Your browser doesn't support javascript.
loading
Extrusion of the device: a rare complication of the pacemaker implantation.
Santarpia, Giuseppe; Sarubbi, Berardo; D'Alto, Michele; Romeo, Emanuele; Calabro, Raffaele.
Afiliación
  • Santarpia G; Department of Cardiology, Second University of Naples, Monaldi Hospital, Naples, Italy. santarpi@tin.it
J Cardiovasc Med (Hagerstown) ; 10(4): 330-2, 2009 Apr.
Article en En | MEDLINE | ID: mdl-19444942
ABSTRACT
Skin erosion caused by the pacemaker is widely documented, but the complete extrusion of the device is very rare. We describe the case of a 54-year-old woman who was admitted to hospital because of skin erosion, followed by the complete extrusion of the pacemaker pulse generator out of the subcutaneous pocket. The patient underwent a lead extraction procedure and a new pacemaker, in the contralateral side, was implanted. This case demonstrates that the early stages of skin erosion favoured by the device, if neglected, may cause more serious complications that may require the removal of the hardware.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Marcapaso Artificial / Fibrilación Atrial / Infecciones Estafilocócicas / Estimulación Cardíaca Artificial / Migración de Cuerpo Extraño Tipo de estudio: Diagnostic_studies Límite: Female / Humans / Middle aged Idioma: En Revista: J Cardiovasc Med (Hagerstown) Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2009 Tipo del documento: Article País de afiliación: Italia
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Marcapaso Artificial / Fibrilación Atrial / Infecciones Estafilocócicas / Estimulación Cardíaca Artificial / Migración de Cuerpo Extraño Tipo de estudio: Diagnostic_studies Límite: Female / Humans / Middle aged Idioma: En Revista: J Cardiovasc Med (Hagerstown) Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2009 Tipo del documento: Article País de afiliación: Italia
...