Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.093
Filtrar
1.
Cell Mol Life Sci ; 81(1): 267, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38884678

RESUMO

Neutralizing antibodies are considered a correlate of protection against severe human respiratory syncytial virus (HRSV) disease. Currently, HRSV neutralization assays are performed on immortalized cell lines like Vero or A549 cells. It is known that assays on these cell lines exclusively detect neutralizing antibodies (nAbs) directed to the fusion (F) protein. For the detection of nAbs directed to the glycoprotein (G), ciliated epithelial cells expressing the cellular receptor CX3CR1 are required, but generation of primary cell cultures is expensive and labor-intensive. Here, we developed a high-throughput neutralization assay based on the interaction between clinically relevant HRSV grown on primary cells with ciliated epithelial cells, and validated this assay using a panel of infant sera. To develop the high-throughput neutralization assay, we established a culture of differentiated apical-out airway organoids (Ap-O AO). CX3CR1 expression was confirmed, and both F- and G-specific monoclonal antibodies neutralized HRSV in the Ap-O AO. In a side-by-side neutralization assay on Vero cells and Ap-O AO, neutralizing antibody levels in sera from 125 infants correlated well, although titers on Ap-O AO were consistently lower. We speculate that these lower titers might be an actual reflection of the neutralizing antibody capacity in vivo. The organoid-based neutralization assay described here holds promise for further characterization of correlates of protection against HRSV disease.


Assuntos
Anticorpos Neutralizantes , Receptor 1 de Quimiocina CX3C , Testes de Neutralização , Organoides , Infecções por Vírus Respiratório Sincicial , Vírus Sincicial Respiratório Humano , Humanos , Vírus Sincicial Respiratório Humano/imunologia , Anticorpos Neutralizantes/imunologia , Organoides/metabolismo , Organoides/imunologia , Organoides/virologia , Organoides/citologia , Animais , Testes de Neutralização/métodos , Chlorocebus aethiops , Células Vero , Infecções por Vírus Respiratório Sincicial/imunologia , Infecções por Vírus Respiratório Sincicial/virologia , Receptor 1 de Quimiocina CX3C/metabolismo , Receptor 1 de Quimiocina CX3C/imunologia , Anticorpos Antivirais/imunologia , Proteínas Virais de Fusão/imunologia , Proteínas Virais de Fusão/metabolismo , Lactente , Células Epiteliais/metabolismo , Células Epiteliais/imunologia , Células Epiteliais/virologia , Anticorpos Monoclonais/imunologia
2.
J Virol Methods ; 328: 114959, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38788979

RESUMO

In Foot-and-mouth disease (FMD) enzootic countries, periodic vaccination is the key tool in controlling the disease incidence. Active seromonitoring of the vaccinated population is critical to assess the impact of vaccination. Virus neutralization test (VNT) and enzyme-linked immunosorbent assays (ELISA) are commonly used for antibody detection. Assays like liquid phase blocking ELISA (LPBE) or solid phase competition ELISA (SPCE) are preferred as they do not require handling of live FMDV and are routinely used for seromonitoring or for vaccine potency testing; however, false positives are high in LPBE. Here we report, a monoclonal antibody (mAb) based SPCE as a potential alternate assay for antibody titration. From a panel of 12 mAbs against FMDV serotype A, two mAbs were chosen for the development of SPCE. Based on a set of 453 sera, it was demonstrated that mAb 2C4G11, mAb 6E8D11and polyclonal antibody (pAb) based SPCE had a relative sensitivity of 86.1, 86.1 and 80.3 %; and specificity of 99.6, 99.1 and 99.1 %, respectively. The correlation, repeatability, and level of agreement of the assays were high demonstrating the potential use of mAb in large scale surveillance studies and regular vaccine potency testing.


Assuntos
Anticorpos Monoclonais , Anticorpos Antivirais , Ensaio de Imunoadsorção Enzimática , Vírus da Febre Aftosa , Febre Aftosa , Sensibilidade e Especificidade , Sorogrupo , Ensaio de Imunoadsorção Enzimática/métodos , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Vírus da Febre Aftosa/imunologia , Animais , Anticorpos Monoclonais/imunologia , Febre Aftosa/diagnóstico , Febre Aftosa/imunologia , Febre Aftosa/virologia , Bovinos , Testes de Neutralização/métodos
3.
Methods Mol Biol ; 2808: 209-224, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38743373

RESUMO

The plaque reduction neutralization test (PRNT) and the enzyme-linked immunosorbent assay (ELISA) are both widely used to assess immunity to infectious diseases such as measles, but they use two different measurement principles: ELISA measures the ability of antibodies to bind to virus components, while the PRNT detects the aptitude of antibodies to prevent the infection of a susceptible cell. As a result, detection of measles virus (MV) neutralizing antibodies is the gold standard for assessing immunity to measles. However, the assay is laborious and requires experience and excellent technical skills. In addition, the result is only available after several days. Therefore, the classical PRNT is not suitable for high-throughput testing. By using an immunocolorimetric assay (ICA) to detect MV-infected cells, the standard PRNT has been developed into a focus reduction neutralization test (FRNT). This assay is faster and has improved specificity. The FRNT described here is extremely useful when immunity to measles virus needs to be assessed in patients with a specific medical condition, such as immunocompromised individuals in whom presumed residual immunity needs to be assessed. The FRNT is not generally recommended for use with large numbers of specimens, such as in a seroprevalence study.


Assuntos
Anticorpos Neutralizantes , Anticorpos Antivirais , Vírus do Sarampo , Sarampo , Testes de Neutralização , Testes de Neutralização/métodos , Vírus do Sarampo/imunologia , Sarampo/imunologia , Sarampo/diagnóstico , Sarampo/virologia , Humanos , Anticorpos Neutralizantes/imunologia , Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/imunologia , Chlorocebus aethiops , Animais , Células Vero , Ensaio de Placa Viral/métodos , Ensaio de Imunoadsorção Enzimática/métodos
4.
Front Cell Infect Microbiol ; 14: 1341332, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38746783

RESUMO

Introduction: The Crimean-Congo hemorrhagic fever virus (CCHFV), the most geographically widespread tick-borne virus, is endemic in Africa, Eastern Europe and Asia, with infection resulting in mortality in up to 30% of cases. Currently, there are no approved vaccines or effective therapies available for CCHF. The CCHFV should only be manipulated in the BSL-4 laboratory, which has severely hampered basic seroprevalence studies. Methods: In the present study, two antibody detection methods in the forms of an enzyme-linked immunosorbent assay (ELISA) and a surrogate virus neutralization test (sPVNT) were developed using a recombinant glycoprotein (rGP) and a vesicular stomatitis virus (VSV)-based virus bearing the CCHFV recombinant glycoprotein (rVSV/CCHFV) in a biosafety level 2 (BSL-2) laboratory, respectively. Results: The rGP-based ELISA and rVSV/CCHFV-based sVNT were established by using the anti-CCHFV pre-GC mAb 11E7, known as a broadly cross-reactive, potently neutralizing antibody, and their applications as diagnostic antigens were validated for the specific detection of CCHFV IgG and neutralizing antibodies in experimental animals. In two tests, mAb clone 11E7 (diluted at 1:163840 or 512) still displayed positive binding and neutralization, and the presence of antibodies (IgG and neutralizing) against the rGP and rVSV/CCHFV was also determined in the sera from the experimental animals. Both mAb 11E7 and animal sera showed a high reactivity to both antigens, indicating that bacterially expressed rGP and rVSV/CCHFV have good immunoreactivity. Apart from establishing two serological testing methods, their results also demonstrated an imperfect correlation between IgG and neutralizing antibodies. Discussion: Within this limited number of samples, the rGP and rVSV/CCHFV could be safe and convenient tools with significant potential for research on specific antibodies and serological samples.


Assuntos
Anticorpos Neutralizantes , Anticorpos Antivirais , Ensaio de Imunoadsorção Enzimática , Vírus da Febre Hemorrágica da Crimeia-Congo , Febre Hemorrágica da Crimeia , Imunoglobulina G , Testes de Neutralização , Vírus da Febre Hemorrágica da Crimeia-Congo/imunologia , Anticorpos Neutralizantes/sangue , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Testes de Neutralização/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Febre Hemorrágica da Crimeia/diagnóstico , Febre Hemorrágica da Crimeia/imunologia , Animais , Humanos , Glicoproteínas/imunologia , Testes Sorológicos/métodos , Proteínas Recombinantes/imunologia , Camundongos , Anticorpos Monoclonais/imunologia
5.
Med Microbiol Immunol ; 213(1): 6, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38722338

RESUMO

To date, there is no licensed vaccine for Middle East respiratory syndrome coronavirus (MERS-CoV). Therefore, MERS-CoV is one of the diseases targeted by the Coalition for Epidemic Preparedness Innovations (CEPI) vaccine development programs and has been classified as a priority disease by the World Health Organization (WHO). An important measure of vaccine immunogenicity and antibody functionality is the detection of virus-neutralizing antibodies. We have developed and optimized a microneutralization assay (MNA) using authentic MERS-CoV and standardized automatic counting of virus foci. Compared to our standard virus neutralization assay, the MNA showed improved sensitivity when analyzing 30 human sera with good correlation of results (Spearman's correlation coefficient r = 0.8917, p value < 0.0001). It is important to use standardized materials, such as the WHO international standard (IS) for anti-MERS-CoV immunoglobulin G, to compare the results from clinical trials worldwide. Therefore, in addition to the neutralizing titers (NT50 = 1384, NT80 = 384), we determined the IC50 and IC80 of WHO IS in our MNA to be 0.67 IU/ml and 2.6 IU/ml, respectively. Overall, the established MNA is well suited to reliably quantify vaccine-induced neutralizing antibodies with high sensitivity.


Assuntos
Anticorpos Neutralizantes , Anticorpos Antivirais , Coronavírus da Síndrome Respiratória do Oriente Médio , Testes de Neutralização , Coronavírus da Síndrome Respiratória do Oriente Médio/imunologia , Humanos , Testes de Neutralização/métodos , Anticorpos Neutralizantes/sangue , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/sangue , Infecções por Coronavirus/prevenção & controle , Infecções por Coronavirus/imunologia , Infecções por Coronavirus/diagnóstico , Animais , Concentração Inibidora 50 , Sensibilidade e Especificidade
6.
Cytometry A ; 105(6): 446-457, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38624015

RESUMO

The COVID-19 pandemic caused by the SARS-CoV-2 virus has highlighted the need for serological assays that can accurately evaluate the neutralizing efficiency of antibodies produced during infection or induced by vaccines. However, conventional assays often require the manipulation of live viruses on a level-three biosafety (BSL3) facility, which presents practical and safety challenges. Here, we present a novel, alternative assay that measures neutralizing antibodies (NAbs) against SARS-CoV-2 in plasma using flow cytometry. This assay is based on antibody binding to the S protein and has demonstrated precision in both intra- and inter-assay measurements at a dilution of 1:50. The cut-off was determined using Receiver Operating Characteristic (ROC) analysis and the value of 36.01% has shown high sensitivity and specificity in distinguishing between pre-pandemic sera, COVID-19 patients, and vaccinated individuals. The efficiency significantly correlates with the gold standard test, PRNT. Our new assay offers a safe and efficient alternative to conventional assays for evaluating NAbs against SARS-CoV-2.


Assuntos
Anticorpos Neutralizantes , Anticorpos Antivirais , COVID-19 , Citometria de Fluxo , SARS-CoV-2 , Humanos , Citometria de Fluxo/métodos , SARS-CoV-2/imunologia , Anticorpos Neutralizantes/imunologia , Anticorpos Neutralizantes/sangue , COVID-19/imunologia , COVID-19/diagnóstico , COVID-19/virologia , Anticorpos Antivirais/imunologia , Anticorpos Antivirais/sangue , Glicoproteína da Espícula de Coronavírus/imunologia , Testes de Neutralização/métodos , Teste Sorológico para COVID-19/métodos , Sensibilidade e Especificidade , Masculino , Feminino
7.
Hum Vaccin Immunother ; 20(1): 2330168, 2024 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-38567541

RESUMO

Human papillomavirus (HPV) vaccines, primarily relying on neutralizing antibodies, have proven highly effective. Recently, HPV-specific antibodies have been detected in the female genital tract secretions captured by first-void urine (FVU), offering a minimally invasive diagnostic approach. In this study, we investigated whether HPV16-specific antibodies present in FVU samples retain their neutralizing capacity by using pseudovirion-based neutralization assays. Paired FVU and serum samples (vaccinated n = 25, unvaccinated n = 25, aged 18-25) were analyzed using two orthogonal pseudovirion-based neutralization assays, one using fluorescence microscopy and the other using luminescence-based spectrophotometry. Results were compared with HPV16-specific IgG concentrations and correlations between neutralizing antibodies in FVU and serum were explored. The study demonstrated the presence of neutralizing antibodies in FVU using both pseudovirion-based neutralization assays, with the luminescence-based assay showing higher sensitivity for FVU samples, while the fluorescence microscopy-based assay exhibited better specificity for serum and overall higher reproducibility. High Spearman correlation values were calculated between HPV16-IgG and HPV16-neutralizing antibodies for both protocols (rs: 0.54-0.94, p < .001). Significant Spearman correlations between FVU and serum concentrations were also established for all assays (rs: 0.44-0.91, p < .01). This study demonstrates the continued neutralizing ability of antibodies captured with FVU, supporting the hypothesis that HPV vaccination may reduce autoinoculation and transmission risk to the sexual partner. Although further protocol optimizations are warranted, these findings provide a foundation for future research and larger cohort studies that could have implications for the optimal design, evaluation, and implementation of HPV vaccination programs.


Assuntos
Infecções por Papillomavirus , Vacinas contra Papillomavirus , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , Infecções por Papillomavirus/prevenção & controle , Reprodutibilidade dos Testes , Anticorpos Antivirais , Anticorpos Neutralizantes , Testes de Neutralização/métodos , Genitália Feminina , Papillomavirus Humano 16 , Imunoglobulina G
8.
J Virol Methods ; 327: 114945, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38649070

RESUMO

As variants of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continue to emerge, assessment of vaccine immunogenicity remains a critical factor to support continued vaccination. To this end, an in vitro microneutralization (MN50) assay was validated to quantitate SARS-CoV-2 neutralizing antibodies against prototype and variant strains (Beta, Delta, Omicron BA.1, Omicron BA.5, and XBB.1.5) in human serum. For the prototype strain, the MN50 assay met acceptance criteria for inter-/intra-assay precision, specificity, linearity, and selectivity. The assay was robust against changes to virus/serum incubation time, cell seeding density, virus content per well, cell passage number, and serum interference. Analyte in serum samples was stable up to five freeze/thaw cycles and for up to 12 months of storage at -80 ± 10 °C. Similar results were observed for the variant-adapted MN50 assays. The conversion factor to convert assay result units to WHO international standard units (IU/mL) was determined to be 0.62 for the prototype strain. This MN50 assay will be useful for vaccine immunogenicity analyses in clinical trial samples, enabling assessment of vaccine immunogenicity for ancestral and variant strains as variant-adapted vaccines are developed.


Assuntos
Anticorpos Neutralizantes , Anticorpos Antivirais , Vacinas contra COVID-19 , COVID-19 , Imunogenicidade da Vacina , Testes de Neutralização , SARS-CoV-2 , Humanos , Anticorpos Neutralizantes/sangue , Anticorpos Neutralizantes/imunologia , SARS-CoV-2/imunologia , SARS-CoV-2/genética , Testes de Neutralização/métodos , Anticorpos Antivirais/sangue , Vacinas contra COVID-19/imunologia , COVID-19/prevenção & controle , COVID-19/imunologia , COVID-19/diagnóstico , Sensibilidade e Especificidade , Animais , Reprodutibilidade dos Testes
9.
Sci Rep ; 14(1): 1421, 2024 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-38228735

RESUMO

Diagnosis of SARS-CoV-2 virus is mainly based on direct detection. Determination of specific antibodies has been used mostly for epidemiological reasons. However, select immunoassays showed good correlation to plaque reduction virus neutralization test (PRNT) in smaller patient cohorts, which suggests their potential as predictors of virus neutralization titer. A total of 3,699 samples from Covid-19 patients were included in the multicentric study performed in the Czech Republic. Anti-SARS-CoV-2 antibody levels were evaluated by 8 commercial antibody assays. Simultaneously, PRNT evaluations were performed with the SARS-CoV-2 B.1.258 variant. All immunoassays showed an overall high true positive diagnostic value ranging from 79.17 to 98.04%. Several commercial EIA methods showed highly positive correlation between the assay results and PRNT levels, e.g., Liaison CoV-2 TrimericS IgG DiaSorin (Spearman r = 0.8833; Architect SASRS-CoV-2 IgG Abbott (r = 0.7298); NovaLisa SARS-CoV-2 IgG NovaTec (r = 0.7103) and Anti-SARS-CoV-2 ELISA IgG Euroimmun (r = 0.7094). While this correlation was less positive for other assays, those, conversely, presented higher true positive values. For most immunoassays, the positive percent agreement of the results was ≥ 95% in sera exhibiting PRNT levels of 1:80 and higher. The assays tested have shown variable correlation to PRNT. Those possessing high positive predictive values serve well as qualitative tests, while others can be utilised as quantitative tests highly predictive of neutralization antibody levels.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Testes Sorológicos/métodos , Sensibilidade e Especificidade , Anticorpos Antivirais , Imunoglobulina G , Testes de Neutralização/métodos , Anticorpos Neutralizantes
10.
J Immunol Methods ; 523: 113585, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37949349

RESUMO

In this study, a proficiency panel was created for evaluation of assay performance and inter- and intra-laboratory assay comparisons, especially the ability to accurately measure negative, low, intermediate, and high levels of HPV type-specific antibodies. Comprised of 80 deidentified samples, this panel is designed for individual labs to evaluate assay performance characteristics on a biennial basis, to promote standardization of methodology and harmonization of data from human papillomavirus (HPV) serology tests in vaccine trials. The proficiency panel was qualified using 2 types of assays (singleplex Enzyme-Linked Immunosorbent Assays [ELISAs] or Multiplex antibody-binding assays and Pseudovirion-based neutralization assays [PBNAs]) in 10 laboratories from 7 countries, monitoring HPV antibody responses for up to 9 HPV types and using 3 different analysis methods. Sensitivity, specificity, and correlations (concordance, accuracy, and precision) were evaluated for each HPV type. In laboratories that tested all 80 samples, results from most (74/80) samples were reported with 100% accuracy across all 9 HPV types. The average sensitivity and specificity for singleplex and multiplex antibody binding assays ranged from 86.7% to 98.3% (sensitivity) and 84.2% to 94.3% (specificity), while the average sensitivity and specificity for the Pseudovirion (PsV)-based neutralization assays (PBNA) ranged from 87.6% to 99.4% (sensitivity) and 52.4% to 94.4% (specificity). This proficiency panel will help with assessing performance characteristics of HPV serology assays used in clinical trial studies and assure the data generated from these assays is harmonized.


Assuntos
Infecções por Papillomavirus , Vacinas contra Papillomavirus , Vacinas , Humanos , Testes de Neutralização/métodos , Formação de Anticorpos , Infecções por Papillomavirus/diagnóstico , Infecções por Papillomavirus/prevenção & controle , Anticorpos Antivirais
11.
J Virol Methods ; 322: 114828, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37778536

RESUMO

The conventional method for screening neutralizing antibodies to human enterovirus A71 (EVA71) (microneutralization assay) is time consuming and requires an expert to perform manual evaluation. An automated neutralization assay could shorten the testing time, improve reproducibility, and provide automatic analysis. This study aimed to develop a high-throughput flow cytometric neutralization assay to screen for EVA71 neutralizing antibodies, and to develop quality control materials to ensure accurate testing. The results of this study demonstrate the high potential viability of the proposed flow cytometric method. Compared to the standard method, the flow cytometric method was shown to require a smaller sample volume, provide a much faster turnaround time, provide a rapid result for interpreting the neutralizing antibody level, and allow for possible quantification of results. The observed drawbacks of the proposed method include higher cost per test, longer hands-on time, and lower sensitivity in low titer conditions, which could lead to false negative results. The developed quality control materials were demonstrated to be effective and storable for 1 month. These results pave the way for the optimization and implementation of an automated neutralization assay to screen for neutralizing antibodies not only against EVA71, but also against other viruses in the enterovirus genus.


Assuntos
Enterovirus Humano A , Infecções por Enterovirus , Enterovirus , Humanos , Anticorpos Neutralizantes , Reprodutibilidade dos Testes , Testes de Neutralização/métodos , Anticorpos Antivirais , Antígenos Virais
12.
Emerg Microbes Infect ; 12(2): e2261566, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37727107

RESUMO

ABSTRACTThe global outbreak of COVID-19 has caused a severe threat to human health; therefore, simple, high-throughput neutralization assays are desirable for developing vaccines and drugs against COVID-19. In this study, a high-titre SARS-CoV-2 pseudovirus was successfully packaged by truncating the C-terminus of the SARS-CoV-2 spike protein by 21 amino acids and infecting 293 T cells that had been stably transfected with the angiotensin-converting enzyme 2 (ACE2) receptor and furin (named AF cells), to establish a simple, high-throughput, and automated 384-well plate neutralization assay. The method was optimized for cell amount, virus inoculation, incubation time, and detection time. The automated assay showed good sensitivity, accuracy, reproducibility, Z' factor, and a good correlation with the live virus neutralization assay. The high-throughput approach would make it available for the SARS-CoV-2 neutralization test in large-scale clinical trials and seroepidemiological surveys which would aid the accelerated vaccine development and evaluation.


Assuntos
COVID-19 , Estomatite Vesicular , Animais , Humanos , SARS-CoV-2/genética , Anticorpos Neutralizantes , Reprodutibilidade dos Testes , Pseudotipagem Viral , Anticorpos Antivirais , Glicoproteína da Espícula de Coronavírus , Vírus da Estomatite Vesicular Indiana/genética , Testes de Neutralização/métodos
13.
J Immunol Methods ; 522: 113568, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37748728

RESUMO

Although it is considered the reference for quantification of neutralizing antibodies, classical method of the plaque reduction neutralization test (PRNT) is labor intensive, requires specific equipment and inputs, besides a long time for its finalization, even in the micro-PRNT version (in 96-well plates). It has a higher sample throughput, however the smaller wells make the reading of plaques more difficult. With an immunoenzymatic revelation step and a semi-automated reading, the µFRN-HRP (micro Focus Reduction Neutralization - Horseradish Peroxidase) is a faster and more efficient test for the quantification of YF neutralizing antibodies. This study aimed to standardize, validate, and compare it with the reference method in 6-well plates (PRNT). Once the execution protocol was standardized, precision, accuracy, selectivity, and robustness were evaluated to validate the µFRN-HRP. In addition, 200 sera of vaccinees were processed by the µFRN-HRP and by the micro-PRNT to compare with the reference test, estimating agreement by Intraclass Correlation Coefficient (ICC). The standardization and validation of the µFRN-HRP was carried out successfully. Weak to moderate agreement was observed between µFRN-HRP and PRNT for titers in reciprocal dilution, while the same comparison between the classical tests resulted in a better ICC. However, titers in milli-international units obtained by µFRN-HRP showed a substantial agreement with PRNT, while the agreement between micro-PRNT and PRNT was inferior. Therefore, µFRN-HRP can be used in the confirmation of natural YF infection and immune response to vaccination, replacing the micro-PRNT, gaining agility, while preserving the specificity of the result.


Assuntos
Anticorpos Neutralizantes , Febre Amarela , Humanos , Testes de Neutralização/métodos , Anticorpos Antivirais , Padrões de Referência
14.
Int J Mol Sci ; 24(15)2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37569707

RESUMO

COVID-19 is an ongoing, global pandemic caused by the novel, highly infectious SARS-CoV-2 virus. Efforts to mitigate the effects of SARS-CoV-2, such as mass vaccination and development of monoclonal therapeutics, require precise measurements of correlative, functional neutralizing antibodies that block virus infection. The development of rapid, safe, and easy-to-use neutralization assays is essential for faster diagnosis and treatment. Here, we developed a vesicular stomatitis virus (VSV)-based neutralization assay with two readout methods, imaging and flow cytometry, that were capable of quantifying varying degrees of neutralization in patient serum samples. We tested two different spike-pseudoviruses and conducted a time-course assay at multiple multiplicities of infection (MOIs) to optimize the assay workflow. The results of this assay correlate with the results of previously developed serology and surrogate neutralization assays. The two pseudovirus readout methods produced similar values of 50% neutralization titer values. Harvest-free in situ readouts for live-cell imaging and high-throughput analysis results for flow cytometry can provide unique capabilities for fast evaluation of neutralization, which is critical for the mitigation of future pandemics.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Citometria de Fluxo , Anticorpos Antivirais , Testes de Neutralização/métodos , Anticorpos Neutralizantes
15.
J Med Microbiol ; 72(6)2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37338005

RESUMO

Introduction. Diphtheria is a potentially life-threatening infection and remains endemic in many low- and middle-income countries (LMICs). A reliable, low-cost method for serosurveys in LMICs is warranted to estimate the accurate population immunity to control diphtheria.Hypothesis/Gap Statement. The correlation between the ELISA results against diphtheria toxoid and the gold standard diphtheria toxin neutralization test (TNT) values is poor when ELISA values are <0.1 IU ml-1, which results in inaccurate estimates of susceptibility in populations when ELISA is used for measuring antibody levels.Aim. To explore methods to accurately predict population immunity and TNT-derived anti-toxin titres from ELISA anti-toxoid results.Methodology. A total of 96 paired serum and dried blood spot (DBS) samples collected in Vietnam were used for comparison of TNT and ELISA. The diagnostic accuracy of ELISA measurement with reference to TNT was assessed by area under the receiver operating characteristic (ROC) curve (AUC) and other parameters. Optimal ELISA cut-off values corresponding to TNT cut-off values of 0.01 and 0.1 IU ml-1 were identified by ROC analysis. A method based on the multiple imputation approach was also applied to estimate TNT measurements in a dataset that only included ELISA results. These two approaches were then applied to ELISA results previously generated from 510 subjects in a serosurvey in Vietnam.Results. The ELISA results on DBS samples showed a good diagnostic performance compared to TNT. The cut-off values for ELISA measurement corresponding to the TNT cut-off values of 0.01 IU ml-1 were 0.060 IU ml-1 in serum samples, and 0.044 IU ml-1 in DBS samples. When a cut-off value of 0.06 IU ml-1 was applied to the 510 subject serosurvey data, 54 % of the population were considered susceptible (<0.01 IU ml-1). The multiple imputation-based approach estimated that 35 % of the population were susceptible. These proportions were much larger than the susceptible proportion estimated by the original ELISA measurements.Conclusion. Testing a subset of sera by TNT combined with ROC analysis or a multiple imputation approach helps to adjust ELISA thresholds or values to assess population susceptibility more accurately. DBS is an effective low-cost alternative to serum for future serological studies for diphtheria.


Assuntos
Toxina Diftérica , Difteria , Humanos , Difteria/diagnóstico , Testes de Neutralização/métodos , Testes Sorológicos , Ensaio de Imunoadsorção Enzimática/métodos
16.
J Virol Methods ; 319: 114769, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37391076

RESUMO

Rabies virus (RABV) causes a fatal encephalitis that can be prevented through timely vaccination. The levels of virus neutralising antibodies against rabies virus induced by vaccination can be measured using the fluorescent antibody virus neutralisation (FAVN) test. Following incubation of live virus with sera, this method involves the fixation of cell monolayers and staining of rabies virus-specific antigen using fluorescein isothiocyanate (FITC) -conjugated antibody to enable visualisation of rabies virus antigen using a fluorescence microscope. To simplify this procedure, a fluorescent recombinant rabies virus was constructed using reverse genetics by inserting the gene for the mCherry fluorescent protein in front of the ribonucleoprotein gene of the SAD B-19 genome and replacing its glycoprotein with that of the Challenge Virus Standard (CVS)-11 RABV strain to ensure antigenic authenticity with the FAVN. This new recombinant virus (termed mCCCG) expressed the mCherry protein to high levels enabling direct observation of infected cells. In vitro growth kinetics of mCCCG were indistinguishable from that of CVS-11. The stability of the recombinant virus was assessed by sequencing several passages of the rescued virus and only minor changes were detected. Comparative assessment of the virus neutralisation test using mCherry producing virus (NTmCV) against the FAVN demonstrated that test results were equivalent to each other; therefore, mCCCG can be used as an alternative to CVS-11 for measuring antibody titres against the rabies virus. The use of NTmCV removes the need for expensive antibody conjugates and significantly reduces assay time. This would be particularly beneficial for RABV serological assessment in resource limited settings. Moreover, the reading of the plates can be automatically using a cell imaging reader.


Assuntos
Vacina Antirrábica , Vírus da Raiva , Raiva , Humanos , Vírus da Raiva/genética , Anticorpos Antivirais , Testes de Neutralização/métodos , Antígenos Virais , Anticorpos Neutralizantes
17.
Biologicals ; 82: 101681, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37130447

RESUMO

For a long time, a widely used method for tetanus toxoid (Ttd) potency has been the challenge test, in which animals are immunized and then challenged with tetanus toxin in lethal or non-lethal way. In the context of animal welfare, an alternative is desired because the method causes unsustainable distress to animals. We aimed to replace the system for describing test results, in which scores are assigned to symptoms exhibited by challenged animals, with scores assigned to antibody ELISA titers in immunized mouse sera. The potency values and confidence intervals calculated by the absorbance score system were equivalent to those calculated by the symptom score system. We also attempted to utilize the raw ELISA absorbance instead of the assigned absorbance score and obtained similar results. ELISA may serve as an alternative to the lethal challenge for Ttd potency tests, not only in Japan but also in other countries in which mouse challenge tests are employed.


Assuntos
Toxina Tetânica , Toxoide Tetânico , Camundongos , Animais , Testes de Neutralização/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Bem-Estar do Animal
18.
BMC Infect Dis ; 23(1): 367, 2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37259032

RESUMO

BACKGROUND: As countries move towards or achieve measles elimination status, serosurveillance is an important public health tool. However, a major challenge of serosurveillance is finding a feasible, accurate, cost-effective, and high throughput assay to measure measles antibody concentrations and estimate susceptibility in a population. We conducted a systematic review to assess, characterize, and - to the extent possible - quantify the performance of measles IgG enzyme-linked assays (EIAs) compared to the gold standard, plaque reduction neutralization tests (PRNT). METHODS: We followed the PRISMA statement for a systematic literature search and methods for conducting and reporting systematic reviews and meta-analyses recommended by the Cochrane Screening and Diagnostic Tests Methods Group. We identified studies through PubMed and Embase electronic databases and included serologic studies detecting measles virus IgG antibodies among participants of any age from the same source population that reported an index (any EIA or multiple bead-based assays, MBA) and reference test (PRNT) using sera, whole blood, or plasma. Measures of diagnostic accuracy with 95% confidence intervals (CI) were abstracted for each study result, where reported. RESULTS: We identified 550 unique publications and identified 36 eligible studies for analysis. We classified studies as high, medium, or low quality; results from high quality studies are reported. Because most high quality studies used the Siemens Enzygnost EIA kit, we generate individual and pooled diagnostic accuracy estimates for this assay separately. Median sensitivity of the Enzygnost EIA was 92.1% [IQR = 82.3, 95.7]; median specificity was 96.9 [93.0, 100.0]. Pooled sensitivity and specificity from studies using the Enzygnost kit were 91.6 (95%CI: 80.7,96.6) and 96.0 (95%CI: 90.9,98.3), respectively. The sensitivity of all other EIA kits across high quality studies ranged from 0% to 98.9% with median (IQR) = 90.6 [86.6, 95.2]; specificity ranged from 58.8% to 100.0% with median (IQR) = 100.0 [88.7, 100.0]. CONCLUSIONS: Evidence on the diagnostic accuracy of currently available measles IgG EIAs is variable, insufficient, and may not be fit for purpose for serosurveillance goals. Additional studies evaluating the diagnostic accuracy of measles EIAs, including MBAs, should be conducted among diverse populations and settings (e.g., vaccination status, elimination/endemic status, age groups).


Assuntos
Sarampo , Humanos , Testes de Neutralização/métodos , Técnicas Imunoenzimáticas , Vírus do Sarampo , Sensibilidade e Especificidade , Anticorpos Antivirais , Imunoglobulina G
19.
J Virol Methods ; 316: 114716, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36965633

RESUMO

Cervical cancer, the second leading cause of cancer-related deaths among women, is caused by human papillomavirus (HPV), a sexually transmitted virus. Vaccination is an effective preventive measure against viral infections and subsequent development of cervical cancer. Enzyme-linked immunosorbent assay (ELISA) is commonly used to measure specific binding antibody titers and assess the immunogenicity of test vaccines in preclinical models or clinical volunteers. Two methods of deriving titers, the endpoint titer (ET) and the effective dilution producing a median maximal effective fold of dilution (ED50) with a cut-off value, are widely used. For HPV, a pseudovirion-based neutralization assay (PBNA) is used to measure functional antibody titers. The ELISA binding titers and functional PBNA titers were found to be well-correlated for all nine HPV types tested in the vaccine, consistent with previous studies on HPV 16/18. Comparing the PBNA results with the two titration methods, the ED50 method showed higher precision and a closer correlation with PBNA results, both for individual types and pooled data analysis for all nine types. When comparing the titration results of the ET method based on a cut-off value with the ED50 method using all the data points across the dilution series, the ED50 method demonstrated better precision and a stronger correlation with PBNA results.


Assuntos
Correlação de Dados , Ensaio de Imunoadsorção Enzimática , Imunogenicidade da Vacina , Testes de Neutralização , Vacinas contra Papillomavirus , Vacinas contra Papillomavirus/classificação , Vacinas contra Papillomavirus/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Testes de Neutralização/métodos , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Anticorpos Neutralizantes/imunologia , Reprodutibilidade dos Testes , Imunogenicidade da Vacina/imunologia
20.
Adv Exp Med Biol ; 1407: 45-60, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36920691

RESUMO

Highly pathogenic emerging and reemerging viruses have serious public health and socioeconomic implications. Although conventional live virus research methods can more reliably investigate disease pathogenicity and evaluate antiviral products, they usually depend on high-level biosafety laboratories and skilled researchers; these requirements hinder in vitro assessments of efficacy, as well as efforts to test vaccines and antibody drugs. In contrast, pseudotyped viruses (i.e., single-round infectious viruses that mimic the membrane structures of various live viruses) are widely used in studies of highly pathogenic viruses because they can be handled in biosafety level 2 facilities. This chapter provides a concise overview of various aspects of pseudotyped virus technologies, including (1) exploration of the mechanisms of viral infection; (2) evaluation of the efficacies of vaccines and monoclonal antibodies based on pseudovirion-based neutralization assay; (3) assessment of antiviral agents (i.e., antibody-based drugs and inhibitors); (4) establishment of animal models of pseudotyped virus infection in vivo; (5) investigation of the evolution, infectivity, and antigenicity of viral variants and viral glycosylation; and (6) prediction of antibody-dependent cell-mediated cytotoxic activity.


Assuntos
Antígenos , Pseudotipagem Viral , Animais , Anticorpos Neutralizantes , Anticorpos Antivirais , Testes de Neutralização/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA