Your browser doesn't support javascript.
loading
3-Tesla versus 1.5-Tesla magnetic resonance diffusion and perfusion imaging in hyperacute ischemic stroke.
Kosior, Robert K; Wright, Caitlin J; Kosior, Jayme C; Kenney, Carol; Scott, James N; Frayne, Richard; Hill, Michael D.
Afiliación
  • Kosior RK; Department of Electrical and Computer Engineering, University of Calgary, Calgary, Alta., Canada.
Cerebrovasc Dis ; 24(4): 361-8, 2007.
Article en En | MEDLINE | ID: mdl-17690549
ABSTRACT

BACKGROUND:

Clinical 3-tesla magnetic resonance imaging systems are becoming widespread. No studies have examined differences between 1.5-tesla and 3-tesla imaging for the assessment of hyperacute ischemic stroke (<6 h from symptom onset). Our objective was to compare 1.5-tesla and 3-tesla diffusion and perfusion imaging for hyperacute stroke using optimized protocols.

METHODS:

Three patients or their surrogate provided informed consent. Diffusion-weighted imaging (DWI) and perfusion-weighted imaging (PWI) was performed sequentially at 1.5 T and 3 T. DWI, apparent diffusion coefficient (ADC) maps and relative time-to-peak (TTP) maps were registered and assessed. DWI contrast-to-noise ratio (CNR) and ADC contrast were measured and compared. The infarct lesion volume (ILV) and thresholded ischemic volume (TIV) were estimated on the ADC and TTP maps, respectively, with the penumbral volume being defined as the difference between these volumes.

RESULTS:

Qualitatively, the 3-tesla TTP images exhibited greater feature detail. Quantitatively, the DWI CNR and ILV were similar at both field strengths, the ADC contrast was greater at 3 T and the TIV and penumbral volumes were much smaller at 3 T.

CONCLUSIONS:

Overall, the 3-tesla diffusion and perfusion images were at least as good and in some ways superior to the 1.5-tesla images for assessing hyperacute stroke. The TTP maps showed greater feature detail at 3 T. The ischemic and penumbra volumes were much greater at 1.5 T, indicating a potential difference in the diagnostic utility of the PWI-DWI mismatch between field strengths.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Isquemia Encefálica / Angiografía por Resonancia Magnética / Accidente Cerebrovascular / Imagen de Difusión por Resonancia Magnética Tipo de estudio: Etiology_studies / Evaluation_studies / Guideline / Observational_studies / Risk_factors_studies Límite: Aged80 / Female / Humans Idioma: En Revista: Cerebrovasc Dis Asunto de la revista: ANGIOLOGIA / CEREBRO Año: 2007 Tipo del documento: Article País de afiliación: Canadá
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Isquemia Encefálica / Angiografía por Resonancia Magnética / Accidente Cerebrovascular / Imagen de Difusión por Resonancia Magnética Tipo de estudio: Etiology_studies / Evaluation_studies / Guideline / Observational_studies / Risk_factors_studies Límite: Aged80 / Female / Humans Idioma: En Revista: Cerebrovasc Dis Asunto de la revista: ANGIOLOGIA / CEREBRO Año: 2007 Tipo del documento: Article País de afiliación: Canadá
...