Your browser doesn't support javascript.
loading
Characterisation of in vivo ovarian cancer models by quantitative 1H magnetic resonance spectroscopy and diffusion-weighted imaging.
Canese, Rossella; Pisanu, Maria Elena; Mezzanzanica, Delia; Ricci, Alessandro; Paris, Luisa; Bagnoli, Marina; Valeri, Barbara; Spada, Massimo; Venditti, Massimo; Cesolini, Albino; Rodomonte, Andrea; Giannini, Massimo; Canevari, Silvana; Podo, Franca; Iorio, Egidio.
Afiliación
  • Canese R; Department of Cell Biology and Neurosciences, Istituto Superiore di Sanità, Rome, Italy. rossella.canese@iss.it
NMR Biomed ; 25(4): 632-42, 2012 Apr.
Article en En | MEDLINE | ID: mdl-22020805
ABSTRACT
Magnetic resonance imaging (MRI) and spectroscopy (MRS) offer powerful approaches for detecting physiological and metabolic alterations in malignancies and help investigate underlying molecular mechanisms. Research on epithelial ovarian carcinoma (EOC), the gynaecological malignancy with the highest death rate characterised by frequent relapse and onset of drug resistance, could benefit from application of these molecular imaging approaches. In this study, MRI/MRS were used to characterise solid tumour models obtained by subcutaneous (s.c.) or intraperitoneal (i.p.) implantation of human SKOV3.ip cells in severe combined immunodeficiency (SCID) mice. In vivo MRI/MRS, ex vivo magic-angle-spinning (MAS), and in vitro (1)H-NMR measurements were carried out at 4.7 T, 9.4 T, and 9.4/16.5 T, respectively. MRI evaluation was performed by T1-, T2-, and diffusion-weighted (DW) multislice spin-echo imaging. The in vivo (1)H spectra of all tumour models showed a prominent resonance of total choline-containing metabolites (tCho). Quantitative in vivo MRS of both i.p. and s.c. SKOV3.ip xenografts showed that the mean tCho content was in the 2.9-4.5 mM range, with a mean PCho/tCho ratio of 0.99 ± 0.01 [23 examinations, 14-34 days post injection (dpi)], in good agreement with ex vivo and in vitro analyses. Myo-inositol ranged between 11.7 and 17.0 mM, with a trend towards higher values in i.p. xenografts at 14-16 dpi. The average apparent diffusion coefficient (ADC) values of SKOV3.ip xenografts [1.64 ± 0.11 (n = 9, i.p.) and 1.58 ± 0.03 x10(-3) mm(2)/s (n = 7, s.c.)] were in agreement with values reported for tumours from patients with EOC, while the mean vascular signal fraction (VSF) was lower (≤ 4%), probably due to the more rapid growth of preclinical models. Both s.c. and i.p. xenografts are valuable preclinical models for monitoring biochemical and physiopathological changes associated with in vivo EOC tumour growth and response to therapy, which may serve as the basis for further clinical development of noninvasive MR approaches.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Ováricas / Espectroscopía de Resonancia Magnética / Biomarcadores de Tumor / Diagnóstico por Computador / Imagen de Difusión por Resonancia Magnética Tipo de estudio: Diagnostic_studies / Evaluation_studies / Prognostic_studies Límite: Animals / Female / Humans Idioma: En Revista: NMR Biomed Asunto de la revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Año: 2012 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Ováricas / Espectroscopía de Resonancia Magnética / Biomarcadores de Tumor / Diagnóstico por Computador / Imagen de Difusión por Resonancia Magnética Tipo de estudio: Diagnostic_studies / Evaluation_studies / Prognostic_studies Límite: Animals / Female / Humans Idioma: En Revista: NMR Biomed Asunto de la revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Año: 2012 Tipo del documento: Article País de afiliación: Italia
...