Computed tomographic study of the optimal safe implantation corridors in feline thoraco-lumbar vertebrae.
Vallefuoco, R; Bedu, A S; Manassero, M; Viateau, V; Niebauer, G; Moissonnier, P.
Afiliación
  • Vallefuoco R; Dr. Rosario Vallefuoco, DVM, Centre Hospitalier Universitaire Vétérinaire d'Alfort, 7 Av. Du Gen. De Gaulle, Maisons-Alfort, 94700, France, E-mail: rvallefuoco@gmail.com.
Vet Comp Orthop Traumatol ; 26(5): 372-8, 2013.
Article en En | MEDLINE | ID: mdl-23612735
OBJECTIVE: To define the implantation corridors in feline thoraco-lumbar vertebrae (T10-L7) using computed tomography (CT) for optimal safe placement of the implants (screws/pins) in spinal column stabilization. STUDY DESIGN: Computed tomographic study. MATERIALS AND METHODS: Computed tomography images of feline spinal column (n = 10) were used to define the optimal safe implantation corridors (OSIC) in the transverse plane. The OSIC were defined as corridors allowing the greatest amount of bone purchase with safe margins for implantation of the bicortical implants. They were characterized by their insertion point, optimal angle (from the midsagital plane), maximum and minimum safe angles (from the same insertion points), length, and width. RESULTS: The OSIC are located within the vertebral bodies. Insertion points were situated at the level of the vertebro-costal joint or the base of the transverse process of the vertebral body for thoracic and lumbar vertebrae, respectively. The mean optimal angle of the OSIC was 90.2° with a maximum deviation angle from optimal angle of 10° dorsally and 8.8° ventrally in thoracic vertebrae, and 90.5° with a maximum deviation angle from the optimal angle of 8.4° dorsally and 7.6° ventrally in lumbar vertebrae. CONCLUSION AND CLINICAL RELEVANCE: Corridors drilled in the vertebral body perpendicular to the midsagital plane (90°) or with a small angle (≤10°) of deviation from the optimal angle provide an optimal safe placement of bicortical implants. However, perpendicular implant placement may not always be feasible due to surrounding soft tissue structures.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vértebras Torácicas / Tomografía Computarizada por Rayos X / Gatos / Vértebras Lumbares Límite: Animals Idioma: En Revista: Vet Comp Orthop Traumatol Asunto de la revista: MEDICINA VETERINARIA / ORTOPEDIA / TRAUMATOLOGIA Año: 2013 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vértebras Torácicas / Tomografía Computarizada por Rayos X / Gatos / Vértebras Lumbares Límite: Animals Idioma: En Revista: Vet Comp Orthop Traumatol Asunto de la revista: MEDICINA VETERINARIA / ORTOPEDIA / TRAUMATOLOGIA Año: 2013 Tipo del documento: Article
...