ABSTRACT

BACKGROUND:

The usefulness of fast fluid-attenuated inversion-recovery (FLAIR) sequences after administration of contrast medium (f-FLAIR (+)) has been shown in depicting brain tumors including metastases and meningeal carcinomatosis. Contrast-enhanced multi-shot echo-planar FLAIR (Ms-EPI-FLAIR (+)), comprising combined sequences of f-FLAIR (+) and Ms-EPI, may provide the advantages of f-FLAIR (+) along with rapid acquisition.

PURPOSE:

To compare Ms-EPI-FLAIR (+) with post-contrast spin-echo T1-weighted imaging (SE-T1WI (+)) in the depiction of brain metastases. MATERIAL AND

METHODS:

In 14 patients with metastatic tumors of the brain, spin-echo precontrast T1-weighted imaging (SE-T1WI (-)), fast spin-echo T2-weighted imaging (FSE-T2WI), fast-FLAIR, SE-T1WI (+), and Ms-EPI-FLAIR (+) were acquired. For qualitative evaluation of SE-T1WI (+) and Ms-EPI-FLAIR (+), receiver operating characteristic (ROC) analysis was performed in two different readers. For quantitative analysis, the intensity ratios (intensity of tumor divided by intensity of peritumoral region) in SE-T1WI (+) and Ms-EPI-FLAIR (+) were compared.

RESULTS:

Although pre-contrast f-FLAIR detected 84 of 106 tumors, Ms-EPI-FLAIR (+) detected 98 of 106 tumors. In the ROC analysis for observers A and B, Az values in SE-T1WI (+) did not differ from values in Ms-EPI-FLAIR (+). Quantitatively, the intensity ratio in Ms-EPI-FLAIR (+) also did not differ from that in SE-T1WI (+).

CONCLUSION:

Detectability of brain metastases with Ms-EPI-FLAIR (+) is almost similar to that with SE-T1WI (+). Ms-EPI-FLAIR (+) could be an alternative to SE-T1WI (+) in the depiction of brain metastases.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Encefálicas / Imagen por Resonancia Magnética / Imagen Eco-Planar / Medios de Contraste / Gadolinio DTPA Tipo de estudio: Prognostic_studies / Qualitative_research Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Acta Radiol Año: 2007 Tipo del documento: Article País de afiliación: Japón
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Encefálicas / Imagen por Resonancia Magnética / Imagen Eco-Planar / Medios de Contraste / Gadolinio DTPA Tipo de estudio: Prognostic_studies / Qualitative_research Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Acta Radiol Año: 2007 Tipo del documento: Article País de afiliación: Japón
...