Your browser doesn't support javascript.
loading
Intravascular ultrasound comparison of sirolimus-eluting stent versus bare metal stent implantation in diseased saphenous vein grafts (from the RRISC [Reduction of Restenosis In Saphenous Vein Grafts With Cypher Sirolimus-Eluting Stent] trial).
Agostoni, Pierfrancesco; Vermeersch, Paul; Semeraro, Oscar; Verheye, Stefan; Van Langenhove, Glenn; Van den Heuvel, Paul; Convens, Carl; Van den Branden, Frank; Bruining, Nico.
Afiliación
  • Agostoni P; Antwerp Cardiovascular Institute Middelheim, AZ Middelheim, Antwerp, Belgium. agostonipf@gmail.com
Am J Cardiol ; 100(1): 52-8, 2007 Jul 01.
Article en En | MEDLINE | ID: mdl-17599440
ABSTRACT
The randomized Reduction of Restenosis In Saphenous Vein Grafts with Cypher Sirolimus-Eluting Stent trial compared angiographic outcomes of sirolimus-eluting stents (SESs) versus bare metal stents (BMSs) in saphenous vein grafts (SVG). Using intravascular ultrasound (IVUS) performed during 6-month follow-up angiography, we compared the vascular effects of the 2 types of stent on SVGs. Of 75 patients (96 lesions) included, 59 patients underwent IVUS in 61 SVGs; 29 patients received 40 SESs for 34 lesions, and 30 patients received 42 BMSs for 39 lesions. IVUS parameters (diameters, areas, and volumes) were compared in the 2 groups. A specific analysis was performed for overlapping SESs. Median neointimal volume was 1.3 mm(3) (interquartile range 0 to 13.1) in SESs versus 24.5 (7.8 to 39.5) in BMSs (p <0.001). Minimal incomplete stent apposition was detected at only 3 stent edges (2 BMSs, 1 SES) next to ectatic regions of the SVG. Compared with single SESs, overlapping SESs showed significant increases in neointimal reaction, with a neointimal volume of 0.6 mm(3)/mm of stent (0.1 to 1.8) versus 0 (0 to 0.4) in single SESs (p = 0.03), and this phenomenon was mainly localized in overlapping SES segments, where neointimal volume per millimeter of stent was 1.1 mm(3)/mm (0.6 to 4.4) versus 0 (0 to 1.3) in nonoverlapping segments (p = 0.05). In conclusion, SESs effectively inhibit neointimal hyperplasia volume compared with BMSs in diseased vein grafts, without evidence of increased incomplete apposition risk. The neointimal response to overlapping SES layers seems higher than to a single SES layer.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 2_ODS3 Problema de salud: 2_muertes_prematuras_enfermedades_notrasmisibles Asunto principal: Vena Safena / Enfermedad de la Arteria Coronaria / Stents / Sirolimus / Oclusión de Injerto Vascular / Inmunosupresores Tipo de estudio: Clinical_trials Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Am J Cardiol Año: 2007 Tipo del documento: Article País de afiliación: Bélgica
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 2_ODS3 Problema de salud: 2_muertes_prematuras_enfermedades_notrasmisibles Asunto principal: Vena Safena / Enfermedad de la Arteria Coronaria / Stents / Sirolimus / Oclusión de Injerto Vascular / Inmunosupresores Tipo de estudio: Clinical_trials Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Am J Cardiol Año: 2007 Tipo del documento: Article País de afiliación: Bélgica
...