Your browser doesn't support javascript.
loading
Evaluation of the accuracy of articular cartilage thickness measurement by B-mode ultrasonography with conventional imaging and real-time spatial compound ultrasonography imaging.
Ohashi, Satoru; Ohnishi, Isao; Matsumoto, Takuya; Bessho, Masahiko; Matsuyama, Juntaro; Tobita, Kenji; Kaneko, Masako; Nakamura, Kozo.
Afiliación
  • Ohashi S; Department of Sensory and Motor System Medicine, Faculty of Medicine, University of Tokyo, Tokyo, Japan. soohashi-tky@umin.ac.jp
Ultrasound Med Biol ; 38(2): 324-34, 2012 Feb.
Article en En | MEDLINE | ID: mdl-22230136
ABSTRACT
The present study aimed to quantify the thickness of articular cartilage (Tc) in vitro using both conventional and real-time spatial compound B-mode ultrasonography (US) with a clinically used transducer and to evaluate the accuracy of measurement by comparing the results with values obtained microscopically. Femoral condyle samples were obtained from a 6-month-old pig and a 3-year-old pig. B-mode US images with conventional imaging and real-time spatial compound imaging (RTSCI) of osteochondral blocks were acquired. Tc determined using US (Tc-US) was measured from line data parallel to US beam direction acquired from B-mode images with an objective method for determining cartilage surface and bone-cartilage interfaces at the peak brightness values. Tc was also determined under microscopy (Tc-optical) using the corresponding points from US measurement. Tc-US was compared with Tc-optical to assess accuracy. Tc-US correlated significantly with Tc in both conventional imaging and RTSCI (r = 0.961, 0.976, respectively). Bland-Altman plots showed mean differences between Tc-optical and Tc-US were -0.0073 mm and 0.0139 mm with standard deviations of 0.171 mm and 0.131 mm for conventional imaging and RTSCI, respectively. Our results show that Tc-US measurement using B-mode US allows accurate measurement of Tc. Considering correlation coefficients between Tc-US and Tc-optical, RTSCI US may offer higher accuracy for measuring Tc than conventional methods when an objective tissue border determination algorithm is used, even though both showed good accuracy in our study.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Algoritmos / Interpretación de Imagen Asistida por Computador / Cartílago Articular / Ultrasonografía Tipo de estudio: Diagnostic_studies Límite: Animals Idioma: En Revista: Ultrasound Med Biol Año: 2012 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Algoritmos / Interpretación de Imagen Asistida por Computador / Cartílago Articular / Ultrasonografía Tipo de estudio: Diagnostic_studies Límite: Animals Idioma: En Revista: Ultrasound Med Biol Año: 2012 Tipo del documento: Article País de afiliación: Japón
...