Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.395
Filtrar
1.
Curr Oncol ; 31(6): 3546-3562, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38920744

RESUMO

BACKGROUND: Diagnostic blood tests have the potential to identify lung cancer in people at high risk. We assessed the cost-effectiveness of a lung cancer screening intervention, using the EarlyCDT®-Lung Test (ECLS) with subsequent X-ray and low-dose chest CT scans (LDCT) for patients with a positive test result, compared to both usual care and LDCT screening for the target population. METHODS: We conducted a model-based lifetime analysis from a UK NHS and personal social services perspective. We estimated incremental net monetary benefit (NMB) for the ECLS intervention compared to no screening and to LDCT screening. RESULTS: The incremental NMB of ECLS intervention compared to no screening was GBP 33,179 (95% CI: -GBP 81,396, GBP 147,180) and GBP 140,609 (95% CI: -GBP 36,255, GBP 316,612), respectively, for a cost-effectiveness threshold of GBP 20,000 and GBP 30,000 per quality-adjusted life year. The same figures compared with LDCT screening were GBP 162,095 (95% CI: GBP 52,698, GBP 271,735) and GBP 52,185 (95% CI: -GBP 115,152, GBP 219,711). CONCLUSIONS: The ECLS intervention is the most cost-effective screening alternative, with the highest probability of being cost-effective, when compared to no screening or LDCT screening. This result may change with modifications of the parameters, suggesting that the three alternatives considered in the main analysis are potentially cost-effective.


Assuntos
Análise Custo-Benefício , Detecção Precoce de Câncer , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico , Detecção Precoce de Câncer/economia , Detecção Precoce de Câncer/métodos , Escócia , Feminino , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/economia , Idoso , Testes Hematológicos/economia , Testes Hematológicos/métodos , Programas de Rastreamento/economia , Programas de Rastreamento/métodos
2.
Clin Lab ; 70(6)2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38868884

RESUMO

BACKGROUND: Reference intervals are essential for the interpretation of clinical laboratory tests and patient management. This study aims to determine age and gender reference intervals of complete blood count (CBC) in the Moroccan population by using the indirect approach. METHODS: The study used data of ostensibly healthy adults collected retrospectively using the laboratory information system (LIS) of the Laboratory for Research and Medical Analysis of the Fraternal Royal Gendarmerie in Rabat (Morocco), between January 2018 and February 2020. The study included 5,898 men and 10,172 women ranging in age from 18 to 90 years. The lower and upper reference limits of CBC parameters were calculated using the nonparametric technique, as suggested by the Clinical and Laboratory Standards Institute (CLSI). RESULTS: All hematological parameters showed no clinically significant gender-related differences, except small differences in the values of hemoglobin (HB), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH) and mean corpuscular hemoglobin concentration (MCHC). There were also no clinically significant agerelated differences for median values of all hematology analytes in both genders, except for platelet count (PLT) that continued to decline with increasing age in men and women, and Red blood cell count (RBC), Hematocrit (HCT), and hemoglobin (HB) that tended to increase with age but decrease in older age groups in men while they tended to increase with age in women. CONCLUSIONS: The indirect method can be used to establish reference intervals for CBC, with appropriate selection criteria and statistical tools. Our findings differed from the reference ranges provided in the textbook and also in other countries' reports.


Assuntos
Pacientes Ambulatoriais , Humanos , Adulto , Masculino , Feminino , Valores de Referência , Pessoa de Meia-Idade , Marrocos , Idoso , Adulto Jovem , Adolescente , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Contagem de Células Sanguíneas/normas , Contagem de Células Sanguíneas/estatística & dados numéricos , Pacientes Ambulatoriais/estatística & dados numéricos , Índices de Eritrócitos , Hemoglobinas/análise , Hematócrito , Fatores Etários , Fatores Sexuais , Testes Hematológicos/normas , Testes Hematológicos/métodos
3.
An Acad Bras Cienc ; 96(2): e20230894, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38922277

RESUMO

The need for the identification of risk factors associated to COVID-19 disease severity remains urgent. Patients' care and resource allocation can be potentially different and are defined based on the current classification of disease severity. This classification is based on the analysis of clinical parameters and routine blood tests, which are not standardized across the globe. Some laboratory test alterations have been associated to COVID-19 severity, although these data are conflicting partly due to the different methodologies used across different studies. This study aimed to construct and validate a disease severity prediction model using machine learning (ML). Seventy-two patients admitted to a Brazilian hospital and diagnosed with COVID-19 through RT-PCR and/or ELISA, and with varying degrees of disease severity, were included in the study. Their electronic medical records and the results from daily blood tests were used to develop a ML model to predict disease severity. Using the above data set, a combination of five laboratorial biomarkers was identified as accurate predictors of COVID-19 severe disease with a ROC-AUC of 0.80 ​±â€‹ 0.13. Those biomarkers included prothrombin activity, ferritin, serum iron, ATTP and monocytes. The application of the devised ML model may help rationalize clinical decision and care.


Assuntos
Biomarcadores , COVID-19 , Aprendizado de Máquina , SARS-CoV-2 , Índice de Gravidade de Doença , Humanos , COVID-19/sangue , COVID-19/diagnóstico , Feminino , Masculino , Biomarcadores/sangue , Pessoa de Meia-Idade , Prognóstico , Adulto , Ferritinas/sangue , Idoso , Brasil , Testes Hematológicos/métodos , Curva ROC , Fatores de Risco
6.
BMC Pediatr ; 24(1): 328, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38741033

RESUMO

BACKGROUND: The Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), influenza A, and respiratory syncytial virus (RSV) infections have similar modes of transmission and clinical symptoms. There is a need to identify simple diagnostic indicators to distinguish these three infections, particularly for community hospitals and low- and middle-income countries that lack nucleic acid detection kits. This study used clinical data to assess the diagnostic value of routine blood tests in differentiating between SARS-CoV-2, influenza A, and RSV infections in children. METHODS: A total of 1420 children treated at the Hangzhou Children's Hospital between December 2022 and June 2023 were enrolled in this study, of whom 351 had SARS-CoV-2, 671 had influenza, and 398 had RSV. In addition, 243 healthy children were also collected. The blood test results of SARS-CoV-2 patients were compared to those of patients with influenza A and RSV and the healthy controls. The area under the receiver operating characteristic curve (AUC-ROC) was employed to evaluate each blood parameter's diagnostic value. RESULTS: Children with SARS-CoV-2 exhibited notably elevated levels of white blood cell (WBC) count, platelet (PLT) count, neutrophil count, and neutrophil-to-lymphocyte ratio (NLR) compared to influenza A patients (P < 0.05). In contrast, SARS-CoV-2 patients exhibited a decrease in the mean platelet volume to platelet count ratio (MPV/PLT) and the lymphocyte-to-monocyte ratio (LMR) when compared to other individuals (P < 0.05). These parameters had an AUC between 0.5 and 0.7. Compared to patients with RSV, SARS-CoV-2 patients had significantly higher MPV/PLT and significantly lower WBC, lymphocyte, PLT, LMR, and lymphocyte multiplied by platelet (LYM*PLT) values (P < 0.05). However, only LYM*PLT had an acceptable diagnostic value above 0.7 for all age groups. Compared to healthy children, children with COVID-19 exhibited elevated NLR and MPV/PLT levels, alongside decreased lymphocyte, PLT, LMR, and LYM*PLT values. (P < 0.05). The AUC of the LMR, LYM*PLT, and PLT were above 0.7 in all age groups, indicating promising diagnostic values. CONCLUSIONS: The routine blood parameters among patients with COVID-19, influenza A, and RSV differ significantly early in the disease and could be used by clinicians to discriminate between the 3 types of infection.


Assuntos
COVID-19 , Influenza Humana , Infecções por Vírus Respiratório Sincicial , Humanos , COVID-19/diagnóstico , COVID-19/sangue , Estudos Retrospectivos , Influenza Humana/diagnóstico , Influenza Humana/sangue , Masculino , Feminino , Criança , Pré-Escolar , Infecções por Vírus Respiratório Sincicial/diagnóstico , Infecções por Vírus Respiratório Sincicial/sangue , Diagnóstico Diferencial , Lactente , Curva ROC , Adolescente , Testes Hematológicos/métodos , Criança Hospitalizada , SARS-CoV-2 , China
7.
Vox Sang ; 119(6): 556-562, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38523360

RESUMO

BACKGROUND AND OBJECTIVES: Malaria continues to be a significant public health concern in India, with several regions experiencing endemicity and sporadic outbreaks. The prevalence of malaria in blood donors, in India, varies between 0.02% and 0.07%. Common techniques to screen for malaria, in blood donors and patients, include microscopic smear examination and rapid diagnostic tests (RDTs) based on antigen detection. The aim of this study was to evaluate a new fully automated analyser, XN-31, for malaria detection, as compared with current practice of using RDT. MATERIALS AND METHODS: Cross-sectional analytical study was conducted to evaluate clinical sensitivity and specificity of new automated analyser XN-31 among blood donors' samples and clinical samples (patients with suspicion of malaria) from outpatient clinic collected over between July 2021 and October 2022. No additional sample was drawn from blood donor or patient. All blood donors and patients' samples were processed by malaria rapid diagnostic test, thick-smear microscopy (MIC) and the haematology analyser XN-31. Any donor blood unit incriminated for malaria was discarded. Laboratory diagnosis using MIC was considered the 'gold standard' in the present study. Clinical sensitivity and specificity of XN-31 were compared with the gold standard. RESULTS: Fife thousand and five donor samples and 82 diagnostic samples were evaluated. While the clinical sensitivity and specificity for donor samples were 100%, they were 72.7% and 100% for diagnostic samples. CONCLUSION: Automated haematology analysers represent a promising solution, as they can deliver speedy and sensitive donor malaria screening assessments. This method also has the potential to be used for pre-transfusion malaria screening along with haemoglobin estimation.


Assuntos
Doadores de Sangue , Malária , Humanos , Índia , Malária/diagnóstico , Malária/sangue , Estudos Transversais , Feminino , Masculino , Sensibilidade e Especificidade , Adulto , Testes Hematológicos/métodos , Testes Hematológicos/instrumentação
8.
Cir Esp (Engl Ed) ; 102(6): 300-306, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38342139

RESUMO

AIM: Accurate diagnosis of complicated appendicitis is of importance to ensure that patients receive early and effective treatment, minimizing the risk of postoperative complications to promote successful recovery. Biochemical markers are a promising tool to identify complicated appendicitis. We aimed to evaluate the potential role of novel parameters related with neutrophil activation, known as "Extended Inflammation Parameters" (EIP), included in blood cell count reported by Sysmex XN-Series analyzers, compared to other canonical biomarkers in identifying complicated appendicitis. METHOD: Prospective observational study including patients with confirmed diagnosis of acute appendicitis. C-reactive protein (CRP), procalcitonin, cell blood count, including white blood cell (WBC), absolute neutrophil (ANC) and immature granulocyte (IG) count and EIP (neutrophil reactivity [NEUT-RI] and granularity intensity [NEUT-GI]) were analyzed before surgery. Their accuracy to diagnose complicated appendicitis was tested in an ROC curve analysis. RESULTS: Our population study included 119 patients, and appendicitis was complicated in 58 (48.7%). NLR, CRP and procalcitonin levels, ANC and IG count and NEUT-RI and NEUT-GI were higher in patients with complicated appendicitis. Regarding accuracy for complicated appendicitis, CRP was the biomarker with the highest performance (ROC AUC: 0.829), with an optimal cutoff of 73.1 mg/L (sensitivity: 63.8%, specificity: 88.5%). NEUT-RI and NEUT-GI achieved both significant but poor accuracy, with ROC AUC of 0.606 and 0.637, respectively. CONCLUSIONS: Novel laboratory tests reported by Sysmex XN-Series analyzers have poor accuracy for identifying complicated appendicitis. In this study, CRP was the biomarker with the highest performance and may be useful as predictor of the severity of acute appendicitis.


Assuntos
Apendicite , Biomarcadores , Proteína C-Reativa , Ativação de Neutrófilo , Pró-Calcitonina , Apendicite/sangue , Apendicite/diagnóstico , Apendicite/cirurgia , Humanos , Estudos Prospectivos , Feminino , Masculino , Adulto , Proteína C-Reativa/análise , Pessoa de Meia-Idade , Biomarcadores/sangue , Pró-Calcitonina/sangue , Doença Aguda , Contagem de Leucócitos/métodos , Contagem de Leucócitos/instrumentação , Testes Hematológicos/métodos , Testes Hematológicos/instrumentação , Curva ROC , Idoso , Neutrófilos , Inflamação/sangue
11.
Environ Sci Technol ; 58(4): 1802-1812, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38217501

RESUMO

Humans interact with thousands of chemicals. This study aims to identify substances of emerging concern and in need of human health risk evaluations. Sixteen pooled human serum samples were constructed from 25 individual samples each from the National Institute of Environmental Health Sciences' Clinical Research Unit. Samples were analyzed using gas chromatography (GC) × GC/time-of-flight (TOF)-mass spectrometry (MS) in a suspect screening analysis, with follow-up confirmation analysis of 19 substances. A standard reference material blood sample was also analyzed through the confirmation process for comparison. The pools were stratified by sex (female and male) and by age (≤45 and >45). Publicly available information on potential exposure sources was aggregated to annotate presence in serum as either endogenous, food/nutrient, drug, commerce, or contaminant. Of the 544 unique substances tentatively identified by spectral matching, 472 were identified in females, while only 271 were identified in males. Surprisingly, 273 of the identified substances were found only in females. It is known that behavior and near-field environments can drive exposures, and this work demonstrates the existence of exposure sources uniquely relevant to females.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Testes Hematológicos , Feminino , Humanos , Masculino , Cromatografia Gasosa-Espectrometria de Massas/métodos , Testes Hematológicos/métodos , Adulto , Pessoa de Meia-Idade
12.
Clin Chim Acta ; 554: 117762, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38211807

RESUMO

BACKGROUND AND AIMS: The results of blood potassium can be seriously affected by specimen hemolysis which may interfere with clinicians' interpretation of test results. Redrawing blood and retesting may delay treatment time and it is not feasible for critically ill patients with difficulty in specimen collection. Therefore, it is significant to establish a mathematical model that can quickly correct the blood potassium concentration of hemolytic specimens. MATERIALS AND METHODS: The residual blood samples from 107 patients at Peking University Third Hospital were collected to establish potassium correction model. Samples with different hemolysis indexes were obtained by ultrasonic crushing method. Blood potassium correction models of hemolysis specimens were established by linear regression and curve fitting using SPSS and MATLAB, respectively. In addition, blood samples from another 85 patients were used to verify the accuracy of the models and determine the optimal model. RESULTS: Variation of potassium (ΔK) was 0.003HI-0.03 (R2 = 0.9749) in linear regression model which had high correlation in ΔK and HI, and the correction formula was Kcorrection = Khemolysis-0.003 × HI + 0.03. Average rate of potassium change (αaverage) was 0.003 ± 0.0002 mmol/L in curve fitting model, and correction formula was Kcorrection = Khemolysis-0.003 × HI, and both men and women can use the same correction model. The accuracy of linear regression model was 96.5 %, and there was statistical difference between the verification results and the measured values (p < 0.05), while the accuracy of curve fitting model was 100 %, and there was no statistical difference between the verification results and the measured values (p = 0.552). The model was validated in an independent set of samples and all were within the TEa of 6 % and the accuracy of 100 %. CONCLUSIONS: Both linear regression and curve fitting models of potassium correction had high accuracy, and can effectively correct the potassium concentration of hemolytic specimens, while the curve fitting model have superior accuracy.


Assuntos
Hemólise , Potássio , Humanos , Feminino , Testes Hematológicos/métodos , Manejo de Espécimes , Modelos Lineares
13.
Curr Cancer Drug Targets ; 24(5): 556-564, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38178672

RESUMO

BACKGROUND: Hepatocellular carcinoma (HCC) is the fourth leading cause of cancer death worldwide. Alpha-protein (AFP) is the most widely used blood biomarker for HCC. However, elevated serum AFP is only observed in part of HCC. AIMS: This study aimed to develop an efficient nomogram model to distinguish patients with alpha- protein-negative HCC and liver cirrhosis. OBJECTIVES: A total of 1130 patients (508 HCC patients + 622 cirrhosis patients) were enrolled in the training cohort. A total of 244 HCC patients and 246 cirrhosis patients were enrolled in the validation cohort. METHODS: A total of 41 parameters about blood tests were analyzed with logistic regression. The nomogram was based on independent factors and validated both internally and externally. RESULTS: Independent factors were eosinophils %, hemoglobin concentration distribution width, fibrinogen, platelet counts, total bile acid, and mitochondria aspartate aminotransferase. The calibration curve for the probability of HCC showed good agreement between prediction by nomogram and actual observation. The concordance index was 0.851. In the validation cohort, the nomogram distinguished HCC from liver cirrhosis with an area under the curve of receiver operating characteristic of 0.754. CONCLUSION: This proposed nomogram was an accurate and useful method to distinguish patients with AFP-negative HCC from liver cirrhosis.


Assuntos
Carcinoma Hepatocelular , Cirrose Hepática , Neoplasias Hepáticas , Nomogramas , alfa-Fetoproteínas , Humanos , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/sangue , Neoplasias Hepáticas/sangue , Neoplasias Hepáticas/diagnóstico , Feminino , Masculino , Pessoa de Meia-Idade , alfa-Fetoproteínas/análise , alfa-Fetoproteínas/metabolismo , Cirrose Hepática/sangue , Cirrose Hepática/diagnóstico , Idoso , Biomarcadores Tumorais/sangue , Testes Hematológicos/métodos , Curva ROC , Adulto
15.
BMC Oral Health ; 23(1): 473, 2023 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-37434176

RESUMO

BACKGROUND: The presence of comorbidities, especially those with a chronic inflammatory nature such as periodontitis, can facilitate COVID-19 progression toward more severe forms. Both of these diseases can affect systemic health and alter hematological test results. In this study, we decided to investigate COVID-19 and periodontitis' possible interaction with these alterations. METHODS: Hospitalized patients with a definitive diagnosis of COVID-19 were included. Controls had mild to moderate COVID-19, while cases had severe to critical COVID-19. Periodontal examination was done for each patient. Relevant medical and hematological data were extracted from patient's hospital files. RESULTS: A total of 122 patients entered the final analysis. The minimum white blood cell counts were associated with the severity of periodontitis. The interaction between periodontitis and COVID-19 was associated with increased minimum white blood cell counts and decreased platelet counts. COVID-19 severity was associated with increased venous oxygen saturation, prothrombin time, the maximum partial thromboplastin time, the maximum and average urea, the maximum creatinine, the maximum potassium, and lactate dehydrogenase, and decreased sodium levels. CONCLUSIONS: Results of this study showed that several blood parameters were associated with periodontitis, COVID-19, or the interaction between them.


Assuntos
COVID-19 , Periodontite , Humanos , COVID-19/diagnóstico , COVID-19/epidemiologia , Testes Hematológicos/métodos , Periodontite/epidemiologia , Inflamação , Comorbidade , Índice de Gravidade de Doença , Estudos de Casos e Controles , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais
16.
Analyst ; 148(13): 3036-3044, 2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37265396

RESUMO

Nucleic acid extraction (NAE) plays a crucial role for diagnostic testing procedures. For decades, dried blood spots (DBS) have been used for serology, drug monitoring, and molecular studies. However, extracting nucleic acids from DBS remains a significant challenge, especially when attempting to implement these applications to the point-of-care (POC). To address this issue, we have developed a paper-based NAE method using cellulose filter papers (DBSFP) that operates without the need for electricity (at room temperature). Our method allows for NAE in less than 7 min, and it involves grade 3 filter paper pre-treated with 8% (v/v) igepal surfactant, 1 min washing step with 1× PBS, and 5 min incubation at room temperature in 1× TE buffer. The performance of the methodology was assessed with loop-mediated isothermal amplification (LAMP), targeting the human reference gene beta-actin and the kelch 13 gene from P. falciparum. The developed method was evaluated against FTA cards and magnetic bead-based purification, using time-to-positive (min) for comparative analysis. Furthermore, we optimised our approach to take advantage of the dual functionality of the paper-based extraction, allowing for elution (eluted disk) as well as direct placement of the disk in the LAMP reaction (in situ disk). This flexibility extends to eukaryotic cells, bacterial cells, and viral particles. We successfully validated the method for RNA/DNA detection and demonstrated its compatibility with whole blood stored in anticoagulants. Additionally, we studied the compatibility of DBSFP with colorimetric and lateral flow detection, showcasing its potential for POC applications. Across various tested matrices, targets, and experimental conditions, our results were comparable to those obtained using gold standard methods, highlighting the versatility of our methodology. In summary, this manuscript presents a cost-effective solution for NAE from DBS, enabling molecular testing in virtually any POC setting. When combined with LAMP, our approach provides sample-to-result detection in under 35 minutes.


Assuntos
Testes Hematológicos , Sistemas Automatizados de Assistência Junto ao Leito , Ácidos Nucleicos/isolamento & purificação , Testes Hematológicos/métodos , Humanos , Actinas/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Malária Falciparum/diagnóstico , Colorimetria , Plasmodium falciparum/genética , Plasmodium falciparum/isolamento & purificação
17.
Analyst ; 148(9): 2021-2034, 2023 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-36970954

RESUMO

Blood analysis through complete blood count is the most basic medical test for disease diagnosis. Conventional blood analysis requires bulky and expensive laboratory facilities and skilled technicians, limiting the universal medical use of blood analysis outside well-equipped laboratory environments. Here, we propose a multiparameter mobile blood analyzer combined with label-free contrast-enhanced defocusing imaging (CEDI) and machine vision for instant and on-site diagnostic applications. We designed a low-cost and high-resolution miniature microscope (size: 105 mm × 77 mm × 64 mm, weight: 314 g) that comprises a pair of miniature aspheric lenses and a 415 nm LED for blood image acquisition. The analyzer, adopting CEDI, can obtain both the refractive index distributions of the white blood cell (WBC) and hemoglobin spectrophotometric information, enabling the analyzer to supply rich blood parameters, including the five-part WBC differential count, red blood cell (RBC) count, and mean corpuscular hemoglobin (MCH) quantification with machine vision algorithms and the Lambert-Beer law. We have shown that our assay can analyze a blood sample within 10 minutes without complex staining, and measurements (30 samples) from the analyzer have a strong linear correlation with clinical reference values (significance level of 0.0001). This study provides a miniature, light weight, low-cost, and easy-to-use blood analysis technique that overcomes the challenge of simultaneously realizing FWD count, RBC count, and MCH analysis using a mobile device and has great potential for integrated surveillance of various epidemic diseases, including coronavirus infection, invermination, and anemia, especially in low- and middle-income countries.


Assuntos
Testes Hematológicos , Hemoglobinas , Contagem de Células Sanguíneas/métodos , Testes Hematológicos/métodos , Contagem de Eritrócitos/métodos , Contagem de Leucócitos , Hemoglobinas/análise
18.
Scand J Clin Lab Invest ; 83(1): 18-22, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36534489

RESUMO

Hb variants prevalent in China are different from those in other countries. We aimed to assess the interference from Hb variants found in China on HbA1c measurement. All Hb variants were confirmed using Sanger sequencing. HbA1c was measured using a capillary electrophoresis method (Capillarys 3 OCTA), two cation-exchange high-performance liquid chromatography methods (ADAMS HA-8180V and HLC-723 G8 standard mode), an immunoassay (Cobas c501), and a boronate affinity chromatography method (Premier Hb9210). Premier Hb9210 was used as a comparative method. A total of 16 species of Hb variants were identified in 102 variant carriers. The most common variant was Hb E, followed by Hb Q-Thailand, Hb New York and Hb J-Bangkok. Clinically significant interference was observed for the Capillarys 3 OCTA (two Hb variants), ADAMS HA-8180V (seven Hb variants), HLC-723 G8 (14 Hb variants), and Cobas c501 (two Hb variants). The proportion of unacceptable HbA1c results was 13.7% for Capillarys 3 OCTA, 52.9% for HA-8180V, 83.3% for HLC-723 G8, and 3.9% for Cobas c501. Hb variants in China severely affect the accuracy of some commonly used HbA1c methods.


Assuntos
Testes Hematológicos , Hemoglobinas Anormais , Humanos , Cromatografia Líquida de Alta Pressão/métodos , Eletroforese Capilar , Hemoglobinas Glicadas/genética , Testes Hematológicos/métodos , Hemoglobinas Anormais/genética , Hemoglobinas Anormais/análise
20.
Biosensors (Basel) ; 12(7)2022 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-35884246

RESUMO

This article first reviews scientific meanings of single-cell analysis by highlighting two key scientific problems: landscape reconstruction of cellular identities during dynamic immune processes and mechanisms of tumor origin and evolution. Secondly, the article reviews clinical demands of single-cell analysis, which are complete blood counting enabled by optoelectronic flow cytometry and diagnosis of hematologic malignancies enabled by multicolor fluorescent flow cytometry. Then, this article focuses on the developments of optoelectronic flow cytometry for the complete blood counting by comparing conventional counterparts of hematology analyzers (e.g., DxH 900 of Beckman Coulter, XN-1000 of Sysmex, ADVIA 2120i of Siemens, and CELL-DYN Ruby of Abbott) and microfluidic counterparts (e.g., microfluidic impedance and imaging flow cytometry). Future directions of optoelectronic flow cytometry are indicated where intrinsic rather than dependent biophysical parameters of blood cells must be measured, and they can replace blood smears as the gold standard of blood analysis in the near future.


Assuntos
Testes Hematológicos , Microfluídica , Contagem de Células Sanguíneas , Citometria de Fluxo , Testes Hematológicos/métodos , Análise de Célula Única
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...