Your browser doesn't support javascript.
loading
Endovascular treatment of iatrogenic axillary artery pseudoaneurysm under echographic control: a case report.
Mazzaccaro, Daniela; Malacrida, Giovanni; Occhiuto, Maria T; Stegher, Silvia; Tealdi, Domenico G; Nano, Giovanni.
Afiliación
  • Mazzaccaro D; University of Milan, Italy. danymazzak83@libero.it
J Cardiothorac Surg ; 6: 78, 2011 May 27.
Article en En | MEDLINE | ID: mdl-21619625
AIM: Brief case report of the treatment of a large axillary artery pseudoaneurysm after a pacemaker using a left brachial cutdown and a retrograde delivery of a covered stent using ultrasound and fluoroscopic guidance. The patient's renal function precluded the use of contrast materials. CASE REPORT: A 77 years old man presenting with acute renal failure and haemoglobin decrease arrived with an expanding pseudoaneurysm of the left axillary artery from a pacemaker placement. Considering the site of the lesion and patient's comorbidities, under echographic control, a Hemobahn® stent-graft was placed; fluoroscopy assisted manipulation of guidewires and sheaths into the aortic arch. The procedure was successfully ended without any complications. At 8 months the stent graft was still patent. CONCLUSION: Ultrasound guidance may represent an alternative for pseudo-aneurysm exclusion without any use of contrast medium, especially in those patient where lesions are easily detectable using ultrasonography and when comorbidities contraindicate aggressive surgical or angiographic approach.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 / 2_ODS3 Problema de salud: 1_doencas_nao_transmissiveis / 2_muertes_prematuras_enfermedades_notrasmisibles Asunto principal: Marcapaso Artificial / Arteria Axilar / Stents / Angioscopía / Aneurisma Falso / Implantación de Prótesis Vascular Tipo de estudio: Diagnostic_studies / Etiology_studies / Guideline / Observational_studies / Prognostic_studies Límite: Aged / Humans / Male Idioma: En Revista: J Cardiothorac Surg Año: 2011 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 / 2_ODS3 Problema de salud: 1_doencas_nao_transmissiveis / 2_muertes_prematuras_enfermedades_notrasmisibles Asunto principal: Marcapaso Artificial / Arteria Axilar / Stents / Angioscopía / Aneurisma Falso / Implantación de Prótesis Vascular Tipo de estudio: Diagnostic_studies / Etiology_studies / Guideline / Observational_studies / Prognostic_studies Límite: Aged / Humans / Male Idioma: En Revista: J Cardiothorac Surg Año: 2011 Tipo del documento: Article País de afiliación: Italia
...