Long-term intraocular pressure fluctuations and risk of conversion from ocular hypertension to glaucoma.
Medeiros, Felipe A; Weinreb, Robert N; Zangwill, Linda M; Alencar, Luciana M; Sample, Pamela A; Vasile, Cristiana; Bowd, Christopher.
Afiliación
  • Medeiros FA; Hamilton Glaucoma Center and Department of Ophthalmology, University of California San Diego, La Jolla, California 92093-0946, USA. fmedeiros@eyecenter.ucsd.edu
Ophthalmology ; 115(6): 934-40, 2008 Jun.
Article en En | MEDLINE | ID: mdl-17936908
ABSTRACT

PURPOSE:

To investigate whether long-term intraocular pressure (IOP) fluctuations are a risk factor for conversion from ocular hypertension to glaucoma.

DESIGN:

Observational cohort study.

PARTICIPANTS:

The study included 252 eyes of 126 patients with ocular hypertension observed untreated as part of the Diagnostic Innovations in Glaucoma Study. At baseline, ocular hypertensive eyes had elevated IOP, normal visual fields (VFs) on standard automated perimetry, and normal optic discs as evaluated by stereophotograph assessment.

METHODS:

Glaucoma conversion was defined as development of reproducible VF loss or optic disc damage. Analyses included all IOP measurements from the baseline visit to time of progression (for converters) and last follow-up (for nonconverters). Mean IOP and IOP fluctuation were calculated as the arithmetic mean and standard deviation (SD), respectively, of all available IOP measurements per eye. MAIN OUTCOME

MEASURES:

Univariable and multivariable Cox regression analyses were used to evaluate the association between IOP fluctuation and time to progression. Multivariable models adjusted for age, mean IOP, central corneal thickness, vertical cup-to-disc ratio, and pattern SD.

RESULTS:

Forty eyes of 31 subjects developed glaucoma during follow-up. Mean IOPs during follow-up were 25.4+/-4.2 mmHg for the eyes that converted to glaucoma and 24.1+/-3.5 mmHg for the eyes that did not. Corresponding values for IOP fluctuation were 3.16+/-1.35 mmHg and 2.77+/-1.11 mmHg, respectively. Intraocular pressure fluctuation was not a risk factor for conversion to glaucoma both in univariable analysis (hazard ratio [HR], 1.30 per 1 mmHg higher; 95% confidence interval [CI], 0.76-1.96; P = 0.092) and in multivariable analysis (adjusted HR, 1.08 per 1 mmHg higher; 95% CI, 0.79-1.48; P = 0.620). Mean IOP during follow-up was a significant risk factor for progression both in univariable analysis (HR = 1.16 per 1 mmHg higher; 95% CI, 1.04-1.31; P = 0.010) and in multivariable analysis (adjusted HR, 1.20 per 1 mmHg higher; 95% CI, 1.06-1.36; P = 0.005).

CONCLUSION:

Long-term IOP fluctuations do not appear to be significantly associated with the risk of developing glaucoma in untreated ocular hypertensive subjects.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Disco Óptico / Trastornos de la Visión / Campos Visuales / Enfermedades del Nervio Óptico / Glaucoma de Ángulo Abierto / Presión Intraocular Tipo de estudio: Clinical_trials / Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Ophthalmology Año: 2008 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Disco Óptico / Trastornos de la Visión / Campos Visuales / Enfermedades del Nervio Óptico / Glaucoma de Ángulo Abierto / Presión Intraocular Tipo de estudio: Clinical_trials / Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Ophthalmology Año: 2008 Tipo del documento: Article País de afiliación: Estados Unidos
...