Your browser doesn't support javascript.
loading
Effect of a ferrule and increased clinical crown length on the in vitro fracture resistance of premolars restored using two dowel-and-core systems.
Meng, Qing-Fei; Chen, Ya-Ming; Guang, Han-Bing; Yip, Kevin H K; Smales, Roger J.
Afiliación
  • Meng QF; Dental Research Institute of Nanjing Medical University, Nanjing, PR China.
Oper Dent ; 32(6): 595-601, 2007.
Article en En | MEDLINE | ID: mdl-18051010
This study investigated the effect of a crown-lengthening ferrule on the fracture resistance of endodontically-treated teeth restored with two dowel-core systems. Thirty-two extracted mandibular first premolars were sectioned perpendicular to the long axis at a point 1.0 mm occlusal to the buccal cementoenamel junction. Following endodontic treatment, the teeth were randomly assigned to four groups: cast Ni-Cr alloy dowel-core with no ferrule (Group A1), cast Ni-Cr alloy dowel-core with 2.0 mm ferrule (Group A2), prefabricated carbon fiber-reinforced dowel-resin core with no ferrule (Group B1) and carbon fiber-reinforced dowel-resin core with 2.0 mm ferrule (Group B2). Each specimen was embedded in a self-cured acrylic resin block from 2.0 mm apical to the margins of a cast Ni-Cr alloy crown, then loaded at 150 degrees from the long axis in a universal testing machine at a crosshead speed of 1.0 mm/minute until fracture. The data were recorded and analyzed using ANOVA and Fisher's exact tests, with alpha = 0.05. Mean failure loads (kN) for the A1, A2, B1 and B2 Groups were: 1.46 (S.D. 0.45), 1.07 (0.21), 1.13 (0.30) and 1.02 (0.27). The teeth restored with cast Ni-Cr dowel-cores and 2.0 mm ferrules demonstrated significantly lower fracture strengths, p = 0.04. There were significant differences in the root fracture patterns between the two dowel systems, with the carbon fiber-reinforced dowel-resin core system, being the less severe p < 0.05. Crown lengthening with a 2.0 mm apical extended ferrule resulted in reduced fracture strengths for endodontically-treated teeth restored using two dowel-core systems and cast metal crowns. The carbon fiber-reinforced dowel-resin core system reduced the severity of the root fractures.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fracturas de los Dientes / Técnica de Perno Muñón / Alargamiento de Corona Tipo de estudio: Clinical_trials Límite: Adult / Humans Idioma: En Revista: Oper Dent Año: 2007 Tipo del documento: Article
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fracturas de los Dientes / Técnica de Perno Muñón / Alargamiento de Corona Tipo de estudio: Clinical_trials Límite: Adult / Humans Idioma: En Revista: Oper Dent Año: 2007 Tipo del documento: Article
...