Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 413
Filtrar
1.
JACC Cardiovasc Interv ; 17(17): 2023-2037, 2024 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-39260960

RESUMO

BACKGROUND: Research on the role of transcatheter heart valve (THV) deformation and calcium distribution in patients with bicuspid aortic valves (BAVs) undergoing transcatheter aortic valve replacement (TAVR) remains limited. OBJECTIVES: The aim of this study was to evaluate the impact of THV deformation on clinical outcomes in individuals with BAVs undergoing TAVR and the influence of calcium on these outcomes. METHODS: In total, 229 consecutive patients with BAVs who underwent TAVR with balloon-expandable valves and had computed tomography (CT) performed 30 days post-TAVR were analyzed. Patients were stratified into 3 groups: group 1 (n = 125), with no THV underexpansion or eccentricity; group 2 (n = 69), with underexpansion or eccentricity; and group 3 (n = 35), with both. Calcium distribution was assessed using CT, and its associations with clinical outcomes, including all-cause mortality at 3 years and leaflet thrombosis at 30 days, were determined. A subgroup analysis of patients with type 1 BAVs was conducted. RESULTS: Group 3 exhibited higher rates of all-cause mortality than the other groups, along with the highest risk for hypoattenuated leaflet thickening at 30 days. Multivariate analysis identified annular and left ventricular outflow tract calcification as independent predictors of all-cause mortality and hypoattenuated leaflet thickening. In patients with type 1 BAVs, excessive calcification at the raphe and opposite leaflet were associated with all-cause mortality at 3 years. CONCLUSIONS: THV deformation post-TAVR was significantly linked to all-cause mortality in patients with BAVs. Annular and left ventricular outflow tract calcification correlated with increased risks for all-cause mortality and leaflet thrombosis. (Assessment of Transcatheter and Surgical Aortic Bioprosthetic Valve Thrombosis and Its Treatment With Anticoagulation [RESOLVE]; NCT02318342).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valvuloplastia com Balão , Doença da Válvula Aórtica Bicúspide , Calcinose , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Resultado do Tratamento , Fatores de Risco , Fatores de Tempo , Calcinose/diagnóstico por imagem , Calcinose/fisiopatologia , Calcinose/mortalidade , Valvuloplastia com Balão/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/mortalidade , Estudos Retrospectivos , Medição de Risco , Trombose/diagnóstico por imagem , Trombose/etiologia , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes
2.
JACC Cardiovasc Interv ; 17(17): 2041-2051, 2024 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-39177555

RESUMO

BACKGROUND: A prior Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry-based analysis reported similar 1-year clinical outcomes with small (20-mm) vs large (≥23-mm) balloon-expandable valves (BEV). OBJECTIVES: The aim of this study was to describe mid-term 3-year clinical outcomes for small vs large BEV and the relationship between discharge echocardiographic mean gradient (MG) and different definitions of prothesis-patient mismatch (PPM) with clinical outcomes. METHODS: Using the TVT Registry with Centers for Medicare and Medicaid Services linkage, a propensity-matched analysis of patients receiving 20- vs ≥23-mm BEVs was performed. Spline curves and Kaplan-Meier plots with adjusted HRs determined the relationship between MG and 3-year mortality. RESULTS: In total, 316,091 patients were analyzed; after propensity matching, 8,100 pairs of each group were compared. The 20-mm BEV was associated with higher MGs compared with ≥23-mm BEVs (16.2 ± 7.2 mm Hg vs 11.8 ± 5.7 mm Hg; P < 0.0001). At 3 years, there was no difference in mortality between 20- and ≥23-mm BEVs (31.5% vs 32.5%, respectively; HR: 0.97; 95% CI: 0.90-1.05). Compared with an MG of 10 to 30 mm Hg, an MG <10 mm Hg (HR: 1.25; 95% CI:1.22-1.27) was associated with increased 3-year mortality. Measured severe PPM and predicted no PPM were associated with increased 3-year mortality (33.5% vs 32.9% vs 32.1%; P < 0.0001) and (33.5% vs 31.1% vs 30%; P < 0.0001), respectively. Low MG and severe measured PPM were associated with lower left ventricular ejection fraction (LVEF). CONCLUSIONS: Patients with small-prosthesis BEVs (20 mm) had identical 3-year survival as those with larger (≥23-mm) BEV valves. Severe measured PPM and low MG (<10 mm Hg), but not predicted severe PPM, were associated with lower LVEF and increased mortality, suggesting that LVEF is the culprit for worse outcomes.


Assuntos
Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Humanos , Masculino , Feminino , Fatores de Tempo , Resultado do Tratamento , Idoso , Fatores de Risco , Estados Unidos , Valvuloplastia com Balão/mortalidade , Valvuloplastia com Balão/efeitos adversos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Medição de Risco , Hemodinâmica , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade
3.
JACC Cardiovasc Interv ; 17(16): 1916-1931, 2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39197990

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is highly prevalent in the transcatheter aortic valve replacement (TAVR) population, but clear management guidelines are lacking. OBJECTIVES: The aims of this study were to elucidate the prevalence and consequences of severe TR in patients with aortic stenosis undergoing TAVR and to examine the change in TR post-TAVR, including predictors of improvement and its impact on longer term mortality. METHODS: Using Centers for Medicare and Medicaid Services-linked TVT (Transcatheter Valve Therapy) Registry data, a propensity-matched analysis was performed among patients undergoing TAVR with baseline mild, moderate, or severe TR. Kaplan-Meier estimates were used to assess the impact of TR on 3-year mortality. Multivariable analysis identified predictors of 30-day TR improvement. RESULTS: Of the 312,320 included patients, 84% had mild, 13% moderate, and 3% severe TR. In a propensity-matched cohort, severe baseline TR was associated with higher in-hospital mortality (2.5% vs 2.1% for moderate TR and 1.8% for mild TR; P = 0.009), higher 1-year mortality (24% vs 19.6% for moderate TR and 16.6% for mild TR; P < 0.0001), and 3-year mortality (54.2% vs 48.5% for moderate TR and 43.3% for mild TR; P < 0.0001). Among the patients with severe TR at baseline, 76.4% improved to moderate or less TR 30 days after TAVR. Baseline mitral regurgitation moderate or greater, preserved ejection fraction, higher aortic valve gradient, and better kidney function predicted TR improvement after TAVR. However, severe 30-day residual TR was associated with higher 1-year mortality (27.4% vs 18.7% for moderate TR and 16.8% for mild TR; P < 0.0001). CONCLUSIONS: Severe baseline and 30-day residual TR after TAVR are associated with increased mortality up to 3 years. This analysis identifies a higher risk group that could be evaluated for the recently approved tricuspid interventions.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Mortalidade Hospitalar , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Humanos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso de 80 Anos ou mais , Resultado do Tratamento , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/mortalidade , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Idoso , Estados Unidos/epidemiologia , Fatores de Risco , Fatores de Tempo , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valvuloplastia com Balão/mortalidade , Valvuloplastia com Balão/efeitos adversos , Medição de Risco , Prevalência , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Estudos Retrospectivos , Centers for Medicare and Medicaid Services, U.S. , Hemodinâmica
4.
J Am Heart Assoc ; 13(16): e031433, 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39119978

RESUMO

BACKGROUND: It is uncertain which percutaneous balloon mitral valvuloplasty (PBMV) success definitions should be used because there are no studies comparing the effects of these definitions on subsequent outcomes. We evaluated the association between 3 success definitions and long-term clinical outcomes in patients with rheumatic mitral stenosis who underwent PBMV. METHODS AND RESULTS: This multicenter retrospective study included patients with severe rheumatic mitral stenosis who underwent PBMV. Three definitions were used as follows: (A) post-PBMV mitral valve area (MVA) ≥1.5 cm2 or ≥50% increase in MVA with MR <3+; (B) post-PBMV MVA ≥1.5 cm2 and MR ≤2+; and (C) post-PBMV MVA ≥1.5 cm2 or ≥50% increase in MVA, with no more than 1-grade increment in MR. Multivariable Cox regression analyses were performed to evaluate the associations between PBMV success and the composite of all-cause mortality, mitral surgery, and repeat PBMV. Successful PBMV, according to definitions A, B, and C was associated with a lower risk of the composite outcomes (definition A-hazard ratio [HR], 0.55 [95% CI, 0.43-0.69], definition B-HR, 0.55 [95% CI, 0.43-0.69], definition C-HR, 0.55 [95% CI, 0.44-0.69]). Patients meeting all 3 success definitions had the lowest risk compared with those who did not meet any definition or met 1 or 2 definitions. CONCLUSIONS: All 3 success definitions had a prognostic impact on outcomes. Patients who achieved post-PBMV MVA ≥1.5 cm2, irrespective of the percentage increase in MVA, and MR ≤grade 2, with no more than a 1-grade increment in MR, had the most favorable outcomes.


Assuntos
Valvuloplastia com Balão , Estenose da Valva Mitral , Cardiopatia Reumática , Humanos , Estenose da Valva Mitral/terapia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Estudos Retrospectivos , Feminino , Masculino , Cardiopatia Reumática/terapia , Cardiopatia Reumática/complicações , Resultado do Tratamento , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Adulto , Fatores de Tempo , Fatores de Risco , Índice de Gravidade de Doença
5.
BMC Cardiovasc Disord ; 24(1): 391, 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39069638

RESUMO

BACKGROUND: Rheumatic mitral stenosis (MS) remains a common and concerning health problem in Asia. Percutaneous balloon mitral valvuloplasty (PBMV) is the standard treatment for patients with symptomatic severe MS and favorable valve morphology. However, studies on the incidence and predictors of adverse cardiac outcomes following PBMV in Asia have been limited. This study aims to evaluate the incidence and predictors of adverse outcomes in patients with rheumatic MS following PBMV. METHODS: A retrospective cohort study was conducted on patients with symptomatic severe MS who underwent successful PBMV between 2002 and 2020 at a tertiary academic institute in Thailand. Patients were followed up to assess adverse outcomes, defined as a composite of cardiac death, heart failure hospitalization, repeat PBMV, or mitral valve surgery. Univariable and multivariable analyses were performed to identify predictors of adverse outcomes. A p-value of < 0.05 was considered statistically significant. RESULTS: A total of 379 patients were included in the study (mean age 43 ± 11 years, 80% female). During a median follow-up of 5.9 years (IQR 1.7-11.7), 74 patients (19.5%) experienced adverse outcomes, with an annualized event rate of 2.7%. Multivariable analysis showed that age (hazard ratio [HR] 1.03, 95% confidence interval [CI] 1.008-1.05, p = 0.006), significant tricuspid regurgitation (HR 2.17, 95% CI 1.33-3.56, p = 0.002), immediate post-PBMV mitral valve area (HR 0.39, 95% CI 0.25-0.64, p = 0.01), and immediate post-PBMV mitral regurgitation (HR 1.91, 95% CI 1.18-3.07, p = 0.008) were independent predictors of adverse outcomes. CONCLUSIONS: In patients with symptomatic severe rheumatic MS, the incidence of adverse outcomes following PBMV was 2.7% per year. Age, significant tricuspid regurgitation, immediate post-PBMV mitral valve area, and immediate post-PBMV mitral regurgitation were identified as independent predictors of these adverse outcomes.


Assuntos
Valvuloplastia com Balão , Estenose da Valva Mitral , Cardiopatia Reumática , Humanos , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/terapia , Estenose da Valva Mitral/cirurgia , Estenose da Valva Mitral/fisiopatologia , Feminino , Masculino , Cardiopatia Reumática/terapia , Cardiopatia Reumática/epidemiologia , Estudos Retrospectivos , Valvuloplastia com Balão/efeitos adversos , Tailândia/epidemiologia , Adulto , Incidência , Pessoa de Meia-Idade , Resultado do Tratamento , Fatores de Risco , Fatores de Tempo , Medição de Risco , Centros de Atenção Terciária , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Índice de Gravidade de Doença
6.
BMC Cardiovasc Disord ; 24(1): 309, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38890637

RESUMO

BACKGROUND: Percutaneous balloon mitral valvuloplasty (PBMV) is the ACC/AHA class I recommendation for treating symptomatic rheumatic mitral stenosis with suitable valve morphology, less than moderate MR and absence of left atrium clot. The mitral valve restenosis and significant mitral regurgitation (MR) are known adverse outcomes of PBMV. This study aimed to evaluate the outcomes of PBMV in patients with severe mitral stenosis and the effect of Commissural Calcification (CC) on the outcomes. METHODS: In this single-center retrospective cohort study, 876 patients who underwent PBMV were categorized into three groups based on their Wilkins score (Group I: score ≤ 8, Group II: score 9-10, and Group III: score 11-12). Patients were evaluated before, early after PBMV and at 6- and 24-month follow-ups. Main clinical outcomes were defined as significant restenosis and or symptomatic significant MR (moderate to severe and severe MR) or candidate for mitral valve replacement (MVR). The outcomes were compared between patients with and without CC. RESULTS: A total of 876 patients with mean age 46.4 ± 12.3 years (81.0% females) were categorized based on Wilkins score. 333 (38.0%) were in Group I, 501 (57.2%) were in Group II, and 42 (4.8%) were in Group III. CC was present in 175 (20.0%) of the patients, among whom 95 (54.3%) had calcification of the anterolateral commissure, 64 (36.6%) had calcification of the posteromedial commissure, and in 16 (9.1%) patients both commissures were calcified. There was a significant difference in Wilkins score between patients with and without CC (P < 0.001). CC was associated with higher odds of significant symptomatic MR at early and mid-term follow up (OR: 1.69, 95%CI 1.19-2.41, P = 0.003; and OR: 3.90, 95%CI 2.61-5.83, P < 0.001, respectively), but not with restenosis (P = 0.128). Wilkins Groups II and III did not show higher odds of significant symptomatic MR compared to Group I at early (II: P = 0.784; III: P = 0.098) and mid-term follow up (II: P = 0.216; III: P = 0.227). Patients in Wilkins Group II had higher odds of restenosis compared to Group I (OR: 2.96,95%CI: 1.35-6.27, P = 0.007). CONCLUSION: Commissural calcification (CC) is an independent predictor of the significant symptomatic MR (an important determinant of adverse outcome) following PBMV in the early and mid-term follow-up. Mitral valve restenosis occurs more in patients with higher Wilkins score compared to group I with score ≤ 8. Combined Wilkins score and CC should be considered for patient suitability for PBMV.


Assuntos
Valvuloplastia com Balão , Calcinose , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Valva Mitral , Índice de Gravidade de Doença , Humanos , Estudos Retrospectivos , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/terapia , Estenose da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/cirurgia , Feminino , Masculino , Valvuloplastia com Balão/efeitos adversos , Pessoa de Meia-Idade , Resultado do Tratamento , Calcinose/diagnóstico por imagem , Calcinose/terapia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Adulto , Fatores de Tempo , Fatores de Risco , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/terapia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Cardiopatia Reumática/terapia , Cardiopatia Reumática/diagnóstico por imagem , Cardiopatia Reumática/fisiopatologia , Cardiopatia Reumática/complicações , Recidiva , Recuperação de Função Fisiológica
7.
Catheter Cardiovasc Interv ; 104(1): 105-114, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38819623

RESUMO

BACKGROUND: The anatomic substrate of bicuspid valves may lead to suboptimal TAVR stent expansion and geometry. AIM: We evaluated determinants of stent geometry in bicuspid valves treated with Sapien transcatheter aortic valve replacement (TAVR) valves. METHODS: A multicenter retrospective registry of patients (February 2019 to August 2022) who underwent post-TAVR computed tomography to determine stent area (vs. nominal valve area) and stent ellipticity (maximum diameter/minimum diameter). Predictors of relative stent expansion (minimum area/average of inflow + outflow area) and stent ellipticity were evaluated in a multivariable regression model, including valve calcium volume (indexed by annular area), presence of raphe calcium, sinus diameters indexed by area-derived annular diameter, and performance of pre-dilation and post-dilation. RESULTS: The registry enrolled 101 patients from four centers. The minimum stent area (vs. nominal area) was 88.1%, and the maximum ellipticity was 1.10, with both observed near the midframe of the valve in all cases. Relative stent expansion ≥90% was observed in 64/101 patients. The only significant predictor of relative stent expansion ≥90% was the performance of post-dilation (OR: 4.79, p = 0.018). Relative stent expansion ≥90% was seen in 86% of patients with post-dilation compared to 57% without (p < 0.001). The stent ellipticity ≥1.1 was observed in 47/101 patients. The significant predictors of stent ellipticity ≥1.1 were the indexed maximum sinus diameter (OR: 0.582, p = 0.021) and indexed intercommisural diameter at 4 mm (OR: 2.42, p = 0.001). Stent expansion has a weak negative correlation with post-TAVR mean gradient (r = -0.324, p < 0.001). CONCLUSION: Relative stent expansion ≥90% was associated with the performance of post-dilation, and stent ellipticity ≥1.1 was associated with indexed intercommisural diameter and indexed maximum sinus diameter. Further studies to determine optimal deployment strategies in bicuspid valves are needed.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Feminino , Masculino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Idoso , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/cirurgia , Valvuloplastia com Balão/efeitos adversos , Fatores de Risco , Estados Unidos , Stents
8.
Catheter Cardiovasc Interv ; 104(1): 97-104, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38764290

RESUMO

BACKGROUND: The randomized DIRECTAVI trial demonstrated safety and feasibility of transcatheter aortic valve implantation (TAVI) without balloon aortic valvuloplasty (BAV) using SAPIEN 3 balloon-expandable devices. However, the female population with smaller anatomy may have potential higher risk of residual gradient and/or mismatch. PURPOSE: We assessed the impact of BAV on the procedural success rate and clinical outcomes in the female population of the DIRECTAVI trial. METHODS: Between May 2016 and May 2018, 91 of the 250 patients included in the DIRECTAVI trial were women (38.6%), 45 of them (49.5%) were enrolled in the BAV group and 46 of them (50.5%) in the direct TAVI group. The primary endpoint was procedural success rate in women (Valve Academic Research Consortium-2 criteria). The secondary endpoint included evaluation of PPM and 1-month major adverse events according to the implantation stategy in women and comparison between men and women regarding major endpoints. RESULTS: The primary endpoint occurred in 29 women (64.4%) in the BAV group and in 34 women (73.9%) in the direct TAVI group (mean difference 9.47%; 95% confidence interval: 6.5%-25.4%; p = 0.045 for non-inferiority of the direct strategy). One-month major adverse events were similar between the 2 women groups. Procedural success was lower in women vs men (p = 0.01) due to higher incidence of moderate mismatches in women (p = 0.001) but with no significant difference regarding the implantation strategy (p = 0.4). CONCLUSION: Direct implantation of the balloon-expandable SAPIEN 3 valve was non-inferior to predilatation on procedural success in women. Incidence of moderate mismatch was higher in women but was not related to the implantation strategy.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Idoso de 80 Anos ou mais , Resultado do Tratamento , Fatores de Risco , Masculino , Fatores de Tempo , Fatores Sexuais , Medição de Risco , Desenho de Prótese , Hemodinâmica , Recuperação de Função Fisiológica
9.
Heart Vessels ; 39(9): 826-836, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38704418

RESUMO

It is controversial whether children with isolated aortic valvular stenosis (vAS) initially undergo transcatheter or surgical aortic valvuloplasty (BAV or SAV). This multicenter retrospective case-control study aimed to explore outcomes after BAV or SAV for pediatric vAS. We studied children (aged < 15 years) with vAS treated at 4 tertiary congenital heart centers, and compared the rates of survival, reintervention, and valve replacement between patients with BAV and SAV. A total of 73 subjects (BAV: N = 52, SAV: N = 21) were studied. Age and aortic annulus z-score at the first presentation were 85 (26-530) days and - 0.45 (- 1.51-0.59), respectively. During the follow-up period of 121 (47-185) months, rates of 10-year survival (BAV: 88% vs. SAV: 92%, P = 0.477), reintervention (BAV: 58% vs. SAV: 31%, P = 0.626), and prosthetic/autograft valve replacement (BAV: 21% vs. SAV: 19%, P = 0.563) did not differ between the groups. Freedom from reintervention rate significantly correlated with aortic annulus z-score (hazard ratio [HR] 0.66, 95% confidence interval [CI] 0.49-0.88, P = 0.005), and freedom from prosthetic/autograft valve replacement rate significantly correlated to the degree of aortic regurgitation after the first intervention (HR: 4.58, 95% CI 1.19-17.71, P = 0.027). Propensity score-matched analysis (N = 16) did not show the differences in survival and reintervention rates between the groups. Long-term survival was acceptable, and the rates of freedom from reintervention and prosthetic/autograft valve replacement were comparable between children with vAS who underwent BAV and SAV.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Humanos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estudos Retrospectivos , Japão/epidemiologia , Criança , Pré-Escolar , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Lactente , Adolescente , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Substituição da Valva Aórtica Transcateter/métodos , Estudos de Casos e Controles , Valvuloplastia com Balão/métodos , Valvuloplastia com Balão/efeitos adversos , Seguimentos , Fatores de Tempo , Fatores de Risco
10.
J Am Heart Assoc ; 13(10): e033601, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38761069

RESUMO

BACKGROUND: The aims of this study were to understand the incidence and outcomes of patients with cardiogenic shock (CS) due to severe aortic stenosis (AS), and the impact of conventional treatment strategies in this population. METHODS AND RESULTS: All patients admitted to the Cleveland Clinic cardiac intensive care unit between January 1, 2010 and December 31, 2021 with CS were retrospectively identified and categorized into those with CS in the setting of severe AS versus CS without AS. The impact of various treatment strategies on mortality was further assessed. We identified 2754 patients with CS during the study period, of whom 216 patients (8%) had CS in the setting of severe AS. Medical management was associated with the highest 30-day mortality when compared with either balloon aortic valve replacement or aortic valve replacement (surgical or transcatheter aortic valve replacement) (hazard ratio, 3.69 [95% CI, 2.04-6.66]; P<0.0001). Among patients who received transcatheter therapy, 30-day mortality was significantly higher in patients who received balloon aortic valvuloplasty versus transcatheter aortic valve replacement (26% versus 4%, P=0.02). Both surgical and transcatheter aortic valve replacement had considerably lower mortality than medical management and balloon aortic valvuloplasty at 30 days and 1 year (P<0.05 for both comparisons). CONCLUSIONS: CS due to severe AS is associated with high in-hospital and 30-day mortality, worse compared with those with CS without AS. In suitable patients, urgent surgical aortic valvuloplasty or transcatheter aortic valve replacement is associated with favorable short- and long-term outcomes. Although balloon aortic valvuloplasty may be used to temporize patients with CS in the setting of severe AS, mortality is ≈50% if not followed by definitive aortic valve replacement within 90 days.


Assuntos
Estenose da Valva Aórtica , Índice de Gravidade de Doença , Choque Cardiogênico , Substituição da Valva Aórtica Transcateter , Humanos , Choque Cardiogênico/terapia , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso de 80 Anos ou mais , Valvuloplastia com Balão/mortalidade , Valvuloplastia com Balão/efeitos adversos , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Fatores de Risco , Fatores de Tempo , Incidência
12.
Cardiovasc Revasc Med ; 66: 6-14, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38641438

RESUMO

BACKGROUND: Candidates for transcatheter aortic valve replacement (TAVR) occasionally have a "borderline-size" aortic annulus between 2 transcatheter heart valve sizes, based on the manufacturer's sizing chart. Data on TAVR outcomes in such patients are limited. METHODS: We retrospectively reviewed 1816 patients who underwent transfemoral-TAVR with balloon-expandable valve (BEV) at our institution between 2016 and 2020. We divided patients into borderline and non-borderline groups based on computed tomography-derived annular measurements and compared outcomes. Furthermore, we analyzed procedural characteristics and compared outcomes between the smaller- and larger-valve strategies in patients with borderline-size annulus. RESULTS: During a median follow-up of 23.3 months, there was no significant difference between the borderline (n = 310, 17.0 %) and non-borderline (n = 1506) groups in mortality (17.3 % vs. 19.5 %; hazard ratio [HR] = 0.86 [95% CI = 0.62-1.20], p = 0.39), major adverse cardiac/cerebrovascular events (MACCE: death/myocardial infarction/stroke, 21.2 % vs. 21.5 %; HR = 0.97 [0.71-1.32], p = 0.85), paravalvular leak (PVL: mild 21.8 % vs. 20.6 %, p = 0.81; moderate 0 % vs. 1.2 %; p = 0.37), or mean gradient (12.9 ± 5.8 vs. 12.6 ± 5.2 mmHg, p = 0.69) at 1 year. There was no significant difference between the larger-(n = 113) and smaller-valve(n = 197) subgroups in mortality (23.7 % vs. 15.2 %; HR = 1.57 [0.89-2.77], p = 0.12), MACCE (28.1 % vs. 18.4 %; HR = 1.52 [0.91-2.54], p = 0.11), mild PVL (13.3 % vs. 25.9 %; p = 0.12), or mean gradient (12.3 ± 4.5 vs. 13.6 ± 5.3 mmHg, p = 0.16); however, the rate of permanent pacemaker implantation (PPI) was higher in the larger-valve subgroup (15.9 % vs. 2.6 %, p < 0.001). CONCLUSION: Borderline-size annulus is not associated with higher risk of adverse outcomes after BEV-TAVR. However, the larger-valve strategy for borderline-size annulus is associated with higher PPI risk, suggesting a greater risk of injury to the conduction system.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Feminino , Masculino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Resultado do Tratamento , Idoso , Valvuloplastia com Balão/efeitos adversos , Fatores de Risco , Fatores de Tempo , Complicações Pós-Operatórias/etiologia , Medição de Risco , Recuperação de Função Fisiológica , Hemodinâmica
13.
Catheter Cardiovasc Interv ; 103(7): 1088-1092, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38639156

RESUMO

Coronary obstruction during transcatheter aortic valve replacement (TAVR) poses a significant threat, prompting a closer examination of prevention and bailout strategies. Following TAVR deployment with a coronary artery obstruction complication and recognizing the complexities involved in engaging the left main coronary artery through TAVR cells. This case introduces the "Ping-pong" technique using a second guide catheter. When faced with difficulty in engaging the catheter through TAVR cells, an innovative solution is proposed. Inserting a wire into the valsalva and utilizing a rapid inflate-deflate balloon maneuver successfully facilitates catheter access into the left main, offering a promising intervention for challenging scenarios. In conclusion, this study emphasizes the severe implications of coronary obstruction during TAVR. The innovative "Ping-pong" technique and rapid inflate-deflate balloons emerge as valuable interventions, showcasing their potential in challenging catheter engagement scenarios. These insights offer a promising avenue for enhancing patient outcomes in TAVR procedures.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Oclusão Coronária/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Idoso de 80 Anos ou mais , Cateteres Cardíacos , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Angiografia Coronária , Masculino , Feminino
14.
Catheter Cardiovasc Interv ; 103(6): 1004-1014, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38577939

RESUMO

INTRODUCTION: Bicuspid aortic valve (BAV) stenosis is a complex anatomical scenario for transcatheter aortic valve implantation (TAVI). Favorable short-term clinical outcomes have been reported with TAVI in this setting, but long-term data are scarce. METHODS: We retrospectively included, in a single-center registry, patients with BAV stenosis who underwent TAVI before 2020. We compared patients treated with self-expanding valves (SEV) versus balloon-expandable valves (BEV). The primary endpoint was a composite of all-cause mortality, stroke and need for aortic valve (AV) reintervention at 3 years. Secondary endpoints included each component of the primary endpoint, cardiovascular mortality, permanent pacemaker implantation (PPI) rate, mean gradient and ≥moderate paravalvular leak (PVL) rate. RESULTS: A total of 150 consecutive patients (SEV = 83, BEV = 67) were included. No significant differences were reported between SEV and BEV groups for the primary composite endpoint (SEV 35.9% vs. BEV 32%, p = 0.66), neither for clinical secondary endpoints (all-cause mortality SEV 28.1% vs. BEV 28%, p = 0.988; cardiovascular mortality SEV 14.1% vs. BEV 20%, p = 0.399; stroke SEV 12.5% vs. BEV 6%, p = 0.342; need for AV reintervention SEV 0% vs. BEV 0%; PPI SEV 28.1% vs. BEV 24%, p = 0.620). A lower mean gradient persisted up to 3 years in the SEV group (SEV 8.8 ± 3.8 mmHg vs. BEV 10.7 ± 3.2 mmHg, p = 0.063), while no significant difference was found in the rate of ≥ moderate PVL (SEV 3/30 vs. BEV 0/25, p = 0.242). CONCLUSIONS: In this single center registry, we observed favorable 3-year clinical outcomes in nonselected BAV patients treated with different generation devices, without significant differences between patients receiving SEV or BEV.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Resultado do Tratamento , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Fatores de Tempo , Idoso , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Idoso de 80 Anos ou mais , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Recuperação de Função Fisiológica , Hemodinâmica , Medição de Risco
15.
Cardiovasc Revasc Med ; 67: 10-16, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38670866

RESUMO

BACKGROUND: Aortic valve lithotripsy can fragment aortic valve calcium deposits and potentially restore leaflet pliability in animal model and ex-vivo, but clinical data is limited. Transcatheter aortic valve implantation (TAVR) might not be feasible as an urgent procedure in critically ill patients. Balloon valvuloplasty has the major limitation of valve recoil and inducing aortic regurgitation. AIMS: To determine the clinical feasibility of aortic valve lithotripsy-facilitated balloon valvuloplasty in patients with severe aortic stenosis unsuitable for valvular replacement. METHODS: We performed lithotripsy as adjunctive therapy to balloon aortic valvuloplasty in ten consecutive patients, most of whom were deemed unfit for TAVR. Lithotripsy of the aortic valve was performed with simultaneous inflation of one to three peripheral lithotripsy balloons to deliver ultrasound pulses. Rapid pacing was not used during lithotripsy. Aortic valve velocity, gradient, and valve area were measured before and after the procedure by echocardiogram. Transvalvular pressure gradient was recorded intra-procedurally. Periprocedural and ninety-day clinical outcomes were followed. RESULTS: Procedure was technically successful in 9 out of 10 patients and aborted in one patient due to cardiogenic shock. One patient had femoral closure device related complication. There was a statistically significant decrease in valvular gradient and increase in aortic valve area. 9 out of 10 patients recovered from acute episode and were discharged. 6 patients had improvement in NYHA class. 4 patients were subsequently able to receive TAVR. 90-day mortality occurred in 3 patients. There was no stroke or bradyarrhythmia peri-procedurally and no heart failure hospitalization at 90 days. CONCLUSION: Aortic valve lithotripsy-facilitated balloon valvuloplasty has reasonable feasibility, safety and technical reproducibility and acute clinical result. Hemodynamic effect is similar to that of balloon valvuloplasty reported in the literature. Subsequent Prognosis is not altered in critically ill patients.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valvuloplastia com Balão , Estudos de Viabilidade , Litotripsia , Índice de Gravidade de Doença , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/terapia , Estenose da Valva Aórtica/mortalidade , Humanos , Valvuloplastia com Balão/efeitos adversos , Masculino , Feminino , Resultado do Tratamento , Idoso de 80 Anos ou mais , Litotripsia/efeitos adversos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Fatores de Tempo , Hemodinâmica , Recuperação de Função Fisiológica
16.
Circ Cardiovasc Interv ; 17(5): e013608, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38529637

RESUMO

BACKGROUND: Comparative data on transcatheter self-expanding ACURATE neo2 (NEO2) and balloon-expandable SAPIEN 3 Ultra prostheses in technically challenging anatomy of severe aortic valve calcified aortic annuli are scarce. METHODS: A total of 1987 patients with severe native aortic stenosis treated with the self-expanding NEO2 (n=1457) or balloon-expandable SAPIEN 3 Ultra (n=530) from January 2017 to April 2023 were evaluated. The primary end point was procedural outcome according to the Valve Academic Research Consortium 3 definitions. Propensity matching defined 219 pairs with severe calcification (calcium density cutoff, 758 AU/cm2) of the native aortic valve. RESULTS: Technical success (90.4% versus 91.8%; risk difference, 1.4% [95% CI, -4.4 to -7.2]; P=0.737) and device success at 30 days (80.8% versus 75.8%; risk difference, -5.0% [95% CI, -13.2 to 3.1]; P=0.246) were comparable between NEO2 and SAPIEN 3 Ultra. The rate of severe prosthesis-patient mismatch (1.1% versus 10.1%; risk difference, 10.0% [95% CI, 4.0-13.9]; P<0.001) and mean transvalvular gradient ≥20 mm Hg (2.8% versus 14.3%; risk difference, 11.5% [95% CI, 5.8-17.1]; P<0.001) was lower with NEO2. The rate of more-than-mild paravalvular leakage or valve-in-valve due to paravalvular leakage was significantly higher (6.2% versus 0.0%; risk difference, 6.2% [95% CI, -10.1 to -2.7]; P=0.002), and there was a tendency for a higher rate of device embolization or migration (1.8% versus 0.0%; risk difference, -1.8% [95% CI, -4.1 to 0.4]; P=0.123) with NEO2. Multivarate regression revealed no independent impact of transcatheter heart valve selection on device success (odds ratio, 0.93 [95% CI, 0.48-1.77]; P=0.817). CONCLUSIONS: In patients with severely calcified annuli, supraannular implantation of NEO2 showed hemodynamic advantages. Nevertheless, NEO2 was associated with a higher incidence of relevant paravalvular leakage and a numerically higher rate of device embolization than SAPIEN 3 Ultra in this particular patient group.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Calcinose , Próteses Valvulares Cardíacas , Desenho de Prótese , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Masculino , Feminino , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/patologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Resultado do Tratamento , Fatores de Risco , Fatores de Tempo , Medição de Risco , Estudos Retrospectivos , Pontuação de Propensão , Recuperação de Função Fisiológica , Valvuloplastia com Balão/efeitos adversos , Hemodinâmica
17.
Catheter Cardiovasc Interv ; 103(6): 1035-1041, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38545668

RESUMO

A distinctive complication with balloon-expandable (BE) THV platforms such as the Edwards Sapien (Edwards Lifescience) is the possibility of balloon rupture during THV deployment. Balloon rupture is a rare occurrence that can result in stroke due to fragment embolism, incomplete THV expansion, and/or vascular injury upon retrieval of the balloon. Careful evaluation of preoperative computed tomography is essential to identify high-risk cases. While annular and left ventricular outflow tract (LVOT) calcification are widely acknowledged as common risks for balloon injury, it's essential to note that balloon injury can manifest at various anatomical sites. In this review, we discuss the mechanism behind balloon rupture, methods to identify cases at a heightened risk of balloon injury, approaches to mitigate the risk of rupture, and percutaneous retrieval strategies.


Assuntos
Valvuloplastia com Balão , Falha de Equipamento , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/instrumentação , Cateteres Cardíacos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
18.
JACC Cardiovasc Interv ; 17(8): 1032-1044, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38456883

RESUMO

BACKGROUND: The fifth-generation SAPIEN 3 Ultra Resilia valve (S3UR) incorporates several design changes as compared with its predecessors, the SAPIEN 3 (S3) and SAPIEN 3 Ultra (S3U) valves, including bovine leaflets treated with a novel process intended to reduce structural valve deterioration via calcification, as well as a taller external skirt on the 29-mm valve size to reduce paravalvular leak (PVL). The clinical performance of S3UR compared with S3 and S3U in a large patient population has not been previously reported. OBJECTIVES: The aim of this study was to compare S3UR to S3/S3U for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR). METHODS: Patients enrolled in the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between January 1, 2021, and June 30, 2023, who underwent TAVR with S3UR or S3U/S3 valve platforms were propensity-matched and evaluated for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes. RESULTS: 10,314 S3UR patients were propensity matched with 10,314 patients among 150,539 S3U/S3 patients. At 30 days, there were no statistically significant differences in death, stroke, or bleeding, but a numerically higher hospital readmission rate in the S3UR cohort (8.5% vs 7.7%; P = 0.04). At discharge, S3UR patients exhibited significantly lower mean gradients (9.2 ± 4.6 mm Hg vs 12.0 ± 5.7 mm Hg; P < 0.0001) and larger aortic valve area (2.1 ± 0.7 cm2 vs 1.9 ± 0.6 cm2; P < 0.0001) than patients treated with S3/S3U. The 29-mm valve size exhibited significant reduction in mild PVL (5.3% vs 9.4%; P < 0.0001). CONCLUSIONS: S3UR TAVR is associated with lower mean gradients and lower rates of PVL than earlier generations of balloon expandable transcatheter heart valve platforms.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Hemodinâmica , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados Unidos
19.
Cardiology ; 149(5): 487-494, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38527430

RESUMO

INTRODUCTION: The role of balloon aortic valvuloplasty (BAV) in the era of transcatheter aortic valve replacement remains a topic of debate. We sought to study the safety and feasibility of combined BAV and percutaneous coronary intervention (BAV-PCI). METHODS: Between November 2009 and July 2020, all patients undergoing BAV were identified and divided into three groups: combined BAV-PCI (group A), BAV with significant unrevascularised CAD (group B), and BAV without significant CAD (group C). Procedural outcomes and 30-day and one-year mortality were compared. RESULTS: A total of 264 patients were studied (n = 84, 93, and 87 patients in groups A, B, and C, respectively). The STS score was 10.2 ± 8, 13.3 ± 19, and 8.1 ± 7, p = 0.026, in groups A, B, and C, respectively. VARC-3 adjudicated complications were similar among groups (11%, 13%, and 5%, respectively, p = 0.168, respectively). Thirty-day and one-year mortality were 9.8% (n = 26) and 32% (n = 86) of the entire cohort. The differences among groups did not reach statistical significance. Using univariate Cox regression analysis, group B patients were at higher risk of dying compared to group A patients (HR 1.58, 95% CI: 1.11-2.25, p = 0.010). With multivariate Cox regression analysis, the predictors of mortality were STS score, cardiogenic shock, mode of presentation, and lack of subsequent definitive valve intervention. CONCLUSION: In high-risk patients with aortic valve stenosis, combined BAV-PCI is safe and feasible with comparable outcomes to BAV with and without significant CAD.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Valvuloplastia com Balão/métodos , Valvuloplastia com Balão/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Idoso de 80 Anos ou mais , Idoso , Estudos Retrospectivos , Estudos de Viabilidade , Resultado do Tratamento , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/cirurgia
20.
Am Heart J ; 270: 13-22, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38253304

RESUMO

BACKGROUND: Safety and feasibility of transcatheter aortic valve replacement (TAVR) without balloon aortic valvuloplasty (BAV) using the SAPIEN 3 balloon-expandable device has been previously demonstrated. The impact on long-term valve hemodynamic performances and outcomes remains however unknown. We evaluate long-term clinical and hemodynamic results according to the implant strategy (direct TAVR vs BAV pre-TAVR) in patients included in the DIRECTAVI randomized trial (NCT02729519). METHODS: Clinical and echocardiographic follow-up until January 2023 was performed for all patients included in the DIRECTAVI trial since 2016 (n = 228). The primary endpoint was incidence of moderate/severe hemodynamic valve deterioration (HVD), according to the Valve Academic Research defined Consortium-3 criteria (increase in mean gradient ≥10 mmHg resulting in a final mean gradient ≥20 mmHg, or new/worsening aortic regurgitation of 1 grade resulting in ≥ moderate aortic regurgitation). RESULTS: Median follow-up was 3.8 (2.2-4.7) years. Mean age at follow-up was 87 ± 6.7 years. No difference in incidence of HVD in the direct implantation group compared to the BAV group was found (incidence of 1.97 per 100 person-years and 1.45 per 100 person-years, respectively, P = 0.6). Prevalence of predicted prothesis-patient mismatch was low (n = 13 [11.4%] in the direct TAVR group vs n = 15 [13.2%] in BAV group) and similar between both groups (P = .7). Major outcomes including death, stroke, hospitalization for heart failure and pacemaker implantation were similar between both groups, (P = .4, P = .7, P = .3, and P = .3 respectively). CONCLUSION: Direct implantation of the balloon-expandable device in TAVR was not associated with an increased risk of moderate/severe HVD or major outcomes up to 6-year follow-up. These results guarantee wide use of direct balloon-expandable valve implantation, when feasible. CLINICAL TRIALS REGISTRATION NUMBER: NCT05140317.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Seguimentos , Insuficiência da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Tempo , Desenho de Prótese , Valvuloplastia com Balão/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...