Your browser doesn't support javascript.
loading
Poor response to recombinant erythropoietin is associated with loss of T-lymphocyte CD28 expression and altered interleukin-10 production.
Cooper, Angela C; Breen, Cormac P; Vyas, Beejal; Ochola, Josephine; Kemeny, David M; Macdougall, Iain C.
Afiliación
  • Cooper AC; Department of Immunology, Guy's, King's and St Thomas' School of Medicine, King's College Hospital, London, UK. angela.redrup@kcl.ac.uk
Nephrol Dial Transplant ; 18(1): 133-40, 2003 Jan.
Article en En | MEDLINE | ID: mdl-12480971
ABSTRACT

BACKGROUND:

Recombinant erythropoietin (Epo) therapy is well established as an effective treatment for the anaemia of end-stage renal disease. However, 5-10% of such patients do not respond adequately and an important contributory factor to this is chronic inflammation.

METHODS:

The present study compares the circulating T-cell phenotypes of haemodialysis patients who respond poorly to Epo with those who respond well, along with normal controls. Isolated peripheral blood mononuclear cells were labelled with immunofluorescent monoclonal antibodies to surface antigens and analysed by flow cytometry. In vitro mononuclear cell cytokine secretion was also studied in the three subject groups. The cells were cultured for 48 h either without stimulus, with lipopolysaccharide or with monoclonal antibodies to CD3 and CD28.

RESULTS:

C-reactive protein levels were increased in poor responders to Epo (18.6 +/- 20.7 mg/l) compared with good responders (8.7 +/- 8.0 mg/l) and normal controls (3.8 +/- 1.1 mg/l). Patients responding poorly to Epo had increased circulating levels of CD4+/CD28- and CD8+/CD28- T-cells compared with patients responding well to Epo and normal controls. Unstimulated mononuclear cells from poor responders showed increased in vitro generation of interleukin-10 (IL-10) compared with both patients responding well to Epo and normal controls. Additionally, IL-10 generation stimulated by monoclonal antibodies to CD3 and CD28 was increased in poor responders compared with normal controls.

CONCLUSIONS:

These findings suggest that patients responding poorly to Epo may show enhanced immune activation as manifest by changes in both T-cell function and phenotype.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Linfocitos T / Eritropoyetina / Interleucina-10 / Antígenos CD28 / Anemia / Fallo Renal Crónico Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Adult / Humans / Middle aged Idioma: En Revista: Nephrol Dial Transplant Asunto de la revista: NEFROLOGIA / TRANSPLANTE Año: 2003 Tipo del documento: Article País de afiliación: Reino Unido
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Linfocitos T / Eritropoyetina / Interleucina-10 / Antígenos CD28 / Anemia / Fallo Renal Crónico Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Adult / Humans / Middle aged Idioma: En Revista: Nephrol Dial Transplant Asunto de la revista: NEFROLOGIA / TRANSPLANTE Año: 2003 Tipo del documento: Article País de afiliación: Reino Unido
...