Your browser doesn't support javascript.
loading
The effect of reporting methods for dosing times on the estimation of pharmacokinetic parameters of escitalopram.
Jin, Yuyan; Pollock, Bruce G; Frank, Ellen; Florian, Jeff; Kirshner, Margaret; Fagiolini, Andrea; Kupfer, David J; Gastonguay, Marc R; Kepple, Gail; Feng, Yan; Bies, Robert R.
Afiliación
  • Jin Y; University of Pittsburgh Medical Center, Department of Pharmaceutical Sciences and Psychiatry, 805 Salk Hall, Pittsburgh, PA 15261, USA.
J Clin Pharmacol ; 49(2): 176-84, 2009 Feb.
Article en En | MEDLINE | ID: mdl-19179296
ABSTRACT
The objective of this study was to compare population pharmacokinetic models of escitalopram developed from dosage times recorded by a medication event monitoring system (MEMS) versus the reported times from patients with diagnosed depression. Seventy-three patients were prescribed doses of 10, 15, or 20 mg escitalopram daily. Sparse blood samples were collected at weeks 4, 12, 24, and 36 with 185 blood samples obtained from the 73 patients. NONMEM was used to develop a population pharmacokinetic model based on dosing records obtained from MEMS prior to each blood sample time. A separate population pharmacokinetic analysis using NONMEM was performed for the same population using the patient-reported last dosing time and assuming a steady-state condition as the model input. Objective function values and goodness-of-fit plots were used as model selection criteria. The absolute mean difference in the last dosing time between MEMS and patient-reported times was 4.48 +/- 10.12 hours. A 1-compartment model with first-order absorption and elimination was sufficient for describing the data. Estimated oral clearance (CL/F) to escitalopram was statistically insensitive to reported dosing methods (MEMS vs patient reported 25.5 [7.0%] vs 26.9 [6.6%] L/h). However, different dosing report methods resulted in significantly different estimates on the volume of distribution (V/F; MEMS vs patient reported 1000 [17.3%] vs 767 [17.5%] L) and the absorption rate constant K(a) (MEMS vs patient reported 0.74 [45.7%] vs 0.51 [35.4%] h(-1)) for escitalopram. Furthermore, the parameters estimated from the MEMS method were similar to literature reported values for V/F ( approximately 1100 L) and K(a) ( approximately 0.8-0.9 h(-1)) arising from traditional pharmacokinetic approaches.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Citalopram / Antidepresivos de Segunda Generación / Trastorno Depresivo Mayor / Modelos Biológicos Tipo de estudio: Clinical_trials / Prognostic_studies Límite: Adult / Animals / Female / Humans / Male / Middle aged Idioma: En Revista: J Clin Pharmacol Año: 2009 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Citalopram / Antidepresivos de Segunda Generación / Trastorno Depresivo Mayor / Modelos Biológicos Tipo de estudio: Clinical_trials / Prognostic_studies Límite: Adult / Animals / Female / Humans / Male / Middle aged Idioma: En Revista: J Clin Pharmacol Año: 2009 Tipo del documento: Article País de afiliación: Estados Unidos
...