Your browser doesn't support javascript.
loading
Quantitative flow cytometry of ZAP-70 levels in chronic lymphocytic leukemia using molecules of equivalent soluble fluorochrome.
Kay, Sigi; Herishanu, Yair; Pick, Marjorie; Rogowski, Ori; Baron, Shoshana; Naparstek, Elizabeth; Polliack, Aaron; Deutsch, Varda R.
Afiliación
  • Kay S; The Hematology Institute, Tel Aviv Sourasky Medical Center,Tel Aviv, Israel.
Cytometry B Clin Cytom ; 70(4): 218-26, 2006 Jul 15.
Article en En | MEDLINE | ID: mdl-16456869
BACKGROUND: ZAP-70 has emerged as a potential pivotal prognostic marker for patients with chronic lymphocytic leukemia (CLL), which could replace immunoglobulin heavy chain mutation status. Although several flow cytometry assays have been described for assessing ZAP-70 in CLL, certain technical and scientific issues remain unsolved, which have prevented results of this crucial test from being reported, even in the best routine flow cytometry laboratories. In this report, we aimed to solve some of these issues by providing a computerized quantitative flow cytometric assay for ZAP-70 within the entire CLL population, which would be easy to perform and enable standardization between laboratories. METHODS: Intracellular ZAP-70 levels in CLL and normal B cells were assessed by molecules of equivalent soluble fluorochrome (MESF), employing Quantum FITC MESF calibration beads to establish a standard curve relating channel value to fluorescence intensity in MESF units and the QuickCal v. 2.2 program (www.bangslabs.com) and clinical relevance of the data was determined. RESULTS: The average ZAP-70 expression value in the CD19(+)/CD5(+) cells from 35 CLL patients was 103,701 MESF when compared with 12,621 MESF in B cells from 20 normal blood samples. "Low" and "high" ZAP-70 CLL subgroups were defined. Patients with "high ZAP-70 MESF" CLL had a shorter time to disease progression (P = 0.0005) and a more advanced clinical stage (P = 0.0018) when compared with patients in the "low ZAP-70 MESF" CLL subgroup. CONCLUSIONS: This quantitative analysis method can be employed to obtain a more specific and highly accurate assessment of ZAP-70 levels in CLL cells. The method can easily be standardized, in any routine flow laboratory, thereby improving reproducibility and reliability of ZAP-70 analysis.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Leucemia Linfocítica Crónica de Células B / Proteína Tirosina Quinasa ZAP-70 / Citometría de Flujo / Colorantes Fluorescentes Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male Idioma: En Revista: Cytometry B Clin Cytom Año: 2006 Tipo del documento: Article País de afiliación: Israel
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Leucemia Linfocítica Crónica de Células B / Proteína Tirosina Quinasa ZAP-70 / Citometría de Flujo / Colorantes Fluorescentes Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male Idioma: En Revista: Cytometry B Clin Cytom Año: 2006 Tipo del documento: Article País de afiliación: Israel
...