Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.587
Filtrar
2.
BMC Cardiovasc Disord ; 24(1): 373, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39026154

RESUMO

BACKGROUND: Interventional valve implantation into the inferior vena cava (CAVI) lowers venous congestion in patients with tricuspid regurgitation (TR). We evaluated the impact of a reduction of abdominal venous congestion following CAVI on circulating immune cells and inflammatory mediators. METHODS: Patients with severe TR were randomized to optimal medical therapy (OMT) + CAVI (n = 8) or OMT (n = 10). In the OMT + CAVI group, an Edwards Sapien XT valve was implanted into the inferior vena cava. Immune cells and inflammatory mediators were measured in the peripheral blood at baseline and three-month follow-up. RESULTS: Leukocytes, monocytes, basophils, eosinophils, neutrophils, lymphocytes, B, T and natural killer cells and inflammatory markers (C-reactive protein, interferon-gamma, interleukin-2, -4, -5, -10, and tumor necrosis factor-alpha) did not change substantially between baseline and three-month follow-up within the OMT + CAVI and OMT group. CONCLUSION: The present data suggest that reduction of venous congestion following OMT + CAVI may not lead to substantial changes in systemic inflammation within a short-term follow-up. CLINICAL TRIAL REGISTRATION: NCT02387697.


Assuntos
Implante de Prótese de Valva Cardíaca , Mediadores da Inflamação , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide , Veia Cava Inferior , Humanos , Masculino , Feminino , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/imunologia , Mediadores da Inflamação/sangue , Resultado do Tratamento , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/sangue , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/imunologia , Pessoa de Meia-Idade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Idoso , Biomarcadores/sangue , Fatores de Tempo , Próteses Valvulares Cardíacas , Valva Tricúspide/cirurgia , Valva Tricúspide/fisiopatologia , Valva Tricúspide/imunologia , Valva Tricúspide/diagnóstico por imagem , Citocinas/sangue , Desenho de Prótese , Estudos Prospectivos
4.
Eur J Cardiothorac Surg ; 66(1)2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38897657

RESUMO

OBJECTIVES: This study aimed to provide comprehensive morphological descriptions of the morphology of the tricuspid valve and to evaluate if a novel echocardiography-based tricuspid valve nomenclature can also be understood anatomically. METHODS: Tricuspid valves of 60 non-embalmed human body donors without a medical history of pathologies or macroscopic malformations of the heart were included. Length, height and surface area of leaflets were measured. The valves were morphologically classified according to a novel echocardiography-based classification, in which 6 types are distinguished: classic 3-leaflet configuration, bicuspid valves, valves with 1 leaflet split into 2 scallops or leaflets and valves with 2 leaflets divided into 2 scallops or leaflets. RESULTS: We found a true 3-leaflet configuration in only 19 (31.7%) of valves. Five (8.3%) had a 2-leaflet configuration with a fused anterior and posterior leaflet. Of those, 3 had a divided septal leaflet. Four valves (6.7%) had a divided anterior leaflet, 17 (28.3%) had a divided posterior leaflet, 6 (10%) had a divided septal leaflet and 9 (15.0%) had 2 leaflets divided. Overall, 39 (65%) of valves have at least 1 leaflet that is divided. In 22 (36.7%) specimens, the leaflet was divided into true leaflets, and in 17 (28.3%) specimens, the leaflet was divided into scallops. In addition, we could identify 9 (15%) valves having 1 leaflet divided not only in 2 but 3 scallops or leaflets. CONCLUSIONS: This study provides further anatomical insight for the significant variability in the morphology of the tricuspid valve. By updating the understanding of its morphological characteristics, this study equips clinicians with valuable insights to effectively advance surgical and interventional treatment of tricuspid valves.


Assuntos
Ecocardiografia , Valva Tricúspide , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/anatomia & histologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Adulto , Ecocardiografia/métodos , Doadores de Tecidos , Adulto Jovem
5.
JACC Cardiovasc Imaging ; 17(7): 729-742, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38842961

RESUMO

BACKGROUND: Tricuspid valve transcatheter edge-to-edge repair (T-TEER) is the most widely used transcatheter therapy to treat patients with tricuspid regurgitation (TR). OBJECTIVES: The aim of this study was to develop a simple anatomical score to predict procedural outcomes of T-TEER. METHODS: All patients (n = 168) who underwent T-TEER between January 2017 and November 2022 at 2 centers were included in the derivation cohort. Additionally, 126 patients from 2 separate institutions served as a validation cohort. T-TEER was performed using 2 commercially available technologies. Core laboratory assessment of procedural transesophageal echocardiograms was used to determine septolateral and anteroposterior coaptation gap, leaflet morphology, septal leaflet length and retraction, chordal structure density, tethering height, en face TR jet morphology and TR jet location, image quality, and the presence of intracardiac leads. A scoring system was derived using univariable and multivariable logistic regression. Endpoints assessed were immediate postprocedural TR reduction ≥2 grades and TR grade moderate or less. RESULTS: The median age was 82 years (Q1-Q3: 78-84 years); 48% of patients were women; and patients presented with severe (55%), massive (36%), and torrential (8%) TR. Five variables (septolateral coaptation gap, chordal structure density, en face TR jet morphology, TR jet location, and image quality) were identified as best predicting procedural outcome and were incorporated in the GLIDE (Gap, Location, Image quality, density, en-face TR morphology) score (range 0-5). TR reduction ≥2 grades and TR grade moderate or less were observed in >90% of patients with GLIDE scores of 0 and 1 and in only 5.6% and 16.7% of those with GLIDE scores ≥4. The GLIDE score was then externally validated in a separate cohort (area under the curve: 0.77; 95% CI: 0.69-0.86). TR reduction significantly correlated with functional improvement assessed by NYHA functional class and 6-minute walk distance at 3 months. CONCLUSIONS: The GLIDE score is a simple, 5-component score that is readily obtained during patient imaging and can predict successful T-TEER.


Assuntos
Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Feminino , Masculino , Idoso , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Resultado do Tratamento , Idoso de 80 Anos ou mais , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Técnicas de Apoio para a Decisão , Medição de Risco , Fatores de Tempo
7.
Cardiol Clin ; 42(3): 351-360, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38910020

RESUMO

Echocardiography, in all its forms (transthoracic echocardiography [TTE], transesophageal echocardiography [TEE], and intracardiac echocardiography [ICE]), is pivotal for the evaluation, guidance, and follow-up of transcatheter tricuspid edge-to-edge repair (TV-TEER) therapies. Although two-dimensional (2D) echocardiography remains essential, three-dimensional (3D) echo with multiplanar reconstruction (MPR) has revolutionized the field of structural imaging. In addition, the advent of 3D ICE has added an important modality to the imaging toolbox, particularly helpful when intraprocedural TEE images are challenging. In this review, we provide a detailed, step-by-step approach for advanced echocardiographic guidance of TV-TEER using 3D MPR.


Assuntos
Cateterismo Cardíaco , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Ecocardiografia/métodos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos
8.
Int J Cardiol ; 411: 132233, 2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-38848770

RESUMO

BACKGROUND: Baseline right ventricular (RV) function derived from 3-dimensional analyses has been demonstrated to be predictive in patients undergoing transcatheter tricuspid valve repair (TTVR). The complex nature of these cumbersome analyses makes patient selection based on established imaging methods challenging. Artificial intelligence (AI)-driven computed tomography (CT) segmentation of the RV might serve as a fast and predictive tool for evaluating patients prior to TTVR. METHODS: Patients suffering from severe tricuspid regurgitation underwent full cycle cardiac CT. AI-driven analyses were compared to conventional CT analyses. Outcome measures were correlated with survival free of rehospitalization for heart-failure or death after TTVR as the primary endpoint. RESULTS: Automated AI-based image CT-analysis from 100 patients (mean age 77 ± 8 years, 63% female) showed excellent correlation for chamber quantification compared to conventional, core-lab evaluated CT analysis (R 0.963-0.966; p < 0.001). At 1 year (mean follow-up 229 ± 134 days) the primary endpoint occurred significantly more frequently in patients with reduced RV ejection fraction (EF) <50% (36.6% vs. 13.7%; HR 2.864, CI 1.212-6.763; p = 0.016). Furthermore, patients with dysfunctional RVs defined as end-diastolic RV volume > 210 ml and RV EF <50% demonstrated worse outcome than patients with functional RVs (43.7% vs. 12.2%; HR 3.753, CI 1.621-8.693; p = 0.002). CONCLUSIONS: Derived RVEF and dysfunctional RV were predictors for death and hospitalization after TTVR. AI-facilitated CT analysis serves as an inter- and intra-observer independent and time-effective tool which may thus aid in optimizing patient selection prior to TTVR in clinical routine and in trials.


Assuntos
Inteligência Artificial , Tomografia Computadorizada por Raios X , Insuficiência da Valva Tricúspide , Humanos , Feminino , Masculino , Inteligência Artificial/tendências , Idoso , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Idoso de 80 Anos ou mais , Tomografia Computadorizada por Raios X/métodos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Cateterismo Cardíaco/métodos , Seguimentos , Implante de Prótese de Valva Cardíaca/métodos
11.
JACC Cardiovasc Interv ; 17(12): 1470-1481, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38925751

RESUMO

BACKGROUND: A novel echocardiography-based definition of atrial functional tricuspid regurgitation (A-FTR) has shown superior outcomes in patients undergoing conservative treatment or tricuspid valve transcatheter edge-to-edge repair. Its prognostic significance for transcatheter tricuspid valve annuloplasty (TTVA) outcomes is unknown. OBJECTIVES: This study sought to investigate prognostic, clinical, and technical implications of A-FTR phenotype in patients undergoing TTVA. METHODS: This multicenter study investigated clinical and echocardiographic outcomes up to 1 year in 165 consecutive patients who underwent TTVA for A-FTR (characterized by the absence of tricuspid valve tenting, midventricular right ventricular [RV] dilatation, and impaired left ventricular ejection fraction) and nonatrial functional tricuspid regurgitation (NA-FTR). RESULTS: A total of 62 A-FTR and 103 NA-FTR patients were identified, with the latter exhibiting more pronounced RV remodeling. Compared to baseline, the tricuspid regurgitation (TR) grade at discharge was significantly reduced (P < 0.001 for both subtypes), and TR ≤II was achieved more frequently in A-FTR (85.2% vs 60.8%; P = 0.001). Baseline TR grade and A-FTR phenotype were independently associated with TR ≤II at discharge and 30 days. In multivariate analyses, A-FTR phenotype was a strong predictor (OR: 5.8; 95% CI: 2.1-16.1; P < 0.001) of TR ≤II at 30 days. At 1 year, functional class had significantly improved compared to baseline (both P < 0.001). One-year mortality was lower in A-FTR (6.5% vs 23.8%; P = 0.011) without significant differences in heart failure hospitalizations (13.3% vs 22.7%; P = 0.188). CONCLUSIONS: Direct TTVA effectively reduces TR in both A-FTR, which is a strong and independent predictor of achieving TR ≤II, and NA-FTR. Even though NA-FTR showed more RV remodeling at baseline, both phenotypes experienced similar symptomatic improvement, emphasizing the benefit of TTVA even in advanced disease stages. Additionally, phenotyping was of prognostic relevance in patients undergoing TTVA.


Assuntos
Cateterismo Cardíaco , Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/mortalidade , Feminino , Masculino , Idoso , Valva Tricúspide/fisiopatologia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Anuloplastia da Valva Cardíaca/efeitos adversos , Anuloplastia da Valva Cardíaca/mortalidade , Anuloplastia da Valva Cardíaca/instrumentação , Fatores de Risco , Idoso de 80 Anos ou mais , Recuperação de Função Fisiológica , Remodelação Ventricular , Função Ventricular Esquerda , Fenótipo , Função Ventricular Direita , Estudos Retrospectivos , Pessoa de Meia-Idade , Volume Sistólico , Valor Preditivo dos Testes
13.
JACC Cardiovasc Interv ; 17(12): 1517-1518, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38842997
14.
Echocardiography ; 41(6): e15861, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38853674

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) is primarily used to guide transcatheter structural heart interventions, such as tricuspid transcatheter edge-to-edge repair (TEER). Although TEE has a good safety profile, it is still an invasive imaging technique that may be associated with complications, especially when performed during long transcatheter procedures or on frail patients. The aim of this study was to assess TEE-related complications during tricuspid TEER. METHODS: This is a prospective study enrolling 53 patients who underwent tricuspid TEER for severe tricuspid regurgitation (TR). TEE-related complications were assessed clinically and divided into major (life-threatening, major bleeding requiring transfusions or surgery, organ perforation, and persistent dysphagia) and minor (perioral hypesthesia, < 24 h dysphagia/odynophagia, minor intraoral bleeding and hematemesis not requiring transfusion) RESULTS: The median age of the patient population was 79 years; 43.4% had severe, 39.6% massive, and 17.6% torrential TR. 62.3% of patients suffered from upper gastrointestinal disorders. Acute procedural success (APS) was achieved in 88.7% in a median device time of 36 min. A negative association was shown between APS and lead-induced etiology (r = -.284, p = .040), baseline TR grade (r = -.410, p = .002), suboptimal TEE view (r = -.349, p = .012), device time (r = -.234, p = .043), and leaflet detachment (r = -.496, p < .0001). We did not observe any clinical manifest major or minor TEE-related complications during the hospitalization. CONCLUSIONS: Our study reinforces the good safety profile and efficacy of TEE guidance during tricuspid TEER. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious complications. Furthermore, suboptimal intraprocedural TEE views are associated with lower TR reduction rates. HIGHLIGHTS: Transesophageal echocardiography is a crucial and safe technique for guiding transcatheter structural heart interventions. A mix of mid/deep esophageal and trans gastric views, as well as real-time 3D imaging is generally used to guide the procedure. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious problems. A shorter device time is associated with more rarely probe-related complications. Suboptimal intraprocedural TEE views are associated with lower TR reduction rates.


Assuntos
Ecocardiografia Transesofagiana , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Ecocardiografia Transesofagiana/métodos , Feminino , Masculino , Estudos Prospectivos , Insuficiência da Valva Tricúspide/cirurgia , Idoso , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Idoso de 80 Anos ou mais
15.
Adv Exp Med Biol ; 1441: 903-907, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38884758

RESUMO

Ebstein anomaly is a rare congenital heart defect, accounting for less than 1% of cardiac malformations and occurring in approximately 1 out of 210,000 live births. It is characterized by an abnormality of the tricuspid valve, where the valve is positioned lower than normal in the right ventricle. Although primarily a tricuspid valve defect, the right ventricle itself is often structurally abnormal and weakened (myopathic).


Assuntos
Anomalia de Ebstein , Valva Tricúspide , Anomalia de Ebstein/diagnóstico por imagem , Anomalia de Ebstein/terapia , Anomalia de Ebstein/fisiopatologia , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/anormalidades , Valva Tricúspide/fisiopatologia , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/patologia
18.
Ren Fail ; 46(2): 2364766, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38874087

RESUMO

AIMS: Recent accumulating evidence has recently documented a significant prevalence of right ventricular dysfunction (RVD) in end-stage renal disease (ESRD) patients. Tricuspid annular plane systolic excursion (TAPSE)/pulmonary-artery systolic pressure (PASP) ratio assessed with echocardiography might be a useful clinical index of right ventricular (RV) -pulmonary arterial (PA) coupling. The current study aimed to investigate the value of the TAPSE/PASP ratios in patients on maintenance hemodialysis (MHD). METHODS: We studied 83 times echocardiographic tests from 68 patients with MHD. The associations of TAPSE/PASP ratios with echocardiography variables, clinical characteristics, and biochemical parameters were analyzed, as well as the associations of TAPSE/PASP ratios with odds of all-cause mortality, cardiovascular disease (CVD) events and frequent intermittent dialysis hypotension (IDH). RESULTS: Correlation analysis showed TAPSE/PASP ratios positively correlated with LVEF and negatively correlated with E/A and E/e' values. For clinical and biochemical parameters, TAPSE/PASP ratios negatively correlated with BNP, NT-proBNP, age, CRP, and average interdialysis weight gain (ΔBW) and positively correlated with albumin. Logistic regression analysis, which induced the TAPSE/PASP ratio as a continuous variable (per 0.1 mm/mmHg increase), identified that the TAPSE/PASP ratio was associated with decreased CVD events (OR 0.386 [95% CI 0.231-0.645], p < 0.001) and frequent IDH odds (OR 0.571 [95% CI 0.397-0.820], p = 0.002). Moreover, the TAPSE/PASP ratio independently predicted CVD events (adjusted HR 0.539 [95% CI 0.391-0.743], p < 0.001) during a follow-up period of 12 months. CONCLUSIONS: RVD, assessed by echocardiography TAPSE/PASP ratio, was found to be associated with increased risks of CVD events and frequent IDH in patients with MHD.


Assuntos
Ecocardiografia , Falência Renal Crônica , Diálise Renal , Disfunção Ventricular Direita , Humanos , Masculino , Feminino , Diálise Renal/efeitos adversos , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Falência Renal Crônica/terapia , Falência Renal Crônica/complicações , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/epidemiologia , Estudos Retrospectivos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Modelos Logísticos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia
20.
Card Electrophysiol Clin ; 16(2): 157-161, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749635

RESUMO

Cardiac implantable electronic device leads can contribute to tricuspid regurgitation and also complicate surgical and transcatheter interventions to manage tricuspid regurgitation. Here we present a case of a patient with sinus node dysfunction and complete heart block who underwent extraction of a right ventricular pacing lead before tricuspid valve surgery. We review the data regarding the contribution of leads to tricuspid regurgitation and the benefits of lead extraction, risks of jailing leads during tricuspid interventions, and pacing considerations around tricuspid valve procedures.


Assuntos
Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Humanos , Bloqueio Cardíaco/terapia , Marca-Passo Artificial/efeitos adversos , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...