Your browser doesn't support javascript.
loading
Reproducibility of isokinetic peak torque assessments of the hip flexor and extensor muscles.
Julia, M; Dupeyron, A; Laffont, I; Parisaux, J-M; Lemoine, F; Bousquet, P-J; Hérisson, C.
Afiliación
  • Julia M; Hôpital Lapeyronie, CHRU de Montpellier, France. m-julia@chu-montpellier.fr
Ann Phys Rehabil Med ; 53(5): 293-305, 2010 Jun.
Article en En, Fr | MEDLINE | ID: mdl-20634166
ABSTRACT

OBJECTIVES:

Isokinetic assessment is currently the reference method for measuring dynamic muscle strength. We have sought to evaluate the reproducibility over time of isokinetic testing of the hip flexor (FI) and extensor (Ext) muscles and to establish whether there is a significant difference in peak torque (PT) between the left and right hips. PATIENTS AND

METHODS:

Ten adults were tested once a week for 3 weeks by the same investigator and according to the same protocol, with two velocities (60 degrees /s and 180 degrees /s) for the hip FI and Ext in concentric tests and one velocity (30 degrees /s) for the Ext only in eccentric tests. The reproducibility of the measured PT was analyzed by using the intraclass correlation coefficient (ICC) and a Bland and Altman plot. The difference in PT between the right and left hips was tested using Student's T test.

RESULTS:

The ICC for the observed PT values revealed very good reproducibility (with a value of between 0.75 and 0.96) for the hip FI and Ext measurements (regardless of the body side, test velocity or contraction mode). We did not observe any significant PT differences between the right and left hips.

CONCLUSION:

The isokinetic assessment of the concentric and eccentric PT values generated by the hip FI and Ext is highly reproducible. There is no difference between dominant and nondominant body sides, which enables the use of the contralateral limb as a reference.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Músculos Psoas / Torque / Músculo Cuádriceps / Prueba de Esfuerzo / Fuerza Muscular Límite: Adult / Female / Humans / Male Idioma: En / Fr Revista: Ann Phys Rehabil Med Asunto de la revista: MEDICINA FISICA / REABILITACAO Año: 2010 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Músculos Psoas / Torque / Músculo Cuádriceps / Prueba de Esfuerzo / Fuerza Muscular Límite: Adult / Female / Humans / Male Idioma: En / Fr Revista: Ann Phys Rehabil Med Asunto de la revista: MEDICINA FISICA / REABILITACAO Año: 2010 Tipo del documento: Article País de afiliación: Francia
...