Your browser doesn't support javascript.
loading
Anesthesia recordkeeping: accuracy of recall with computerized and manual entry recordkeeping.
Davis, Thomas Corey; Green, Jeffrey A; Colquhoun, Alexander; Hage, Brenda L; Biddle, Chuck.
Afiliación
  • Davis TC; Department of Nurse Anesthesia, School of Allied Health Professions, Virginia Commonwealth University, Richmond, VA 23298-0226, USA. tcdavis@vcu.edu
J Clin Monit Comput ; 26(3): 163-9, 2012 Jun.
Article en En | MEDLINE | ID: mdl-22426831
ABSTRACT
Anesthesia information management systems (AIMS) are rapidly gaining widespread acceptance. Aggressively promoted as an improvement to manual-entry recordkeeping systems (MERS) in the areas of accuracy, quality improvement, billing and vigilance, these systems record all patient vital signs and parameters, providing a legible hard copy and permanent electronic record. Concern exists that the practitioner may be less vigilant unless this data is recorded manually. This study's purpose was to determine if vigilance, as measured by the ability to recall important data, is influenced by the method of recordkeeping. This study analyzed differences in the accuracy of Certified Registered Nurse Anesthetists' (CRNAs) recall of specific patient variables during the course of an actual anesthetic case. CRNAs using AIMS were compared to CRNAs using MERS. Accuracy of recalled values of 10 patient variables was measured highest and lowest values for heart rate, systolic blood pressure, inspiratory pressure, and end-tidal carbon dioxide levels, lowest oxygen saturation and total fluid volume. Four tertiary care facilities participated in this research; two of which used MERS, two utilized AIMS. A total of 214 subjects participated in this study; 106 in the computerized recordkeeping group, and 108 in the manual entry recordkeeping group. Demographic covariates were analyzed to ensure homogeneity between groups and facilities. No significant statistical differences were identified between the accuracy of recall among the groups. There was no difference in the accuracy of practitioners' recall of patient variables when using computerized or manual entry recordkeeping systems, suggesting little impact on vigilance.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 Problema de salud: 1_sistemas_informacao_saude Asunto principal: Registros Médicos / Sistemas de Registros Médicos Computarizados / Anestesia Tipo de estudio: Evaluation_studies / Prognostic_studies Límite: Humans País/Región como asunto: America do norte Idioma: En Revista: J Clin Monit Comput Asunto de la revista: INFORMATICA MEDICA / MEDICINA Año: 2012 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 Problema de salud: 1_sistemas_informacao_saude Asunto principal: Registros Médicos / Sistemas de Registros Médicos Computarizados / Anestesia Tipo de estudio: Evaluation_studies / Prognostic_studies Límite: Humans País/Región como asunto: America do norte Idioma: En Revista: J Clin Monit Comput Asunto de la revista: INFORMATICA MEDICA / MEDICINA Año: 2012 Tipo del documento: Article País de afiliación: Estados Unidos
...