Your browser doesn't support javascript.
loading
Molecular X-ray computed tomography of myelin in a rat brain.
Jensen, T H; Bech, M; Bunk, O; Menzel, A; Bouchet, Audrey; Le Duc, G; Feidenhans'l, R; Pfeiffer, F.
Afiliación
  • Jensen TH; Niels Bohr Institute, University of Copenhagen, Copenhagen, Denmark. Electronic address: torbenj@fys.ku.dk.
  • Bech M; Niels Bohr Institute, University of Copenhagen, Copenhagen, Denmark; Department of Physics, Technische Universit¨at M¨unchen, Garching, Germany.
  • Bunk O; Paul Scherrer Institut, Villigen PSI, Switzerland. Electronic address: oliver.bunk@psi.ch.
  • Menzel A; Paul Scherrer Institut, Villigen PSI, Switzerland.
  • Bouchet A; European Synchrotron Radiation Facility, Grenoble, France; Grenoble Institute of Neurosciences (Team 7), Grenoble, France.
  • Le Duc G; European Synchrotron Radiation Facility, Grenoble, France.
  • Feidenhans'l R; Niels Bohr Institute, University of Copenhagen, Copenhagen, Denmark.
  • Pfeiffer F; Department of Physics, Technische Universit¨at M¨unchen, Garching, Germany. Electronic address: franz.pfeiffer@ph.tum.de.
Neuroimage ; 57(1): 124-129, 2011 Jul 01.
Article en En | MEDLINE | ID: mdl-21514390
ABSTRACT
In this work we demonstrate the feasibility of applying small-angle X-ray scattering computed tomography (SAXS-CT) for non-invasive molecular imaging of myelin sheaths in a rat brain. Our results show that the approach yields information on several quantities, including the relative myelin concentration, its periodicity, the total thickness of the myelin sheaths, and the relative concentration of cytoskeletal neurofilaments. For example the periodicity of the myelin sheaths varied in the range from 17.0 to 18.2 nm around an average of 17.6 (±0.3) nm. We believe that imaging, i.e., spatially resolved measuring these quantities could provide general means for understanding the relation to a number of neurodegenerative diseases.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Difracción de Rayos X / Encéfalo / Tomografía Computarizada por Rayos X / Imagenología Tridimensional / Dispersión del Ángulo Pequeño / Vaina de Mielina Límite: Animals Idioma: En Revista: Neuroimage Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2011 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Difracción de Rayos X / Encéfalo / Tomografía Computarizada por Rayos X / Imagenología Tridimensional / Dispersión del Ángulo Pequeño / Vaina de Mielina Límite: Animals Idioma: En Revista: Neuroimage Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2011 Tipo del documento: Article
...