Enzyme-linked immunosorbent assays using recombinant envelope protein expressed in COS-1 and Drosophila S2 cells for detection of West Nile virus immunoglobulin M in serum or cerebrospinal fluid.
Muerhoff, A Scott; Dawson, George J; Dille, Bruce; Gutierrez, Robin; Leary, Thomas P; Gupta, Malini C; Kyrk, Charles R; Kapoor, Hema; Clark, Patricia; Schochetman, Gerald; Desai, Suresh M.
Afiliación
  • Muerhoff AS; Infectious Diseases Research and Development, Abbott Diagnostics, Abbott Laboratories, Abbott Park, Illinois 60064-6015, USA. scott.muerhoff@abbott.com
Clin Diagn Lab Immunol ; 11(4): 651-7, 2004 Jul.
Article en En | MEDLINE | ID: mdl-15242936
ABSTRACT
Humans infected with West Nile virus (WNV) develop immunoglobulin M (IgM) antibodies soon after infection. The microtiter-based assays for WNV IgM antibody detection used by most state public health and reference laboratories utilize WNV antigen isolated from infected Vero cells or recombinant envelope protein produced in COS-1 cells. Recombinant antigen produced in COS-1 cells was used to develop a WNV IgM capture enzyme immunoassay (EIA). A supplementary EIA using WNV envelope protein expressed in Drosophila melanogaster S2 cells was also developed. Both assays detected WNV IgM in the sera of experimentally infected rhesus monkeys within approximately 10 days postinfection. Human sera previously tested for WNV IgM at a state public health laboratory (SPHL) were evaluated using both EIAs. Among the sera from 20 individuals with laboratory-confirmed WNV infection (i.e., IgM-positive cerebrospinal fluid [CSF]) that were categorized as equivocal for WNV IgM at the SPHL, 19 were IgM positive and one was negative by the new EIAs. Of the 19 IgM-positive patients, 15 were diagnosed with meningitis or encephalitis; the IgM-negative patient was not diagnosed with neurological disease. There was 100% agreement between the EIAs for the detection of WNV IgM. CSF samples from 21 individuals tested equivocal for WNV IgM at the SPHL; all 21 were positive in both bead assays, and 16 of these patients were diagnosed with neurological disease. These findings demonstrate that the new EIAs accurately identify WNV infection in individuals with confirmed WNV encephalitis and that they exhibit enhanced sensitivity over that of the microtiter assay format.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Virus del Nilo Occidental / Inmunoglobulina M / Ensayo de Inmunoadsorción Enzimática / Proteínas del Envoltorio Viral / Anticuerpos Antivirales Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals / Humans Idioma: En Revista: Clin Diagn Lab Immunol Asunto de la revista: ALERGIA E IMUNOLOGIA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Año: 2004 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Virus del Nilo Occidental / Inmunoglobulina M / Ensayo de Inmunoadsorción Enzimática / Proteínas del Envoltorio Viral / Anticuerpos Antivirales Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals / Humans Idioma: En Revista: Clin Diagn Lab Immunol Asunto de la revista: ALERGIA E IMUNOLOGIA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Año: 2004 Tipo del documento: Article País de afiliación: Estados Unidos
...