Your browser doesn't support javascript.
loading
Responders to cardiac resynchronization therapy with narrow or intermediate QRS complexes identified by simple echocardiographic indices of dyssynchrony: the DESIRE study.
Cazeau, Serge J; Daubert, J-Claude; Tavazzi, Luigi; Frohlig, Gerd; Paul, Vince.
Afiliación
  • Cazeau SJ; Inparys Clinical Research Group, 12 rue Pasteur, 92210 - St. Cloud, France. SergeCaz@aol.com
Eur J Heart Fail ; 10(3): 273-80, 2008 Mar.
Article en En | MEDLINE | ID: mdl-18314381
BACKGROUND: Cardiac resynchronization therapy (CRT) is recommended for patients with NYHA class III-IV refractory heart failure (HF), ejection fraction <35% and a QRS >120 ms. We attempted to identify responders to CRT from echocardiographic (echo) indices of mechanical dyssynchrony in patients with QRS<150 ms. METHODS AND RESULTS: The study enrolled 51 men and 9 women (mean age: 64.5 years) in NYHA class III (n=54) or IV (n=6) presenting with a mean ejection fraction: 25.7%, LV end-diastolic diameter: 69.1 mm, and QRS=121+/-19 ms. All patients were implanted with a CRT system and followed for 1 year. Implantation was preceded and followed by clinical, functional and Doppler (D)-echo evaluation. The primary combined endpoint included 1) death from any cause, 2) HF-related hospitalisations, and 3) NYHA class at 6 months. Before implant, 27 patients had > or =1 echo criterion of mechanical dyssynchrony (DES+ group) and 33 had no evidence of dyssynchrony (DES- group). At 12 months, 8 patients (4 per group) had died, 7 from HF. As regards the primary endpoint at 6 months, 33 patients (55%) had improved, 10 (16%) were unchanged, and 17 (29%) had deteriorated. Clinical improvement was observed in 19 of 27 DES+ (70%), versus 14 of 33 DES- (42%) patients (P<0.04). Baseline QRS duration did not predict response to CRT. CONCLUSIONS: In this population of HF patients with QRS<150 ms, the presence of mechanical dyssynchrony at baseline D-echo examination, but not the QRS width, predicted 6-month clinical response to CRT.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 6_ODS3_enfermedades_notrasmisibles Problema de salud: 6_cardiovascular_diseases / 6_other_circulatory_diseases Asunto principal: Arritmias Cardíacas / Estimulación Cardíaca Artificial / Sistema de Conducción Cardíaco / Insuficiencia Cardíaca Tipo de estudio: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Heart Fail Asunto de la revista: CARDIOLOGIA Año: 2008 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 6_ODS3_enfermedades_notrasmisibles Problema de salud: 6_cardiovascular_diseases / 6_other_circulatory_diseases Asunto principal: Arritmias Cardíacas / Estimulación Cardíaca Artificial / Sistema de Conducción Cardíaco / Insuficiencia Cardíaca Tipo de estudio: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Heart Fail Asunto de la revista: CARDIOLOGIA Año: 2008 Tipo del documento: Article País de afiliación: Francia
...