Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.350
Filtrar
1.
Echocardiography ; 41(8): e15892, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39023286

RESUMO

PURPOSE: The extraaortic-valvular cardiac damage (EVCD) Stage has shown potential for risk stratification for patients with aortic stenosis (AS). This study aimed to examine the usefulness of the EVCD Stage in risk stratification of patients with moderate AS and reduced left ventricular ejection fraction (LVEF). METHODS: Clinical data from patients with moderate AS (aortic valve area, .60-.85 cm2/m2; peak aortic valve velocity, 2.0-4.0 m/s) and reduced LVEF (LVEF 20%-50%) were analyzed during 2010-2019. Patients were categorized into three groups: EVCD Stages 1 (LV damage), 2 (left atrium and/or mitral valve damage), and 3/4 (pulmonary artery vasculature and/or tricuspid valve damage or right ventricular damage). The primary endpoint included a composite of cardiac death and heart failure hospitalization, with non-cardiac death as a competing risk. RESULTS: The study included 130 patients (mean age 76.4 ± 6.8 years; 62.3% men). They were categorized into three groups: 26 (20.0%) in EVCD Stage 1, 66 (50.8%) in Stage 2, and 48 (29.2%) in Stage 3/4. The endpoint occurred in 54 (41.5%) patients during a median follow-up of 3.2 years (interquartile range, 1.4-5.1). Multivariate analysis indicated EVCD Stage 3/4 was significantly associated with the endpoint (hazard ratio 2.784; 95% confidence interval 1.197-6.476; P = .017) compared to Stage 1, while Stage 2 did not (hazard ratio 1.340; 95% confidence interval .577-3.115; P = .500). CONCLUSION: The EVCD staging system may aid in the risk stratification of patients with moderate AS and reduced LVEF.


Assuntos
Estenose da Valva Aórtica , Volume Sistólico , Humanos , Masculino , Feminino , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Idoso , Volume Sistólico/fisiologia , Prognóstico , Ecocardiografia/métodos , Medição de Risco/métodos , Estudos Retrospectivos , Índice de Gravidade de Doença , Função Ventricular Esquerda/fisiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia
2.
JACC Cardiovasc Interv ; 17(14): 1631-1651, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39048251

RESUMO

Transcatheter aortic valve replacement (TAVR) has become more common than surgical aortic valve replacement since 2016, with over 200,000 procedures globally each year. As patients increasingly outlive their TAVR devices, managing these cases is a growing concern. Treatment options include surgical removal of the old TAVR device (transcatheter aortic valve [TAV] explant) or implantation of a new transcatheter aortic valve (redo TAV). Redo TAV is complex because of the unique designs of TAV devices; compatibility issues; and the need for individualized planning based on factors such as implant depth, shape, and coronary artery relationships. This review serves as a comprehensive guide for redo TAV, detailing the design characteristics of TAV devices, device compatibility, standardized terminology, and a structured approach for computed tomography analysis. It aims to facilitate decision making, risk identification, and achieving optimal outcomes in redo TAV procedures.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Reoperação , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Resultado do Tratamento , Fatores de Risco , Tomada de Decisão Clínica , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Terminologia como Assunto , Valor Preditivo dos Testes
4.
JACC Cardiovasc Interv ; 17(14): 1667-1675, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39048253

RESUMO

BACKGROUND: Outcomes from transcatheter aortic valve replacement (TAVR) in low-surgical risk patients with bicuspid aortic stenosis beyond 2 years are limited. OBJECTIVES: This study aimed to evaluate 3-year clinical and echocardiographic outcomes from the Evolut Low Risk Bicuspid Study. METHODS: The Evolut Low Risk Bicuspid Study is a prospective, multicenter, single-arm study conducted in 25 U.S. CENTERS: Patients with severe aortic stenosis at low surgical risk with bicuspid aortic valve anatomy (all subtypes) underwent TAVR with a self-expanding, supra-annular Evolut R or PRO (Medtronic) bioprosthesis. An independent clinical events committee adjudicated all deaths and endpoint-related adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 150 patients from December 2018 to October 2019. The mean age was 70.3 ± 5.5 years, 48% (72/150) of the patients were women, and the mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 1.3% (Q1-Q3: 0.9%-1.7%). Sievers type 1 was the dominant bicuspid morphology (90.7%, 136/150). The Kaplan-Meier rates of all-cause mortality or disabling stroke were 1.3% (95% CI: 0.3%-5.3%) at 1 year, 3.4% (95% CI: 1.4%-8.1%) at 2 years, and 4.1% (95% CI: 1.6%-10.7%) at 3 years. The incidence of new permanent pacemaker implantation was 19.4% (95% CI: 12.4%-29.6%) at 3 years. There were no instances of moderate or severe paravalvular aortic regurgitation at 2 and 3 years after TAVR. CONCLUSIONS: The 3-year results from the Evolut Low Risk Bicuspid Study demonstrate low rates of all-cause mortality or disabling stroke and favorable hemodynamic performance.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Bioprótese , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Fatores de Risco , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Medição de Risco , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Estados Unidos/epidemiologia , Índice de Gravidade de Doença , Complicações Pós-Operatórias/mortalidade , Recuperação de Função Fisiológica , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Doenças das Valvas Cardíacas/fisiopatologia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/mortalidade
5.
JACC Cardiovasc Interv ; 17(14): 1680-1690, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39048255

RESUMO

BACKGROUND: Thromboembolic events, particularly strokes, remain a major complication of transcatheter aortic valve replacement (TAVR). Embolic protection devices have failed to show significant clinical benefit in large randomized clinical trials. Aortic wall thrombus (AWT) is often observed on multidetector computed tomography during TAVR work-up, but its prognostic significance is uncertain. OBJECTIVES: This study sought to evaluate the association between the presence of AWT and the incidence of thromboembolic outcomes in patients undergoing transfemoral (TF) TAVR for severe aortic stenosis. METHODS: This was a prospective cohort study of consecutive patients who underwent TF TAVR for severe aortic stenosis between January 2011 and April 2022. A dedicated scale (range: 0-10) was qualitatively used to assess AWT. The primary outcome was a composite of procedural thromboembolic events defined as ischemic stroke, blue toe syndrome, bowel ischemia, or other solid organ infarction. The secondary endpoints were ischemic strokes and procedural death. RESULTS: Of the 641 patients included, severe AWT (score ≥8) was identified in 73 (11.4%). The presence of severe AWT was strongly associated with an increase in the primary outcome (OR: 8.48; 95% CI: 3.36-21.40; P < 0.001). This relationship persisted following multivariable analysis, which adjusted for comorbidities and procedural characteristics. The presence of severe AWT was also found to be associated with an increased incidence of stroke and procedural death (OR: 5.66; 95% CI: 2.00-15.30; P = 0.002 and OR: 4.66; 95% CI: 1.80-11.30; P = 0.002, respectively). CONCLUSIONS: The presence of severe AWT on preprocedural multidetector computed tomography is strongly associated with thromboembolic complications including stroke and mortality after TF TAVR.


Assuntos
Estenose da Valva Aórtica , Artéria Femoral , Índice de Gravidade de Doença , Tromboembolia , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Feminino , Masculino , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estudos Prospectivos , Fatores de Risco , Idoso , Artéria Femoral/diagnóstico por imagem , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/mortalidade , Trombose/epidemiologia , Resultado do Tratamento , Tromboembolia/etiologia , Tromboembolia/diagnóstico por imagem , Tromboembolia/mortalidade , Tromboembolia/prevenção & controle , Incidência , Medição de Risco , Fatores de Tempo , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Tomografia Computadorizada Multidetectores , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Punções
8.
JACC Cardiovasc Interv ; 17(13): 1597-1606, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38986659

RESUMO

BACKGROUND: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs. OBJECTIVES: The aim of our study was to assess the performance of the latest iteration of THVs used off-label in comparison to the purpose-built JVT in inoperable patients with severe AR. METHODS: We performed a multicenter, retrospective registry with 18 participating centers worldwide collecting data on inoperable patients with severe AR of the native valve. A bicuspid aortic valve was the main exclusion criterion. The primary endpoints were technical and device success, 1-year all-cause mortality, and the composite of 1-year mortality and the heart failure rehospitalization rate. RESULTS: Overall, 256 patients were enrolled. THVs used off-label were used in 168 cases (66%), whereas JVT was used in 88 (34%). JVT had higher technical (81% vs 98%; P < 0.001) and device success rates (73% vs 95%; P < 0.001), primarily driven by significantly lower incidences of THV embolization (15% vs 1.1%; P < 0.001), the need for a second valve (11% vs 1.1%; P = 0.004), and moderate residual AR (10% vs 1.1%; P = 0.007). The permanent pacemaker implantation rate was comparable and elevated for both groups (22% vs 24%; P = 0.70). Finally, no significant difference was observed at the 1-year follow-up in terms of mortality (HR: 0.99; P = 0.980) and the composite endpoint (HR: 1.5; P = 0.355). CONCLUSIONS: The JVT platform has a better acute performance than other THVs when used off-label for inoperable patients with severe AR. A longer follow-up is conceivably needed to detect a possible impact on prognosis.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Feminino , Masculino , Estudos Retrospectivos , Idoso , Resultado do Tratamento , Idoso de 80 Anos ou mais , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Readmissão do Paciente , Recuperação de Função Fisiológica , Europa (Continente) , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Hemodinâmica
10.
J Am Heart Assoc ; 13(14): e033125, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-38979804

RESUMO

BACKGROUND: Mitral regurgitation (MR) is frequent in patients with aortic stenosis (AS). Although primary MR is an established negative prognostic factor, whether different mechanisms of MR have different effects on outcome is currently unknown. The aim of this study was to evaluate the impact of the MR mechanism in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: This is a retrospective observational study of patients who underwent TAVR for severe aortic stenosis in a high-volume tertiary care center. Echocardiographic comprehensive MR assessment was performed at baseline and within 3 months post TAVR. The study population was divided into 4 groups according to MR mechanism: Group I: fibro-calcific leaflet degeneration; Group II: prolapse/flail; Group III: ventricular secondary MR (functional MR); and Group IV: atrial functional MR. The study end point was a combination of death from cardiovascular cause and heart failure-related hospitalization. The study population included 427 patients (mean age 81.7±6.5 years; 71% primary MR; 62% ≥moderate MR). At 3-year follow-up, survival free from the composite end point significantly differs according to MR mechanism: it was higher in group IV (atrial functional MR, 96.6%) compared with group I (80.4%, P=0.002) and group II patients (60.7%, P=0.001), and group III (84.8%, P=0.037); patients with MR due to leaflet prolapse showed poorer prognosis compared with patients with functional MR (group III, P=0.023 and group IV, P=0.001) and with group I (P=0.040). Overall, severe MR after TAVR identified patients with poorer prognosis and was significantly more frequent in group II (46.4%, P=0.001). CONCLUSIONS: In patients undergoing TAVR, preprocedural identification of MR mechanism and mechanism provides prognostic insights.


Assuntos
Estenose da Valva Aórtica , Insuficiência da Valva Mitral , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Idoso , Resultado do Tratamento , Ecocardiografia , Fatores de Risco , Fatores de Tempo , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia
12.
J Cardiovasc Med (Hagerstown) ; 25(7): 529-538, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38829939

RESUMO

AIMS: This study assessed the outcomes of concomitant mitral valve disease and severe aortic stenosis in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS: Echocardiographic data of 813 patients with severe aortic stenosis undergoing transfemoral TAVR were collected, and clinical outcomes were analyzed for individuals with mitral stenosis and mitral regurgitation. RESULTS: The final cohort includes 788 patients with severe calcific aortic stenosis. Among single parameters of mitral stenosis, a smaller baseline mitral valve area (MVA) by the continuity equation and higher postprocedural mean mitral gradients (MMG) were associated with an increased risk of death at 1 year (P-values 0.02 and <0.01, respectively), but no correlation with outcomes was demonstrated after multivariate adjustment for major prognosticators. Mitral stenosis (based on MVA + MMG) was not associated with complications or mortality. Mitral regurgitation was present in 94.6% of the population at baseline and regressed by at least one grade post-TAVR in 28% of the patients. The improvement in mitral regurgitation was associated with a greater prosthetic effective orifice area (P-value 0.03). Significant (at least moderate) residual mitral regurgitation was correlated with short-term complications and shown to be an independent predictor of 1-year mortality (P-value 0.02, odds ratio (OR) 5.37, confidence interval 1.34-21.5). CONCLUSION: Mitral regurgitation has a greater impact on TAVR patients than mitral stenosis as assessed by functional methods.


Assuntos
Estenose da Valva Aórtica , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estenose da Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/mortalidade , Estenose da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/complicações , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Idoso , Resultado do Tratamento , Índice de Gravidade de Doença , Estudos Retrospectivos , Prognóstico , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/patologia , Calcinose/mortalidade , Calcinose/diagnóstico por imagem , Calcinose/complicações , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Ecocardiografia
13.
BMC Cardiovasc Disord ; 24(1): 314, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38907344

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a well-established treatment for high and intermediate-risk patients with severe aortic stenosis (AS). Recent studies have demonstrated non-inferiority of TAVI compared to surgery in low-risk patients. In the past decade, numerous literature reviews (SLRs) have assessed the use of TAVI in different risk groups. This is the first attempt to provide an overview of SRs (OoSRs) focusing on secondary studies reporting clinical outcomes/process indicators. This research aims to summarize the findings of extant literature on the performance of TAVI over time. METHODS: A literature search took place from inception to April 2024. We searched MEDLINE and the Cochrane Library for SLRs. SLRs reporting at least one review of clinical indicators were included. Subsequently, a two-step inclusion process was conducted: [1] screening based on title and abstracts and [2] screening based on full-text papers. Relevant data were extracted and the quality of the reviews was assessed. RESULTS: We included 33 SLRs with different risks assessed via the Society of Thoracic Surgeons (STS) score. Mortality rates were comparable between TAVI and Surgical Aortic Valve Replacement (SAVR) groups. TAVI is associated with lower rates of major bleeding, acute kidney injury (AKI) incidence, and new-onset atrial fibrillation. Vascular complications, pacemaker implantation, and residual aortic regurgitation were more frequent in TAVI patients. CONCLUSION: This study summarizes TAVI performance findings over a decade, revealing a shift to include both high and low-risk patients since 2020. Overall, TAVI continues to evolve, emphasizing improved outcomes, broader indications, and addressing challenges.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Medição de Risco , Fatores de Risco , Revisões Sistemáticas como Assunto , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
15.
Echocardiography ; 41(6): e15859, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38853624

RESUMO

Aortic stenosis (AS) stands as the most common valvular heart disease in developed countries and is characterized by progressive narrowing of the aortic valve orifice resulting in elevated transvalvular flow resistance, left ventricular hypertrophy, and progressive increased risk of heart failure and sudden death. This narrative review explores clinical challenges and evolving perspectives in moderate AS, where discrepancies between aortic valve area and pressure gradient measurements may pose diagnostic and therapeutic quandaries. Transthoracic echocardiography is the first-line imaging modality for AS evaluation, yet cases of discordance may require the application of ancillary noninvasive diagnostic modalities. This review underscores the importance of accurate grading of AS severity, especially in low-gradient phenotypes, emphasizing the need for vigilant follow-up. Current clinical guidelines primarily recommend aortic valve replacement for severe AS, potentially overlooking latent risks in moderate disease stages. The noninvasive multimodality imaging approach-including echocardiography, cardiac magnetic resonance, computed tomography, and nuclear techniques-provides unique insights into adaptive and maladaptive cardiac remodeling in AS and offers a promising avenue to deliver precise indications and exact timing for intervention in moderate AS phenotypes and asymptomatic patients, potentially improving long-term outcomes. Nevertheless, what we may have gleaned from a large amount of observational data is still insufficient to build a robust framework for clinical decision-making in moderate AS. Future research will prioritize randomized clinical trials designed to weigh the benefits and risks of preemptive aortic valve replacement in the management of moderate AS, as directed by specific imaging and nonimaging biomarkers.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Ecocardiografia , Humanos , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Ecocardiografia/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Índice de Gravidade de Doença
16.
EuroIntervention ; 20(12): e770-e780, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38887883

RESUMO

BACKGROUND: Coronary access (CA) is a major concern in redo-transcatheter aortic valve implantation (TAVI) for failing supra-annular self-expanding transcatheter aortic valves (TAVs). AIMS: This ex vivo study evaluated the benefit of leaflet splitting (LS) on subsequent CA after redo-TAVI in anatomies deemed at high risk of unfeasible CA. METHODS: Ex vivo, patient-specific models were printed three-dimensionally. Index TAVI was performed using ACURATE neo2 or Evolut PRO (TAV-1) at the standard implant depth and with different degrees of commissural misalignment (CMA). Redo-TAVI was performed using the balloon-expandable SAPIEN 3 Ultra (TAV-2) at different implant depths with commissural alignment. Selective CA was attempted for each configuration before and after LS in a pulsatile flow simulator. The leaflet splay area was assessed on the bench. RESULTS: In matched comparisons of 128 coronary cannulations across 64 redo-TAVI configurations, the overall feasibility of CA significantly increased after LS (60.9% vs 18.7%; p<0.001). The effect of LS varied according to the sinotubular junction height, TAV-1 design, TAV-1 CMA, and TAV-2 implant depth, given TAV-2 alignment. LS enabled CA for up to CMA 45° with the ACURATE neo2 TAV-1 and up to CMA 30° with the Evolut PRO TAV-1. The combination of LS and a low TAV-2 implant provided the highest feasibility of CA after redo-TAVI. The leaflet splay area ranged from 25.60 mm2 to 37.86 mm2 depending on the TAV-1 platform and TAV-2 implant depth. CONCLUSIONS: In high-risk anatomies, LS significantly improves CA feasibility after redo-TAVI for degenerated supra-annular self-expanding platforms. Decisions on redo-TAVI feasibility should be carefully individualised, taking into account the expected benefit of LS on CA for each scenario.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Impressão Tridimensional , Estenose da Valva Aórtica/cirurgia , Vasos Coronários/cirurgia , Falha de Prótese , Reoperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...