Your browser doesn't support javascript.
loading
Effects of electroacupuncture on a degenerated intervertebral disc using an in-vivo rat-tail model.
Lai, A; Chow, D H K; Siu, W-S; Holmes, A D; Tang, F-H; Leung, M C.
Afiliación
  • Lai A; Department of Health and Technology Informatics, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, People's Republic of China.
Proc Inst Mech Eng H ; 222(2): 241-8, 2008 Feb.
Article en En | MEDLINE | ID: mdl-18441759
Electroacupuncture (EA) has long been used as conservative treatment for low back pain (LBP). Its effect on relief of back pain has been demonstrated in many clinical studies. However, whether it has any effect on the biological properties of an intervertebral disc, which is one of the major causes of LBP, is still unclear. The aim of this study was, therefore, to investigate the effects of EA with different simulation frequencies on an intervertebral disc with simulated degeneration using an in-vivo rat-tail model. In this study, 33 rats were used. Disc degeneration was simulated in the rat caudal 8-9 disc via continuous static compressive loading of 11 N for 2 weeks. EA with a frequency of 2 or 100 Hz was then applied to the degenerated disc for 3 weeks with 3 sessions/week and 20 min/session. The intervertebral disc height was measured before and after compression as well as after EA intervention for 3 weeks. The static compression was found to result in a reduction in the disc height of about 22 per cent. There was no evidence that this change could be reversed after resting or the EA intervention. However, EA at 100 Hz was found to induce a further decrease in disc height, which was not shown for the rats after resting or EA at 2 Hz. The results of this study showed that effects of EA on disc degeneration are frequency dependent and adverse effects could result if EA at a certain frequency was used.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Electroacupuntura / Modelos Animales de Enfermedad / Desplazamiento del Disco Intervertebral / Inestabilidad de la Articulación Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals / Humans / Male Idioma: En Revista: Proc Inst Mech Eng H Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2008 Tipo del documento: Article
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Electroacupuntura / Modelos Animales de Enfermedad / Desplazamiento del Disco Intervertebral / Inestabilidad de la Articulación Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals / Humans / Male Idioma: En Revista: Proc Inst Mech Eng H Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2008 Tipo del documento: Article
...