A line-scanning semi-confocal multi-photon fluorescence microscope with a simultaneous broadband spectral acquisition and its application to the study of the thylakoid membrane of a cyanobacterium Anabaena PCC7120.
J Microsc
; 228(Pt 2): 240-54, 2007 Nov.
Article
en En
| MEDLINE
| ID: mdl-17970923
We describe the construction and characterization of a laser-line-scanning microscope capable of detection of broad fluorescence spectra with a resolution of 1 nm. A near-infrared femtosecond pulse train at 800 nm was illuminated on a line (one lateral axis, denoted as X axis) in a specimen by a resonant scanning mirror oscillating at 7.9 kHz, and total multi-photon-induced fluorescence from the linear region was focused on the slit of an imaging polychromator. An electron-multiplying CCD camera was used to resolve fluorescence of different colours at different horizontal pixels and fluorescence of different spatial positions in a specimen at different vertical pixels. Scanning on the other two axes (Y and Z) was achieved by a closed-loop controlled sample scanning stage and a piezo-driven objective actuator. The full widths at half maximum of the point-spread function of the system were estimated to be 0.39-0.40, 0.33 and 0.56-0.59 mum for the X (lateral axis along the line-scan), Y (the other lateral axis) and Z axes (the axial direction), respectively, at fluorescence wavelengths between 644 and 690 nm. A biological application of this microscope was demonstrated in a study of the sub-cellular fluorescence spectra of thylakoid membranes in a cyanobacterium, Anabaena PCC7120. It was found that the fluorescence intensity ratio between chlorophyll molecules mainly of photosystem II and phycobilin molecules of phycobilisome (chlorophyll/phycobilin), in the thylakoid membranes, became lower as one probed deeper inside the cells. This was attributable not to position dependence of re-absorption or scattering effects, but to an intrinsic change in the local physiological state of the thylakoid membrane, with the help of a transmission spectral measurement of sub-cellular domains. The efficiency of the new line-scanning spectromicroscope was estimated in comparison with our own point-by-point scanning spectromicroscope. Under typical conditions of observing cyanobacterial cells, the total exposure time became shorter by about 50 times for a constant excitation density. The improvement factor was proportional to the length of the line-scanned region, as expected.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Anabaena
/
Microscopía Confocal
/
Citometría de Imagen
/
Tilacoides
/
Microscopía Fluorescente
Idioma:
En
Revista:
J Microsc
Año:
2007
Tipo del documento:
Article
País de afiliación:
Japón