Your browser doesn't support javascript.
loading
Glomerular filtration rate equations overestimate creatinine clearance in older individuals enrolled in the Baltimore Longitudinal Study on Aging: impact on renal drug dosing.
Dowling, Thomas C; Wang, En-Shih; Ferrucci, Luigi; Sorkin, John D.
Afiliación
  • Dowling TC; Department of Pharmacy Practice and Science, School of Pharmacy, University of Maryland, Baltimore, Maryland.
Pharmacotherapy ; 33(9): 912-21, 2013 Sep.
Article en En | MEDLINE | ID: mdl-23625813
ABSTRACT

OBJECTIVES:

To evaluate the performance of kidney function estimation equations and to determine the frequency of drug dose discordance in an older population.

DESIGN:

Cross-sectional analysis of data from community-dwelling volunteers randomly selected from the Baltimore Longitudinal Study of Aging from January 1, 2005, to December 31, 2010.

SUBJECTS:

A total of 269 men and women with a mean ± SD age of 81 ± 6 years, mean serum creatinine concentration (Scr ) of 1.1 ± 0.4 mg/dl, and mean 24-hour measured creatinine clearance (mClcr ) of 53 ± 13 ml/minute. MEASUREMENTS AND MAIN

RESULTS:

Kidney function was estimated by using the following equations Cockcroft-Gault (CG), Modification of Diet in Renal Disease (MDRD), and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI). The performance of each equation was assessed by measuring bias and precision relative to mClcr . Dose calculation errors (discordance) were determined for 10 drugs requiring renal dosage adjustments to avoid toxicity when compared with the dosages approved by the Food and Drug Administration. The CG equation was the least biased estimate of mClcr . The MDRD and CKD-EPI equations were significantly positively biased compared with CG (mean ± SD 34 ± 20% and 22 ± 15%, respectively, p<0.001) and mClcr (29 ± 47% and 18 ± 40%, respectively, p<0.001). Rounding low Scr values (less than 1.0 mg/dl) up to an arbitrary value of 1.0 mg/dl resulted in CG values (44 ± 10 ml/minute) that were significantly lower than mClcr (56 ± 12 ml/minute, p<0.001) and CG (56 ± 15 ml/minute, p<0.001). The MDRD and CKD-EPI equations had median dose discordance rates of 28.6% and 22.9%, respectively.

CONCLUSION:

The MDRD and CKD-EPI equations significantly overestimated creatinine clearance (mClcr and CG) in elderly individuals. This leads to dose calculation errors for many drugs, particularly in individuals with severe renal impairment. Thus equations estimating glomerular filtration rate should not be substituted in place of the CG equation in older adults for the purpose of renal dosage adjustments. In addition, the common practice of rounding or replacing low Scr values with an arbitrary value of 1.0 mg/dl for use in the CG equation should be avoided. Additional studies that evaluate alternative eGFR equations in the older populations that incorporate pharmacokinetic and pharmacodynamic outcomes measures are needed.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Envejecimiento / Creatinina / Cálculo de Dosificación de Drogas / Tasa de Filtración Glomerular / Riñón / Pruebas de Función Renal / Errores de Medicación Tipo de estudio: Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male País/Región como asunto: America do norte Idioma: En Revista: Pharmacotherapy Año: 2013 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Envejecimiento / Creatinina / Cálculo de Dosificación de Drogas / Tasa de Filtración Glomerular / Riñón / Pruebas de Función Renal / Errores de Medicación Tipo de estudio: Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male País/Región como asunto: America do norte Idioma: En Revista: Pharmacotherapy Año: 2013 Tipo del documento: Article
...