Your browser doesn't support javascript.
loading
Determining corneal power using Pentacam after myopic photorefractive keratectomy.
Falavarjani, Khalil Ghasemi; Hashemi, Masih; Joshaghani, Mahmoud; Azadi, Pejvak; Ghaempanah, Mohammad J; Aghai, Gholam H.
Afiliación
  • Falavarjani KG; Eye Research Center, Iran University of Medical Sciences, Rassoul Akram Hospital, Sattarkhan-Niayesh Street, Tehran, Iran. drghasemi@yahoo.com
Clin Exp Ophthalmol ; 38(4): 341-5, 2010 May.
Article en En | MEDLINE | ID: mdl-20491804
PURPOSE: To assess the accuracy of Pentacam Scheimpflug camera for corneal power measurement in eyes with previous photorefractive keratectomy for myopia. METHODS: In this comparative interventional case series, 35 eyes of 35 patients who had myopic photorefractive keratectomy were studied. Corneal power was measured by conventional topography and Pentacam Scheimpflug camera, and equivalent keratometry readings (EKR) in different central corneal rings (0.5 to 4.5 mm), true net power and simulated keratometry (K) measurements as well as those obtained using Shammas no-history, Koch-Maloney and Haigis methods were compared with clinical history method. RESULTS: All corneal power measurements except for the topography simulated K and true net power values were statistically similar to the clinical history values. Simulated keratometry and 4.5-mm EKR values were more closely correlated with clinical history method. Shammas formula, Pentacam simulated K and 3-, 4- and 4.5-mm EKR provided a 95% confidence interval within +/-0.50 D of the mean clinical history method value, among these, the width of the 95% limits of agreement (LoA) was narrower for Shammas and Pentacam simulated K and 4.5-mm EKR values; however, considerably large 95% LoA were found between each of these values and those obtained with the clinical history method. Estimated preoperative keratometry was statistically similar to the preoperative measurement; however, estimated refractive change was different from actual value. CONCLUSIONS: The Pentacam 4.5-mm EKR and simulated keratometry may be used as an alternative to clinical history method to predict corneal power when pre-keratorefractive surgery data are unavailable; however, wide LoA should be considered in the calculations.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fotograbar / Queratectomía Fotorrefractiva / Córnea / Técnicas de Diagnóstico Oftalmológico / Miopía Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Clin Exp Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2010 Tipo del documento: Article País de afiliación: Irán

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fotograbar / Queratectomía Fotorrefractiva / Córnea / Técnicas de Diagnóstico Oftalmológico / Miopía Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Clin Exp Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2010 Tipo del documento: Article País de afiliación: Irán
...