Precise coulometric titration of sodium thiosulfate and development of potassium iodate as a redox standard.
Asakai, Toshiaki; Murayama, Mariko; Tanaka, Tatsuhiko.
Afiliación
  • Asakai T; National Institute of Technology and Evaluation, 2-49-10, Nishihara, Shibuya-ku, Tokyo 151-0066, Japan.
Talanta ; 73(2): 346-51, 2007 Sep 15.
Article en En | MEDLINE | ID: mdl-19073038
ABSTRACT
In this paper, we determine the effective purity of potassium iodate as a redox standard with a certified value linked to the international system of units (SI units). Concentration measurement of sodium thiosulfate solution was performed by precise coulometric titration with electrogenerated iodine, and an assay of potassium iodate was carried out by gravimetric titration based on the reductometric factor of sodium thiosulfate assigned by coulometry. The accuracy of the coulometric titration method was evaluated by examining the current efficiency of iodine electrogeneration, stability of sodium thiosulfate solutions and dependence on the amount of sodium thiosulfate solution used. The measurement procedure for gravimetric titration of potassium iodate with sodium thiosulfate was validated based on determination of a reference material of known purity (potassium dichromate determined by coulometry with electrogenerated ferrous ions) using the same gravimetric method. Solutions of 0.2 and 0.5mol/L sodium thiosulfate were stable over 17 days without stabilizer. Investigation of the dependency of titration results on the amount of sodium thiosulfate solution used showed no significant effects, no evidence of diffusion of the sample, and no effect of contamination appearing during the experiment. Precise coulometric titration of sodium thiosulfate achieved a relative standard deviation of less than 0.005% under repeating conditions (six measurements). For gravimetric titration, the results obtained for the effective purity of potassium dichromate were sufficiently close to its certified value to allow confirmation of the validity of the gravimetric titration was confirmed. The relative standard deviation of gravimetric titration for potassium iodate was less than 0.011% (nine measurements), and a redox standard with a certified value linked to SI units was developed.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Talanta Año: 2007 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Talanta Año: 2007 Tipo del documento: Article País de afiliación: Japón
...