Your browser doesn't support javascript.
loading
Comparative study of cardiac anatomic measurements obtained by echocardiography and dual-source computed tomography.
Park, Nohwon; Lee, Miyoung; Lee, Ahra; Lee, Seungyeon; Lee, Soyun; Song, Sunhye; Jung, Joohyun; Eom, Kidong.
Afiliación
  • Park N; Department of Veterinary Radiology and Diagnostic Imaging, College of Veterinary Medicine, Konkuk University, 1 Hwayang-dong, Gwangjin-gu, Seoul 143-701, Korea.
J Vet Med Sci ; 74(12): 1597-602, 2012 Dec.
Article en En | MEDLINE | ID: mdl-22850528
ABSTRACT
The aim of this study was to verify the accuracy of echocardiography by dual-source computed tomography (DSCT). Seven normal beagles underwent DSCT and echocardiography. Echocardiographic measurements were obtained according to the American Society of Echocardiography guidelines. The DSCT images were reconstructed onto the same echocardiographic image plane by using a reconstruction program, and then anatomical measurements were obtained. Nonparametric analysis was used for verifying the significance of each of the measured parameters. The anatomical measurements obtained using echocardiography and DSCT were not significant (P>0.05), and the difference between the measurements obtained using both the methods were within 95% confidence intervals except those for interventricular septal thickness and left ventricular posterior wall thickness in end diastole. The reasons for these differences were considered to be the adjacent structures such as papillary muscles or chordae tendineae that may have influenced the echocardiographic findings, lower far-field image quality of echocardiography, low test-retest reproducibility of echocardiography, high-quality images of DSCT minimizing the motion artifact and the retrospective ECG gating technique of DSCT that offered an adequate timing decision for the systolic and diastolic phase during cardiac movement. Although there were differences in the measurements of interventricular septal thickness and left ventricular posterior wall thickness in end diastole obtained using echocardiography and DSCT, we could conclude that echocardiographic measurement is as accurate and reliable as DSCT for cardiac anatomical assessment.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ecocardiografía / Tomografía Computarizada Multidetector / Corazón Tipo de estudio: Prognostic_studies Límite: Animals / Humans / Male Idioma: En Revista: J Vet Med Sci Asunto de la revista: MEDICINA VETERINARIA Año: 2012 Tipo del documento: Article
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ecocardiografía / Tomografía Computarizada Multidetector / Corazón Tipo de estudio: Prognostic_studies Límite: Animals / Humans / Male Idioma: En Revista: J Vet Med Sci Asunto de la revista: MEDICINA VETERINARIA Año: 2012 Tipo del documento: Article
...