successfully constructed. CONCLUSION: The optimal conditions for 3D culture of L02 cell based on the VitroGel system were determined by RSM, and a hepatocytes model with high cellular activity was successfully constructed.


Assuntos
Hepatócitos , Hidrogéis , Sobrevivência Celular , Técnicas de Diluição do Indicador
18.
J Clin Lab Anal ; 37(13-14): e24955, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37571860

RESUMO

BACKGROUND: This study aimed to assess the commutability of frozen pooled human serum (PHS), high concentration of Immunoglobulin M (IgM) pure diluted materials (HPDM), commercialized pure materials (CPM), and dilutions of ERM-DA470k/IFCC in IgM detection using the CLSI and IFCC approaches, to support standardization or harmonization of IgM measurement. METHODS: Twenty-four serum samples, relevant reference materials (PHS, HPDM, CPM), and different ERM-DA470k/IFCC dilutions were analyzed in triplicate using six routine methods. The commutability of the relevant reference materials was carried out following CLSI EP30-A and IFCC bias analysis. RESULTS: According to the CLSI approach, low, medium, and high concentrations of PHS, HPDM, and CPM were commutable on 10, 13, 15, 13, and 8 of 15 assay combinations, respectively. Using the IFCC approach, low, medium, and high concentrations of PHS, HPDM, and CPM were commutable on 10, 11, 9, 15, and 10 of 15 assay combinations, respectively. The ERM-DA470k/IFCC dilutions with D-PBS and RPMI-1640 Medium were commutable on 13 of 15 assay combinations according to CLSI and were commutable on all 15 assay combinations using IFCC approach. CONCLUSIONS: High concentration of PHS were commutable on all six detection systems using the CLSI approach. Low and medium concentration of PHS showed unsatisfied commutability. HPDM, not CPM have good commutability, has the potential to become reference materials. ERM-DA470k/IFCC diluted with different medium showed different commutability.


Assuntos
Soro , Humanos , Padrões de Referência , Testes de Coagulação Sanguínea , Imunoglobulina M , Técnicas de Diluição do Indicador
19.
Clin Chem Lab Med ; 61(11): 1942-1954, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37466369

RESUMO

OBJECTIVES: Topiramate is an antiepileptic drug (AED) used for the monotherapy or adjunctive treatment of epilepsy and for the prophylaxis of migraine. It has several pharmacodynamic properties that contribute to both its clinically useful properties and observed adverse effects. Accurate measurement of its concentration is therefore essential for dose adjustment/optimisation of AED therapy. Our aim was to develop and validate a novel reference measurement procedure (RMP) for the quantification of topiramate in human serum and plasma. METHODS: An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) method in combination with a protein-precipitation-based sample preparation allows for quantification of topiramate in human serum and plasma. To assure traceability to SI units, quantitative nuclear magnetic resonance (qNMR) was applied to characterize the reference material used as primary calibrator for this RMP. Matrix effects were determined by performing a post-column infusion experiment and comparing standard line slopes. Accuracy and precision was evaluated performing an extensive five day precision experiment and measurement uncertainty was evaluated according Guide to the Expression of Uncertainty in Measurement (GUM). RESULTS: The method enabled topiramate quantification within the range of 1.20-36.0 µg/mL without interference from structurally related compounds and no evidence of a matrix effect. Intermediate precision was ≤3.2 % and repeatability was 1.4-2.5 % across all concentration levels. The relative mean bias was -0.3 to 3.5 %. Expanded measurement uncertainties for target value assignment (n=6) were found to be ≤2.9 % (k=2) independent of the concentration level and the nature of the sample. CONCLUSIONS: In human serum and plasma, the RMP demonstrated high analytical performance for topiramate quantification and fulfilled the requirements on measurement uncertainty. Traceability to SI units was established by qNMR content determination of the topiramate, which was used for direct calibration of the RMP. This RMP is, therefore, fit for purpose for routine assay standardization and clinical sample evaluation.


Assuntos
Plasma , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Topiramato , Espectrometria de Massas em Tandem/métodos , Técnicas de Diluição do Indicador , Anticonvulsivantes , Isótopos , Padrões de Referência
20.
Anal Bioanal Chem ; 415(23): 5637-5644, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37490154

RESUMO

We developed and evaluated two-level, namely 2017011 and 2017012, serum-based reference materials (RMs) for 17 beta-estradiol (17 ß-E2) by the reference method of isotope dilution liquid chromatography tandem mass spectrometry (ID-LC-MS/MS) from the remaining serum samples after routine clinical tests, to help improve clinical routine testing and provide the traceability of results. This paper describes the development process of these RMs. The National Metrology Institute of Japan (NMIJ) certified reference material (CRM) 6004-a was used as the primary RM for the measurement of 17 ß-E2. These serum-based RMs showed satisfactory homogeneity and stability. They also assessed the commutability between the reference method and the three routine clinical immunoassay systems. Besides, a collaborative study was carried out in five reference laboratories, all of which had been accredited by the China National Accreditation Service for Conformity Assessment (CNAS) in accordance with ISO/WD 15725-1. Statistical analysis of raw results and uncertainty assessment obtained certified values: 2017011 was 445.2 ± 39.0 pmol/L, and 2017012 was 761.9 ± 35.5 pmol/L.


Assuntos
Estradiol , Espectrometria de Massas em Tandem , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Técnicas de Diluição do Indicador , Isótopos , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...